Flow Cytometry and Sorting Part 3

Slides:



Advertisements
Similar presentations
Research Techniques Made Simple: Flow Cytometry Richard R
Advertisements

Slide 1, 4/12/2015 of DNA.ppt  Purdue University Cytometry Laboratories DNA1.ppt.
FLOW CYTOMETRIC ANALYSIS OF THE CELL CYCLE Jan Bartoš Laboratory of Molecular Cytogenetics and Cytometry Institute of Experimental Botany Olomouc, Czech.
What is Flow Cytometry? Introduction to Flow Cytometry
CHAPTER 37 MLAB 1415 HEMATOLOGY JOANNA ELLIS, MLS(ASCP) Optical Light Scatter and Flow Cytometry.
DCFH-DA DCFH-DA DCFH DCF H O Oxidative Burst.
FLOW CYTOMETRY Dr. MOHAMMED H SAIEMA LDAHR KAAU FACULTY OF APPLIED MEDICAL SCIENCES MEDICAL TECHNOLOGY DEPT. 2 ND YEAR MT INSTROMINTATION EXT
Flow Cytometry and Sorting Part 2 Lecture Notes for “Fluorescence Spectroscopy in Biological Research” Robert F. Murphy, October 1996.
Page 1 © J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT BMS 602/631 - LECTURE 8 Flow Cytometry: Theory J. Paul Robinson Professor.
Basics of Flow Cytometry Holden Maecker. Outline Definitions, what can be measured by flow cytometry Fluidics: Sheath and sample streams, flow cells,
What is Flow Cytometry? Flow Cytometry uic Introduction to Flow Cytometry IGC Workshop IGC – Nov 12, 2009 Cell Sorting.
Antigen antibody reactions
+ - Cell Sorting LASER. Cell Sorting + - LASER Zhang at al, Blood 2003, 102: Flow cytometry analysis of mouse fetal liver cells. Mouse fetal.
Flow Cytometry at Boston University Medical Campus Introduction to some methods that we offer Yan Deng (X4-5225), Gerald Denis (X4-1371),
Introduction To Flow Cytometry By Noha Kamel. Flow cytometry is a method of measuring multiple physical and chemical characteristics of particles by optical.
Basic Principles in Flow Cytometry
 Flow cytometry is a technique for counting, examining, and sorting microscopic particles suspended in a stream of fluid.
Basic Principles, Instrumentation, and Practices
Flow Cytometry Principles & practice of “Fluorescence Spectroscopy in Biological Diagnosis & Research” Dr.Hekmatimoghaddam Assistant professor of pathology.
Laser Flow Cytometry Forward Scatter indicates size Forward Scatter.
Flow Cytometry Basic Training. What Is Flow Cytometry? Flow ~ cells in motion Cyto ~ cell Metry ~ measure Measuring properties of cells while in a fluid.
Flow Cytometry (FCM) Yun-Ju Lee September 13, 2002.
1 Flow Cytometry in the Clinical Laboratory Patricia Aoun, M.D., M. P. H. Jean Bailey, MT-ASCP Kellie Neth, MT-ASCP The Nebraska Medical Center.
Flow Cytometry Becton Dickinson Asia Limited Company.
FACS & Cell Sorting Cell Isolation
PBS 7413 FLOW CYTOMETRY LABORATORY. COURSE OBJECTIVES 1.UNDERSTAND CLINICAL AND RESEARCH APPLICATIONS OF FLOW CYTOMETRY TECHNOLOGY 2.PERFORM STAINING.
Potential Applications of Flow Cytometry Cell activation statusCell activation status Cell cycle distributionCell cycle distribution Cell divisionCell.
F LUORESCENCE – A CTIVATED C ELL S ORTING Ana Luisa Caetano Unidade de Citometria de Fluxo Instituto de Medicina Molecular.
Fluorescence and Fluorochromes Peter O’Toole Tel:
Potential Applications of Flow Cytometry Cell activation statusCell activation status Cell cycle distributionCell cycle distribution Cell divisionCell.
