Electrical Risks, Safety and Solutions for Older Homes

Slides:



Advertisements
Similar presentations
Electricity Merit Badge
Advertisements

Introducing Electricity and Electrical Safety
Introducing Electricity and Electrical Safety
Using Electricity in the Home
Electrical Risks, Safety and Solutions for Older Homes
Electrical Safety Program. How Electricity Works Operating an electric switch is like turning on a water faucet. Behind the faucet or switch there must.
UNIT 31 HOME ELECTRICAL SYSTEM
Electrical wiring presented by Łukasz Wiergowski and Mariusz Cyganek Electrical wiring in general refers to insulated conductors used to carry electricity,
Electrical Safety.
Electrical Safety Electrical Safety In and Around the Home NUECES COUNTY Risk Management Department.
New Mexico FFA Agricultural Mechanics Career Development Event Electric Power.
Electrical Installation
Topic 7 - Electricity in the Home
Electrical Safety Basic Electrical Safety Rafael Coll, Environment Safety and Health Section Health& Safety Group Ext Pager: (630)
Electrical Fire Safety Fire Prevention Week 2012 Electrical Safety Foundation International.
4/30/2015 AFCI 9/01/07 Rev 5 1 Arc Fault Circuit Interrupters For NEMA Field Reps.
Electrical Safety 29 CFR I. Background for the Trainer:
Inspecting Electrical. Inspection Includes:  Service entrance & masthead  Main panel and subpanels (if any)  Branch circuit wiring  Junction boxes,
The Association of Electrical and Medical Imaging Equipment Manufacturers Arc Fault Circuit Interrupter SUCCESS STORIES.
Office and Home Electrical Wiring and Safety Session 10.
EET Survey of Electronics
Electrical Power Systems
©2008 The McGraw-Hill Companies, Inc. All rights reserved. Electronics Principles & Applications Seventh Edition Arc Fault Circuit Interrupters Charles.
Circuit Protection Electrical circuits require protection to prevent fire or electrocution in the event of a fault. There are two main types of circuit.
The Home Inspection Book: A Guide for Professionals By Marcia Darvin Spada Copyright, Thomson/South-Western, 2003, Revised, 2006.
Purpose Power lines Equipment Assured Grounding GFCI Conclusion.
BUILDING TRADE SAFETY ELECTRICAL SAFETY.
Unit C7-1 Basic Principles of Agriculture/Horticulture.
ELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S
Electrical Safety.
Hazard Identification at Home. Ground Fault Circuit Interrupters (GFCI’s)  GFCI’s provide protection by turning off the power before a shock occurs 
ELECTRICAL HAZARDS Electricity is an essential of modern life Some work directly with electricity (Engineers, circuit assemblers) Some work indirectly.
Electrical Safety for Non-Electrical Workers Picture of the Week Collider-Accelerator Department Take 5 for Safety.
All Colby employees work with and around electricity on a daily basis. This Safety Talk focuses on the basic electrical safety elements to protect you.
1 HVACR116 – Trade Skills Plumbing, HVAC, Electrical Overview.
Arc Fault Circuit Interrupters. Residential fires caused by electricity occur more than 40,000 times each year in the U.S. alone. 40% are due to arcing.
Week 3. Electrical Code 1. all electrical outlets run off a pigtail from main line 2. Each Circuit is wired directly into circuit panel - no junction.
HVACR116 – Trade Skills Plumbing, HVAC, Electrical Overview.
Electrical Safety in Construction. Objectives In this course, we will discuss the following: Common electrical hazards Standards relating to those hazards.
Basic Electrical Safety
Objectives Review conductor and conduit selection Learn about protection systems (basic rules) Learn to design Residential Electrical Systems.
Fire Prevention “ Cover the Bases & Strike Out Fire”
Electrical Safety and Electrical Safe Work Practices EHS Course #525 Reference EHS Electrical Safety Procedure
Electrical Principles and Wiring Materials Original Power Point Created by Casey Osksa Modified by Georgia Agricultural Education Curriculum Office June.
Electrical Safety in the Home 1.Circuit Breakers 2.Fuses 3.Wall Outlets 4.Circuit Breakers 5.GFCI/RCD.
ELECTRICAL FIRES CAN BE PREVENTED! By PowerCheck.
STAY SAFE!. ELECTRICAL FIRES ARE ALL TOO FREQUENT! -Homes over 40 years of age are at increased risk of fire. -The fire hazards are usually not recognized.
By: Mr. Brock.  Electricity- Source of energy that can be easily converted into light, heat or power  Ampere (Amp)- Unit of measure of the rate of flow.
Electrical Safety, Subpart K
ELECTRICAL WIRING WIRING BASICS Written by Bobby Joslin
Electrical Repair and Maintenance
Joel Moody, MD, PhD, MPH Director of Safety, Risk, Policy and Innovation Why did the requirements for Arc Fault Circuit Interrupters in Dwellings Change?
Electrical Safety Basic Electrical Safety. Electrical Safety  Course not designed to teach you to work on electrical equipment. Basic Electrical Safety.
Introducing Electricity and Electrical Safety
Making Circuits Safe SNC1P1 Findlay.
Circuit Protection Unit 9.
Basic Electrical Safety
"Don't Get Amped Up! Electrical Safety to Keep Your Team Grounded!"
Effects of Electrical Current on the Body
HOME ELECTRICAL SAFETY
AFCI Protection: AFCI Receptacles and the NEC
Electrical Safety Review Compliance Assistance Region IV
Outlet Branch Circuit Arc Fault Circuit Interrupter (OBC AFCI)
Domestic Electricity AIM: To understand the use of domestic electricity and safety features such as fuses, circuit breakers and the earth circuit
Basic Electrical Safety
Click anywhere to get started…
Basic Electrical Safety
Objectives Learn about Electricity Pricing Electric systems.
Objectives Review conductor and conduit selection
Presentation transcript:

Electrical Risks, Safety and Solutions for Older Homes Presented by: Brian Cook PowerCheck Electrical Safety Services www.powercheck.ca

© PowerCheck Electrical Safety Services 2012 Learning objectives To understand the different types of wiring used in older houses To recognize the leading electrical fire concerns in older houses To understand the PowerCheck program © PowerCheck Electrical Safety Services 2012

© PowerCheck Electrical Safety Services 2012 Electrical fires In BC, 2004-2007 633 reported electrical fires 4 fatalities $55.7 MM property loss Represents ~10% of reported fires © PowerCheck Electrical Safety Services 2012

As houses ages: Probability of fire increases In 25% date of house construction unknown. Data source: BC OFC © PowerCheck Electrical Safety Services 2012

What is causing electrical fires? Old services, panels & wiring Important to check, and sometimes faulty, though not the leading cause of electrical fire Handyman tinkering Accounts for the vast majority of electrical fires. Hazardous add-ons build up over the years. Sometimes old houses are rampant with hazardous handyman add-ons ALL TOO COMMON. In older homes hazards such as this add-on basement receptacle are commonly found. These hazardous additions put the house at high risk of electrical fire. © PowerCheck Electrical Safety Services 2012

Electrical System Components Three components to your electrical system: Service & Panelboard Wiring Electrical devices (switches, receptacles, lights) Service & Panelboard Wiring Electrical devices © PowerCheck Electrical Safety Services 2012

© PowerCheck Electrical Safety Services 2012 Service: 60-amp Until the1970s nearly all homes had 60-amp service. Original 60-amp services can be acceptable today, if there has been no additional circuits or tampering. Homeowners today are often not aware their home has 60- amp service. “Rated for 100 amps” 60-amp fuses, 60-amp service Old service boxes often have the wording “Rated for 100 amps”. This refers to the box rating, not service size. © PowerCheck Electrical Safety Services 2012 7

Sometimes panelboards have been hazardously upgraded 60 amp 200 amp 200 amp main breaker on 60 amp service! 100 amp main breaker on 60 amp service! © PowerCheck Electrical Safety Services 2012

Common hazard in panelboard: An over-rated circuit breaker… 15-amp circuit breaker 30-amp circuit breaker © PowerCheck Electrical Safety Services 2012 9

…can create over-heated conductors © PowerCheck Electrical Safety Services 2012 10

Wiring before 1950: Knob and tube Installed in nearly all homes built before 1950. Still present in most pre-1950 homes today. Often concealed thus hard to identify, particularly if outlets have been changed. Original two-prong, ungrounded receptacle © PowerCheck Electrical Safety Services 2012

Knob and tube: Qualities Characteristics: Two single conductors Supported by porcelain knobs and tubes A well designed system: Heavy gauge conductors Spaced well apart All connections soldered Work seldom done by non- professionals knobs tubes If basement has been finished, and new panel installed, knob and tube is likely concealed, behind the walls and in the ceilings © PowerCheck Electrical Safety Services 2012

