CMS plans for Endcap Calorimetry at HL-LHC

Slides:



Advertisements
Similar presentations
Recent news about SiPM based applications R&D in DESY Nicola D’Ascenzo University of Hamburg - DESY.
Advertisements

Roger Rusack – The University of Minnesota
DREAM Collaboration: Recent Results on Dual Readout Calorimetry. F.Lacava for the DREAM Collaboration Cagliari – Cosenza – Iowa State – Pavia – Pisa –
Jin Huang Los Alamos National Lab.  Cited from March collaboration Meeting EC group Internal Communication Jin Huang 2 Preshower ID power drop significantly.
CMS Phase 2 Upgrade: Scope and R&D goals CMS Phase 2 Upgrade: Scope and R&D goals October 21, 2014 Jeremiah Mans On behalf of the CMS Collaboration.
1 Study of the Tail Catcher Muon Tracker (TCMT) Scintillator Strips and Leakage with Simulated Coil Rick Salcido Northern Illinois University For CALICE.
Testbeam Requirements for LC Calorimetry S. R. Magill for the Calorimetry Working Group Physics/Detector Goals for LC Calorimetry E-flow implications for.
E.Kistenev History lessons Specification Primary options e-RHIC meeting at BNL, Sept 19th, 2002 Hermetic Calorimeter for e-RHIC collider experiments.
NIU Workshop R. Frey1 Reconstruction Issues for Silicon/Tungsten ECal R. Frey U. Oregon NIU Workshop, Nov 8, 2002.
General Trigger Philosophy The definition of ROI’s is what allows, by transferring a moderate amount of information, to concentrate on improvements in.
Application of Neural Networks for Energy Reconstruction J. Damgov and L. Litov University of Sofia.
Calorimeters A User’s Guide Elizabeth Dusinberre, Matthew Norman, Sean Simon October 28, 2006.
1 Tianchi Zhao University of Washington Concept of an Active Absorber Calorimeter A Summary of LCRD 2006 Proposal A Calorimeter Based on Scintillator and.
The CMS Upgrade Program ECFA High Luminosity LHC Experiments Workshop Aix-les-Bains, October 1, 2013 J. Spalding, on behalf of the CMS Collaboration 1.
Heavy Scitillating Crystals and Glasses for a Combined EM and HCal at ILC Tianchi Zhao University of Washigton Sept. 25, 2007.
Shashlik type calorimeter for SHIP experiment
PANDA electromagnetic calorimeters Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group INSTR08 28 Feb - 05 Mar 2008.
Roger Rusack – The University of Minnesota 1.
J-C BRIENT Prague Performances studies of the calorimeter/muon det. e + e –  W + W – at  s=800 GeV Simulation SLAC-Gismo Simulation MOKKA-GEANT4.
Jan MDI WS SLAC Electron Detection in the Very Forward Region V. Drugakov, W. Lohmann Motivation Talk given by Philip Detection of Electrons and.
Light Calibration System (LCS) Temperature & Voltage Dependence Option 2: Optical system Option 2: LED driver Calibration of the Hadronic Calorimeter Prototype.
The CMS Electromagnetic Calorimeter Roger Rusack The University of Minnesota On behalf of the CMS ECAL collaboration.
CMS ECAL performance and upgrade Anton Karneyeu (INR, Moscow) CMS Collaboration INSTR14, Novosibirsk, Russia, 27 February 2014.
Pion Showers in Highly Granular Calorimeters Jaroslav Cvach on behalf of the CALICE Collaboration Institute of Physics of the ASCR, Na Slovance 2, CZ -
CMS ECAL Laser Monitoring System Christopher S. Rogan, California Institute of Technology, on behalf of the CMS ECAL Group High-resolution, high-granularity.
The CMS detector as compared to ATLAS CMS Detector Description –Inner detector and comparison with ATLAS –EM detector and comparison with ATLAS –Calorimetric.
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
R&D status of the Scintillator- strip based ECAL for the ILD Oct LCWS14 Belgrade Satoru Uozumi (KNU) For the CALICE collaboration Scintillator strips.
ECAL PID1 Particle identification in ECAL Yuri Kharlov, Alexander Artamonov IHEP, Protvino CBM collaboration meeting
