Block 4 and Cluster D - Safety

Slides:



Advertisements
Similar presentations
Interface issues on Super-FRS magnets test at CERN CrYogenic Department in Common System (CSCY) GSI, Darmstadt Yu Xiang Meeting for Super-FRS magnets test.
Advertisements

Design pressure issues of Super-FRS dipole CrYogenic Department in Common System (CSCY), GSI, Darmstadt Yu Xiang, Hans Mueller* * Primay Beam Magnet Technology.
MICE Hydrogen System Implementation Tom Bradshaw Elwyn Baynham Iouri Ivaniouchenkov Jim Rochford.
1 Infrastructure at RAL Iouri Ivaniouchenkov, RAL MICE Collaboration CERN, 29 March 2003.
Interface issues on Super-FRS magnets test at CERN
2 Technical seminar - 5 th June 2014 Vincent Roger - TE-MSC-TF.
HQ TEST CERN by Marta Bajko CERN TE-MSC TF For Hi Lumi and LARP the 16 th of November 2011 CERN.
23 Jan 2007 LASA Cryogenics Global Group 1 ILC Cryomodule piping L. Tavian for the cryogenics global group.
ESS Cryogenic Distribution System for the Elliptical Linac CM - CDS requirements Preliminary Design Review Meeting, 20 May 2015, ESS, Lund, Sweden J. Polinski.
The HiLumi LHC Design Study (a sub-system of HL-LHC) is co-funded by the European Commission within the Framework Programme 7 Capacities Specific Programme,
Helium Spill Test in LHC tunnel to define length of restricted working areas  Actual situation  Evolution  How to continue  Set-up of the spilling.
Cryomodule Helium Vessel Pressure -- a Few Additional Comments Tom Peterson 18 November 2007.
IHEP 1.3 GHz Cryomodule and Cryogenics IHEP Cryogenic group 2nd Workshop of the IHEP 1.3 GHz SRF R&D Project Dec 2 nd, 2009.
Hydrogen system R&D. R&D programme – general points Hydrogen absorber system incorporates 2 novel aspects Hydrogen storage using a hydride bed Hydrogen.
HOW THE DUMP RESISTOR’S TANK LOOKS LIKE COOLING OF THE LHC ENERGY EXTRACTION RESISTORS G. Peón (ST/CV), K. Dahlerup-Petersen, G. Coelingh (AT/MEL) Air.
Arnaud Vande Craen (TE-MSC) 27/02/20131 EUCARD : ESAC Review – CEA Saclay.
Cryogenic update before Fermilab meeting (and after the helium tank review) Coordination meeting 6 th May 2015 K. Brodzinski HiLumi-LHC-CC-Cryo-PPT-18_v1.
Preliminary Design for the Coupling Coil Cryostat in MICE
Hall D Target System Review J. FochtmanSeptember 28,2011 Preliminary Design Work.
Full Scale Thermosyphon Design Parameters and Technical Description Jose Botelho Direito EN/CV/DC 19 November, th Thermosyphon Workshop.
L. Serio COPING WITH TRANSIENTS L. SERIO CERN, Geneva (Switzerland)
9/17/07IRENG071 Cryogenic System for the ILC IR Magnets QD0 and QF1 K. C. Wu - BNL.
Process Definition of the Operation Modes for Super-FRS Magnet Testing CSCY - CrYogenic department in Common System, GSI, Darmstadt Y. Xiang, F. Wamers.
Plan for test station Marta Bajko For the Technical Review of FReSCa2 June 2015 Saclay Paris.
[R. Alemany] [CERN AB/OP] [Engineer In Charge of LHC] HWC Workshop ( ) Consolidation and major changes that have impact on the powering circuits.
Dimensions, pressures and temperatures of cryogenic circuits for the SPL U. Wagner TE-CRG.
AT-ACR B. VULLIERMECSOC Meeting 29 September Cryogenics for LHC Test Benches Safety Aspects Overview of the Test Station Overview of the Operation.
Mike Struik / LHC-CRI INSTRUMENTATION FEEDTHROUGH SYSTEM FOR LHC MACHINE ARC QUADRUPOLE MAGNETS. 123rd LHC Vacuum Design Meeting 19 April 1999.
