Avalanche flutuations with InGrid/TimePix

Slides:



Advertisements
Similar presentations
Study of avalanche fluctuations and energy resolution with an InGrid- TimePix detector D. ATTIÉ 1), M. CAMPBELL 2 ), M. CHEFDEVILLE 3), P. COLAS 1), E.
Advertisements

Micro MEsh GASeous Detectors (MicroMegas)
M. Chefdeville NIKHEF, Amsterdam MPGD, Hawaii 07
Maximilien Chefdeville NIKHEF, Amsterdam RD51, Amsterdam 17/04/2008
Beijing, August 18, 2004 P. Colas - Micromegas for HEP 1 Recent developments of Micromegas detectors for High Energy Physics Principle of operationPrinciple.
Amsterdam, April 2,2003P. Colas - Micromegas TPC1 Micromegas TPC: New Results and Prospects New tests in magnetic fieldNew tests in magnetic field FeedbackFeedback.
Simulation of the spark rate in a Micromegas detector with Geant4 Sébastien Procureur CEA-Saclay.
3-D simulation of Si-Prot Charge distribution, signal development D. Attié, P. Colas, E. Delagnes, S. Turnbull - Introduction - Orders of magnitude - Simulation.
GEM Detector Shoji Uno KEK. 2 Wire Chamber Detector for charged tracks Popular detector in the particle physics, like a Belle-CDC Simple structure using.
1 Pixel Readout of GEMs Motivation The Setup Results Next Steps A. Bamberger, K. Desch, J. Ludwig, M. Titov, U. Renz, N. Vlasov, P. Wienemann, A. Zwerger.
Gas pixel detector for x-ray observation
Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA.
Kolympari, Crete, June 16, Study of avalanche fluctuations and energy resolution with an InGrid-TimePix detector P. Colas Progress report, based.
Measurement of gas gain fluctuations M. Chefdeville, LAPP, Annecy TPC Jamboree, Orsay, 12/05/2009.
Simulation of the spark rate in a Micromegas detector with Geant4 Sébastien Procureur CEA-Saclay.
ECFA Meeting, Valencia – November 8, First TimePix tests at CERN David Attié ECFA Meeting – Valencia – 8 November 2006.
Gain fluctuations and Neff Analysis of March 2010 data Neff measurement Gain fluctuation measurements with TimePix Beijing, 30/03/20101 P. Colas - FJPPL-FCPPL-LCTPC.
GridPix studies at Saclay Avalanche fluctuations D. Attié, A. Chaus, P. Colas, M. Titov GridPix workshop, Feb. 22, 2012.
LRT2004 Sudbury, December 2004Igor G. Irastorza, CEA Saclay NOSTOS: a spherical TPC to detect low energy neutrinos Igor G. Irastorza CEA/Saclay NOSTOS.
GOSSIP : Gas On Slimmed SIlicon Pixels NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay.
A. Chaus, D. Attie, P. Colas, M. Titov CEA Saclay, Irfu/SPP, France Ingrid OUTLINE: OUTLINE:  “Octopuce” Uniformity Studies in the Laboratory  DESY Test-Beam.
Annual Meeting 2008 – October 6 th 1 David Attié P. Colas, X. Coppolani, E. Delagnes, A. Giganon, I. Giomataris Status of Saclay.
Stanford, Mar 21, 2005P. Colas - Micromegas TPC1 Results from a Micromegas TPC Cosmic Ray Test Berkeley-Orsay-Saclay Progress Report Reminder: the Berkeley-Orsay-
21 April 2004LCWS 2004 Paris1 Readout of a TPC using the Medipix2 CMOS pixel sensor (detection of single electrons on a direct pixel segmented anode) NIKHEF:
The detection of single electrons using the MediPix2/Micromegas assembly as direct pixel segmented anode NIKHEF: A. Fornaini, H. van der Graaf, P. Kluit,
Beijing, Feb.6, 2007 P. Colas - Micromegas TPC 1 Micromegas TPC studies in a 5 Tesla magnetic field with a resistive readout D. Attié, A. Bellerive, K.
Micromegas TPC Beam Test Result H.Kuroiwa (Hiroshima Univ.) Collaboration with Saclay, Orsay, Carlton, MPI, DESY, MSU, KEK, Tsukuba U, TUAT, Kogakuin U,
Timepix at NIKHEFMedipix meeting, CERN – Some recents results at NIKHEF M. Chefdeville, E. Bilevych, H. van de Graaf, J. Timmermans D. Attié,
Experimental and Numerical studies on Bulk Micromegas SINP group in RD51 Applied Nuclear Physics Division Saha Institute of Nuclear Physics Kolkata, West.
Digital primary electron counting: W, Fano Factor, Polya vs Exponential M. Chefdeville, NIKHEF, Amsterdam RD51, Paris, October 2008.