Results from particle beam tests of the ATLAS liquid argon endcap calorimeters Beam test setup Signal reconstruction Response to electrons  Electromagnetic.
Mechanics and granularity considerations of a Tile hadronic calorimeter for FCC hh barrel Nikolay Topilin/Dubna+ Sergey Kolesnikov/Dubna Ana Henriques/CERN.
LHC The Large Hadron Collider (LHC) is an accelerator with 27 km circumference. Being built on the France- Switzerland border west of Geneva. It will start.
ILC Calorimetry Test Beam Status Lei Xia ANL HEP.
18-23 July 2006J. Hauptman Vancouver LCW06 4th Calorimeter Plans (or dual readout is wonderful, but what are its problems) 1. Electrons and photons limited.
V. Korbel, DESY1 Progress Report on the TESLA Tile HCAL Option To be filled soon.
HIGH GRANULARITY CALORIMETER ANALYSIS SARAH MARIE BRUNO CMS - CALTECH GROUP SUPERVISORS: ADOLF BORNHEIM, LINDSEY GRAY, MARIA SPIROPULU.
5-9 June 2006Erika Garutti - CALOR CALICE scintillator HCAL commissioning experience and test beam program Erika Garutti On behalf of the CALICE.
The LHCb Electromagnetic Calorimeter Ivan Belyaev, ITEP/Moscow.
1 1 - To test the performance 2 - To optimise the detector 3 – To use the relevant variable Software and jet energy measurement On the importance to understand.
1 Towards Phase 2 TP releases 2013 Didier Contardo, Jeff Spalding Status of current simulations studies and ongoing issues Needs for TP preparation.
1 Plannar Active Absorber Calorimeter Adam Para, Niki Saoulidou, Hans Wenzel, Shin-Shan Yu Fermialb Tianchi Zhao University of Washington ACFA Meeting.
The ATLAS Tile hadron calorimeter The ATLAS Tile hadron calorimeter Ana Henriques/CERN on behalf of the ATLAS collaboration ANIMMA 2015, April Content:
PbWO 4 crystals Calorimeter Liping Gan University of North Carolina Wilmington.
Simulation studies of total absorption calorimeter Development of heavy crystals for scintillation and cherenkov readout Dual readout in the 4 th concept.
Roger Rusack – The University of Minnesota Upgrades to the CMS detector.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
Ilhan TAPAN* and Fatma KOCAK
Lecture 8 – Detectors - II
The Electromagnetic Calorimetry of the PANDA Detector at FAIR
IOP HEPP Conference Upgrading the CMS Tracker for SLHC Mark Pesaresi Imperial College, London.
CEPC 数字强子量能器读出电子学预研进展
Calorimeters at CBM A. Ivashkin INR, Moscow.
SiD Calorimeter R&D Collaboration
CALICE scintillator HCAL
superB Detector Workshop I University of Perugia and INFN
The Upgrade of CMS for High Lumi LHC
CMS High Granularity Calorimeter (HGCAL) Beam H2 2017
Calorimetry for a CLIC experiment
CMS ECAL Calibration and Test Beam Results
Alternative CEPC Calorimeter
Scintillator HCAL: LOI issues
Simulation study for Forward Calorimeter in LHC-ALICE experiment
Rick Salcido Northern Illinois University For CALICE Collaboration
Calorimeter Backgrounds
Calorimeter technology
The LHCb Level 1 trigger LHC Symposium, October 27, 2001
Dual readout calorimeter for CepC
Michele Faucci Giannelli
Steve Magill Steve Kuhlmann ANL/SLAC Motivation
LC Calorimeter Testbeam Requirements
Presentation transcript:

CMS plans for Endcap Calorimetry at HL-LHC Motivations for change and requirements Proposals under consideration Shashlik and HE rebuild High Granularity Calorimeter Conclusions

Present CMS Endcap HE Brass Scintillator EE PWO ES preshower

Radiation damage on crystals Gamma irradiation creates color centers which reduce the crystal transparency up to a saturation level, which depends on the dose rate. The damage is spontaneously recovered at room temperature. Hadron damage creates clusters of defects which cause light transmission loss. The damage is permanent and cumulative at room temperature.

