CLRS 321 Nuclear Medicine Physics & Instrumentation I

Slides:



Advertisements
Similar presentations
Semiconductors Chapters
Advertisements

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Detecting Ionising Radiation James Gray University RPA.
Diode detector (PIN photo diode detector)
Liquid Scintillation Counter And Contamination Monitoring Training Presented by: Ali Shoushtarian Office of Risk Management October 2009.
Radiation Safety Course Radiation Monitoring Heath de la Giroday Dispensing Chemist Radiation Safety Officer.
Detecting and Measuring Ionizing Radiation -2
Nuclear Radiation Basics. Copyright © 2011International Medcom Contents What is Radiation? What is Radiation? Instruments that Measure Nuclear.
X-ray Astronomy Lee Yacobi Selected Topics in Astrophysics July 9.
Kristin Ackerson, Virginia Tech EE Spring A DIODE IS A SEMICONDUCTER DEVISE, IT A ACTIVE COMPONENT WHOSE PROVIDE BEST FLOW OF CURRENT. IT IS A PN.
Radiation Safety level 5 Frits Pleiter 02/07/2015radiation safety - level 51.
Unit-II Physics of Semiconductor Devices. Formation of PN Junction and working of PN junction. Energy Diagram of PN Diode, I-V Characteristics of PN Junction,
Measurement and Detection of Ionizing Radiation
Gamma Spectroscopy HPT TVAN Technical Training
2: Radiation Measurements
Radiation Detection and Measurement II IRAD 2731.
SPECIAL DIODES P. SYAM SUNDAR ASSOCIATE PROFESSOR DEPT. OF ECE K L UNIVERSITY.
. 2 RCRS provides: Pick-up and delivery of meters Required 9-month calibration Preventive maintenance and repairs Shipping for extensive repairs RCRS.
Detectors The energy loss of particles in matter can be used detect and identify those particles. There are different types of “detectors”: - Gas-filled.
Principles of Radiation Detection
Chapter 6 Principles of Radiation Detection. Measurement of Radiation X-rays and electrons produced by radiation therapy treatment machines are measured.
DETECTION AND MEASUREMENT OF RADIOACTIVITY 1 NANIK DWI NURHAYATI,S.SI,M.SI.
Instruments for Radiation Detection and Measurement Lab # 3 (1)
CLRS 321 Nuclear Medicine Physics & Instrumentation I Part C: Semiconductors and Miscellaneous Scintillation Devices Unit II: Nuclear Medicine Measuring.
Half-life It's impossible to predict when a specific atom is going to decay, but you can predict the number of atoms that will decay in a certain time.
GERMANIUM GAMMA -RAY DETECTORS BY BAYAN YOUSEF JARADAT Phys.641 Nuclear Physics 1 First Semester 2010/2011 PROF. NIDAL ERSHAIDAT.
Instrumentation Review. Direct and Indirect Ionization Direct - Charge particles that strip away electrons from atoms Indirect - uncharged that have to.
ELECTRONIC PROPERTIES OF MATTER - Semi-conductors and the p-n junction -
Introduction to nuclear medicine technology NMT 231 Aya Ahmed Saeed.
Radiation detection and measurement
Session II.3.7 Part II Quantities and Measurements
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Types of Semiconductor Detectors
Chapter 21 Section 3 Nuclear Radiation Nuclear Radiation.
Ideal Detector Fast Cheap Rugged Responds to all wavelengths of light Can distinguish different wavelengths Sensitive Low LOD.
Neutrinoless double beta decay (0  ) CdTe Semico nductor Band gap (eV) Electron mobility (cm 2 /V/s) Hole mobility (cm 2 /V/s) Density (g/cm 3.
INTRODUCTION TO SEMICONDUCTORS
COURSE NAME: SEMICONDUCTORS Course Code: PHYS 473.
3/2003 Rev 1 II.3.5 – slide 1 of 23 IAEA Post Graduate Educational Course Radiation Protection and Safe Use of Radiation Sources Session II.3.5 Part IIQuantities.
Nuclear Medicine Physics Jerry Allison, Ph.D. Department of Radiology Medical College of Georgia Radiation Detectors.
Physics of Semiconductor Devices
More Applications of PN Junction
It converts light energy into electrical energy.
Radiation Protection RTMR 284 CHAPTER 20 PART II.
Physics of Semiconductor Devices Mr. Zeeshan Ali, Asst. Professor
Topic 6 : Atomic and Nuclear Physics.
Chapter 1: Semiconductor Diodes
Photovoltaic and dye-sensitized solar cells
BSIC SEMICOCONDUCTOR CONCEPTS INTRINSIC SILICON:
Semiconductor Devices
Radio active measuements
Semiconductors. Silicon crystal Types of semiconductors
Lecture 4(Unit II): Gas-Filled Detector Quality Control
Lecture 1: Basic Electronics Unit II: Gas-filled detectors
CLRS 321 Nuclear Medicine Physics & Instrumentation I
Gamma-Gamma Correlations in Na-22
Chapter 1: Semiconductor Diodes
Semiconductors Chapter 25.
Lecture 1—Basic Principles of Scintillation
Electronic Fundamental Muhammad Zahid
Radiation Sensors Radiation is emission if either particles or electromagnetic rays from a source. Particles are usually nuclear particles which can be.
ECE699 – 004 Sensor Device Technology
1 Principles of Radiation Detection Operational Radiological Safety Course U.S. Army Chemical Biological Radiological & Nuclear School Edwin R. Bradley.
Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Detecting Ionising Radiation James Gray University RPA.
Semiconductor Detectors
X-ray detectors single photon detectors
Detecting Ionising Radiation
Atomic Physics Radiation Contiuned.
BSIC SEMICOCONDUCTOR CONCEPTS INTRINSIC SILICON:
PN-JUNCTION.
Semiconductor Diodes Chapter 1 Boylestad Electronic Devices and Circuit Theory.
Presentation transcript:

CLRS 321 Nuclear Medicine Physics & Instrumentation I Lecture 1--Semiconductors Detectors (and Miscellaneous Scintillation Devices) Unit IV: Miscellaneous Aspects of Radiation Detection CLRS 321 Nuclear Medicine Physics & Instrumentation I

Objectives Describe n-type and p-type semiconductors and how they function as a radiation measuring device Describe the materials and construction of a semiconductor detector Discuss the detection and counting characteristics of a semiconductor radiation detection device and how these characteristics match up to scintillation detectors Discuss the use of semiconductor detectors in nuclear medicine Describe quality control measures for semiconductor detectors Explain the function of TLD ring and collar dosimeters Describe the function and uses of a liquid scintillation counter

What you need to know about how semiconductors work http://www.youtube.com/watch?v=PuZWoHa9mBo

Semiconduction Prekeges, J. (2010) Nuclear Medicine Instrumentation. Sudbury, MA: Jones & Bartlett. Figs 3-1 & 3-2, p. 29.

Semiconduction: p-n junction Extra electrons (n-type) move toward the anode Extra holes (p-type) tend to move toward cathode like +electrons When p & n types come together, the holes and electrons diffuse to opposite ends, but end up creating an opposite “intrinsic” charge Negative charge for p side Because the electron acceptor impurity has lost its holes Positive charge for n side Because the electron donor has lost its electrons

P-side has lost its extra holes (which makes it negatively charged) N-side has lost its extra electrons (which makes it positively charged) Diffusion of holes and electrons results in the charges pictured and the intrinsic charge Prekeges, J. (2010) Nuclear Medicine Instrumentation. Sudbury, MA: Jones & Bartlett. FigB-9, p. 275.

If the cathode (- terminal) is placed on the n-side, then this is called forward bias and the depletion layer narrows. If the anode (+ terminal) is placed on the n-side, then this is called reverse bias and the depletion layer widens. With reverse bias, the depletion layer becomes a solid-state ionization chamber Prekeges, J. (2010) Nuclear Medicine Instrumentation. Sudbury, MA: Jones & Bartlett. FigB-9, p. 275.

Prekeges, J. (2010) Nuclear Medicine Instrumentation Prekeges, J. (2010) Nuclear Medicine Instrumentation. Sudbury, MA: Jones & Bartlett. Fig 3-4 p. 31.

Detector Type Energy Conversions Gas-filled Detector 25-35 eV to make ion pairs Scintillation Detector 30 eV for scintillation Semiconductor 3-5 eV to make ion pairs FWHM (662 keV Cs-137 Source) NaI(Tl): 6 to 8% Semiconductor: 1.8 to 2.5%

Comparison of Information Carriers Prekeges, J. (2010) Nuclear Medicine Instrumentation. Sudbury, MA: Jones & Bartlett. p. 33.

Prekeges, J. (2010) Nuclear Medicine Instrumentation Prekeges, J. (2010) Nuclear Medicine Instrumentation. Sudbury, MA: Jones & Bartlett. Fig3-7, p. 34.

Seminconductor Energy Spectrum Prekeges, J. (2010) Nuclear Medicine Instrumentation. Sudbury, MA: Jones & Bartlett. Fig3-3, p. 30.

Semiconductor Materials Cadmium (Cd), Tellurium (Te), Zinc (Zn) ZnTe and CdTe common “CZT” semiconductor (or detector) Cd and Zn are electron acceptors Have “holes” and thus are p-type Te is an electron donor Extra electrons and thus an n-type

Semiconductor Probes Often have surgical applications Sentinel node biopsy Parathyroid adenoma localization Tumor localization http://www.battelle.org/solutions/?Nav_Area=Solution&Nav_SectionID=9&Nav_CatID=9_DeviceDevelopment&Nav_ContentKey={74FFB370-37E6-486A-8D46-DE7E9E29715E}

http://www.breastdiseases.com/sentno.htm Prekeges, J. (2010) Nuclear Medicine Instrumentation. Sudbury, MA: Jones & Bartlett. Fig 3-6 p. 32.

Quality Control for Semiconductor Probes Daily: Battery Check Background Determination Constancy Check (using Co-57 source) Quarterly or semiannually: Calibration (may need to be done by manufacturer) NEMA recommendations (annually): Sensitivity in air and scattering medium Energy, spatial, and angular resolution Volume sensitivity Count rate capabilities

Liquid Scintillation Detector Usually used in laboratories to count beta emitters. Solvents dissolve radioactive samples (often purposely radiolabelled) in to vials. Radioactivity scintillates a set of solutions in the vials. PMTs detect light from the “scintillation cocktails” in the vials. No longer routinely used in nuclear medicine http://ocean.stanford.edu/lab//labo.mpe.free.fr/img/materiel/scintill.JPG

Radiation Detection (formerly known as “film”) badges Al2O3 crystalline material becomes luminescent under selected laser frequencies. Luminescence is proportional to the amount of radiation exposure.

Thermoluminescent Dosimetry (TLD Ring Badges) Uses a lithium fluoride chip that absorbs the energy of ionizing radiation. It is then heated at characteristic temperatures that cause it to emit the absorbed energy as visible light. The amount of exposure is determined by the light intensities.

Next Time Factors Relating to Radiation Detection