CMS Pixel Data Quality Monitoring

Slides:



Advertisements
Similar presentations
23/04/2008VLVnT08, Toulon, FR, April 2008, M. Stavrianakou, NESTOR-NOA 1 First thoughts for KM3Net on-shore data storage and distribution Facilities VLV.
Advertisements

Far Detector Data Quality Andy Blake Cambridge University.
1 HLT – a source of calibration data One of the main tasks of HLT (especially in the first years) –Monitoring of the detector performance –Analysing calibration.
SCT Analyses on Cosmics. Efficiency 2 methods –Online- quick/biased -> located in SCT_Monitoring –Offline- slow/unbiased In agreement with each other.
Data Quality Monitoring for CMS RPC A. Cimmino, D. Lomidze P. Noli, M. Maggi, P. Paolucci.
7/19/2004FTPC Review - J. Seyboth1 FTPC Review - Software Janet Seyboth for the FTPC group DAQ Online Calibration Databases Offline Documentation FTPC.
Data Quality Monitoring of the CMS Tracker
1 TPC online  offline calibration November 2002.
SSD Status P. Christakoglou (NIKHEF-UU) for the SSD collaboration Thanks to: Marco vL, Enrico, Mino, Marek and Massimo.
Central DQM Shift Tutorial Online/Offline. Overview of the CMS DAQ and useful terminology 2 Detector signals are collected through individual data acquisition.
SVX Software Overview Sasha Lebedev VTX meeting 09/07/ SVX Software web page:
RPC Readiness for Data-taking RPC Collaboration 1.
Craft09 Visual Summary and Efficiency Trackermaps Giuseppe Zito : Infn Bari Italy Giuseppe Zito, Infn Bari.
Offline Tracker DQM Shift Tutorial. 29/19/20152 Tracker Shifts Overview Online Shifts at P5 (3/day for 24 hours coverage) – One Pixel shifter and one.
06/03/06Calice TB preparation1 HCAL test beam monitoring - online plots & fast analysis - - what do we want to monitor - how do we want to store & communicate.
Simulation issue Y. Akiba. Main goals stated in LOI Measurement of charm and beauty using DCA in barrel –c  e + X –D  K , K , etc –b  e + X –B 
Some notes on ezTree and EMC data in MuDst Marco van Leeuwen, LBNL.
STAR Analysis Meeting, BNL, Dec 2004 Alexandre A. P. Suaide University of Sao Paulo Slide 1 BEMC software and calibration L3 display 200 GeV February.
Thomas Jefferson National Accelerator Facility Page 1 EC / PCAL ENERGY CALIBRATION Cole Smith UVA PCAL EC Outline Why 2 calorimeters? Requirements Using.
RPC DQA but also Monitoring for the DCS group: status and prospective for Marcello Bindi RPC L1MU Barrel DQM - 08/05/2013.
11 Sep 2009Paul Dauncey1 TPAC test beam analysis tasks Paul Dauncey.
CMS pixel data quality monitoring Petra Merkel, Purdue University For the CMS Pixel DQM Group Vertex 2008, Sweden.
STAR Collaboration Meeting, BNL, Feb 2005 Alexandre A. P. Suaide University of Sao Paulo Slide 1 BEMC software update L3 display 200 GeV February.
4 th Workshop on ALICE Installation and Commissioning January 16 th & 17 th, CERN Muon Tracking (MUON_TRK, MCH, MTRK) Conclusion of the first ALICE COSMIC.
1 ITS Quality Assurance (& DQM) P. Cerello, P. Christakoglou, W. Ferrarese, M. Nicassio, M. Siciliano ALICE OFFLINE WEEK – April 2008.
ALICE Pixel Operational Experience R. Santoro On behalf of the ITS collaboration in the ALICE experiment at LHC.
Tracker Visualization Tool: integration in ORCA Maria S. Mennea, Giuseppe Zito University & INFN Bari, Italy Tracker b-tau Cosmic Challenge preparation.
LM Feb SSD status and Plans for Year 5 Lilian Martin - SUBATECH STAR Collaboration Meeting BNL - February 2005.
RPC DQM status Cimmino, M. Maggi, P. Noli, D. Lomidze, P. Paolucci, G. Roselli, C. Carillo.
Data Quality Monitoring for the CMS Resistive Plate Chamber Detector Anna Cimmino etc etc etc Università degli Studi di Napoli “ Federico II ” & INFN of.
Online (GNAM) and offline (Express Stream and Tier0) monitoring produced results during cosmic/collision runs (Oct-Dec 2009) Shifter and expert level monitoring.
1 Checks on SDD Data Piergiorgio Cerello, Francesco Prino, Melinda Siciliano.
1 SDD offline status Francesco Prino INFN sezione di Torino ALICE offline week – March 15th 2010.
Pixel DQM Status R.Casagrande, P.Merkel, J.Zablocki (Purdue University) D.Duggan, D.Hidas, K.Rose (Rutgers University) L.Wehrli (ETH Zuerich) A.York (University.
DQM for the RPC subdetector M. Maggi and P. Paolucci.
Online Monitoring System at KLOE Alessandra Doria INFN - Napoli for the KLOE collaboration CHEP 2000 Padova, 7-11 February 2000 NAPOLI.
GLAST LAT Project CU Beam Test Workshop 3/20/2006 C. Sgro’, L. Baldini, J. Bregeon1 Glast LAT Calibration Unit Beam Test Status Report on Online Monitor.
5-9 June 2006Erika Garutti - CALOR CALICE scintillator HCAL commissioning experience and test beam program Erika Garutti On behalf of the CALICE.
2/18/2016I. Ravinovich1 HBD Run-10 data analysis I. Ravinovich WIS.
Quality assurance for TPC. Quality assurance ● Process: ● Detect the problems ● Define, what is the problem ● What do we expect? ● Defined in the TDR.
DQM for the RPC subdetector M. Maggi and P. Paolucci.
Online Consumers produce histograms (from a limited sample of events) which provide information about the status of the different sub-detectors. The DQM.
Валидация TRT DCS CONDITIONS SERVICE Евгений Солдатов, НИЯУ МИФИ “Physics&Computing in ATLAS” – 22/09/2010.
ID Week 13 th of October 2014 Per Johansson Sheffield University.
Calibration algorithm and detector monitoring - TPC Marian Ivanov.
1 Outline First look at the 2007 data with the offline reconstruction (~1000evts) : –Clusters. –Reconstructed Space points. FastOffline plots: –2 differents.
D. Elia (INFN Bari)Offline week / CERN Status of the SPD Offline Domenico Elia (INFN Bari) Overview:  Response simulation (timing info, dead/noisy.
Noise results from SR1 combined SCT barrel tests Summary of some initial results Alan Barr, UCL Pepe Bernabeu, Valencia.
General online meeting SLAC Nov 4, 1999 G.Crosetti, M.Lo Vetere, E.Robutti IFR online calibrations status and plans.
ECAL Shift Duty: A Beginners Guide By Pourus Mehta.
Custom Classes DetectorShapeView2D: Detector mouseover callbacks (default is mouse click). EventControl:
Track reconstruction of cosmic ray real data with the CMS tracker Piergiulio Lenzi Dipartimento di Fisica & INFN Firenze on behalf of the Silicon Strip.
UA - Antwerp - 21/04/09 Romain Rougny (CMS)‏1/16 Final Pixel CRAFT results Pixel General Meeting Romain Rougny, University of Antwerpen.
Central DQM Shift Tutorial Online/Offline
RPC Data Certification
EUTelescope Testbeam Analysis: Summer 2014
Srećko Morović Institute Ruđer Bošković
Calibrating ALICE.
Offline shifter training tutorial
Commissioning of the ALICE HLT, TPC and PHOS systems
Pixel DQM Status & Plans
Online SW, DB & Calibration
Data Quality Monitoring of the CMS Silicon Strip Tracker Detector
Scott D. Metzler California Institute of Technology
Central DQM Shift Tutorial Online/Offline
Test Beam Measurements october – november, 2016
Status of RPC DQM for Global DAQ in CMSSW
DQM for the RPC subdetector
CMS Pixel Data Quality Monitoring
Drift Chamber Monitoring
Presentation transcript:

CMS Pixel Data Quality Monitoring Petra Merkel Purdue University, West Lafayette, IN, USA For the CMS Pixel Group Interactive SVG Maps The Data Quality Monitoring (DQM) system in the CMS experiment has been developed within the CMS Software framework. It has been designed to be used during online data taking as well as during offline reconstruction. The goal of the online system is to minimize data loss due to wrong detector configurations and malfunctioning components. On the other hand the reconstruction or calibration problems can be detected during offline processing using the same tools. All histograms can be displayed both in the central CMS DQM graphical user interface (GUI), as well as in the Pixel specific expert GUI and in geometrical, interactive maps. Investigate with expert GUI Module with most entries  noisy pixel(s)? Expert DQM GUI Navigate detector Hierarchy to pin point Noisy module The monitoring is performed with histograms, which are filled with information from raw and reconstructed data, summary and overview plots are created, and automated statistical tests are applied. In particular we monitor readout errors, raw charge deposition information, as well as reconstructed hits, both on and off tracks. Thus, we are able to detect data corruption, mis-configuration and mis-calibration of the detector, as well as newly broken modules and dead or noisy pixels. Mean cluster charge [ke-] Endcap modules Clusters: gain calibrated, clustered charges Occupancy map Digis: raw single pixel charges LIVE Plot noisy module’s Raw charge Barrel modules Mean number of Rechits Rechits: Lorentz drift corrected reconstructed hits Data corruption & Readout errors Error map Check which pixels fired A handful of noisy pixels! Reduced statistics (~5Hz), full granularity, Fast feed back to detector Feed back to detector: e.g. mask noisy pixels Fill and investigate online plots, Automatically & by expert & 1440 modules 66M pixels No errors Feed back to detector, calibration and reco groups Offline shifter Fill and investigate offline plots, Automatically & by expert Full calibration, alignment, reconstruction & statistics Reduced granularity Trend monitoring Run number OFFLINE Data Certification Algorithms & cuts Pixel Barrel and Endcap Good run flags for Physics Analyses DQM good run flag (fraction of modules passing cuts) Data base DAQ good run flag (fraction of pixel modules in read out) DCS good run flag (fraction of pixel modules powered up) In order to certify the data for Physics analyses a complex workflow has been put in place. Within the DQM framework a multitude of quantities concerning the data from the Pixel detector are filled into histograms for various steps in time, ranging from a few minutes, over once per run to trend plots spanning weeks or even months. Some of these histograms are automatically being compared to reference histograms, while from others, like the raw charge or reconstructed hit occupancy we extract the average values and apply cuts to them in order to automatically spot outliers and unexpected behaviour. The results of this evaluation are then combined to a final Data Quality Flag, which is stored for each run into a data base.