Expected Light loss in Endcaps (EE) Simulation 50 GeV e- Fraction of ECAL response In addition, longitudinal non-uniformity builds up and creates a constant term. The EE crystals were chosen to survive the nominal LHC 500 fb-1 , with the precision region up to h < ~ 2.5

Radiation damage End Cap Hadronic Calorimeter Radiation damage is enhanced by low dose rate. Extrapolations show that after 500 fb-1, the high h corner (first layers) will have <5% signal left. Need to replace ~ 20% of the current Sci. tiles

This calls for high granularity & short Moliere radius Pileup Pileup will dramatically increase from <20-30> today to an average of <140> simultaneous interactions (in-time pileup) , or more if performance allows both in-time and out of time (previous/following bunches) increase of occupancy and “background” under physical objects (jets, electrons, photons) This calls for high granularity & short Moliere radius Electronics will have to be replaced anyhow, to allow for longer Trigger latency (-> ≥10 ms) and higher L1 trigger rate.

Physics (examples) VBF Htt HHbbtt or bbgg WLWL scattering (low pT) Forward jet tagging Hadronic tau reconstruction Electron / muon id Missing ET Low PT threshold VBF Htt HHbbtt or bbgg Wants good em resolution WLWL scattering (low pT) CMS needs to replace the Endcap electromagnetic calorimeter and replace/improve the hadron calorimeter due to radiation damage. If anything, the HL-LHC physics is as demanding in the high h region and at low pt than for LHC. Maintain or improve the current performance in a much harsher environment

Calendar Review March 2014: aim is to reduce the three options to two, to focus effort and R&D resources Technical Proposal September 2014 with the two remaining options Selection of single option by ~ April 2015 TDR first half of 2017 Installation 2023-2024. LS3 shut down is planned to be 36 months, a lot of work on the Barrel (New Tracker, new ECAL FE electronics etc..), so one endcap of new EE+HE should be ready to install ~ at the start of the shutdown, the second whenever convenient.

3 proposals internally reviewed in March 2014 Shashlik with crystal as active medium + HE-rebuilt : device with very good em resolution, with higher granularity and rad hardness than present EE, followed by a rebuilt HE using the same concept as now with enhanced rad hardness and segmentation. Combined Forward Calorimeter (CFC) Unique device with best hadron energy resolution, based on the dual readout DREAM/RD52 concept. Brass absorber with fibres (Č or Sci) every 2mm. Longitudinal segmentation by timing. Electron id by lateral shower shape and timing. High Granularity Calorimeter (HGCAL) Silicon-based device “a la CALICE” with “extreme” granularity both transverse O(cm2) and longitudinal (read independently every layer). Em and Had sections (total ~ 5l) followed by a tail catcher Decision was to de-select CFC Although none of the concepts is yet mature and has proven to give best performance in the CMS environment: estimated to present more risk to demonstrate performance and feasibility on expected time scale.

Reminder on radiation environment hadronic em Shower max at h=3 : 1016 n/cm2 150 Mrad Behind em section : 1015 n/cm2 ~10 Mrad Behind had section : 1012 n/cm2 ~10 krad (recessed photosensors + electronics) 3000 fb-1

Shashlik Module Materials: Absorber: W Active Material: LYSO(Ce) (primary) Active material: CeF3 also under study\ Structure: 2.5 mm W plates (28 per module) 1.5 mm LYSO(Ce) plates (29 per module) Module Dimensions: Transverse Size: Front Face 14 x 14 mm2  Length 114 mm Readout: WLS Capillaries (4 per module) Calibration Fiber (1 per module) 3x3 mm2 GaInP Photosensors 4 per module or SiPM in recessed position Segmentation in depth: Unsegmented except for the proposed extraction of a signal near shower max