© PowerCheck Electrical Safety Services 2012 Knob and tube: Hazards Original 2-prong outlets: Now 3- prong: Result: No ground protection Original lighting: Now recessed lighting Result: Insulation breakdown The limited number of outlets in older homes spurred add-on circuits, so often installed by unqualified people. Result: Hazardous add-on circuits In 99% of older homes, the original 2-prong outlets have been found swapped for modern 3-prong, falsely presenting receptacles are grounded. © PowerCheck Electrical Safety Services 2012

Knob and tube: Solutions Rewire: $20,000 + or If wiring checks out fine: GFCIs can provide excellent ground protection: $20 each Note: Vast majority of homes: Old wiring = Excellent condition! AN EXCELLENT SOLUTION! GFCI receptacle provides excellent ground protection. It disconnects the power if leakage to ground exceeds 5 mA. © PowerCheck Electrical Safety Services 2012

Knob and tube: Findings In 99% of homes: Knob and tube wiring is still live today Usually not visible due to new panel and finished basement. Knob-and-tube wiring is in excellent condition No need for expensive replacement, but: Original 2-prong outlets now modern 3-prong Falsely presenting outlets are grounded, thus rated “High Risk”. Cost to eliminate fire risk: Less than $500 RESULT: SAFE AND HAPPY HOMEOWNERS! © PowerCheck Electrical Safety Services 2012

1950s: Ungrounded cable “NMD1” New cable introduced 1950. Installed in most homes throughout the ‘50s Similar to knob and tube, presenting same fire concerns: Original 2-prong outlets now 3-prong Not suitable for recessed lighting Due to limited number of outlets installed at time of construction: Probability of hazardous add-ons in home is high. Due to speed of installation NMD1 quickly replaced knob-and-tube wiring. Shown here, feeding a 3-prong receptacle © PowerCheck Electrical Safety Services 2012

© PowerCheck Electrical Safety Services 2012 Wiring of the 1960s NEW cable introduced in the 1960s: “With ground” Fire hazards: Though providing ground protection, the insulation is still not suitable for recessed lighting. Due to limited number of outlets installed at time of construction, probability of hazardous add-ons being present in home is high. Introduced in the late 1950s: “NMD3”. Same conductors as NMD1, but “With ground”. Early versions had these words written on the cable jacket. © PowerCheck Electrical Safety Services 2012

© PowerCheck Electrical Safety Services 2012 Wiring of the 1970s A new cable with higher insulation temperature becomes the standard. Suitable for recessed lighting. Fire hazards: Due to the rapid rise in basement suites, kitchen renos and powering of garages: Unauthorized electrical work thrives. This is encouraged with the proliferation of self-help guide books and easy access of electrical supplies. Modern wiring, NMD7 & NMD90 become the standard, but along with it comes “do-it-yourselfers”. © PowerCheck Electrical Safety Services 2012

© PowerCheck Electrical Safety Services 2012 Aluminum wiring: 1966 – 1974 In vast majority of homes built 1966 – 1974. Still present today in most homes built 1966 – 1974. Designed as a cost- effective solution due to the high price of copper during these years. An aluminum-rated receptacle was required with the installation of aluminum wire. © PowerCheck Electrical Safety Services 2012

Aluminum wiring: Hazards Aluminum wiring can be fine, but: Original aluminum-rated outlets are commonly found swapped for modern, non-aluminum-rated outlets HAZARD: LOOSE & POSSIBLY CORRODED CONNECTIONS FIRE HAZARD! Original aluminum-rated outlets are commonly found swapped for modern, non-aluminum-rated outlets. © PowerCheck Electrical Safety Services 2012

Aluminum wiring: Solutions Rewire: $20,000 or Approved copper pigtailing/ aluminum rated devices Typical cost: ~$1000 Plus: Regular maintenance Checking that electrical connections have remained sound, recommended every 15 years. “If home [with aluminum wiring] has not been checked since new, it is high time overdue” (NFPA). © PowerCheck Electrical Safety Services 2012

© PowerCheck Electrical Safety Services 2012 Hazardous add-ons So prevalent in older houses, putting house at risk of fire Multitude of ways, including: Incorrect cables Circuits poorly grounded Oversized circuit breakers Poor electrical connections Knock outs (“mouse holes”) in JBs and panels BX cables without antishorts © PowerCheck Electrical Safety Services 2012

