Fire Shelters What is so new about the New Generation Fire Shelter.

Slides:



Advertisements
Similar presentations
Portable Fire Extinguisher Safety
Advertisements

Pneumatic Cylinders Chapter 3.
Avoiding cuts in the kitchen …..they are no longer part of the job! Knife Sharpening using a steel.
Working Safely in an Engineering Environment Element 3 - Apply safe working practices and procedures Page 2File ref:
HEAT.
Tent Pitching.
1 One-Man Adult CPR. 2 Remember: CPR can save lives. Do it well. Do it right. And the victim gets a chance at life.
Male haircuts - Classic cut
Open-Path Gas Detection - Philosophy of Use or The Story of Clouds.
Preventing Back Injuries
Module 9 Confined Space.
1 A GUIDE TO LABORATORY SAFETY School of Engineering and Science February 2009 HEALTH, ENGINEERING AND SCIENCE.
When to put out a fire When to exit How to use a fire extinguisher Developed by Division of Occupational Safety and Health (DOSH) October, 2009 USING A.
PPE (Personal Protective Clothing)
1 Trade Skills HVACR116 Fiberglass Duct Board and Insulation Material.
Respiratory Protection
Use and Limitation of N-95 Filtering Facepiece Environment, Health and Safety Occupational Health and Hygiene 2009.
Elevator Operator Training Contents  Hazards  Recordable Injury  Types of Elevators  Inspections  Check List  Authorized Operator  Load capacity.
SFFMA Training Objectives: –
Assessment.
Preventing Fires in Manure Storage Structures J. Richard Nottingham Extension Agent Somerset County.
Hand Protection (Gloves) Training on the use of hand protection in the workplace Developed by the Division of Occupational Safety & Health (DOSH) for employee.
Wind Chill Temperature is: The temperature it "feels like" outside and is based on the rate of heat loss from exposed skin caused by the effects of wind.
General Ladder Use and Hazards. Introduction Ladders are important and essential tools that are used widely in a variety of industries. They help us move.
1 Chapter 16 Rescue Procedures. Introduction Rescue has many meanings. Firefighters must be aware of existing dangers and minimize the risks. Consistent.
Decontaminate Your Skin Using the Reactive Skin Decontamination Lotion (RSDL) PFC Powers, Tifani.
1 MSA RTP Officials Safety Training Programme (ASN) (Month & Year) 1 1 MSA RTP Officials Safety Training Programme RAAT May Royal Automobile Association.
SAFETY MANAGEMENT. Keep in Shape It helps you lift and move more safely. Strive for ideal weight: If you have less of your own weight to carry around,
Temperature and the Atmosphere. Without heat there is no weather. The most influential factor effecting weather in the atmosphere is heat. The most influential.
Development and Implementation of an Improved Fire Shelter for Wildland Firefighters Leslie Anderson USDA Forest Service Missoula Technology and Development.
Fitting of Personal Protective Equipment (PPE) and taking swabs for influenza This presentation is for quick reference only. You must also complete the.
Personal Protective Equipment An Employee Awareness & Training Course
Laboratory Safety.
Copyright © 2008 Emergency Training Solutions, LLC. All rights reserved. Firefighter I - Firefighting Basic Tools.
Shoulder & Back 10 Minute Metabolism Booster A 1.Jumping Jacks: 10 reps 1. Begin by standing with your feet together and arms at your sides. Tighten your.
Strength Training- Easy Routines To Do Anywhere, Any Time Jennifer Butcher Fitness Instructor Washington State School for the Blind.
