Graeme Stewarta, R. Batesa, G. Pellegrinib, G. Krambergerc, M

Slides:



Advertisements
Similar presentations
Trapping in silicon detectors G. Kramberger Jožef Stefan Institute, Ljubljana Slovenia G. Kramberger, Trapping in silicon detectors, Aug , 2006,
Advertisements

Characterization of 150  m thick epitaxial silicon pad detectors from different producers after 24 GeV/c proton irradiation Herbert Hoedlmoser (1), Michael.
TCT+, eTCT and I-DLTS measurement setups at the CERN SSD Lab
On MCz SCSI after 24 GeV/c proton irradiation 12th RD50 Workshop Ljubljana, 2-4 June 2008 D. Creanza On behalf of the Bari and Pisa RD50 groups.
Semiconductor detectors
Charge collection studies on heavily diodes from RD50 multiplication run G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
Techniques for determination of deep level trap parameters in irradiated silicon detectors AUTHOR: Irena Dolenc ADVISOR: prof. dr. Vladimir Cindro.
Charge collection studies on heavily diodes from RD50 multiplication run (update) G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
11 th RD50 Workshop, CERN Nov Results with thin and standard p-type detectors after heavy neutron irradiation G. Casse.
KIT – University of the State of Baden-Wuerttemberg and National Research Center of the Helmholtz Association Institut für Experimentelle Kernphysik
Sally Seidel 1 3D Sensor Studies at New Mexico Sally Seidel for Martin Hoeferkamp, Igor Gorelov, Elena Vataga, and Jessica Metcalfe University of New Mexico.
ALBA Synchrotron – 17 June 2010 Centro Nacional de MicroelectrónicaInstituto de Microelectrónica de Barcelona First Measurements on 3D Strips Detectors.
Edge-TCT and Alibava measurements with pion and neutron irradiated micro-strip detectors V. Cindro 1, G. Kramberger 1, I. Mandić 1, M. Mikuž 1,2, M. Milovanović.
Hamburg University: Plans for SLHC Silicon Detector R&D Georg Steinbrück Wien Feb 20, 2008.
RD50 RD50 workshop FreiburgKatharina Kaska 1 Determination of depletion voltage from CV, IV and CCE measurements on Pad Detectors Katharina Kaska, Michael.
1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.
RD50 participation in HV-CMOS submissions G. Casse University of Liverpool V. Fadeyev Santa Cruz Institute for Particle Physics Santa Cruz, USA HV-CMOS.
Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN
Evaluation of electron and hole detrapping in irradiated silicon sensors Markus Gabrysch 1, Mara Bruzzi 2, Michael Moll 1, Nicola Pacifico 3, Irena Dolenc.
Charge Collection Study of Heavily Irradiated Silicon Microstrip Detectors Chris Lucas (University of Bristol) Irena Dolenc Kittelmann, Michael Moll, Nicola.
8 July 1999A. Peisert, N. Zamiatin1 Silicon Detectors Status Anna Peisert, Cern Nikolai Zamiatin, JINR Plan Design R&D results Specifications Status of.
Analysis of Edge and Surface TCTs for Irradiated 3D Silicon Strip Detectors Graeme Stewart a, R. Bates a, C. Corral b, M. Fantoba b, G. Kramberger c, G.
Effects of long term annealing in p-type strip detectors irradiated with neutrons to Φ eq =1·10 16 cm -2, investigated by Edge-TCT V. Cindro 1, G. Kramberger.
1 Nicolo Cartiglia, INFN, Torino - RD50 - Santander, 2015 Timing performance of LGAD-UFSD 1.New results from the last CNM LGAD runs 2.A proposal for LGAD.
Charge Collection and Trapping in Epitaxial Silicon Detectors after Neutron-Irradiation Thomas Pöhlsen, Julian Becker, Eckhart Fretwurst, Robert Klanner,
G. Kramberger, Charge collection properties of heavily irradiated expitaxial silicon detectors, RESMDD04, Oct , 2004, Firenze Setup and samples Setup.
1/14 Characterization of P-type Silicon Detectors Irradiated with Neutrons M.Miñano 1, J.P.Balbuena 2, C. García 1, S.González 1, C.Lacasta 1, V.Lacuesta.
Inversion Study on MCz-n and MCz-p silicon PAD detectors irradiated with 24 GeV/c protons Nicola Pacifico Excerpt from the MSc thesis Tutors: Prof. Mauro.
TCT measurements with SCP slim edge strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko.
Edge-TCT studies of heavily irradiated strip detectors V. Cindro 1, G. Kramberger 1, A. Macchiolo 3, I. Mandić 1, M. Mikuž 1,2, M. Milovanović 1, P. Weigell.