Cell Cycle Analysis Tritiated (3H) Thymidine uptake was one of the first methods used to assess cell division.
Kathleen Brundage, Ph.D. Director West Virginia University Flow Cytometry & Single Cell Core Facility Enrichment of CRISPR-mediated Homologous-Directed.
بسم الله الرحمن الرحیم.
Flowcytometry.
TRENDS IN LABORATORY TESTING
Hyperdiploid Acute Lymphoblastic Leukemia With 51 to 65 Chromosomes: A Distinct Biological Entity With a Marked Propensity to Undergo Apoptosis by Chikako.
Laboratory Techniques in Immunology
Flow Cytometry and Sorting Part 1
Cell death following DNA damage occurs from cells arrested in G1 or at the G1/S boundary. Cell death following DNA damage occurs from cells arrested in.
by Anita Boyapati, Ming Yan, Luke F. Peterson, Joseph R
MK-8776, a novel Chk1 inhibitor, exhibits an improved radiosensitizing effect compared to UCN-01 by exacerbating radiation-induced aberrant mitosis  Motofumi.
Apoptotic Regulation in Primitive Hematopoietic Precursors
Flow Cytometry Journal of Investigative Dermatology
by Arun T. Kamath, Sandrine Henri, Frank Battye, David F
Optical measurement.
Hyperexpression of epidermal growth factor receptors in granulosa cells from women with polycystic ovary syndrome  Ghanim Almahbobi, Ph.D., Aileen Misajon,
Cells Isolated from the Epidermis by Hoechst Dye Exclusion, Small Size, and Negative Selection for Hematopoietic Markers Can Generate B Lymphocyte Precursors 
CD44-mediated neutrophil apoptosis in the rat
Christine V. Ichim, Džana D
Volume 15, Issue 4, Pages (October 2001)
The Art of Flow Cytometry
Volume 91, Issue 5, Pages (November 1997)
CD34+ cells from mobilized peripheral blood retain fetal bone marrow repopulating capacity within the Thy-1+ subset following cell division ex vivo  Judy.
Flow Cell Injector Tip Fluorescence signals Focused laser beam Sheath
Volume 8, Issue 1, Pages (January 1998)
AURORA-A amplification overrides the mitotic spindle assembly checkpoint, inducing resistance to Taxol  Shubha Anand, Sue Penrhyn-Lowe, Ashok R Venkitaraman 
Side Population Keratinocytes Resembling Bone Marrow Side Population Stem Cells Are Distinct From Label-Retaining Keratinocyte Stem Cells  Atsushi Terunuma,
Cécile Bouneaud, Philippe Kourilsky, Philippe Bousso  Immunity 
Opposing Effects of TGF-β and IL-15 Cytokines Control the Number of Short-Lived Effector CD8+ T Cells  Shomyseh Sanjabi, Munir M. Mosaheb, Richard A.
Intrathymic T Cell Development and Selection Proceeds Normally in the Absence of Glucocorticoid Receptor Signaling  Jared F Purton, Richard L Boyd, Timothy.
Volume 13, Issue 1, Pages (July 2000)
Volume 19, Issue 9, Pages (May 2017)
Volume 58, Issue 3, Pages (September 2000)
Volume 15, Issue 4, Pages (October 2001)
Cellular Heterogeneity in the Mouse Esophagus Implicates the Presence of a Nonquiescent Epithelial Stem Cell Population  Aaron D. DeWard, Julie Cramer,
Aplf downregulation does not induce cellular arrest.
Volume 14, Issue 1, Pages (January 2001)
Flow Cell Injector Tip Fluorescence signals Focused laser beam Sheath
Yun-Gui Yang, Tomas Lindahl, Deborah E. Barnes  Cell 
Presentation transcript:

Flow Cytometry and Sorting Part 3 Lecture Notes for “Fluorescence Spectroscopy in Biological Research” Robert F. Murphy, October 1996

Basics of Flow Sorting Droplet formation Timing Coincidence - Purity and Efficiency

Fluorescence detector Fluorescence Activated Cell Sorting 488 nm laser FALS Sensor Fluorescence detector - + Charged Plates Single cells sorted into test tubes Purdue University Cytometry Laboratories

Droplet formation As liquid is ejected into air, it will form droplets. By vibrating the nozzle at a defined frequency, the size of these droplets and the position along the stream where they form can be controlled with great precision. T. Lindmo, D.C. Peters & R.G Sweet - MLM Chapt. 8

Timing T. Lindmo, D.C. Peters & R.G Sweet - MLM Chapt. 8

Coincidence - Purity As droplets form, they can contain wanted cells as well as unwanted cells. If all droplets containing a wanted cell are sorted (regardless of whether they also contain unwanted cells), the purity of the sorted sample will be reduced.

Coincidence - Purity The purity can be improved by checking for coincidence events and not sorting any wanted cell that occurs too close to an unwanted cell. This causes an increase in purity but a reduction in sorting efficiency.

Coincidence - Efficiency The efficiency of sorting (with coincidence checking) for three-droplet sorting (solid lines) and one-droplet sorting (broken line) is shown as a function of event rate. T. Lindmo, D.C. Peters & R.G Sweet - MLM Chapt. 8

Cell Cycle Analysis One of the earliest applications of flow cytometry was the analysis of cell cycle position by quantitation of cellular DNA. Flow cytometry is still the method of choice for fast, accurate determination of cell cycle distributions.

Univariate Cell Cycle Methods In the simplest method, cellular DNA is detected using a fluorescent dye that binds preferentially to DNA. Propidium iodide is most commonly used. It undergoes a dramatic increase in fluorescence upon binding DNA. It requires permeabilization of the plasma membrane. Hoechst 33342 can be used where labeling of unpermeabilized (live) cells is desired.

Univariate Cell Cycle Methods When the amount of DNA per cell is measured on a sample from an asynchronously growing cell culture, cells with various amounts of DNA from the 2N (G0/G1) amount to the 4N (G2/M) amount are observed. A histogram reveals the fraction of cells in the various cell cycle phases.

Normal Cell Cycle s s M G2 G2 M G0 G1 G0 G1 DNA Analysis 2N 4N Count s G2 M 2N 4N 200 400 600 800 1000 DNA content Purdue University Cytometry Laboratories

DNA Analysis 2N 4N PI Fluorescence 200 400 600 800 1000 2N 4N PI Fluorescence Purdue University Cytometry Laboratories

Cell cycle progression of synchronized cells J.W. Gray, F. Dolbeare & M.G. Pallavicini - MLM Chapt. 23

DNA Analysis DNA index 1.21 Aneuploid peak PI Fluorescence 200 400 600 800 1000 PI Fluorescence Purdue University Cytometry Laboratories

Bivariate Cell Cycle Analysis To aid in the detection of cells in S-phase, a brief pulse of a marked nucleotide can be used. The most common such nucleotide is bromodeoxyuridine (BrdU) which is incorporated into DNA in place of thymidine. The incorporated BrdU can be detected with an antibody, identifying those cells that synthesized DNA during the pulse.

Detection of incorporated BrdU J.W. Gray, F. Dolbeare & M.G. Pallavicini - MLM Chapt. 23

J.W. Gray, F. Dolbeare & M.G. Pallavicini - MLM Chapt. 23

Chromosome Analysis and Sorting Individual chromosomes can be analyzed in flow after appropriate preservation and isolation. The most common method is to use two different DNA dyes, one (Hoechst 33258) that binds preferentially to AT-rich DNA and one (chromomycin A3) that binds preferentially to GC-rich DNA.

Two-color chromosome analysis J.W. Gray & L.S. Cram - MLM Chapt. 25

Normal human Normal hamster Human X hamster Normal mouse J.W. Gray & L.S. Cram - MLM Chapt. 25

Immunofluorescence Analysis A major application of flow cytometry is the analysis (and sorting) of subsets of blood cells using surface markers. A useful feature is that the major blood cell types show distinct forward and side scatter profiles.

Light Scatter Gating Side Scatter Projection Neutrophils Scale 1000 200 100 50 40 Monocytes 30 20 15 Lymphocytes 8 200 400 600 800 1000 90 Degree Scatter Purdue University Cytometry Laboratories