How to Change Windshield Wipers. Why is it that we never seem to remember to change our windshield wipers? You know you need 'em, you know they're cheap,
EXERCISES By: Fabio Pawlus. Pull-ups Grab the pull-up bar with the palms facing forward using the prescribed grip. Note on grips: For a wide grip, your.
Basic Electrical Safety
Science Classroom Safety
13 Search and Rescue. 2 Objectives (1 of 2) Define search and rescue. Describe the importance of scene size- up in search and rescue. Describe search.
Business 21 Publishing © 2006 Fall Protection A user-friendly training module to help supervisors and workers:  Understand fall protection  Prevent injuries.
Select the Proper Bat Comfortable Stance Stride and Hands (Load) Quick Swing Straight to Ball Long Follow Through.
Chapter 5 Defensive Driving
Preventing Sports Injuries
Before we learn how to extinguish fires, we first need to know a little about how they work. The fire triangle to the right shows the three things that.
PERSONAL PROTECTIVE EQUIPMENT State of Georgia BASIC FIRE FIGHTER TRAINING COURSE.
Garaventa Evacuation Chair Guidelines Presented by Risk Management Mt. SAC Garaventa Evac-Trac CD7.
Pink slides are by authors above, and are available online at: transfer-and-cooking-methods#
Click to Enter. Circuit 1Circuit 2Circuit 3 Circuit 4Circuit 5.
Shop Safety Electrical Hazards….  Even small electric shocks are dangerous  Many hazards include electrocution, fire, or explosions  Even small electric.
Rutherford County Workplace Injuries and Safety “In safety, we concern ourselves not just with the tasks but how we accomplish the task.”
MOULDING. Fibres, Fabrics, Foams, Moulds A fibre can only be moulded if it can be heat set. Moulding a fibre is to stretch it to a new shape take it to.
Search and Rescue.
HOSE ROLLS Straight roll ◦Lay the hose out straight and flat on a clean surface ◦Roll the male coupling over onto the hose to start the roll ◦Form a coil.
Please complete Bellringer on your desk.
Safety for Health Science Students. Classroom Rules No running, climbing, or throwing. Keep bags and purses on shelf or under desk. Keep your hands to.
This is a self-propelled hovercraft, designed to use only one motor which will both lift the vehicle and propel it forward. The hovercraft works by creating.
Presented to: By: Date: Federal Aviation Administration International Aircraft Materials Fire Test Working Group Meeting Task Group Session on Revised.
Planning and Preparation To plan properly: Be Ready : Responsible hunters anticipate problems and make plans to deal with them. Know Your Location : Learn.
Timing (minutes) Learning ObjectiveMain tasks / ProcessResources / tools 5TitleStandard Operating Procedures for Power Press Machine Slide 1 5Index 
DURAM PERSONAL ESCAPE MASK A simple step for survival Training Manual.
Sports Medicine: Physical Fitness. 1. Review guidelines for muscular endurance exercises 2. Design a circuit training program to develop muscular endurance.
Fire Service Incidents. Today’s fire service does much more than fight fires. The Fire Service has become the primary source of emergency response and.
Atlas is pleased to present…. What Is a Radiant Barrier? The Turkey Analogy.
Fitting of Personal Protective Equipment (PPE) and taking swabs for influenza This PPE module presentation is also accessible on the MLE (Managed Learning.
Energy Transfer in the Atmosphere.
Leslie Anderson USDA Forest Service
Lesson 5 APPLY A DRESSING TO AN OPEN CHEST WOUND
Presentation transcript:

Fire Shelters What is so new about the New Generation Fire Shelter

Standard Fire Shelter Developed in 1960s Laminate of fiberglass and aluminum foil Designed to reflect radiant heat Rapidly damaged by flames

Standard Fire Shelter Deployed more than 1,100 times ½ Precautionary ¼ Prevented serious burns ¼ Saved life of occupant Approximately 20 fatalities

Fire Shelter Development 1999: Discovery of potential flammability Response: New training materials January 2000 – MTDC is asked to develop new shelter

Santiago Shelter Deployment

Additional Training This training class is additional information regarding the new generation fire shelter. It is not designed to be used as initial fire shelter training or solely as the training you need to meet annual requirements. Practicing with your fire shelter is part of the annual wildland refresher requirement. If you need initial training, please contact the Training Division or your supervisor.

Supporting Documents Briefing Paper Firefighters Concerned About Fire Shelter Length Tony Petrilli – Fire Shelter Project Leader – MTDC April 14, 2008

Basic Design The new shelter has a dome design instead of the tent design previously used This new shape is more aerodynamic and rounded to better reflect radiant heat

New Shelter Design More efficient use of material Shape to minimize absorption of radiant heat Allows person to lie prone

New Shelter Design Rounder shape Rounded ends scatter radiant heat Although it has less airspace, it performs better than the old-style shelter

Radiant Heat Internal temperatures in radiant heat tests. The new generation shelter will have less heat impact inside from the radiant heat It is still temperatures that may cause burns

It is much worse outside! Remember to stay inside your shelter until conditions have greatly improved on the outside. Some firefighters have lost their lives leaving their shelters too soon.

Direct Flame Contact Internal temperatures in direct flame tests. The flames burned through the old-style shelter within 15 sec.

Touching Shelter Material With less airspace, some firefighters are concerned about the hot shelter material touching them during deployment. During tests the shelter was exposed to direct flame contact between 1,472° F to 1,652° Fahrenheit. After 7 seconds of flame contact the inner surface was 376° F. After 18 seconds the inner surface temperature reached 318°

Direct Flame Impingment The material of the new shelter remained intact and provided protection from the flames for the duration of the 1 minute test. The old shelter when tested allowed flames to enter the shelter after 15 seconds.

Other Design Features Deployment Handles make it easier to hold while deploying in extreme winds. Hold down straps to keep shelter in place during deployments The new quick pull strap was designed to help remove the shelter from its case.

Two Sizes The new shelters are not one size fits all. Regular and Large. The Large shelter has an orange pull strap and has the word LARGE stenciled on the end of the strap.

Sizing

You should be able to… Lie face down inside the shelter while wearing a hardhat and boots without pushing against the ends of the shelter. Lie in the shelter with your arms through the hold down straps. Fold your elbows next to your chest and protect the sides of your face with your hands with only minimal contact with the sides of the shelter.

Shelters Dimensions

Recommendations Any firefighter taller than 6 feet 1 inch should carry the large shelter. Any firefighter whose girth is larger than 53 inches at any point should also carry the large shelter. Those shorter than 5 7 should carry the regular size. These measurements should include your height with helmet and boots on.

What is best for you? For those firefighters in between, it is their choice of which size to carry. See the information in the supporting documents to find out what size fire shelter you should wear! Practice deploying both size shelters under varying conditions to determine which size is best for you.

Too Short….. It is important to recognize that shorter people have much more difficulty deploying and holding down the large size fire shelter, especially in high winds. While extra air space does provide more protection, being unable to hold down a large shelter could result in catastrophic injury or death.

New vs. Old Shelter

Case Studies Fire Shelter Deployments

Alabaugh Fire In this deployment, two firefighters shared one regular size New Generation Fire Shelter. Before entering the shelter both firefighters were receiving burns. After entering the shelter they received no further burns even though they had extensive direct contact with the shelter material. Both firefighters felt that the fire shelter saved their lives.

Recommendations One of the recommendations from the Alabaugh Fire Shelter Deployment Report was that firefighters practice deployments with an actual New Generation Fire Shelter in order to become as proficient as possible. This would also give firefighters the most realistic expectations and training for a potential shelter deployment.

Little Venus Fire This report shows photos of the deployment with firefighters inside both old-style and new shelters. The firefighters, varying in height and weight, reported contact with shelter material in both old-style and new style fire shelters. Whichever shelter (old or new) or size, there will be contact with shelter material while a firefighter is deployed in a shelter.

Injuries This translated into a burn injury for only one firefighter; the firefighter who carried an old-style shelter with a 43-inch tear received a ½ inch blister where his elbow pressed against the material. The firefighters credited the fire shelters with saving their lives.

Little Venus Fire Deployment

Both of these reports are available in the additional resources section at the end of this presentation

Your Fire Shelter New Generation Fire Shelter Training Click Here for textbookClick Here for video

Refolding Procedures Used on Practice Fire Shelters

Refolding the Practice Shelter

Additional Resources

The End