Preliminary results of a detailed study on the discharge probability for a triple-GEM detector at PSI G. Bencivenni, A. Cardini, P. de Simone, F. Murtas.
Piggyback seal Micromegas D. Attié, A. Chaus, D. Durand, D. Deforges, E. Ferrer Ribas, J. Galán, I.Giomataris, A. Gongadze, F.J. Iguaz, F. Jeanneau, R.
1 Readout of a TPC by Means of the MediPix CMOS Pixel Sensor NIKHEFAuke-Pieter Colijn Arno Aarts Alessandro Fornaini Maximilien Chefdeville Harry van der.
1 Update on Silicon Pixel Readout for a TPC at NIKHEF LCWS08 - Chicago 19 Nov 2008 Jan Timmermans NIKHEF.
Snowmass, August, 2005P. Colas - InGrid1 M. Chefdeville a, P. Colas b, Y. Giomataris b, H. van der Graaf a, E.H.M.Heijne c, S.van der Putten a, C. Salm.
1 Status ‘Si readout’ TPC at NIKHEF NIKHEFMaximilien Chefdeville Auke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans.
1 The pixel readout of TPCs Max Chefdeville, NIKHEF, Amsterdam.
A. SarratTPC jamboree, Aachen, 14/03/07 1 Full Monte Carlo of a TPC equipped with Micromegas Antony Sarrat CEA Saclay, Dapnia Motivation Simulation content.
January 10, 2008MiPGD TPC resolution and gas1 Micromegas TPC addendum on measurements P. Colas, Saclay Lectures at the TPC school, Tsinghua University,
Micromegas (Ingrid)+TimePix 8-chip modules
Goddard February 2003 R.Bellazzini - INFN Pisa A new X-Ray Polarimeter based on the photoelectric effect for Black Holes and Neutron Stars Astrophysics.
EUDET Meeting, Munich – October 18, Ongoing activities at Saclay David Attié D. Burke; P. Colas; E. Delagnes; A. Giganon; Y. Giomataris;
November 8, 2006ECFA ILC Workshop1 Recent developments for digital TPC readout Jan Timmermans - NIKHEF Micro Pattern Gas Detector: GridPix Integration.
LCWS Bangalore, March 13, 2006 P. Colas, Digital TPC R&D1 R&D for a digital TPC The SiTPC project The digital TPC concept and advantages VLSI electronics:
IEEE/NSS Oct 22, Electron Counting and Energy Resolution Study from X-ray conversion in Argon Mixtures with an InGrid-TimePix detector. D. ATTIÉ.
Status report NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA DAPNIAMaximilien.
T. Zerguerras- RD51 WG Meeting- CERN - February Single-electron response and energy resolution of a Micromegas detector T. Zerguerras *, B.
Endplate meeting – September 13, Gas issues for a Micromegas TPC for the Future Linear Collider David Attié D. Burke; P. Colas;
The digital TPC: the ultimate resolution P. Colas GridPix: integrated Timepix chips with a Micromegas mesh.
R&D Collaboration, CERN – September 10, Micromegas Performance and Ageing studies David Attié MPGD. Towards an R&D Collaboration,
On behalf of the LCTPC collaboration -Uwe Renz- University of Freiburg Albert-Ludwigs- University Freiburg Physics Department.
Vienna Conference on Instrumentation – February 27, D. Attié, A. Bellerive, K. Boudjemline, P. Colas, M. Dixit, A. Giganon,
Gossip : Gaseous Pixels Els Koffeman (Nikhef/UvA) (Harry van der Graaf, Jan Timmermans, Jan Visschers, Maximilien Chefdeville, Vladimir Gromov, Ruud Kluit,
Werner Riegler, Christian Lippmann CERN Introduction
TPC for ILC and application to Fast Neutron Imaging L. An 2, D. Attié 1, Y. Chen 2, P. Colas 1, M. Riallot 1, H. Shen 2, W. Wang 1,2, X. Wang 2, C. Zhang.
CALICE, Shinshu, March Update on Micromegas TB analysis Linear Collider group, LAPP, Annecy CALICE collaboration meeting 5-7 March 2012, Shinshu,
Max Chefdeville, NIKHEF, Amsterdam
High Energy Physics experiments.
Larger Pixels, New Insights
MPGD 2013 Conference,Zaragoza July 1-4, 2012
Recents Analysis Results From Micromegas TPC
TPC Paul Colas Technical meeting, Lyon.
R&D for a digital TPC The SiTPC project
Ionization detectors ∆
MINOS: a new vertex tracker for in-flight γ-ray spectroscopy
TPC chamber for Medipix2/TimePix
réponse d’un détecteur Micromegas
Gas Pixel TRD/Tracker With the support of the TRT collaboration
Werner Riegler, Christian Lippmann CERN Introduction
Gain measurements of Chromium GEM foils
Presentation transcript:

Avalanche flutuations with InGrid/TimePix RD51 Mini-week, 22-25 February 2010 Recent measurements of gain fluctuations with an InGrid-TimePix detector D. ATTIÉ1), M. CAMPBELL2 ), M. CHEFDEVILLE3) , P. COLAS1), E. DELAGNES1) , K. FUJII4) , I.GIOMATARIS1) , H. VAN DER GRAAF5) , X. LLOPART2) , M. LUPBERGER1) , H. SCHINDLER2) ,J. SCHMITZ6), M. TITOV1) 1) CEA/Irfu Saclay, 2) CERN, 3)LAPP Annecy, 4)KEK, 5)Nikhef, 6)Twente U. Avalanche fluctuations are an old problem, motivated by recent applications in MPGDs, which can be addressed with new tools. 23/02/2010, CERN Avalanche flutuations with InGrid/TimePix

Avalanche flutuations with InGrid/TimePix Avalanche statistics K. Fujii Polya : not the exact solution, but provides a simple parametrization of the avalanche size G. Z = G / <G> q = 0 : exponential distribution 23/02/2010, CERN Avalanche flutuations with InGrid/TimePix

New tool : TimePix chip + InGrid CERN-Nikhef-Saclay Collaboration within EUDET Pixel Idea : take a medical imaging chip (Medipix 2), add a clock to each pixel, replace ‘grey levels’ by ‘clock ticks’ (Michael Campbell, Xavi Lloppart, CERN) 65000 pixels, 14-bit counter, 100 MHz tunable clock frequency -> more voxels than the ALEPH TPC, but tiny! Cover the chip with a deposited grid over SU8 pillars 50 µ high to obtain gas amplification The chip is protected by 7 µ SiN to avoid destruction by sparks. 1 2 3 4 5 55 μ m 14111 m 16120 m 14080 m (pixel array) 55 mm Synchronization Logic Interface Preamp/shaper Configuration latches Counter THL disc. 23/02/2010, CERN Avalanche flutuations with InGrid/TimePix

Avalanche flutuations with InGrid/TimePix Micromegas + TimePix Fe 55 source DRIFT TimePix Chamber operated with an Ar+5% isobutane mixture DRIFT SPACE ED ~ 0.7 kV/cm 2.5 cm 50 µm EA ~ 80 kV/cm MICROMESH READOUT InGrid (Nikhef-Twente) 23/02/2010, CERN Avalanche flutuations with InGrid/TimePix

Avalanche flutuations with InGrid/TimePix 1) Measure Time Over Threshold (linear with charge above 5 ke-) for single isolated pixels : direct access to avalanche charge distribution. 2) See electrons from an X-ray conversion one by one (55Fe) and count them. Efficiency vs gain sensitive to q parameter threshold 3) (not repeated here, see RD51 in Crete) Measure fluctuations of primary ionization and derive gain fluctuations from energy resolution. 23/02/2010, CERN Avalanche flutuations with InGrid/TimePix

Gain fluctuations from Time Over Threshold Select isolated clusters with only 1 pixel. These are single electron avalanches (~10 µ rms radius). TOT is linear with number of electrons seen by the amplifier above 5 ke- : Ne = 167 TOT – 6700 (red curve, corresponding to the threshold setting of our data taking) Valid up to 30 000 electrons. This gives a direct access to avalanche size. Number of electrons 10000 20000 30000 TOT (in 28 ns time bins) U in (Volts) 23/02/2010, CERN Avalanche flutuations with InGrid/TimePix

Distributions of avalanche size from TOT at different gains Z = G/<G> = (167*TOT-6700)/G(V) G(V) from a measurement using a source. Z=G/<G> Gain =6000 Gain =12600 Z=G/<G> Z=G/<G> 23/02/2010, CERN Avalanche flutuations with InGrid/TimePix

