AGATA week Uppsala, July 2008

Slides:



Advertisements
Similar presentations
Applications of Nuclear Physics Applications of Nuclear Physics (Instrumentation) Dr Andy Boston Frontiers of gamma-ray spectroscopy.
Advertisements

Detector Characterisation Group
Advanced GAmma Tracking Array
PET Design: Simulation Studies using GEANT4 and GATE - Status Report - Martin Göttlich DESY.
Semiconductor detectors for Compton imaging in nuclear medicine
SmartPET: A Small Animal PET Demonstrator using HyperPure germanium Planar Detectors R. Cooper 1 st year PhD Student
Figure 5. Histogram of the decay constant. Black curves: raw histograms; Blue curve: Gaussian fit to the histogram from the 20GS/s waveform; Red curve:
Pulse Shape Analysis with Segmented Germanium Detector Xiang Liu, Max-Planck-Institut für Physik 1.Motivation 2.Pulse properties 3.Analysis procedure 4.Some.
AGATA Introduction John Simpson Nuclear Physics Group.
Design and First Results of a Cosmic Ray Telescope For Use In Testing a Focusing DIRC M. P. Belhorn University of Cincinnati The BELLE group at the University.
Compton Identification Within Single ‘Pixels’ D. Scraggs, A. Boston, H. Boston, R. Cooper, J. Cresswell, A. Grint, A. Mather, P. Nolan University of Liverpool.
Signal Analysis and Processing David Scraggs. Overview Introduction to Position Resolution Induced Charges Wavelet Transform Future Work Discussion.
1 A Design of PET detector using Microchannel Plate PMT with Transmission Line Readout Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat.
Anthony Sweeney Position Sensitive Detectors 9 Aberystwyth 2011.
Depletion Region Dynamics of an AGATA Detector Steven Moon University of Liverpool UNTF 2010, University of Salford 14 th -16 nd April 2010.
AGATA 2 nd Prototype Detector Initial Measurements & Evaluation Andrew Boston, Matthew Dimmock, Laura Nelson, Sarah Rigby.
Characterisation & PSA Team Meeting Presentations –Liverpool Status, Andy Boston/Matt Dimmock (Liverpool) –Crosstalk properties of AGATA detectors, Bart.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
The PEPPo e - & e + polarization measurements E. Fanchini On behalf of the PEPPo collaboration POSIPOL 2012 Zeuthen 4-6 September E. Fanchini -Posipol.
Diana Parno – July 22, 2008 January PREx Test Run: Compton Photon Analysis Diana Parno Carnegie Mellon University HAPPEX Collaboration Meeting.
Detectors and Preamplifiers Detector deliveries Customer Acceptance Tests Available detectors AGATA triple detectors Scanning program P. Reiter IKP University.
ArgonneBeamTest_ ppt1 Argonne Beam Test preparation Tsunefumi Mizuno Tuneyoshi Kamae
Wolfram KORTEN, JRA-02 AGATAEURONS PCC-Meeting, Mainz (Germany), April 2006 Status of the AGATA project Recent developments Milestones and deliverables.
Status of Møller Polarimeter Peter-Bernd Otte September 23, th Collaboration Meeting, Mainz.
Surface events suppression in the germanium bolometers EDELWEISS experiment Xavier-François Navick (CEA Dapnia) TAUP Sendai September 07.
We report the result of a beam test on a prototype of Astronomical hard X-ray/soft gamma-ray Polarimeter, PoGO (Polarized Gamma-ray Observer). PoGO is.
Concept of the scanning table in Strasbourg François DIDIERJEAN Tatjana FAUL, Fabrice STEHLIN Strasbourg AGATA week July 2008 Uppsala, Sweden.
Pedro Arce Introducción a GEANT4 1 GAMOS tutorial Compton Camera Exercises
On the origin of Differential Crosstalk in segmented detectors B. Bruyneel for the AGATA week, Uppsala, Sweden July 2008.
Analysis of S002 scan data Bart Bruyneel and Benedikt Birkenbach – IKP Cologne At the 7 th AGATA week, Uppsala July S003.
 -tracking uses segmented detectors which are characterized by xTalk  Traces are modified in shape and amplitude  Energy effects: peak shifts and resolution.
DESPEC A Algora IFIC (Valencia) for the Ge array working group.
1 Geant4 Simulation :MCP PET 4’’(102mm) Scintillator ( LSO) 4’’(102mm) 10mm Glass( Borosilicate) PhotocathodeI(Carbon) Space(Vacuum) MCP(Alumina) Space(Vacumm)
Experimental Nuclear Physics Some Recent Activities 1.Development of a detector for low-energy neutrons a. Hardware -- A Novel Design Idea b. Measure the.
Experiment TGV II Multi-detector HPGe telescopic spectrometer for the study of double beta processes of 106 Cd and 48 Ca For TGV collaboration: JINR Dubna,
LENS:  LENS Simulations, Analysis, and Results B. Charles Rasco Louisiana State University on behalf of the LENS Collaboration.
Development of a Segmented Planar Germanium Imaging Detector
Timing Studies of Hamamatsu MPPCs and MEPhI SiPM Samples Bob Wagner, Gary Drake, Patrick DeLurgio Argonne National Laboratory Qingguo Xie Department of.
Timing in Thick Silicon Detectors Andrej Studen, University of Michigan, CIMA collaboration.
Some feedbacks from DRS data analysis (very preliminary) F. Scuri - I.N.F.N Sezione di Pisa RD52 – Collaboration Meeting – Pavia, March 12, 2013 F. Scuri.
A Prototype Diamond Detector for the Compton Polarimeter in Jefferson lab, Hall C Medium Energy Physics Group Amrendra.
Detector Module Three 36-fold segmented detectors 111 preamplifiers Cryostat Jürgen Eberth University of Cologne Detector Team: Dirk Weißhaar Preampl.
PSA: ADAPTIVE GRID SEARCH The Method Experimental Results Optimization aspects Roberto Venturelli (INFN Padova - IPSIA “Giorgi” Verona) SACLAY, 05-may-06.
AGATA Detector Meeting March 16th, 2006, Cologne Detector Acceptance Tests: delivered: three symmetric detectors S001 properties excellent S002 properties.
Steven Moon, A.J. Boston, H. Boston, J. Cresswell, L. Harkness, D. Judson, P.J. Nolan PSD9, Aberystwyth, Wales th September 2011 Compton imaging.
A Multi-Threshold Method for TOF-PET Signal Processing Heejong Kim 1, Chien-Min Kao 1, Qingguo Xie 1, Chin-Tu Chen 1, Octavia Biris 2, Jialin Lin 2, Fukun.
Testbeam analysis Lesya Shchutska. 2 beam telescope ECAL trigger  Prototype: short bars (3×7.35×114 mm 3 ), W absorber, 21 layer, 18 X 0  Readout: Signal.
ArgonneResult_ ppt1 Comparison of data and simulation of Argonne Beam Test July 10, 2004 Tsunefumi Mizuno
CdTe prototype detector testing Anja Schubert The University of Melbourne 9 May 2011 Updates.
ArgonneResult_ ppt1 Results of PoGO Argonne Beam Test PoGO Collaboration meeting at SLAC, February 7, 2004 Tsunefumi Mizuno
Neutrinoless double beta decay (0  ) CdTe Semico nductor Band gap (eV) Electron mobility (cm 2 /V/s) Hole mobility (cm 2 /V/s) Density (g/cm 3.
Advanced Gamma Tracking Array Andy Boston The Advanced Gamma Tracking Array
The Status of Hyperball-J Akio Sasaki Dept. of Phys. Tohoku Univ. 23/9/2011.
Characterisation of a pixellated CsI detector for the Distinguish Project. 1 Martin Jones The University of Liverpool
Silicon microstrip detector for imaging of fast processes at high intensity synchrotron radiation beam. Budker INP V.Aulchenko1,2, L.Shekhtman1,2, B.Tolochko3,2,
Detector characterization overview of the AGATA scanning tables
Charge collection studies with irradiated CMOS detectors
AGATA Advanced Gamma Tracking Array
Detectors and Preamplifiers
Development of a Compton Camera for online range monitoring
Natural CMO+HPGe experiment
AGATA Detector Work Performed at Saclay in lessons learned -
CAT of AGATA detectors &
SIGMA: a detector for γ-ray spectroscopy & imaging Dr Laura AGATA/GRETINA Collaboration Meeting
Preliminary Compton Imaging results of the AGATA C001 detector
MINOS: a new vertex tracker for in-flight γ-ray spectroscopy
Status report Detector team
ME instrument and in-orbit performance
GRETINA experiments with fast beams at NSCL
Gain measurements of Chromium GEM foils
Presentation transcript:

AGATA week Uppsala, July 2008 Singles and Coincidence Scanning of C001 in Liverpool AGATA week Uppsala, July 2008

Energy Resolution Measurements FWHM measured in Liverpool (top) at 60 keV (blue) and 1332 keV (red). C001 coupled to ORTEC 671 spectroscopy amplifier and ORTEC ADC. Count rate maintained below 2 kHz on core. These results are as good or better than those found in Cologne (bottom) Segment F4 missing from data due to broken connection between FET and preamp.

Scanning table Setup C001 mounted on coincidence scanning assembly. Collimated 137Cs source moved in x-y plane on Parker scanning table. Interaction position of 90˚ Compton scatter events identified through coincidence between C001 and scintillators mounted at 6 depths. When system is triggered all 37 signals are recorded in 128 12.5ns samples using 14 GRT4 cards.

Time Alignment Time alignment has been the limiting factor in analysis of scan data from symmetric prototype detectors. 3 AGATA signals per 4 channel GRT card. 1 channel per card fed with triangular pulser. After interpolation linear fit to both sides of pulse will identify peak sample. All signals then aligned to this point.

Segment Gated Intensity Number of counts at each scanning table position when 662 keV is deposited in a single segment during singles scanning.

Crystal Alignment Two methods applied to intensity map data to obtain crystal tilt. Method 1 finds the minimum bounding circle of points near centre which fall below threshold number of counts. Method 2 uses a cross correlation between the intensity map for each ring and an image of a single circle. 0.38 mm between centres of rings 2 – 6. 0.88 mm between centres of ring 1 and 2.

Core Risetimes (T30) t30 – t10 for fold 1 photopeak events. Fast axis (100) not aligned with any segment centre.

Core Risetimes (T90) t90 – t10 for fold 1 photopeak events. Weak field evident at corners of ring 1.

Segment Risetimes (T30) t30 – t10 for events when 662 keV deposited in one segment, for rings 1 to 6.

Segment Risetimes (T90) Long T90 at corners of ring 1 due to weak field.

Image Charge Asymmetry ICA = [1000 x (Aclock – Aanti) / (Aclock + Aanti)] + 1000 Reduced sensitivity in mid radius regions of segments.

Thank You Collaborators Mathew Dimmock Steve Barrett Andy Boston Helen Boston Ren Cooper John Creswell