Advantages and Disadvantages of Statically Indeterminate Structures

Slides:



Advertisements
Similar presentations
Chapter-2 Parts of Steel Bridge.
Advertisements

CIVL3310 STRUCTURAL ANALYSIS
Characteristics of Three Bridge Types
Deflection of Indeterminate Structure Session Matakuliah: S0725 – Analisa Struktur Tahun: 2009.
Structural Bracings Presentation by V. G. Abhyankar
CIVL3310 STRUCTURAL ANALYSIS
Calculating Truss Forces
Structural Principles and Landscapes Over Structure GSD 6242 Ecologies, Techniques, Technologies IV Spring 2015Niall Kirkwood FASLA Alistair McIntosh FASLA.
Shear Force and Bending Moment
 Key Learning ◦ Various shaped objects offer different strengths.  Unit Essential Question ◦ Why is it important to know the strengths of various shaped.
ENGR-1100 Introduction to Engineering Analysis
Experimental Considerations in the Measurement of Thermal Relaxation and Recovery of Strained Seals Kurt Miller Axel Products, Inc.
4 Pure Bending.
Approximate Analysis of Statically Indeterminate Structures
Force Vectors. Equilibrium of Forces Moments from Forces (I)
10 Pure Bending.
1 THERMAL STRESSES Temperature change causes thermal strain Constraints cause thermal stresses Thermo-elastic stress-strain relationship (a) at T = T.
 Every bridge ever constructed had the same 4 stresses to overcome.  Tensile Stress- Forces that try to stretch material and pull it apart.  Compression-
CE 329 Structural Analysis
Trigonometric heighting.
Unit 2 Terms & Definitions.  Legal requirements designed to protect the public by providing guidelines for structural, electrical, plumbing, and mechanical.
5. ANALYSIS OF INDETERMINATE STRUCTURES BY FORCE METHOD
CE 329 Structural Analysis Spring Objectives ― General List Course Objectives Describe Topical Coverage for Class Provide the Formula for Computing.
Advanced Structural Analysis CE 406
ME 201 Engineering Mechanics: Statics
Structural Analysis 7 th Edition in SI Units Russell C. Hibbeler Chapter 10: Analysis of Statically Indeterminate Structures by the Force Method.
A View of NCSX Structural System and Load Path for the Base Support Structure.
Thermal Stress Objective: Lecture # 8
STIFFNESS MATRIX METHOD
Calculating Truss Forces
Types of Bridges Source:
Troop 8 Truss Presentation. What are Trusses? A truss is a type of framework, usually comprising straight struts and ties, which is designed to be stiff.
Chapter-2 Parts of Steel Bridge. contents Bearings Horizontal and transversal wind bracing Classification of bridges.
Divisional Engineer/East/Ranchi South Eastern Railway
Fundamentals of Structural Analysis, 3/e By Kenneth Leet, Chia-Ming Uang, and Anne Gilbert Lecture Outline.
TYPES OF CHASSIS FRAMES
Principles of Architecture & Construction
Shear Force and Bending Moment
ES2501: Statics/Unit 16-1: Truss Analysis: the Method of Joints
Chapter four: Structures
Analysis of Structures
Analysis of Structures
ENGR 34 Chapter 6, Day 3 3D Trusses & Frames
Calculating Truss Forces
GOALS For the classification of cracks in the wet and hardened concrete. To diagnose cracks in concrete structures and determine their types.
The Longest Bridges in the World...
Spirax Sarco Orifice Plate System
Deflection: Virtual Work Method; Trusses
Shear Force and Bending Moment
Analysis of Structures
4 Pure Bending.
Calculating Truss Forces
Kurt Miller Axel Products, Inc.
Calculating Truss Forces
Structure Analysis I Eng. Tamer Eshtawi.
Analysis of Structures
Analysis of Statically Determinate Trusses
Beams.
Structural Analysis II
Calculating Truss Forces
ANALYSIS OF STRUCTURES
Shear Force and Bending Moment
Structure Analysis II.
Structure I Course Code: ARCH 208 Dr. Aeid A. Abdulrazeg.
Structure I Course Code: ARCH 208 Dr. Aeid A. Abdulrazeg
Calculating Truss Forces
4 Pure Bending.
Why to Provide Redundant Members?
Presentation transcript:

Advantages and Disadvantages of Statically Indeterminate Structures Lesson 2 Advantages and Disadvantages of Statically Indeterminate Structures

Advantages/Disadvantages

Geometric changes cause indirect stresses

Geometric changes cause indirect stresses Statically Determinate Statically Indeterminate

Statically Indeterminate Disadvantages Geometric changes cause indirect stresses Fabrication Error If this is accidentally Fabricated too long… Statically Determinate Statically Indeterminate

Statically Indeterminate Disadvantages Geometric changes cause indirect stresses Fabrication Error If this is accidentally Fabricated too long… All joints just move to New positions Statically Determinate Statically Indeterminate

Statically Indeterminate Disadvantages Geometric changes cause indirect stresses Fabrication Error If this is accidentally Fabricated too long… Statically Determinate Statically Indeterminate

Statically Indeterminate Disadvantages Geometric changes cause indirect stresses Fabrication Error If this is accidentally Fabricated too long… Then it must be Compressed into place Statically Determinate Statically Indeterminate

Statically Indeterminate Disadvantages Geometric changes cause indirect stresses Fabrication Error Which puts these in tension If this is accidentally Fabricated too long… Then it must be Compressed into place Statically Determinate Statically Indeterminate