Parametric Comparison W/LYSO Shashlik and PbWO4 EE W/LYSO(Ce) PbWO4 Length (mm) 114 220 Transverse size (mm) 14 28.6 # modules for 2 endcaps 61,000 14,648 Average Moliere Radius (mm) 13.7 21 Average Radiation Length Xo (mm) 5.1 8.9 Light Yield (relative to NaI) 85 0.3 Emission Wavelength 420 425 Decay time (ns) 40 25 Light Output (p.e./MeV) depending on QE 8-10 2 Temp Dependence (%/C) -0.2 -2.2

Shashlik Main Challenges 1) Confirm crystal rad. hardness 2) Develop rad-hard WLS capillary 3) GaInP photosensors 4) Confirm performance in CMS environment (pileup…) η = 3.0 at 3000 fb-1 expected e/γ resolution ∼ 10%/√E + 1%

EE Shashlik beam tests 500 MeV electrons 120 GeV protons First test of a 4x4 modules prototype 364 LYSO crystals (final configuration) WLS readout at both ends with SiPMs Laser calibration in central fiber First test of a CeF3 modules 10 x (3.1 mm W + 10 mm CeF3) Scintillating fibers readout with PMTs 120 GeV protons 500 MeV electrons 1 e 2 e Downstream and upstream signals Analysis of data in progress Raw signal (left) and correlation (right) Analysis of data in progress

HE re-build HE re-build Current New HE re-build Higher granularity in (η/φ) x 2 & longitudinal & extension towards EE Shashlik (resolution) Scintillating tiles in brass with finger WLS to reduce light path (80%) Investigating new plastic and liquid scintillators or radiation tolerant scintillating fibers quartz/glass/crystals doped with Ce3 for innermost region

High Granularity Calorimeter (HGCAL) Fine depth segmentation ECAL: ~33 cm, 25 X0, 1, 31 layers: 11 planes of Si separated by 0.5 X0 of lead/Cu 10 planes of Si separated by 0.8 X0 of lead/Cu 10 planes of Si separated by 1.2 X0 of lead/Cu HCAL: ~66 cm, 4λ: 12 planes of Si separated by 40 mm of brass Fine grain pads 0.9 cm2 to 1.8 cm2 3.7/1.4 Mch & 420/250 m2 Si in E/H 30000 modules Back HCAL as HE re-build 5λ With increased transverse granularity

High Granularity Calorimeter (HGCAL) 3D measurement of the shower topology 25 mm Moliere radius (shower narrower before max) Expected e/γ resolution ∼ 20%/√E + ≤ 1% Tiling of 8” hexagonal Si-sensors modules VBF Jet no PU

Challenges for HGCAL Verify radiation hardness of Silicon sensors. Similar fluence as innermost pixel but: Tracker dominated by charged hadrons -> extend studies to neutrons Verify if p-on-n suitable (the less expensive option) Prototype partial implant (100m or 200 m on 300m wafer) for high h region

Challenges for HGCAL(2) 2) Engineering studies module design and thermal properties keeping longitudinal compactness thermal screen and exit of services through cold/warm transition 3) Readout and Trigger definition FE electronics characteristics dynamic range optimisation in noise/power/peaking-time Energy threshold vs occupancy & mip visibility Powering Data flow and data concentration Trigger primitive … 4) Demonstrate benefit of high granularity in physics performance

Conclusions CMS needs to change its Endcap Calorimeters for the HL-LHC phase Two concepts are being currently proposed: Shashlik with HE rebuild more in the line of the existing CMS challenges are mostly in establishing the radiation hardness of the proposed components High Granularity Calorimeter “a la CALICE” but the LHC environment is very different from ILC: radiation (-> low T), continuous powering, high rate challenges are mostly in finding proper engineering solutions In both cases, performance assessment in the CMS environment is going-on in view of the Technical Proposal. Decision between the two solutions expected in ~ 1 year.