K. Sedlak, A. Stoykov, R. Scheuermann

Slides:



Advertisements
Similar presentations
Advanced Neutron Spectrometer (ANS) Geant4 Simulations
Advertisements

NDVCS measurement with BoNuS RTPC M. Osipenko December 2, 2009, CLAS12 Central Detector Collaboration meeting.
T-979: SiPM Time Resolution with DRS4 Readout Anatoly Ronzhin, Fermilab, AEM March 12, 2012 Team: Mike Albrow, Sergey Los, Pasha Murat, Erik Ramberg, Fermilab.
Multi Pixel Photon Counters (MPPC) and Scintillating Fibers (Sci-Fi)
Performance of MPPC using laser system Photon sensor KEK Niigata university, ILC calorimeter group Sayaka IBA, Hiroaki ONO, Paul.
Microscope Performance at elevated dark rates Richard Jones University of Connecticut collaboration GlueX collaboration meeting, Newport News, Feb. 2-4,
Progress on the final TWIST measurement of James Bueno, University of British Columbia and TRIUMF on behalf of the Triumf Weak Interaction Symmetry Test.
Genova/Pavia/Roma Flavio Gatti, PSI, July 1st, Timing Counter july 2004.
Trend ground array 1 1.General considerations 2.Study on the prototype detector 3.Inclined ground array simulation 4.Making work plan in 2014.
Photon detection Visible or near-visible wavelengths
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
Characterization of Silicon Photomultipliers for beam loss monitors Lee Liverpool University weekly meeting.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
W  eν The W->eν analysis is a phi uniformity calibration, and only yields relative calibration constants. This means that all of the α’s in a given eta.
Status of the Beamline Simulation A.Somov Jefferson Lab Collaboration Meeting, May 11, 2010.
Feb 10, 2005 S. Kahn -- Pid Detectors in G4MicePage 1 Pid Detector Implementation in G4Mice Steve Kahn Brookhaven National Lab 10 Feb 2005.
The ALC spectrometer The ALC detector is embedded inside a 5 Tesla superconducting solenoid. The detector consists of a forward (FW) and backward (BW)
FLC Group Test-beam Studies of the Laser-Wire Detector 13 September 2006 Maximilian Micheler Supervisor: Freddy Poirier.
SiPM: Development and Applications
“End station A setup” data analysis Josef Uher. Outline Introduction to setup and analysis Quartz bar start counter MA and MCP PMT in the prototype.
5th July 00PSI SEU Studies1 Preliminary PSI SEU Studies Study SEU effects by measuring the BER of the link in  /p beams at PSI. Measure the SEU rate as.
Aldo Dell'Oro INAF- Observatory of Turin Detailed analysis of the signal from asteroids by GAIA and their size estimation Besançon November 6-7, 2003.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
Luminosity Monitor UKNF Meeting 7 June 2010 Paul Soler, David Forrest Danielle MacLennan.
PANDA Anton A. Izotov, Gatchina A.A.Izotov, Gatchina, PANDA Forward TOF Walls. Side TOF walls in dipole Magnet SiPM/PMT187.
1 Development of Multi-Pixel Photon Counters (1) S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira, K.Yoshimura, (KEK) Oct
Simonetta Gentile, LCWS10, March 2010, Beijing,China. G-APD Photon detection efficiency Simonetta Gentile 1 F.Meddi 1 E.Kuznetsova 2 [1]Università.
Optimization of Detectors for Time of Flight PET Marek Moszyński, Tomasz Szczęśniak, Soltan Institute for Nuclear Studies, Otwock-Świerk, Poland.
G4 Validation meeting (5/11/2003) S.VIRET LPSC Grenoble Photon testbeam Data/G4 comparison  Motivation  Testbeam setup & simulation  Analysis & results.
Development of Multi-Pixel Photon Counters(MPPC) Makoto Taguchi Kyoto University.
Test beam preliminary results D. Di Filippo, P. Massarotti, T. Spadaro.
26 Apr 2009Paul Dauncey1 Digital ECAL: Lecture 3 Paul Dauncey, Imperial College London.
Prospects to Use Silicon Photomultipliers for the Astroparticle Physics Experiments EUSO and MAGIC A. Nepomuk Otte Max-Planck-Institut für Physik München.
(s)T3B Update – Calibration and Temperature Corrections AHCAL meeting– December 13 th 2011 – Hamburg Christian Soldner Max-Planck-Institute for Physics.
T. Lari – INFN Milan Status of ATLAS Pixel Test beam simulation Status of the validation studies with test-beam data of the Geant4 simulation and Pixel.
