Corneal Pachymetry in Prediction of Refraction After Cataract Surgery

Slides:



Advertisements
Similar presentations
Accuracy of Predicted Refractive Error in Resident-Performed Cataract Surgery Using Partial Coherence Interferometry Nickolas P. Katsoulakis, M.D., Paul.
Advertisements

A simple and accurate method of alignment for toric intraocular lens implantation using anterior segment optical coherence tomography (OCT). Kazuno Negishi,
Yüksel Totan, Ramazan Yaĝcı, Zeynel Arslanyılmaz, Uĝurcan Keskin The authors have no financial interest.
Eltutar, Kadir; Akcetin, Tulay A.; Ozcelik, N. Demet Istanbul Education and Research Hospital Department of Ophthalmology The authors state that they have.
INTRA-OCULAR LENS POWER CALCULATION IN POST- REFRACTIVE SURGERY ASIAN EYES USING THE HAIGIS-L FORMULA Dr Daphne Han, FRCS Dr Wei-Han Chua, FRCS Dr Peter.
IOL power calculation after refractive surgery A. Peyman, MD.
Personalised eye modelling for customised intraocular lens designs Matthew Sheehan, Eamonn O’Donoghue, Conor Sheil and Alexander Goncharov Photonics Ireland,
Placement of Toric Intraocular Lens and the Long-term Change in the Axis of Corneal Astigmatism after Sutureless Cataract Extraction by Phacoemulsification.
JAIRO E. HOYOS, MD MELANIA CIGALES, MD Instituto Oftalmológico Hoyos Barcelona - SPAIN.
G. Jacob 1,2, C. Bouchard 2, S. Kancherla 1. Edward Hines, Jr. VA Hospital, Hines, IL, Department of Ophthalmology 1. Loyola University Medical Center,
The Second Report of The National cataract Surgery Registry PATIENTS’ CHARACTERISTICS Table 1.1: Age Distributions.
Phacoemulsification in eyes with previous anterior chamber phakic IOL surgery Walton Nosé, MD, PhD 1,2 Adriana dos Santos Forseto, MD 1 Mariana Ávila,
Hong Kong Eye Hospital Ms Frenchy Chiu Dr Victoria Wong IOL master
Biometric Accuracy in High Hypermetropes and Myopes
INTRAOCULAR LENS POWER CALCULATION BY IMMERSION A-SCAN BIOMETRY VERSUS CONTACT A-SCAN BIOMETRY MEASUREMENTS BEFORE CATARACT SURGERY Burak Bilgin**, M.D.,
Astigmatism management with toric intraocular lenses in cataract patients Adriano Guarnieri 1-2, Luis W. Lu 3-4, Alfonso Arias- Puente INCIVI, Madrid,
Sonia Yoo, MD 1 Fernanda Piccoli, MD 1 Artur Schmitt, MD 1 Takeshi Ide, MD 1 Tsontcho Ianchulev, MD 2 Authors have no financial interest in this subject.
Khairidzan Mohd Kamal MD
EVALUATION OF REFRACTIVE OUTCOMES AFTER IOL IMPLANTATION
Endothelial Keratoplasty in Patients With an Anterior Chamber Intraocular Lens: A Montreal Experience Georges M. Durr, MD 1,2 Johanna Choremis, MD, FRCSC.
Comparison of Central Corneal Thickness and Peripheral Corneal Thickness using Sheimpflug system, Optical Coherence Tomography and Ultrasound Pachymetry.
Prospective, Randomized, Double-Blind Study Comparing Nepafenac 0.1% (Nevanac™) and Bromfenac Sodium 0.09% (Xibrom™) in Post-Op Cataract Patients Hon-Vu.
Mean Keratometry Measurement Post Penetrating Keratoplasty Jacky Yeung MSc MD, Stephanie Baxter MD FRCS(C) Department of Ophthalmology, Hotel Dieu Hospital,
Partial Coherence Interferometry Failure Rate in a Teaching Hospital Leslie A. Wei 1,2, BA, Nickolaus P. Katsoulakis 2, MD, Theodoros Filippopoulos 3,
Combined cataract surgery and endoscopic cyclophotocoagulation in patients with glaucoma without prior incisional glaucoma surgery Matthew P. Traynor,
Adriana S. Forseto1, MD Walton Nosé1,2, MD
Outcome of cataract surgery in Scleritis patients Bhupesh Bagga Cornea & Anterior Segment Department L.V.Prasad Eye Institute, Hyderabad,India Financial.
Sherman W. Reeves, MD, MPH 1,3,4 ; Jacob A. Kozisek, OD 1,2 ; Noumia Cloutier-Gill, OD 1,2 ; David R. Hardten, MD 1,2,3,4 Accuracy of Scheimpflug Imaging.
Comparison of Central Corneal Thickness, Anterior Chamber Depth, and Central Corneal Power Measurements between Two Scheimpflug Imaging Systems Yuichi.
Post-LASIK Intraocular Lens Power Adjustment Nomogram Joseph Diehl Kevin Miller, MD Jules Stein Eye Institute, David Geffen School of Medicine.