MAGNET#1MAGNET#2MAGNET#3 SATELLITE VB#1 SATELLITE VB#2 SATELLITE VB#3 PRECOOLER#1PRECOOLER#2 DISTRIBUTION VALVE BOX DVB CP#1CP#3CP#2 BUFFER DEWAR LHe 5m.
Cryogenic scheme, pipes and valves dimensions U.Wagner CERN TE-CRG.
Date 2007/Sept./12-14 EDR kick-off-meeting Global Design Effort 1 Cryomodule Interface definition N. Ohuchi.
Crab cavities – cryogenics for SPS and LHC LHC-CC13, 6 th LHC Crab Cavity Workshop – CERN, Geneva, Switzerland 9-11 December 2013 K. Brodzinski on behalf.
Duy Phan, EN-STI-RBS. Description of the hazards  An Oxygen Deficiency Hazard (ODH) exists when the concentration of O2 ≤ 19.5 % (by volume)  Cold burns.
8/29/07K. C. Wu - Brookhaven National Lab1 Major Components in ILC IR Hall Interchangeable Detectors.
Vacuum tank relief for Super-FRS long multiplet cryostat CrYogenic Department in Common System (CSCY) GSI, Darmstadt Yu Xiang.
Overview of the ESS Linac Cryogenic Distribution System
Bruno Vullierme Sept LHC-CC09 - 3rd LHC Crab Cavity Workshop Slide 1 CRAB CAVITY INTEGRATION CRYOGENICS INSTALLATION.
Overview of elliptical cryomodules vacuum system Vacuum Equipment Standardization meeting February 2014 P. Bosland – C. Darve – N. Elias.
The Large Hadron Collider The 19 th Sep 2008 incident [R. Alemany] [CERN AB/OP] [Engineer In Charge of LHC] NIKHEF Seminar ( )
TEST FACILITY STATUS FOR TESTING CERN Marta Bajko WP10. EUCARD 2 Task 4 - HTS Magnet Tests, June 2015.
Crab Cavities SPS cryogenics – progress and requirements Fermilab visit at CERN 02 August 2013 Krzysztof Brodzinski (on behalf of CERN cryogenic team)
Max-Planck-Institut für Plasmaphysik 1 ICEC 26- ICMC 2016 March 7-11, 2016, New Delhi, India Michael Nagel Cryogenic commissioning, cool down and first.
Internal review of superconductors and magnet laboratories 2nd part: SM 18 & b.163: current status, weak points, possible improvement Cryogenics Vladislav.
ESS | Helium Distribution | | Torsten Koettig Linac – Helium distribution 1.
S A Griffiths CM42 June 2015 Electrical & Control.
Design Status of the Spoke Cryomodule for MYRRHA SLHIPP Louvain la Neuve 17-18/04/2013 Design Status of the Spoke Cryomodule for MYRRHA SLHIPP Louvain.
Hongyu Bai LCLS-II 2 K Cold Box PDR September 27, 2016
Final Design Cryogenic and mechanical configurations
2 K Coldbox Safety and ESH
Existing Prototype Test Facility (PTF) and planned Series Test Facility Schroeder, Claus Cryo-Review Darmstadt
Design of the thermosiphon Test Facilities 2nd Thermosiphon Workshop
HL-LHC IT STRING and Series test of SC link
IT-4189 Supply and installation of a cryogenic distribution system
Cryogenic behavior of the cryogenic system
HFM Test Station Main Cryostat
LARP Vertical Test Facility
Hongyu Bai LCLS-II 2 K Cold Box FDR March 9, 2017
CERN Cryomodule Requirements for Crab Cavities
Status of the cryogenic system for B180
Cryostat design Mechanical design: Thermal screens: Specifications:
2K Cold Box Process Design
ILC Experimental Hall Cryogenics An Overview
Cooling aspects for Nb3Sn Inner Triplet quadrupoles and D1
ESS elliptical cryomodule
ESS elliptical cryomodule
Cryogenic behavior of the magnet
Thermohydraulic behaviour of the cryogenic system
Burst Disc Experiences at CEA Test Stand
Review Bloc 4 and SM18 facilities and upgrade
Design and integration of safety equipment and safety aspects in the LHC tunnel (cryogenic safety only) Vittorio Parma Th.Otto.
Presentation transcript:

Block 4 and Cluster D - Safety V. Benda 22/09/2016 Bloc 4 and Cluster D - Safety, CERN/TE/CRG/VB

Bloc 4 and Cluster D - Safety, CERN/TE/CRG/VB SM 18 overview Horizontal test facility For LHC magnets Cluster G (Block4) Vertical test facility For prototype magnets 22/09/2016 Bloc 4 and Cluster D - Safety, CERN/TE/CRG/VB

Bloc 4 and Cluster D - Safety, CERN/TE/CRG/VB Cluster G layout HFM quench buffer Long cryostat, 1.9 K Siegtal cryostat, 1.9 K HFM cryostat, 1.9 K Diode/Current leads cryostat, 4.5 K 22/09/2016 Bloc 4 and Cluster D - Safety, CERN/TE/CRG/VB

Bloc 4 and Cluster D - Safety, CERN/TE/CRG/VB Cluster G cryostats Diode/ Current leads cryostat S=4 m2 Siegtal cryostat S=8 m2 Long cryostat S=11.2 m2 HFM cryostat S=25 m2 Cluster D cryostat S=23 m2 22/09/2016 Bloc 4 and Cluster D - Safety, CERN/TE/CRG/VB

HFM and Cluster D layout Quench buffer Test cryostat Main line Quench line Valve box Helium rack Precooling line Combined line Cluster D Working temperature: 1.9 K Magnet energy: 10 MJ Test volume: D=0.8m, L=5m Cluster D integrated in CFB clusters The station shall be ready for commissioning in November HFM Working temperature: 1.9 K Magnet energy: 10 MJ Test volume: D=1.5m, L=2.5m Quench line Quench buffer Precooling line Supply line Main line Helium rack Valve box Test cryostat HFM integrated in the Cluster G The first cold test (without magnet) was successfully finished in August The first magnet test is foreseen for beginning of October 22/09/2016 Bloc 4 and Cluster D - Safety, CERN/TE/CRG/VB

Bloc 4 and Cluster D - Safety, CERN/TE/CRG/VB Safety strategy and pressure parameters Siegtal cryostat, Long cryostat and Diode/Current leads cryostat Main safety valve protects the cryostat against lost of insulating vacuum and quench in the same time Very low probability, GHe to atmosphere in SM18 Quench relief valve Nominal operation, GHe to balloon (recuperation) Set pressure for Siegtal and Long cryostat Main safety valve: 2.1 bar gauge Full safety valve opening: 2.31 bar gauge ( 10% more) dP of inlet < 3% and outlet line < 7% has to be respected Set pressure of quench relief valve (only for quench): 1 bar gauge Full opening at 1.1 bar gauge Set pressure for Diode/Current lead cryostat Setting of the main safety valve is: 1.4 bar gauge Only the main safety valve as there is no possibility of quench On a basis of risk analysis it was decided not to install a rupture disk in parallel with the safety valve. 22/09/2016 Bloc 4 and Cluster D - Safety, CERN/TE/CRG/VB

Siegtal process and instrumentation diagram 22/09/2016 Bloc 4 and Cluster D - Safety, CERN/TE/CRG/VB

Siegtal cryostat geometry for inlet pipe dP calculation 22/09/2016 Bloc 4 and Cluster D - Safety, CERN/TE/CRG/VB

Strategy of SV/RD calculation adopted for Cluster G and D Back pressure 1 bara Risks taken into account Lost of vacuum If insulated by 10 layers of MLI Qvac=6 kW/m2 If not isolated (line between the cryostat and the safety valve ) Qline=38 kW/m2 Quench Estimation based on LHC dipole Qq=1 kW/m to LHe Total heat in-leak QT = Qvac + Qline +Qq Calculation principle mv=QT/Lv total vaporized mo=mv(1-ρg/ρl) out of cryostat mo/A=Kdr P C (M/Z T)1/2 (ISO4126) A is the required surface of the safety valve Requirements on the pipes connected to SV: Inlet line dPin < 3% of P Outlet pipe dPout <7% of P Note If the non isolated line between the cryostat and the safety valve is too long the calculation will not converge To reduce dPin diameter of inlet line shall be increased If the diameter is increased: Qline is larger > QT is larger >mo is larger>dP is larger Non insulate part of the inlet line shall be as short as possible Outlet line L2 [m], D2 [m], dP1 Model Safety valve P[barg], DN [mm2] Inlet line S1 [m2], L1 [m], D1 [m], dP1 Lost of insulation vacuum GHe Cryostat Scr [m2] Air condensation LHe Quench Magnet Vacuum MLI 22/09/2016 Bloc 4 and Cluster D - Safety, CERN/TE/CRG/VB

Siegtal, dimensioning of safety valve SV calculation for the following parameters Qvac heat in-leak in case of a cryostat vacuum lost Qvac=Scr x qvac = 8 x 6 = 48 kW Qq heat coming into LHe during magnet quench On a basis of LHC magnet measurement it is estimated to 5 kW Qline heat in-leak into the insulated line Qline=Sline x qline = 1 x 38 = 38 kW QT=Qvac+Qq+Qline= 91 kW Set pressure 2.1 barg For calculation Pc=3.31 bar absolute For QT and Pc the following parameters of the safety valve were found mo=4.97 kg/s, S=2358 mm2, di=54.8 mm dP of the inlet line base of its geometry is 2 % < 3% Outlet pipe directly to atmosphere Safety valve LESER DN65, P=2.1 barg (S=2830 mm2) was chosen 22/09/2016 Bloc 4 and Cluster D - Safety, CERN/TE/CRG/VB