Timing in Thick Silicon Detectors Andrej Studen, University of Michigan, CIMA collaboration.
Luminosity Monitor Design MICE Collaboration Meeting 31 May 2009 Paul Soler.
AMIGA – A direct measurement of muons in Pierre Auger Observatory
Genova/Pavia/Roma Flavio Gatti, PSI, 11 February, Timing Counter: january 2004.
1 Plannar Active Absorber Calorimeter Adam Para, Niki Saoulidou, Hans Wenzel, Shin-Shan Yu Fermialb Tianchi Zhao University of Washington ACFA Meeting.
Potential Advantages of Digitally Sampling Scintillation Pulses in Time Determination in PET Q. Xie 1,2, C.-M. Kao 1, X. Wang 2, N. Guo 2, C. Zhu 2, H.
Silicon Photomultiplier Development at GRAPES-3 K.C.Ravindran T.I.F.R, OOTY WAPP 2010 Worshop On behalf of GRAPES-3 Collaboration.
GSI 9Feb09 NMI3 – Integrated Infrastructure Initiative for Neutron Scattering and Muon Spectroscopy, Joint Research Activity (JRA8): MUON-S. Contract:
SiPM Workshop EU-FP7(HP3), Vienna, 16 Feb F.G. H.O. Study of scintillator detectors time resolution with different SiPM readout on T10 test beam.
M.Taguchi and T.Nobuhara(Kyoto) HPK MPPC(Multi Pixel Photon Counter) status T2K280m meeting.
P. Lecoq CERN2 February ENVISION WP2 Meeting CERN Group contribution to ENVISION WP2 Paul Lecoq CERN, Geneva.
Abstract The shape of the current pulse produced by a SiPM in response to an incident photon is sensibly affected by the characteristics of the FE used.
Development of Multi-Pixel Photon Counters (1)
A systematic study of cross-talk limitations in RPC timing
An Active TARget for MEG-II, a status report
Simulation of the Time Response of a VPT
An active target for MEG2, a status report
Frontier Detectors for Frontier Physics
MoNA detector physics How to detect neutrons. Thomas Baumann NSCL.
After-pulsing and cross-talk comparison for PM1125NS-SB0 (KETEK), S C (HAMAMATSU) and S CS (HAMAMATSU). Oleynikov V.P.*, Porosev V.V.
KM2A Electron Detector Optimization
Analysis of FADC single-crystal data
大強度
PAN-2013: Radiation detectors
Upgrade of LXe gamma-ray detector in MEG experiment
Timing Counter Sept CSN I, Assisi 2004 Giorgio Cecchet.
Neutron Detector Simulations for Fast Neutrons with GEANT4
md-NUV PET project meeting
PbWO4 Cherenkov light contribution to Hamamatsu S8148 and Zinc Sulfide–Silicon avalanche photodiodes signals F. KOCAK, I. TAPAN Department of Physics,
Neutron Detector Simulations for Fast Neutrons with GEANT4
R&D of MPPC in kyoto M.taguchi.
CLAS 12 Status of the test bench Calculation of the time resolution
西村美紀(東大) 他 MEGIIコラボレーション 日本物理学会 第73回年次大会(2018年) 東京理科大学(野田キャンパス)
p0 ALL analysis in PHENIX
Status Report on MCP PET Simulation
Presentation transcript:

K. Sedlak, A. Stoykov, R. Scheuermann Time-resolution with a fast plastic scintillator read out by a G-APD: a GEANT4 study K. Sedlak, A. Stoykov, R. Scheuermann The time resolution of a fast scintillation counter, consisting of a plastic scintillator read out by a Geiger-mode Avalanche Photodiode, is studied over a wide range of the number of detected photons using the GEANT4 simulation toolkit. Different timing definitions such as first photon detection, leading edge and constant fraction discrimination are considered. In the latter case the predictions are compared with the existing experimental data. Motivation Ideal vs. realistic G-APD Any real G-APD device has a finite number of cells, suffers from a crosstalk and from a time jitter of each individual cell, the so-called “single photon time resolution” (SPTR). To understand how these effects influence the time resolution, we started from an ideal G-APD with no cross-talk, infinite number of cells and SPTR=0 ps (see the left plot), and subsequently added the above mentioned effects. The predictions for the G-APD with a cross-talk of 12% and a realistic SPTR are shown in the right plot. For our application – the High-Field μSR spectrometer [1] – we need to detect ~10 MeV/c muons and positrons in the magnetic field of 0 – 9.5 T with extremely good time resolution. We use the BC-422 plastic scintillator read out by a G-APD (Hamamatsu MPPC S10362-33-050C), and process the signals by constant fraction discriminators (CFDs). Using a dedicated setup, we estimated the limit on the time resolution of such a detector as a function of energy E deposited in the scintillator and the number of photoelectrons Nphe (detected photons) in the G-APD [2]: σ1MeV = 18 ± 1 ps·MeV1/2 , σ1phe = 850 ± 5 ps [1] A.Stoykov et al., High Field µSR instrument at PSI: detector solutions, Physics Procedia 30 (2012) 