Comparison of visual function following piggyback implantation of Acrysof ReSTOR intraocular lenses with Tecnis multifocal ZM900 intraocular lenses. Rodrigo.
Minimizing Risk in Visian ICL Implantation.
COMPARISON AND EVALUATION OF OCULAR BIOMETRY USING A NEW NON-CONTACT OPTICAL LOW COHERENCE REFLECTOMETER David Goldblum 1,3, Kaspar Rohrer 1, Rudolf Waelti.
Simulated Experiments on IOL Power Calculation Using Anterior Segment OCT Dong Hyun Jo, M.D., 1,2 Mee Kum Kim, M.D., 1,2 Won Ryang Wee, M.D. 1,2 1 Department.
Liquifaction Method and Extent of Posterior Capsule Opacification: Two-Year Follow-up Marie Kalfertova, Mariya Burova, Pavel Rozsival, Nada Jiraskova Nada.
John P Berdahl M.D.* David R. Hardten M.D., F.A.C.S.* *No relevant financial disclosures.
Poster# P36 Comparison of Techniques of Measuring Anterior Chamber Depth and Corneal Curvature in Indian Eyes Sujata Das, MS, FRCS Anjula Kumari, B.Optom.
Corneal CXL in Pediatric Patients with Progressive Keratoconus Stephanie Wise, Christian Diaz, Karolien Termote, Paul J. Dubord, Martin McCarthy, Sonia.
Intraocular Lens Outcomes: Comparison of Technologies and Formulas Carolina Eyecare Physicians, LLC Research Assistant Professor of Ophthalmology Storm.
Changes of Axial Length After LASIK Surgery: A 3-Year Follow-Up Study
Marilyn Watkins-Ramdin, COMT ROUB
Nagasaki University, Nagasaki, Japan
Comparison of Endothelial Cell Loss After Phacoemulsification Performed by Third Year Residents and Anterior Segment Surgeons Alexandra Braunstein, MD.
Late In-the-bag Intraocular Lens Dislocation:
Premium IOL May be one way to achieve the visual goals of selected patients I describe some pearls for premium IOL implantation to help ensure that we.
Hayashi Eye Hospital, Fukuoka, Japan
World Cornea Congress VI April 7-9, 2010
Blood Reflux In Schlemm’s Canal Of Normal Cataract Patients: Simple Way To Identify The Trabecular Meshwork With Healthy Collector Channel Masahiro Maeda1,
Refractive outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens power calculation Zina Zhang MD1, Logan.
Aug 11, 2017 Comparison of predictive accuracy on Partial coherence interferometry (PCI) and swpt-source optical coherence tomographry (SS-OCT) Choun-Ki.
Effect of Axial Length Measurement Method on Refractive Outcomes of Cataract Surgery: Real World Comparison of Partial Coherence Interferometry and Immersion.
Nienke Visser, Tos T.J.M. Berendschot, Rudy M.M.A. Nuijts
MP Weikert, M Shirayama, L Wang, DD Koch
Early Experience with Descemet’s Stripping Automated Endothelial Keratoplasty Combined with Phacoemulsification: Clinical and Refractive Outcome University.
Comparison in Reduction of Preoperative Astigmatism after Cataract Surgery with Toric IOLs versus Limbal Relaxing Incisions Alexander Chop PhD MD (no.
Poster Number: P90 Category: Intraocular Surgery (Cataract and Refractive) Optimization of IOL Power Calculation Constants: By Unit or by Surgeon? Nathaniel.
Clinical results of the aphakia correction using iris-fixated anterior chamber intraocular lens (Artisan) Authors have no financial interest Luis Izquierdo.
Comparison of Autokeratometry and Manual Keratometry
Hong A, Boehlke CS, Afshari NA, Kim T Duke University Medical Center
Vicente J. Correa-Gomez MD, Guillermo Tapia MD, Oscar Macias Manuel MD, Alejandro Navas Perez MD, Gilberto Islas MD, Tito Ramírez-Luquin MD, Enrique O.
Roxana Ursea, MD Matthew T. Feng, MD Ovette Villavicencio, PhD
PATIENTS’ CHARACTERISTICS Table 1.1: Age distributions
IN THE NAME OF GOD.
Results of corrective surgery: secondary lens implantation at a cataract surgery training centre Mehul Shah,shreya shah, adway appalware,pramod upadhyay,
Factors Potentially Affecting the Accuracy of Methods to Calculate Effective Refractive Power After Keratorefractive Surgery Helga P Sandoval, MD, MSCR,
Anand K Shah MD1 Neda Shamie MD1 Paul Phillips MD1 Mark A Terry MD1,2*
Khairidzan Mohd Kamal MD
Visual Outcomes and Satisfaction with Toric IOL Versus Monofocal IOL
International Vision Correction Research Centre
Michael Goodman, Alexandra Paul and Andrew Hsu
Presentation transcript:

Corneal Pachymetry in Prediction of Refraction After Cataract Surgery Muneera A. Mahmood, MD, FRCOphth Martin F. Wilkes, MD None of the authors have financial interests to disclose.

Background Corneal pachymetry is a ready available and easily obtainable measurement To our knowledge, the potential association between corneal pachymetry and post-operative refraction following cataract surgery has not been looked at Given that many assumptions are made regarding prevailing Intraocular lens implant (IOL) calculation formulas (pachymetry, ratio of Ant/Post corneal curvature, refractive index of the cornea), it seems plausible that corneal thickness may have an effect on refraction

Purpose To determine if pre-operative corneal pachymetry is a predictor of refraction after cataract surgery, independent of axial length and keratometry measurements, used in conventional biometry predictive formulas.

Methods & Study Design IRB approved retrospective review of 91 eyes of 91 patients operated on between January 1, 2004 and March 30, 2009 Pachymetry measurements obtained via Anterior Segment OCT (AS-OCT; Zeiss Visante ) or Ultrasound (US; DGH Technology Inc, Pachette 2) Each patient had complete pre-operative evaluation including: Visual acuity (VA) and Manifest Refraction Slit lamp and dilated fundoscopic examination Pre-operative IOL measurements obtained via immersion A-scan biometry (Innovative Imaging Inc.) or IOL master (Zeiss) IOL power was calculated using the SRK/T formula Post-operative refraction and best-corrected visual acuity were recorded 8-10 weeks following surgery.

Exclusion Criteria Inclusion Criteria Placement of an SA60AT IOL in the bag Post-op VA of at ≥ 20/60 Pre-op corneal pachymetry measurement (AS-OCT or US) History of prior refractive surgery or scleral buckling Complicated cataract surgery with history of posterior capsule rupture Post-operative cystoid macular edema

Demographics Patients: 91 (all male) Mean age: 71.9 Average Pachymetry (µ): 547.7

Results Strength of prediction of post-operative refraction based on pachymetry was determined by multivariable linear regression analysis Calculation yielded the following equation: Post-op Refraction = -1.59 + (1.18 x SRK/T prediction) +( 0.0030 x Pachymetry) Slope of 0.0030 D / µ : each 100 µ change in thickness changes the post-operative refraction by 0.3 D. The p-value of the above calculation is 0.057.

Results The positive correlation between pachymetry and the error of predicted refraction is displayed Error of predicted refraction Pre-operative Pachymetry

Conclusions Pachymetry appears to have a considerable and possibly clinically significant effect on post-operative refraction, although not statistically significant in our study

Limitations/Considerations Small sample size Variability in method of obtaining pachymetry readings Variability in Manifest Refraction, obtained by different technicians

References 1. Haigis W. Occurrence of erroneous anterior chamber depth in the SRK/T formula. J Cataract Refract Surg. 1993 May; 19(3):442-6. 2. Jabbour J, Irwig L, Macaskill P, Hennessy MP. Intraocular lens power in bilateral cataract surgery: whether adjusting for error of predicted refraction in the first eye improves prediction in the second eye. J Cataract Refract Surg. 2006;32:2091-7. 3. Keriechbaum K, Findl O, Preussner P, Koppl C, Wahl J, Drexler W. Determining postoperative anterior chamber depth. J Cataract Refract Surg 2003; 29:2122-2126. 4. Olsen T, Corydon L, Gimbel H. Intraocular lens power calculation with an improved anterior chamber depth prediction algorithm. J cataract Refract Surg. 1995 May ; 21(3):313-9. 5. Olsen T. Sources of error in intraocular lens power calculation. J cataract Ref Surg. 1992 Mar; 18(2):125-9.