Risk Assessment should include:

Slides:



Advertisements
Similar presentations
CONTROLS OF SUPER CRITICAL BOILERS
Advertisements

Coach Air Conditioning
Antero Punttila Analyzing most typical energy saving measures Energy Efficiency of Steam and Condensate Systems Antero Punttila, Motiva Oy.
INTRODUCTION. Seminar on IMPROVEMENT OF THERMAL EFFICIENCY BY RECOVERY OF HEAT FROM IC ENGINE EXHAUST.
Circulating Water System
Customer Service – International Dept. The thermal solar systems  Installation  Commissioning  Maintenance.
The I 2 Air Fluid Protocol; The Eco-friendly method for eliminating bio-fouling in heat exchangers and cooling towers utilizing I 2 infused mixed media.
Hot Water Temperature Maintenance
Environmental Controls I/IG Lecture 14 Mechanical System Space Requirements Mechanical System Exchange Loops HVAC Systems Lecture 14 Mechanical System.
Unit 206: Domestic hot water systems
Aquascan. Aquascan - Introduction Aquascan is an online instrument capable of simultaneous multi-parameter measurement for a full range of water quality.
HACCP School Development Project Chapter 9 Storage By Andrea Boyes and Julia Wood Srednja šola Zagorje.
Cold feed to hot water cylinder Sink Basin Bath Drain valve Stop valve WC cistern 100 litre (minimum storage cistern)
Proposed Modifications in Boiler Feed Tank By: D K Singhal
Cooling As working temperatures rise, the strength of metals used reduces. This in turn will force manufacturers to use superior metals/alloys, which can.
Potential Pathways for Coliform Contamination. Fixing Positive Coliform Results.
Keeping Milk Cold.
Calcite Contactors for Corrosion Control
©2007 Armstrong International, Inc. Instantaneous Water Heater Flo-H 2 0 ™ Water to Water Instantaneous Water Heater Flo-H.
1 Introducing.... Legionella Intelligence Temperature monitoring and compliance Medical Intelligence Temperature monitoring and compliance Boiler Intelligence.
Queries Are soap and drying facilities compulsory in toilet areas? Are soap and drying facilities compulsory in food handling areas? Should we stop recommending.
LEGIONELLA MANAGEMENT & CONTROL NUQPR024 V
Unit 205: Cold water systems
Harnessing Free Heat. The Energy Harness provides hot water using multiple heat sources, making the best use of low grade heat. It improves the efficiency.
Health and Safety Manual Section L6 Legionella. Legionella L6 is a single set of standards for the management of Legionella bacteria, based on the HSE.
Unit 206: Domestic hot water systems
Lesson One.
Legionnaires’ disease – The hidden killer in water systems Managing the Risk presented by Karl Collingwood Wednesday 26 February 2014.
Health and Safety Executive Control of Legionella Howard Whittaker Principal Inspector FOD Leeds.
Pump Installation Vigyan Ashram, Pabal.
Chapter 12: Alternative Technologies To be used with the Guide to Building Energy Efficient Homes in Kentucky.
Gary C Akers Technical Manager. * No wall clutter. * Reduced risk of clashes. * Aesthetically pleasing. * Site benefits. * Environmental benefits. * Cooling.
Presentation on Installation of a Domestic Cold Water Storage Cistern
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
Mechanical for Oil Heat
Legionella control in the University of Sheffield Legionella Awareness for Departmental representatives.
The Cooling System.
WHAT’S in the PIPELINE? Tobias van Reenen CSIR
Legionella Risk Assessment Mike Rose. Legionella Risk Assessment Identification and evaluation of sources of potential risk Means by which exposure is.
Plan 2 – Dead-end Seal Chamber Optional Jacket
HVAC523 Basic Subsystems.
©2006 Armstrong International, Inc. Legionella. What is it and how do we treat it?
Safe Operation of Storage Tanks: Decommissioning and Repair
LEGIONELLA AWARENESS COURSE. COURSE OBJECTIVES To enable you to be aware of issues associated with Legionella within the UoP & be able to assist in the.
1 © 2015 Farm Energy Centre Today’s programme 10:00 amRegistration 10:30 amWelcome and introduction Heating system types and main components 11:30 amCoffee.
Presentation on Feed and Expansion Cistern. Central Heating At the end of this part you should be able to: Identify general system methods of feed and.
ANA Food Code. Responsibilities Commanders Take appropriate actions to make sure corrective actions are completed when a facility fails to comply to standards.
Health and Safety Executive Health and Safety Executive LEGIONNAIRES’ DISEASE AND GAS SAFETY: Landlords’ responsibilities Sue Matthews HM Inspector of.
REDUCING SCALE DEPOSITION BY PHYSICAL TREATMENT Sungmin Youn and Professor X. Si, Calvin College REDUCING SCALE DEPOSITION BY PHYSICAL TREATMENT Sungmin.
What is Conduction? Conduction is the transfer of heat energy from one substance to another substance through direct contact.
LEGIONELLA MANAGEMENT & CONTROL. LEGIONELLACEAE Legionella = aquatic bacteria Naturally widespread in the environment 52 different species identified.
of blood and components
Direct Hot Water. What Cold Water System is Pictured? What hot Water System is Pictured?
Legionella Awareness East Anglia Construction Safety Group 23 April 2009.
HOT WATER Understand and apply domestic hot water system installation and maintenance techniques.
Legionnaires Disease – what landlords need to know! John Blackwood Chief Executive Scottish Association of Landlords.
Kate Brierley Nurse Consultant in Health Protection Cumbria and Lancashire Health Protection Unit NW Regional Lead for HCAI March 2012 Legionella in Residential.
ACTIVE SOLAR DESIGN ALTERNATIVE ENEGRY SOURCES.
Domestic Hot Water Recirculation Design
Lecture (9): Monitoring & sampling methods, maintenance ,
RESIDENTIAL PLUMBING SYSTEMS (WATER SUPPLY)
HWAT Revival Special focus on hospitals Hygiene Flexibility Economy.
Treatment – Chlorine Disinfection
Hot water Systems Heaters.
5508BESG Services and Utilities Lecture 2
Hot Water Systems Cylinders and Systems.
Legionnaires’ disease
Treatment – Sediment Filters
Treatment – Plant Design
Session 4, Activity 2: Slides for interactive work
Presentation transcript:

Risk Assessment should include: the management responsibilities and name of the responsible person; an assessment & comprehensive schematic (where complex) of the system; details of precautions taken including: - the control method/s – inspection / monitoring and maintenance programme (eg checking the system is kept clean; records of operation, monitoring and remedial work; population exposed and risk Risk assessment should include: Responsibilities of competent person An assessment of the system present. Consideration of boiler type / method of heating etc. & detailed schematic drawing Identification and implementation of control measures Remedial action to further reduce risk e.g. removal of deadlegs / fitting of insect screens / raising of hot storage temps if required. Record keeping – this will need to show monitoring is in place, correct temperatures are maintained and that any departure from this is identified and remedied within reasonable time period.

Example of a good schematic Good example of a schematic Enables sentinels to be identified and where outlets are supplied from. NB complex system owing to large number of cold water tanks and calorifiers.

Methods of control of legionella in hot and cold water systems temperature regime; biocide treatments; ionisation treatment; ozone; and UV treatments This presentation concentrates on temperature control – however, there are other methods of control that can be used. These can be used in addition to temperature [See developments on copper / silver ionisation]

Temperature parameters 700C- rapid kill to 100% 600C -90% killed in 2 minutes 50 0 C -90% killed in 2 hours 45 0 C Bacteria 20 0C bacteria remains dormant but viable Avoid temperatures in range 20-50 degrees Celsius

H&CW System Simplified view of hot and cold water storage system with circulating hot loop. Storage of both hot and cold water are the most ‘at risk’ systems in H&SC sector as they require controls to ensure that storage and pipework remains clean and temperatures are maintained

Overview of Temp controls Distribute cold water at <200C Store cold water at <200C Note – Hot water should achieve 500C within 1 minute & cold should achieve less than 200C within 2 minutes at sentinel outlets Store hot water >=600C Temperatures to be achieved: Cold Water and storage and supply Storage should be less than 20 dgrees C Outlets should be less than 20 dgrees C Hot Water storage and supply Storage should be greater than 60 degrees C Supply to outlets & distribution should be greater than 50 degrees C NB vent pipe from calorifier should ideally not discharge into cold water tank. If it does systems to identify any discharge should be considered. Easier to carry out remedial action to discharge to a safer point. Case Scalding of baby following discharge from vent pipe into plastic cold water store. Return water >=500C distribute hot water at >=500C

The incoming and storage temperature of the cold water <200C. COLD WATER TANK The incoming and storage temperature of the cold water <200C. The tank should be: - sized to supply one day’s water usage; -should be sited in a cool place; -should be thermally insulated to protect from extremes of heat; and -should possess a tight fitting lid and a vent. The water over flow pipe and vent should be fitted with an insect screen; The water surface should be clean and free of any debris or contamination; over flow

The hot water cylinder should: - be sized to provide water needed for a day’s usage; be insulated; deliver outgoing water at a temperature of at least 600C and return water of at least 500C -be fitted with a drain valve The vent pipe should preferably not drain to the cold water tank. Large cylinders should be fitted with a shunt pump to mix the water and heat the whole volume to at least 600C for at least one hour each day

Water distribution : Hot water should reach at least 500C within 1 minute of running outlet; Cold water should be less than 200C within 2 minutes of running outlet; Temperatures should be measured monthly at the sentinel outlets (where TMVs are fitted the temperature of the pipe work at the inlet to the TMVs should be measured eg using a surface probe thermometer)