Celso Figueiredo26/10/2015 Characterization and optimization of silicon sensors for intense radiation fields Traineeship project within the PH-DT-DD section.
A CCE and TCT Study on low resistivity MCz p-on-n detectors Nicola Pacifico, Michael Moll, Manuel Fahrer 16 th RD50 workshop, Barcellona, 31 May-2 June.
CNM double-sided 3D strip detectors before and after neutron irradiation Celeste Fleta, Richard Bates, Chris Parkes, David Pennicard, Lars Eklund (University.
Study on and 150  m thick p-type Epitaxial silicon pad detectors irradiated with protons and neutrons Eduardo del Castillo Sanchez, Manuel Fahrer,
Charge Multiplication Properties in Highly Irradiated Thin Epitaxial Silicon Diodes Jörn Lange, Julian Becker, Eckhart Fretwurst, Robert Klanner, Gunnar.
RD50 RD50 Workhop: CERN Katharina Kaska Epitaxial silicon detectors irradiated with protons and neutrons Katharina Kaska, Michael Moll RD50 Workshop.
Giulio Pellegrini 27th RD50 Workshop (CERN) 2-4 December 2015 Centro Nacional de MicroelectrónicaInstituto de Microelectrónica de Barcelona 1 Status of.
Simulation of new P-Type strip detectors 17th RD50 Workshop, CERN, Geneva 1/15 Centro Nacional de MicroelectrónicaInstituto de Microelectrónica de Barcelona.
Infrared Laser Test System Silicon Diode Testing 29 May 2007 Fadmar Osmić Contents: Setup modifications new amplifier (Agilent MSA-0886) new pulse generator.
TCT measurements with irradiated strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko Mikuž.
Trench detectors for enhanced charge multiplication G. Casse, D. Forshaw, M. Lozano, G. Pellegrini G. Casse, 7th Trento Meeting - 29/02 Ljubljana1.
Giulio Pellegrini Actividades 3D G. Pellegrini, C. Fleta, D. Quirion, JP Balbuena, D. Bassignana.
ADC values Number of hits Silicon detectors1196  6.2 × 6.2 cm  4.2 × 6.2 cm  2.2 × 6.2 cm 2 52 sectors/modules896 ladders~100 r/o channels1.835.
Investigation of electric field and evidence of charge multiplication by Edge-TCT G.Kramberger, V. Cindro, I. Mandić, M. Mikuž, M. Milovanović, M. Zavrtanik.
TCT measurements with strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko Mikuž 1,2, Marko.
Zheng Li, 96th LHCC open session, 19th November 2008, CERN RD39 Status Report 2008 Zheng Li and Jaakko Härkönen Full author list available at
June T-CAD Simulations of 3D Microstrip detectors a) Richard Bates b) J.P. Balbuena,C. Fleta, G. Pellegrini, M. Lozano c) U. Parzefall, M. Kohler,
E-TCT measurements with laser beam directed parallel to strips Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Mikuž 1,2,
TCT measurements of HV-CMOS test structures irradiated with neutrons I. Mandić 1, G. Kramberger 1, V. Cindro 1, A. Gorišek 1, B. Hiti 1, M. Mikuž 1,2,
Giulio Pellegrini 12th RD50 - Workshop on Radiation hard semiconductor devices for very high luminosity colliders, Ljubljana, Slovenia, 2-4 June 2008 Report.
3D Simulation Studies of Irradiated BNL One-Sided Dual-column 3D Silicon Detector up to 1x1016 neq/cm2 Zheng Li1 and Tanja Palviainen2 1Brookhaven National.
Radiation damage studies in LGAD detectors from recent CNM and FBK run
Practical advices for using TCT (mostly for Particulars setups)
Radiation Damage TCAD Analysis of Low Gain Avalanche Detectors
Characterization and modelling of signal dynamics in 3D-DDTC detectors
G. Kramberger, V. Cindro, I. Mandić,
First production of Ultra-Fast Silicon Detectors at FBK
Charge collection studies with irradiated CMOS detectors
Radiation Damage TCAD Analysis of Low Gain Avalanche Detectors
Irradiation and annealing study of 3D p-type strip detectors
Position Sensitive TCT Measurements with 3D-stc detectors
Study of radiation damage induced by 26MeV protons and reactor neutrons on heavily irradiated MCz, FZ and Epi silicon detectors N. Manna Dipartimento.
AMS-Chess1 Characterization
Igor Mandić1, Vladimir Cindro1, Gregor Kramberger1 and Marko Mikuž1,2
Radiation Damage in Silicon
Vladimir Cindro, RD50 Workshop, Prague, June 26-28, 2006
CCE measurements with Epi-Si detectors
Peter Kodyš, Zdeněk Doležal, Jan Brož,
Beam Test Results for the CMS Forward Pixel Detector
Igor Mandić1, Vladimir Cindro1, Gregor Kramberger1 and Marko Mikuž1,2
Presentation transcript:

Preliminary Analysis of Edge and Top TCTs for Irradiated 3D Silicon Strip Detectors Graeme Stewarta, R. Batesa, G. Pellegrinib, G. Krambergerc, M. Milovanovicc a: University of Glasgow, School of Physics and Astronomy, Kelvin Building, University Avenue, Glasgow, G12 8QQ b: Centro Nacional de Microelectrónica, Campus Universidad Autónoma de Barcelona, Spain c: J. Stefan Institute, Jamova cesta 39, 1000 Ljubljana, Slovenia

Contents Introduction TCT Results Conclusions 3D Detectors TCT Measurements TCT Results Non-Irradiated Top and Edge TCTs Irradiated Top TCTs Annealing Effects Conclusions

Introduction Radiation hard 3D detectors are a candidate for LHC upgrades. Transient Current Techniques (TCTs) provide a method for investigating electric fields in silicon detectors. In a TCT measurement, a short laser pulse is shone in a particular line through the detector. Charge and current data is collected giving new information on the operation of 3D devices. This can be repeated at many points across a detector’s surface to map the electric field.

3D Detector Design Columns etched from opposite sides of substrate and don't pass through full thickness All fabrication done at CNM Distance between columns is 80 μm, with a 25 μm wide Aluminium strip connecting n-type columns. Substrate is 285 μm thick. 11 strips were bonded up but with readout only from the central strip. IR Photon 4 4

TCT setup The system is set in dry air atmosphere! Cooling to ~-20oC Peltier controller The system is set in dry air atmosphere! Cooling to ~-20oC y table Cooled support Cu block Detector The whole system is completely computer controlled! 100 ps pulse 200 Hz repetition l=1064 nm cooling pipes x table z table 1 GHz oscilloscope detector HV Bias T Laser 2 fast current amplifiers (2.5 GHz) Laser driver trigger line G. Kramberger – 15th RD50 Meeting, 2009

Top and Edge TCTs Advantages of TCTs: FWHM ~8 μm Top TCT λ = 1064nm Edge TCT Advantages of TCTs: Position of e-h generation can be controlled by moving tables The amount of injected e-h pairs can be controlled by tuning the laser power Easier mounting and handling Not only charge but also induced current is measured – a lot more information is obtained

Top and Edge TCTs Drawbacks of TCTs: FWHM ~8 μm Top TCT λ = 1064nm Edge TCT Drawbacks of TCTs: Applicable only for strip/pixel detectors if 1064 nm laser is used (light must penetrate guard ring region) Only the position perpendicular to strips can be used due to widening of the beam! Beam is “tuned” for a particular strip Light injection side has to be polished to have a good focus – depth resolution It is not possible to study charge sharing due to illumination of all strips

Example Waveform Rise time of fastest peak can give velocity profile Reflection Integration of peaks gives charge collected Faster electron peak Slower hole peak

Non-Irradiated Top TCT Readout n-type Electrodes Non-readout n-type Electrodes p-type Electrodes Unit Cell Laser scans across surface Map is charge collected in 20 ns after laser pulse.

Non-Irradiated Top TCT 20V Add columns and less waveforms 20V

Non-Irradiated Top TCT 0V 3V 6V 9V 12V 15V Inter-column depletion at ~2V Full, under-column depletion at 40V

Non-Irradiated Edge TCT Laser scans across edge N-type Electrodes Waveforms collected at 20V P-type Electrodes

Non-Irradiated Edge TCT 0V 1V 2V 3V 4V 5V Full depletion of inter-column region by 3V Depletion of the region beneath the electron collecting n-type columns beginning by 4V P-type columns not fully depleted by 6V 6V 20V

Irradiation and Annealing Sample irradiated in Ljubljana facilities. Irradiation fluence was 5x1015 1MeV Nequ cm-2. Sample always annealed in the setup with the Peltier element constant laboratory temperature: 21 oC stable position/laser sample temperature stabilized to less than 1°C Annealing at 60°C for a cumulative time of 600 minutes. After each annealing step, voltage scans from 0V up to 400V were performed

Irradiated Top TCT 400V 60V 200V 200V Add in columns Waveforms from the region between n-type columns show a double peak for electron and hole collection and a postive electron signal past 40 μm Waveforms from the region across the p-type column show the same peaks without the bipolar signal

Annealing Effects End of beneficial annealing at around 80 mins. After type inversion we have a longer term reverse annealing Significant annealing beyond beneficial annealing leads to a decrease in the interstrip resistance. Eventually, the strips short together. Resistance vs Annealing time, shown by C. Fleta at 15 RD50, June 2010.

Annealing Effects – 20 mins 0V - 400V in steps of 50V 0V 50V 100V 150V 200V 250V 300V 350V 400V

Annealing Effects – 40 mins 0V - 400V in steps of 50V 0V 50V 100V 150V 200V 250V 300V 350V 400V

Annealing Effects – 100 mins 0V - 400V in steps of 50V 0V 50V 100V 150V 200V 250V 300V 350V 400V

Annealing Effects – 300 mins 0V - 400V in steps of 50V 0V 50V 100V 150V 200V 250V 300V 350V 400V

Annealing Effects – 600 mins 100V - 300V in steps of 100V 100V 200V 300V

Conclusions Future Analysis: Edge and top TCTs provide a new method to probe 3D devices. Substantial depletion occurs at very low voltages. Irradiation and subsequent annealing alters the collection of electrons and holes. Future Analysis: Compare the velocity profiles of non-irradiated and irradiated detectors. From the velocity profiles, electric field can be derived. Edge TCTs of an irradiated sample, before and after annealing.