Some hazards are inadvertent actions from other trades Original copper water pipe replaced with “PEX” plumbing pipe, disconnecting the service ground Old hot-water-tank electrical cable left live and dangling. Both these concerns commonly found © PowerCheck Electrical Safety Services 2012

Houses with illegal suites show particularly increased risk To accommodate additional power demands of multiple suites, original 60-amp fuses are sometimes found replaced with copper pipe, eliminating circuit protection, putting house in extreme peril. This exact scene was found by PowerCheck in an older home in Vancouver. Homeowner believed he had 100-amp service due to rating on box. Home was sent to us because of knob-and-tube wiring. © PowerCheck Electrical Safety Services 2012

Old circuit breakers may not trip Old breakers, such as Pushmatic, XO Sq. D & Federal Pacific do not have the fast trip characteristics of modern breakers Old circuit breakers, pre-1970s have well exceeded their rated service life. Type XO breakers, by Square D should be replaced whenever identified. © PowerCheck Electrical Safety Services 2012

Exposed electrical connections If connections become at all loose they will arc, easily igniting surrounding wall material. Commonly found. Exposed connections This scene was found in a older home in New Westminster by PowerCheck. Home was sent to us because of knob-and-tube wiring. © PowerCheck Electrical Safety Services 2012

No junction box behind electrical device If connections become at all loose they will arc, easily igniting surrounding ceiling material. Commonly found. Home was sent to us because of knob-and-tube wiring. © PowerCheck Electrical Safety Services 2012

Extension cords stapled to walls Staples put pressure on cord. Over time the cord insulation breaks down. The staple then creates a direct short across the wires, which can easily result in fire. Commonly found. staples Home was sent to us because of knob-and-tube wiring. © PowerCheck Electrical Safety Services 2012

Baseboard heaters prone to fires Electrical equipment needs to be installed with thorough knowledge of the electrical code. Incorrect installation can easily result in electrical fires. http://blog.cleveland.com/metro/2007/12/third_child_killed_by_shaker_h.html “Seven firefighters said the fire began about 1 a.m. near an electric baseboard heater. Three children died, ages 6, 2 and 14 months” (Cleveland News, Dec 5, 2007). © PowerCheck Electrical Safety Services 2012

Statistics Pre-1950 homes in general Handyman tinkering Old age Electrical wire Data source: First 100 homes examined by PowerCheck © PowerCheck Electrical Safety Services 2012

Statistics Pre-1950 homes with secondary suite Handyman tinkering Electrical wire Data source: First 100 homes examined by PowerCheck © PowerCheck Electrical Safety Services 2012

© PowerCheck Electrical Safety Services 2012 Risk and age Statistically old homes are more dangerous This is primarily due to the compounding effect of handyman tinkering, building-up over the years This is particularly noticeable in homes with secondary suites If we were to examine all houses pre-25 years we would identify the vast majority of dangerous homes Notes on data Values based on preliminary data from 150 homes examined to date With larger sample, values may vary from above, however clearly there is a trend © PowerCheck Electrical Safety Services 2012

© PowerCheck Electrical Safety Services 2012 Summary Electrical fire hazards are to be found in nearly all homes built before 1975. Though deterioration of older electrical systems is occasionally found, the vast majority of fire hazards have been due to handyman tinkering. Expected cost to bring home to “Medium Risk”, in vast majority of homes: < $1000 Expected cost to bring home from “Medium Risk” to “Low Risk”: $1000 - $1500 © PowerCheck Electrical Safety Services 2012

PowerCheck Electrical Safety Assessment Standardized electrical safety examinations Key points: Conducted only by master electrician Comprehensive 80-point examination Third party examination only © PowerCheck Electrical Safety Services 2012

PowerCheck Electrical Safety Report Standardized risk rating Extreme High Medium Low One price: $349 for all single family homes* * 2012, up to 300m2, within major city limits © PowerCheck Electrical Safety Services 2012

PowerCheck Risk Rating explained Extreme Risk Serious fire hazards identified requiring immediate attention High Risk Fire hazards identified. Repairs recommended ASAP Medium Risk Acceptable condition. Complies with code at time of installation. Low Risk Not only meets Medium Risk, but additional upgrades have been done to substantially bring home up to current standards. © PowerCheck Electrical Safety Services 2012

The PowerCheck promise Standardized examinations Accurate and consistent reports Examiners across Canada Simplifying the electrical risk evaluation process Over 2000 clients have had their electrical system examined by PowerCheck. Nearly all have said, “It was the best thing that we have ever done”. © PowerCheck Electrical Safety Services 2012