SYNCHRONOUS MACHINES - Open circuit & Short circuit tests -

Slides:



Advertisements
Similar presentations
The stator winding are supplied with balanced three-phase AC voltage, which produce induced voltage in the rotor windings. It is possible to arrange the.
Advertisements

ENERGY CONVERSION ONE (Course 25741)
Synchronous Machines (AC Generators)
CHAPTER-FIVE Synchronous Machines
Power System Fundamentals
Chapter 4 Synchronous Generators
Two-pole,3-phase,wye-connected,salient-pole synchronous machine
SYNCHRONOUS MACHINES SUBMITTED BY: Ms. APOORVA KANTHWAL
Synchronous Machines.
SYNCHRONOUS GENERATORS
SEE 3433 MESIN ELEKTRIK SYNCHRONOUS MACHINES - Equivalent circuit - - Phasor diagrams -
SEE 3433 ELECTRICAL MACHINES Classification of DC machines DC Generators - Separately excited - Armature reaction.
Three-Phase Induction Motor Stator. Three-Phase Alternating Current.
SEE 3433 MESIN ELEKTRIK SYNCHRONOUS MACHINES Basic principles.
Lesson 37 AC Generators II
Induced emf Developed torque Magnetization curve SEE 3433 ELECTRICAL MACHINES.
Hysteresis Motors Stator Rotor same as for induction motor
SYNCHRONOUS MACHINES - Open circuit & Short circuit tests -
Mehran University College Of Engineering & Technology, Khairpur Mir’s ENGR. AHSANULLAH MEMON LECTURER DEPARTMENT OF ELECTRICAL ENGINEERING MUCET KHAIRPUR.
Synchronous Generator
EQUIVALENT CIRCUIT AND POWER EQUATION OF SYNCHRONOUS MOTOR
Synchronous Motors When a synchronous machine is used as a motor, it is not self-starting. If the rotor field poles are excited by the field current and.
ET 332a Dc Motors, Generators and Energy Conversion Devices 1Lesson a.pptx.
Department of Electrical and Computer Engineering
5.1 INTRODUCTION TO POLYPHASE SYNCHRONOUS MACHINES
Synchronous Machine The outline of the pole shoes is shaped in such a way that the vectorial lines have such lengths to provide an almost sinusoidal induction.
AC Machines Fundamentals. Introduction Synchronous machines: Motors and generators whose magnetic field is supplied by a separate dc power supply. Induction.
The Magnetic Field of Synchronous Machines: Slides to Complement Class Notes by Constantine J. Hatziadoniu.
EET 221 Synchronous Machines Rafiqi.
Motors and Generators.
ECE 576 – Power System Dynamics and Stability Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign.
BASIC ELECTRICAL TECHNOLOGY DET 211/3
Induction motor National Research Tomsk Polytechnic University Student: R.N.Kalimbekov Group 5GM42 Teacher: O.S.Kachin Tomsk 2015.
EEE223 Energy Conversion II Md. Asif Uddin Khan Lecturer, EEE BRAC University 1.
INTRODUCTION A 3-phase induction motor cannot be operated at variable speed. 1-phase induction motor is not self starting. Thus, A.C. commutator motors.
Magnetic Circuits and Magnetic Materials
Synchronous Generator
DC GENERATORS Introduction The outstanding advantages of dc machines arise from the wide variety of operating characteristics which can be obtained by.
Lecture 31Electro Mechanical System1 Field Excitation The dc field excitation of a large synchronous generator is an important part of its overall design.
SYNCHRONOUS MACHINES Output Equation Q = m Eph Iph 10-3 = 11 Bave ac Kw x 10-3 D2L ns = Co D2L ns Where Co = output coefficient (see Unit -4 for derivation)
SYNCHRONOUS GENERATOR
Lesson 18 Synchronous Motor Operation and Applications
PREPARED BY: Group-D Ramavat Nikunj ( )
Chapter 5: Speed-Torque Characteristics of Electric Motors
Voltage Regulation.
Lesson 34: AC Generators II
ECEN 460 Power System Operation and Control
Chapter 6: DC & AC Machine
Module G1 Electric Power Generation and Machine Controls
Principle of Operation
SPEED TORQUE CHARACTERSTICS OF 3 PHASE INDUCTION MOTOR
Lesson 23: Synchronous Alternator Voltage Regulation
SPEED TORQUE CHARACTERSTICS OF 3 PHASE INDUCTION MOTOR
Synchronous Motor Principle and basics.
Synchronous Motors and Generators
Electrical Machines-II
Synchronous Machines.
ECEN 460 Power System Operation and Control
SYNCHRONOUS MACHINES Basic principles
EE216 Electrical Engineering
Permanent Magnet Synchronous Motors
Principle of Operation
ECE 576 POWER SYSTEM DYNAMICS AND STABILITY
TOPIC: ROTATING MAGNETIC FIELD DEPT: EEE
TOPIC: ROTATING MAGNETIC FIELD DEPT: EEE
EET 306 Synchronous Machines
Electrical Machines (EELE 3351)
SYNCHRONOUS MACHINES - Equivalent circuit - - Phasor diagrams -
SYNCHRONOUS MACHINES Power and Torque Characteristics
Electric Machine Design Course
Presentation transcript:

SYNCHRONOUS MACHINES - Open circuit & Short circuit tests - SEE 3433 MESIN ELEKTRIK SYNCHRONOUS MACHINES - Open circuit & Short circuit tests -

These tests are conducted to determine the synchronous reactance of a synchronous machine Conducted in SEE 3742 Electrical Machine Laboratory

Stator terminals open  Ia = 0  Vt = Ef Open-circuit test Open Circuit Characteristic (OCC) Rotor runs at constant speed – field current adjusted  Ef depends only on flux per pole or If Stator terminals open  Ia = 0  Vt = Ef Air-gap line Ef, Modified air-gap line Excitation voltage with no saturation OCC Vt,rated Magnetic saturation If

No saturation since airgap flux is small Short-circuit test Short Circuit Characteristic (SCC) Rotor runs at synchronous speed - stator terminals shorted – stator current plotted against If No saturation since airgap flux is small Ef, Ia OCC Vt,rated SCC If

Determining Xs OCC Vt,rated Ef, If Ia SCC

Determining Xs If’’ If’ Synchronous reactance, Xs = Ia,rated Ia’ Ef, OCC Vt,rated SCC Ia,rated If’’ Ia’ If Synchronous reactance, Xs =