Safety valve for Siegtal cryostat by Kryolize 22/09/2016 Bloc 4 and Cluster D - Safety, CERN/TE/CRG/VB

Siegtal, dimensioning of quench relief valve QT= Qq+Qline= 50 kW Set pressure 1 barg For calculation Pc=2.1 bar absolute For QT and Pc the following parameters of the quench relief valve were found mo=2.73 kg/s, S=1652 mm2, di=45.9 mm dP of the inlet and outlet pipe is not strictly restricted as the quench relief valve is not considered as the safety valve In any case dp in the inlet line is lower that 3% and in outlet line lower that 7% Safety valve LESER DN50, P=1 barg (S=1662 mm2) 22/09/2016 Bloc 4 and Cluster D - Safety, CERN/TE/CRG/VB

Long cryostat, “SV” behaviour during a magnet quench 3000 mbar SV set pressure: Ps=1 barg Full opening at 2.1 bara 2300 mbar 2100 mbar SV to be fully opened 2000 mbar 1000 mbar 22/09/2016 Bloc 4 and Cluster D - Safety, CERN/TE/CRG/VB

Bloc 4 and Cluster D - Safety, CERN/TE/CRG/VB HFM P&I diagram 22/09/2016 Bloc 4 and Cluster D - Safety, CERN/TE/CRG/VB

HFM quench & catastrophic scenario SV: Quench + cryostat vacuum loss RD: Quench+ vacuum loss of cryostat, valve box & quench buffer RD, DN100 5.5 barg SV, DN80 4 barg 15 m3 22/09/2016 Bloc 4 and Cluster D - Safety, CERN/TE/CRG/VB

Bloc 4 and Cluster D - Safety, CERN/TE/CRG/VB Protection of 1.9 K pumping circuit of HFM Similar system is applied for Cluster D, other cryostats of Cluster G including 1.9 K common line 1.9 K common pumping line G/L HX, S=1.5 m2 L/L HX, S=3 m2 He guard box RD, 3 barg Svin, 1.1 barg Svout, 1 barg Valve box Cold buffer, S=2 m2 SV: only L/L HX is full of LHe SVin: QT=24 kW, Pb=2.1 bara, Pr=3.31 bara, q=6 kW/m2, ST=4 m2 Result: S=641 mm2, (d=28.6 mm), m=1.276 kg/s Safety valve: DN32, P=1.1 bar gauge SVout: Pb=1 bara, Pr=2.1 bara, m=1.276 kg/s Result: S=777 mm2, (d=31.4 mm) Safety valve: DN40, P=1 bar gauge RD for case that also the pumping line including the cold buffer and G/L HX is full of LHe and vacuum barrier 1 is broken QT=45 kW, Pb=1 bara, Pr=4 bara, q=6 kW/m2, ST=7.5 m2 Result: S=777 mm2, (d=31.2 mm), m=2.1 kg/s Rupture disk: DN32, P=3 bar gauge Vacuum barrier 2 in the valve box Vacuum barrier 1 Pipe, S=1 m2 in the cryostat 22/09/2016 Bloc 4 and Cluster D - Safety, CERN/TE/CRG/VB

Cryogenic pipe with cold GHe Strategy for SV calculation Heat in-leak for determination of a SV is for no moving gas in a pipe low Typically 700 W/m2 For long pipe during relieving a speed of leaving gas grows and heat exchange improves accordingly. At some speed the heat exchange inside the pipe is better than outside. In this case the limitation of heat exchange is the same as for pipe/vessel with LHe Typically 6 kW/m2 Detail study of this dynamic process would be appreciated 22/09/2016 Bloc 4 and Cluster D - Safety, CERN/TE/CRG/VB

Recommendation/Notes Risk analysis of each concrete case to be done Especially for more complex systems Additional heat in-leak (quench), divided vacuum space Installation of RD in parallel with SV if justified Heat in-leak determination Vacuum loss, number of MLI layers, extra heat in-leak Pressure drop of the inlet and outlet pipe Shortest pipes are the best Non insulated inlet pipe to be as short as possible Very high extra heat in-leak, typically 38 kW/m2 System is not converging If SV and RD are installed in parallel the inlet pipe has to be calculated for the worse possible case concerning dP If a hose is used; its dP is about 4x larger than for a smooth pipe… 22/09/2016 Bloc 4 and Cluster D - Safety, CERN/TE/CRG/VB