Indications and Technique of Implantation of the BioIntegral No-React BioConduit for Bentall Procedure.

Slides:



Advertisements
Similar presentations
Pericardial stentless bioprosthesis Preliminary results of a modified procedure for implantation Y. De Bruyne, B. El Nakadi & M. Joris Hopitaux civils.
Advertisements

Aortic Valve Repair. Aortic Root Annulus Cusp Sinus ST junction Sub Commissure Triangle.
One-stage repair for Stanford Type B Aortic Dissection concomitant with cardiac diseases Open stented elephant trunk technique combined with cardiac operation.
Ross Operation Seoul National University Hospital Department of Thoracic & Cardiovascular Surgery.
Date of download: 9/18/2016 Copyright © 2016 McGraw-Hill Education. All rights reserved. Reimplantation (David-I) valve-sparing aortic root replacement-
Shunji Sano, MD, Kozo Ishino, MD, Masaaki Kawada, MD, Osami Honjo, MD 
Concomitant valve sparing root remodeling with extra aortic ring annuloplasty and e-vita stented elephant trunk implantation Igor Rudez, Marko Kusurin,
An Appraisal of the Ross Procedure: Goals and Technical Guidelines
Technique of Mechanical Pulmonary Valve Replacement
Ronald C. Elkins  Operative Techniques in Cardiac and Thoracic Surgery 
The Syncardia Total Artificial Heart: Implantation Technique
Reinforcement of the Pulmonary Autograft with a Prosthetic Graft to Prevent Dilatation After the Ross Procedure  Thierry Carrel, MD, Florian Schönhoff,
Surgical Treatment of Anomalous Aortic Origin of Coronary Arteries: The Reimplantation Technique and Its Modifications  Thierry Carrel, MD  Operative.
Coronary Artery from the Wrong Sinus of Valsalva: A Physiologic Repair Strategy  Tom R. Karl, MS, MD  Operative Techniques in Thoracic and Cardiovascular.
The Completion Bentall Procedure
Heterotopic Heart Transplantation: Technical Considerations
The Arterial Switch Operation: The “Open” Technique for Coronary Transfer  Joseph M. Forbess, MD  Operative Techniques in Thoracic and Cardiovascular Surgery 
Surgical Unroofing for Anomalous Aortic Origin of Coronary Arteries
Surgery for Acute Type A Aortic Dissection
Surgery for Aortic Valve Endocarditis
Richard J. Myung, MD, Michael E. Halkos, MD, John D. Puskas, MD 
Edward H. Kincaid, MD, Neal D. Kon, MD 
Modified button-Bentall operation for aortic root replacement: the miniskirt technique  Guido Michielon, MD, Loris Salvador, MD, Uberto Da Col, MD, Carlo.
Right Ventricular Outflow Reconstruction Using a Polytetrafluoroethylene Conduit With Bulging Sinuses and Tricuspid Fan-shaped Polytetrafluoroethylene.
The Arterial Switch Procedure: Closed Coronary Artery Transfer
En-bloc Rotation of the Truncus Arteriosus—A Technique for Complete Anatomic Repair of Transposition of the Great Arteries/Ventricular Septal Defect/Left.
Transventricular Repair of Tetralogy of Fallot
Shunji Sano, MD, Kozo Ishino, MD, Masaaki Kawada, MD, Osami Honjo, MD 
Surgical Correction of Congenital Supravalvular Aortic Stenosis
Pulmonary Valve Preservation Strategies for Tetralogy of Fallot Repair
Aortic Valve Replacement with Pulmonary Autograft: Subcoronary and Aortic Root Inclusion Techniques  Tirone E. David, MD  Operative Techniques in Thoracic.
The Syncardia Total Artificial Heart: Implantation Technique
Extra-anatomic Bypass Graft for Recurrent Aortic Arch Obstruction
Osami Honjo, MD, PhD, Vivek Rao, MD 
Novel sutureless telescoping anastomosis revascularization technique of supra-aortic vessels to simplify combined open endovascular procedures in the.
Repair of Tetralogy of Fallot with Absent Pulmonary Valve Syndrome
Aortic Valve Reimplantation According to the David Type I Technique
Aditya K. Kaza, MD, Phillip T. Burch, MD, John A. Hawkins, MD 
Aortic Valve Replacement with the Medtronic Freestyle Xenograft Using the Subcoronary Implantation Technique  D. Michael Deeb, MD  Operative Techniques.
The Ross/Konno Procedure
John R. Doty, MD, Donald B. Doty, MD 
Surgical Options for Discrete Supravalvar Aortic Stenosis
Toward more reliable repair of ruptured sinus of Valsalva
Valve-Conserving Operation for Aortic Root Aneurysm or Dissection
Repair of Anomalous Coronary Artery From the Pulmonary Artery by Aortic Implantation  Anthony Azakie, MD  Operative Techniques in Thoracic and Cardiovascular.
Technique of Mechanical Pulmonary Valve Replacement
Implant Technique for the Sorin Stentless Pericardial Valve
Extracardiac Conduit Total Cavopulmonary Anastomosis
Wolfgang F. Konertz, Alexandros Sidiropoulos, Jianshi Liu 
Remodeling the Aortic Root and Preservation of the Native Aortic Valve
Implantation of the Jarvik 2000 Heart
Inclusion or Mini-root Homograft Aortic Valve Replacement
Implant Technique for the Freestyle Stentless Bioprosthesis
Christian Kreutzer, Christian Blunda, Guillermo Kreutzer, Andres J
Implant Technique for the Freestyle Stentless Bioprosthesis
G. Chad Hughes, MD, Madhav Swaminathan, MD, Walter G. Wolfe, MD 
Aortic Valve Replacement With the Toronto SPV Bioprosthesis
Ronald C. Elkins  Operative Techniques in Cardiac and Thoracic Surgery 
Ross Procedure With Enlargement Ammloplasty
Endocarditis with Involvement of the Aorto-Mitral Curtain
Valve-sparing root repair: V-shaped remodeling can be performed in all sinuses  Paul P. Urbanski, MD, PhD  The Journal of Thoracic and Cardiovascular Surgery 
Transposition of the Great Arteries
Outcome After the Modified Bentall Technique With a Long Interposed Graft to the Left Coronary Artery  Atsushi Nakahira, MD, Toshihiko Shibata, MD, PhD,
Novel Technique of Valve-Sparing Aortic Root Replacement in Two Children Younger Than 3 Years of Age  James K. Kirklin, MD, Walter H. Johnson, MD, Barton.
Stage I—The Philadelphia Approach
William F Northrup, MD, Vibhu R Kshettry, MD 
David J. Kaczorowski, MD, Y. Joseph Woo, MD 
Anomalous origin of the left coronary artery from the pulmonary artery: collective review of surgical therapy  Ali Dodge-Khatami, MD, Constantine Mavroudis,
Repair of Anomalous Coronary Artery From the Pulmonary Artery by Aortic Implantation  Anthony Azakie, MD  Operative Techniques in Thoracic and Cardiovascular.
Jared P. Beller, MD, Emily A. Downs, MD, Curtis G. Tribble, MD 
Presentation transcript:

Indications and Technique of Implantation of the BioIntegral No-React BioConduit for Bentall Procedure

Indications Endocarditis combined with aneurysm of the ascending aorta Marphan syndrome combined with AR and dilatation of the aorta at any age Infected graft conduit Older patients when there is a need to minimize bleeding Young patients to replace Ross Procedure

Indications Why No-React BioConduit for young patients? Why to replace Ross Procedure? No-React valves and conduit found to resist infection, calcification, and remodeling in long-term clinical follow-up Pulmonic autograft in Ross Procedure is now known to dilate significantly because of remodeling that starts after 3 years, while No-React BioConduit resists dilatation beyond 10 years at any age

Technique of Implantation Patient on CPB Distal cross-clamp Resect the aneurysm (above the coronary Ostia) & de-calcify if necessary Figure 1

Technique of Implantation Implanting the annulus of the NR-BioConduit The suture line of the BioConduit must face the non-coronary cusp The pericardial annulus of the BioConduit can be sutured with interrupted suture to the aortic annulus (2.0 polyester suture) Or continuous 3.0 or 4.0 monofilament suture. Advisable to start with 3 commissural site sutures and then run in between – see video Figure 2

Technique of Implantation Suturing the Coronary Button Introduce a right angle clamp and apply outside pressure in the inter-commissural space Perforate the pericardium with a knife over the right angle guidance Figure 3

Technique of Implantation Suturing the Coronary Button 3. Complete the round perforation with an aortic punch or scissors as shown in the figure Figure 4

Technique of Implantation Suturing the Coronary Button Suture the coronary left and right Ostia to the perforated respective orifice using a continuous 5-0 monofilament suture Figure 5

Technique of Implantation Distal Anastomosis Transect the conduit in the appropriate length (see video) Suture the distal part of the conduit to the distal aorta near the clamp using 3.0 or 4.0 monofilament (remember use 2-3mm close bites to assure 100% hemostasis) Figure 6

Technique of Implantation Distal Anastomosis Let the conduit fill with blood and close the anastomosis WARNING: any anastomotic bleeding when the patient is off bypass must be secured with 5-0 or 6-0 proline, no oozing permissible, and do not use any aldehyde glue Figure 7

Technique of Implantation De-clamping Before you remove the aortic clamp, you can de-air the aorta with a needle Remove the clamp, and you are ready to go off bypass Figure 8

Technique of Implantation De-clamping If the diameter of the aorta is larger than the conduit, anastamosis is completed as far is possible and the remaining defect is closed with a No-React pericardial patch (pericardium trimmed from distal end of conduit) Figure 9