7. [2] A.Stoykov, R.Scheuermann, K.Sedlak, A time resolution study with a plastic scintillator read out by a Geiger-mode Avalanche Photodiode, Nucl. Inst. and Meth. A – in press ( http://dx.doi.org/10.1016/j.nima.2011.11.011 ) In case of the ideal G-APD the best timing is achieved with t0.5cell (note that t0.5cell and tfirst are not equivalent). The CFD timing tCFD gives the worst result. Once the crosstalk and SPTR are included, the timing based on any time definition deteriorates. The CFD timing becomes the best – together with the leading-edge discrimination at 30·A1cell threshold*. *The leading edge discrimination, however, requires a time correction based on the signal amplitude. In our case the correction is perfect, since we have zero bin widths in Nphe. Geant4 study – simplified geometry A simplified setup based on just one scintillator box (2x3x3 mm2) and a single G-APD was implemented in Geant 4.9.5. The scintillator box was made of “G4_PLASTIC_SC_VINILTOULENE” material, its surface approximated as “polishedteflonair” defined in the Geant4 internal look-up tables. Converting photons into a G-APD signal An averaged 1-cell signal was obtained experimentally. Every time a photon is detected in the G-APD, the 1-cell signal is added up to the final analog pulse. Several analog pulses simulated this way using e- are shown in the left plot. Only the signals corresponding to 675 – 825 photons were selected. Finite number of cells If the number of cells is very large (in our case 2400 cells are optically coupled to the scintillator), the effect of the finite number of cells becomes negligible in our range of number of detected photons Nphe<17000. If the number of cells is substantially reduced, the time resolution gets worse, especially at large Nphe. In the limit case of just a single cell in the G-APD, the timings based on tfirst, tCFD and t0.5cell become identical. Definitions of timing tfirst – time when the first detected photon enters the G-APD. tCFD – time from a constant fraction discriminator triggering at 20% of the signal amplitude. t0.5cell – time when the signal reaches threshold of 0.5·A1cell , where A1cell is the average amplitude of the 1-cell signal. Figures on the left show the simulated time distributions for two extreme cases of 16 and 16421 detected photons (Nphe) in the single counter. The distributions were shifted to match their mean values in the case Nphe = 16421. We define the time resolution, σ(tdet ), as the standard deviation of a given time distribution. Comparison with the real experiment Finally we compared the simulation (this time reproducing the geometry of two counters) with the real measurement. In case of SPTR=120ps, the Geant4 prediction reproduces the measurement rather well. First photon study Theoretically [3], the time resolution σ(tfirst) should follow the dependence: σ(tfirst) = τ2 / Nphe for a scintillator with zero rise time (τ1 = 0) and the decay time τ2 (in our case 1.6 ns). The left plot confirms this dependence for a scintillator with zero rise time and for an infinitely small size. Both finite rise time and finite scintillator size (just in a mm range!) significantly deteriorate the time resolution at large Nphe. (An ideal G-APD was assumed here – see later.) Conclusions The timing at large Nphe in a counter with a realistic G-APD can be significantly deteriorated by the single photon time resolution (SPTR). Most affected by this parameter are the first photon detection and the leading edge discrimination with the lowest threshold. The simulation confirms the theoretically predicted dependence of the time resolution for the first photon: σ(tfirst) = τ2 / Nphe . This dependence is valid only in idealised conditions (breaks down for a finite rise time or finite scintillator size). In a real scintillation counter using the fastest plastic scintillator (BC-422) and, to our opinion currently best suited for its readout G-APD (Hamamatsu MPPC S10362-33-050C), the CFD timing method yields practically the best result. In principle, a slightly better timing could be achieved with a well tuned leading edge discriminator (but requires a time correction based on the signal amplitude). [3] R.F.Post, L.I.Schiff, Statistical limitations on the resolving time of a scintillator counter, Phys. Rev. 80 (1950) 1113. This research project has been supported by the European Commission under the 7th Framework Programme through the 'Research Infrastructures' action of the 'Capacities' Programme, NMI3-II Grant numbers 226507 and 283883.