Same Z from TOT distributions but log scale to see the tails Gain =2900 Unfortunately, the tails are dominated by TOT resolution effects. Z=G/<G> Gain =6000 Gain =12600 Z=G/<G> Z=G/<G> 23/02/2010, CERN Avalanche flutuations with InGrid/TimePix

Avalanche size distribution from TOT Polya fits above Zmin = 5000/<G> (region of linearity of TOT) are good However theta values are not reliable (very correlated with the gain measurement and the TOT scale. There is a discrepancy between the average number of electrons and the gain: this is a possible effect from the protection layer and from the shaping by electronics. HV mesh Gain fitted q 310 V 2900 5.3±1.3 330 V 6000 3.8±0.1 350 V 12600 4.7 We do not regard these fitted values as measurements of theta. They point to a value of 4.3 but with very large systematic errors (factor of 2?) 23/02/2010, CERN Avalanche flutuations with InGrid/TimePix

Avalanche flutuations with InGrid/TimePix ELECTRON COUNTING Monte Carlo simulation Gas : Ar+5% isobutane 23/02/2010, CERN Avalanche flutuations with InGrid/TimePix

Avalanche flutuations with InGrid/TimePix In our setup, we use the Chromium K-edge to cut the Kb line (Center for X-Ray Optics) 23/02/2010, CERN Avalanche flutuations with InGrid/TimePix

Avalanche flutuations with InGrid/TimePix Monte Carlo simulation. Shows that we need enough drift distance to separate the clusters. Also shows that the escape peak is better contained than the photopeak. 23/02/2010, CERN Avalanche flutuations with InGrid/TimePix

Avalanche flutuations with InGrid/TimePix Drift distance (z) cut performed using the diffusion : sqrt(rmsx 2 + rmsy 2 ) > 28 pixels (cluster separation) Cloud center within a window around the chip center (containment) Gas : Ar+5% isobutane Data Ugrid = 350 V NUMBER OF CLUSTERS 23/02/2010, CERN Avalanche flutuations with InGrid/TimePix

Avalanche flutuations with InGrid/TimePix Use escape peak (only one line, better contained) Then correct for collection efficiency (96.5 +- 1 % from MC, in this range of field ratios : 80-90) Convert U_grid into gain/threshold (threshold = 1150 e-) 23/02/2010, CERN Avalanche flutuations with InGrid/TimePix

Avalanche flutuations with InGrid/TimePix Collection efficiency from simulation : 96.5±1 % Gain measurements (from a 80x80 mm2 copper mesh with the same gap 50 µm, gas : Ar+5% isobutane 1µ thickness 2µ thickness Prediction from R. Veenhof et al., Data (in red) from D. Attié et al. (see also D. Arrogancia et al. 2009) 23/02/2010, CERN Avalanche flutuations with InGrid/TimePix

Avalanche flutuations with InGrid/TimePix ~1 at moderate gain (few 1000). Maybe higher at gains above 5000 Exponential behaviour (q=0) strongly excluded, as well as q>2 23/02/2010, CERN Avalanche flutuations with InGrid/TimePix

Determination of W and F The background is totally negligible (time cut taking 30 time buckets around the electron cloud among 11000) The probability for merging two clusters is small, with the rms cuts. The probability for loosing electrons by the containment cuts is small. Attachment also is negligible. The main inefficiency comes from collection : 96.5+-1 % from simulation. Using the escape peak: W= 2897 eV / 120.4 = 24.06 +- 0.25 eV This translates to 245+-3 electrons for the 5.9 keV line, larger than what is usually admitted for pure Ar (227). Photoelectric effect on the mesh is not excluded. This could also be a Penning effect in the conversion region. The Fano factor could be derived from the rms of the escape line (6.8 e- ) but needs large corrections from inefficiencies. Gas : Ar+5% isobutane 23/02/2010, CERN Avalanche flutuations with InGrid/TimePix

Avalanche flutuations with InGrid/TimePix CONCLUSIONS InGrid, Microbulk, and TimePix are new detectors which allow to study the conversion and avalanche processes with unprecedented accuracy. Time Over Threshold measurements give access to direct measurement of the fluctuations, provided absolute gain and TOT calibration can be better controlled. The onset of single electron efficiency with Micromegas gain allows the exponential fluctuations to be excluded and favours Polya fluctuations with q close to 1 at moderate gain and reaching a few units at gains of 10 000. To measure Fano fluctuations will require an improved setup with a longer drift and better controled field. Special thanks to R. Veenhof, J. Timmermans and Y. Bilevych 23/02/2010, CERN Avalanche flutuations with InGrid/TimePix