Statically Indeterminate Disadvantages Geometric changes cause indirect stresses Fabrication Error Which puts forces on all members If this is accidentally Fabricated too long… Then it must be Compressed into place Statically Determinate Statically Indeterminate

Statically Indeterminate Disadvantages Geometric changes cause indirect stresses Fabrication Error Which puts forces on all members No Stresses. Members go together. Members must be forced to fit. Statically Determinate Statically Indeterminate

Statically Indeterminate Disadvantages Geometric changes cause indirect stresses Statically Determinate Statically Indeterminate

Statically Indeterminate Disadvantages Geometric changes cause indirect stresses 2. Temperature Changes SUN Heated Statically Determinate Statically Indeterminate

Statically Indeterminate Disadvantages Geometric changes cause indirect stresses 2. Temperature Changes SUN Heated No Stresses. Positions just change Statically Determinate Statically Indeterminate

Statically Indeterminate Disadvantages Geometric changes cause indirect stresses 2. Temperature Changes Joints restricted by truss-action SUN SUN Heated Heated No Stresses. Positions just change Statically Determinate Statically Indeterminate

Statically Indeterminate Disadvantages Geometric changes cause indirect stresses 2. Temperature Changes SUN SUN Heated Heated No Stresses. Positions just change Thermal causes stresses Statically Determinate Statically Indeterminate

Statically Indeterminate Disadvantages Geometric changes cause indirect stresses 2. Temperature Changes SUN SUN If Expansion Joint does not Allow expansion, this duct Is statically indeterminate Heated Heated No Stresses. Positions just change Thermal causes stresses Statically Determinate Statically Indeterminate

Statically Indeterminate Disadvantages Geometric changes cause indirect stresses 2. Temperature Changes SUN SUN If Expansion Joint does not Allow expansion, this duct Is statically indeterminate Heated Heated No Stresses. Positions just change 800F high-temperature gas causes it to Crumple like a beer can Thermal causes stresses Statically Determinate Statically Indeterminate

Statically Indeterminate Disadvantages Geometric changes cause indirect stresses Simple Beam Simple Beam Pier Pier Pier Statically Determinate Statically Indeterminate

Statically Indeterminate Disadvantages Geometric changes cause indirect stresses 3. Foundation Settlement Simple Beam Simple Beam Pier Pier Pier Any Settlement: Statically Determinate Statically Indeterminate

Statically Indeterminate Disadvantages Geometric changes cause indirect stresses 3. Foundation Settlement Simple Beam Simple Beam Pier Pier Pier Any Settlement: No Curvature. No moment Statically Determinate Statically Indeterminate

Statically Indeterminate Disadvantages Geometric changes cause indirect stresses 3. Foundation Settlement Simple Beam Simple Beam Pier Pier Pier Any Settlement: No Curvature. No moment Statically Determinate Statically Indeterminate

Statically Indeterminate Disadvantages Geometric changes cause indirect stresses 3. Foundation Settlement Simple Beam Simple Beam Continuous Beam Pier Pier Pier Pier Pier Pier Any Settlement: No Curvature. No moment Statically Determinate Statically Indeterminate

Statically Indeterminate Disadvantages Geometric changes cause indirect stresses 3. Foundation Settlement Simple Beam Simple Beam Continuous Beam Pier Pier Pier Pier Pier Pier Any Settlement: No Curvature. No moment Any Settlement: Curvature! Moment! Statically Determinate Statically Indeterminate

Pier Pier Pier Pier Pier Pier Statically Determinate Statically Indeterminate

Statically Indeterminate Advantages Pier Pier Pier Pier Pier Pier M M Statically Determinate Statically Indeterminate

Statically Indeterminate Advantages Pier Pier Pier Pier Pier Pier wL2/8 M M Statically Determinate Statically Indeterminate

Statically Indeterminate Advantages 1. Lower Stresses Pier Pier Pier Pier Pier Pier wL2/8 wL2/21.4 M M M M Statically Determinate Statically Indeterminate

Statically Indeterminate Advantages 2. Greater Stiffness Pier Pier Pier Pier Pier Pier D = Statically Determinate Statically Indeterminate

Statically Indeterminate Advantages 2. Greater Stiffness Pier Pier Pier Pier Pier Pier D = 5wL4/384EI Statically Determinate Statically Indeterminate

Statically Indeterminate Advantages 2. Greater Stiffness Pier Pier Pier Pier Pier Pier D = 5wL4/384EI Statically Determinate Statically Indeterminate

Statically Indeterminate Advantages 2. Greater Stiffness Pier Pier Pier Pier Pier Pier D = 2.1wL4/384EI D = 5wL4/384EI Statically Determinate Statically Indeterminate

Statically Indeterminate Advantages 2. Greater Stiffness Pier Pier Pier Pier Pier Pier Statically Determinate DOIs = ?? Statically Indeterminate

Statically Indeterminate Advantages 2. Greater Stiffness Pier Pier Pier Pier Pier Pier Statically Determinate DOIs = 0 Statically Indeterminate DOIs = 1

Statically Indeterminate Advantages Pier Pier Pier Pier A catastrophic event eliminates the middle pier Statically Determinate DOIs = 0 Statically Indeterminate DOIs = 1

Statically Indeterminate Advantages 3. Greater Robustness – May survive redundant loss of massive overload Pier Pier Pier Pier Will NOT Survive (zero redundancy) MAY Survive (if the beam can take a Substantial increase in moment) A catastrophic event eliminates the middle pier Statically Determinate DOIs = 0 Statically Indeterminate DOIs = 1