Treatment – Chlorine Disinfection

Slides:



Advertisements
Similar presentations
Appropriate Technologies Conference Simple chemical dosing systems in small water works Cape Peninsula University of Technology G. Mwiinga Cape.
Advertisements

Potential Pathways for Coliform Contamination. Fixing Positive Coliform Results.
Blood Glucose Monitoring And Bloodborne Pathogens
 Violations of the following regulations WILL result in a loss of lab points.
Nathan Saunders, P.E. Maine Drinking Water Program Public Water System Owner & Operator Responsibility.
HOW DISINFECTION WORKS. Disinfection kills or inactivates living organisms that cause disease Oxidation destroys the physical structure of the organism.
Flocculation and chlorination process control Jar test and Chlorine demand test.
Work In Confined Spaces
BRC Storage & Distribution Safety and Quality Management System Training Guide
Hazard Analysis Ensuring Safe food. Hazard Analysis.
Good hygienic practices
Requirements to produce high quality water Stephen Stanley, Ph.D., P.Eng. EPCOR Water Services.
Good Hygiene Practices Incoming Material Requirements Section 2 - Sub-Module 5.2.
Huzairy Hassan School of Bioprocess Engineering UniMAP.
Case Study 3.1: WP Inc. Problem-Solving
BRC Food Safety Quality Management System Training Guide
Respirator Safety This Training Covers Respirator Inspection User Fit Checks Respirator Cleaning Respirator Storage.
Introduction to Equipment
A Basic Overview of the US FDA’s Regulations for Regulatory Compliance
CTC 450 Review Water processing.
ISO OPERATIONAL CONTROL
6-1. Key Sanitation Condition No. 6: Proper labeling, storage and use of Potential toxic compounds.
Support Programs version 2 March 2010 Cleaning and Sanitation
WASH cholera / AWD EP&R training Key responses – Water Water treatment and Priorities in Different Settings Session 3.2 WASH Cholera / AWD EP&R training.
What effects do they have in drinking water
Environmental Engineering Lecture 7 Dr. Hasan Hamouda.
Important informations
Issues Arising from The Quality of Drinking Water In Ireland Report Brendan Wall Senior Inspector Environmental Protection Agency.
Proposed Rule for Preventive Controls for Animal Food.
Proposed Rule: 21 CFR 507 Proposed Rule for Preventive Controls for Animal Food 1.
NSF 60 Revisions Purkiss December 4, Update on Chlorate SPAC established in NSF 60 – 2012 = 200 ppb. SPAC calculation did not utilize all sig figs.
Water Analysis & Control. Water analysis & control WATSAN M15 ERU 2 Contents 1.Chemical parameters and ranges 2.Water sources: Sampling procedures 3.Laboratory.
ACWA – RECYCLE RESEARCH Presentation to the ACWA National Convention August 2009.
Nitrification Action Plans
WASH Cluster – Emergency Training GWD GWD5 1 1 Groundwater Development and Drilling Session 5 Protecting Groundwater Sources.
Leading ClO2 Technology
How and When to Clean and Sanitize ______________________ Process of removing food and other dirt from a surface All surfaces must be cleaned and rinsed.
Awareness Training: ‘HARPC’ for Food Safety Complimentary Presentation by Quality Systems Enhancement 1790 Wood Stock Road Roswell GA E. mail:
Water Treatment: Disinfection Processes Current Technology vs. Alternatives.
Drinking water 2010 July 2011 Private Water Supplies – What it all means to me? Phil Smart Laura Moss Drinking Water Inspectorate.
© Food – a fact of life 2009 Hazard Analysis Critical Control Point (HACCP) HACCP is a system which looks for and prevents potential problems before they.
Author: Nurul Azyyati Sabri
Radiography Dentalelle Tutoring.
CTC 450 Review Water processing.
Hazard Analysis Critical Control Point (HACCP).
Lecture (9): Monitoring & sampling methods, maintenance ,
ACWA – RECYCLE RESEARCH
WASTEWATER CHLORINATION DECHLORINATION MONITORING AND CONTROL PILOT DEMONSTRATION AT CLARKSON AND CITY OF GUELPH ONTARIO WWTPs Wei Zhang1, Jeremy Leverence1,
Hazard Analysis Critical Control Point (HACCP)
Water Treatment Hypochlorite as a disinfectant for drinking water
Risk Assessment should include:
SAFE WORK INSTRUCTIONS
Requirements to produce high quality water
Matt Bower DWQR Risk Assessment Training 2018
Treatment – Cartridge Filters
Treatment – Ion Exchange Filters
Lesson 8 Good Production Practice #8
Matt Bower DWQR Risk Assessment Training 2018
Treatment – Sediment Filters
Treatment – Process Resilience
Treatment – Ultraviolet (UV)
Treatment – Plant Design
Treatment –Reverse Osmosis (Desalination)
Treatment – pH Correction / Conditioning
Treatment – Chlorine Dioxide
Treatment – Slow Sand Filters
Treatment – Chemical Filters
Food Safety T-1150 This work has been produced by DGL (Aust) Pty Ltd
Hazard Analysis Critical Control Point (HACCP)
Risk Management Student Powerpoint
Presentation transcript:

Treatment – Chlorine Disinfection DWQR Risk Assessment Training 2018

Overview Traditional, established disinfectant Relatively cheap Usually dosed as liquid (sodium hypochlorite) Active disinfectant is hypochlorous acid (favoured form at low pH (<8)) Effective against bacteria, not Cryptosporidium Leaves a lasting residual in water Taste and by-products (THMs) can be an issue

Usage Chlorine needs time to react (contact tank or pipe – typical time 30 mins) Typical residual; (after reaction) 0.2-0.5 mg/l Chlorine demand will vary with water quality (ideally automatically controlled) Dosing can be fixed, flow proportional or residual controlled (latter is best) Chlorine far less effective >pH8 (pH correct after disinfection) Chlorine residual may drop off in high residence time / low flow scenarios or where dirty pipes Possible to top up Cl in long systems (but consider by-products)

Usage Hypochlorite solution typically 14% by mass, but goes off with time (stock control) Health and safety considerations of handling Monitor at addition, after contact time and through system Many online monitors available, also portable test kits

Key Points to Watch For Is water clean (low turbidity?) How is dose set? (Consider CT (dose x time), residual at furthest point and by-products) Is mixing adequate? Have they measured contact time under all flows? Stock control of hypochlorite (max 6 months, out of light / heat) Hypochlorite suitable for water use (incl. low bromate) Procedure for making up solution Control of dosing (regularly checked) Monitors maintained and calibrated Spare parts (pumps, lines, injectors)

Key Points to Watch For They should be regularly checking & recording: Dose rate (pump settings) Hypochlorite solution concentration (or) Cl residual after dose (and at point of use) pH Equipment condition (pumps, hoses, injectors) If you find THMs: Check dose and residuals (too high?) Quality of incoming water (organics?) Residence times (tanks, large pipes) Any recirculation (multiple doses of chlorine)

Questions TCL1 Could undisinfected water pass into supply? (Has the chlorine dosing system appropriate alarms or an automatic shutdown arrangement?) Automated chlorine dosing units may operate with a standby system in place, ensuring that chlorine continues to be dosed at the appropriate level if the main chlorination system fails (for example if the supply runs out, or a dosing line blocks). This will help ensure water is subject to disinfection at all times. TCL2 Could lack of maintenance compromise the disinfection process? Refer to the maintenance regime recommended by the manufacturer and ask for written documentation that this is being adhered to, including servicing. Such documentation includes entries in a log book, diary records, and full records. TCL3 Is there a risk of loss of chlorine dosing going undetected due to lack of appropriate alarms and shutdowns? Determine what alarms are in place to alert the operator to any loss of chlorine dosing, and whether this is linked to any automatic shut down of the supply to prevent undisinfected water entering the supply. TCL4 Is there a risk of contamination due to use of chemicals of inappropriate grade, i.e. not approved for use in drinking water supplies? Chemicals used in a chlorination system must be approved for use with drinking water supplies and comply with Regulations. TCL5 Could disinfection be compromised due to incorrect storage of chemicals or excessive storage times? Hypochlorite storage should not exceed 6 months as its strength will reduce and there is an increasing risk of byproducts such as chlorate forming. Poor storage conditions can exacerbate this degradation or render the disinfectant ineffective. TCL6 Is there a possibility of incorrect making up / diluting of hypochlorite solution? Users should be aware of the strength of hypochlorite solution required and how this is made up. Clear instructions should be present on site and all chemicals and equipment should be clearly labelled. TCL7 Could there be confusion over the target chlorine residual (is it documented and appropriate?) The target chlorine residual should be set at an appropriate level and this must be clearly documented on site. TCL8 Is there a risk of poor control of disinfection due to lack of residual monitoring? Chlorine demand can vary rapidly, meaning that the amount of chlorine available to disinfect the water can change, putting effective disinfection at risk. It is important that chlorine residual is monitored regularly (ideally continuously via online monitors) and chlorine doses are adjusted accordingly. TCL9 Is there a risk of inadequate contact time under some flow conditions? Chlorine needs adequate contact time (Ct) with the water in order to disinfect effectively. A suitable contact tank or pipe should be present that ensures sufficient contact time at all flows (it may be necessary to restrict the maximum flow to enable this). Ct is a measure of disinfection and is calculated by multiplying the chlorine residual in mg/l by contact time in minutes. The appropriate Ct for a given system and water quality is best decided by an expert, but 10 is a reasonable minimum value for a good quality raw water. TCL10 Is there potential for by-product formation (primarily THMs?) Where waters are high in organic material and/or chlorine doses are poorly controlled or very high, disinfection by-products such as trihalomethanes may be formed. Formation of these can be controlled by improving removal of organics (colour) prior to chlorine addition, improving control of chlorine dosing and minimising water age.