FINAL YEAR PROJECT 4SSCZ

Slides:



Advertisements
Similar presentations
Lab B4: The Creation and Annihilation of Antimatter SFSU Physics 490 Spring 2004 Professor Roger Bland.
Advertisements

Sci-Fi tracker for IT replacement 1 Lausanne 9. December 2010.
Study of the MPPC Performance - contents - Introduction Fundamental properties microscopic laser scan –check variation within a sensor Summary and plans.
Microscope Performance at elevated dark rates Richard Jones University of Connecticut collaboration GlueX collaboration meeting, Newport News, Feb. 2-4,
Characterization of Silicon Photodetectors (Avalanche Photodiodes in Geiger Mode) S. Cihangir, G. Mavromanolakis, A. Para. N.Saoulidou.
6mm 【 Development of Readout Electronics for MPPC 】 We report the read out electronics of MPPC( Multi-Pixel Photon Counter ). MPPC is a new photodetector.
Photon detection Visible or near-visible wavelengths
Test of Silicon Photomultipliers (SiPM) at Liquid Nitrogen Temperature Yura Efremenko, Vince Cianciolo nEDM CalTech Meeting 02/14/2007.
Characterization of Silicon Photomultipliers for beam loss monitors Lee Liverpool University weekly meeting.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
H.-G. Moser Max-Planck-Institut for Physics, Munich CALOR 06 Chicago June 5-9, 2006 Silicon Photomultiplier, a new device for low light level photon detection.
Fast Detectors for Medical and Particle Physics Applications Wilfried Vogel Hamamatsu Photonics France March 8, 2007.
Evaluation of Silicon Photomultiplier Arrays for the GlueX Barrel Calorimeter Carl Zorn Radiation Detector & Medical Imaging Group Jefferson Laboratory,
MPPC Radiation Hardness (gamma-ray & neutron) Satoru Uozumi, Kobe University for Toshinori Ikuno, Hideki Yamazaki, and all the ScECAL group Knowing radiation.
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
Silicon Photomultipliers
10/26/20151 Observational Astrophysics I Astronomical detectors Kitchin pp
Uncertainty in light measurement instrumentation examples1 For light sensors, uncertainty is closely related to light intensity … but not only… Let’s have.
R&D of MPPC for T2K experiment PD07 : Photosensor Workshop /6/28 (Thu) S.Gomi T.Nakaya M.Yokoyama H.Kawamuko ( Kyoto University ) T.Nakadaira.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
Study of the MPPC performance - R&D status for the GLD calorimeter readout – Nov 6-10.
1 Development of Multi-Pixel Photon Counters (1) S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira, K.Yoshimura, (KEK) Oct
1 MPPC update S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira (KEK) Nov KEK.
Development of Multi-Pixel Photon Counters(MPPC) Makoto Taguchi Kyoto University.
1 SiPM studies: Highlighting current equipment and immediate plans Lee BLM Quasar working group.
Towards a high-resolution fluorescence telescope B. Tomé (LIP) IDPASC School on Digital Counting Photosensors for Extreme Low Light Levels, Lisboa,
Medical applications of particle physics General characteristics of detectors (5 th Chapter) ASLI YILDIRIM.
Prospects to Use Silicon Photomultipliers for the Astroparticle Physics Experiments EUSO and MAGIC A. Nepomuk Otte Max-Planck-Institut für Physik München.
W. Kucewicz a, A. A.Bulgheroni b, M. Caccia b, P. Grabiec c, J. Marczewski c, H.Niemiec a a AGH-Univ. of Science and Technology, Al. Mickiewicza 30,
1 Chapter No. 17 Radiation Detection and Measurements, Glenn T. Knoll, Third edition (2000), John Willey. Measurement of Timing Properties.
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan for the GLD Calorimeter.
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
Study and Development of the Multi-Pixel Photon Counter for the GLD Calorimeter Satoru Uozumi (Shinshu, Japan) on behalf of the GLD Calorimeter Group Oct-9.
The VSiPMT: A new Generation of Photons Detectors G. Barbarino 1,2, F. C. T. Barbato 1,2, R. de Asmundis 2, G. De Rosa 1,2, F. Di Capua 1, P. Migliozzi.
Status of NEWCHOD E.Guschin (INR), S.Kholodenko (IHEP), Yu.Kudenko (INR), I.Mannelli (Pisa), O.Mineev (INR), V.Obraztsov (IHEP), V.Semenov(IHEP), V.Sugonyaev.
Update on works with SiPMs at Pisa Matteo Morrocchi.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
M.Teshima (MPP, U-Tokyo) M.Pimenta (LIP) T.Schweizer (MPP)
Development of UV-sensitive MPPC for upgrade of liquid xenon detector in MEG experiment Daisuke Kaneko, on behalf of the MEG Collaboration µ γ Liquid xenon.
 A) Pulse Height Spectroscopy  Identify the equipment such as detector, electronics modules and NIM.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
Study of the Radiation Damage of Hamamatsu Silicon Photo Multipliers Wander Baldini Istituto Nazionale di Fisica Nucleare and Universita’ degli Studi di.
FARICH status E.A.Kravchenko Budker INP, Novosibirsk, Russia.
Performance of 1600-pixel MPPC for the GLD Calorimeter Readout Jan. 30(Tue.) Korea-Japan Joint Shinshu Univ. Takashi Maeda ( Univ. of Tsukuba)
MOHAMAD KHALIL APC LABORATORY PARIS 17/06/2013 DSSD and SSD Simulation with Silvaco.
Characterisation of a pixellated CsI detector for the Distinguish Project. 1 Martin Jones The University of Liverpool
Development of Multi-Pixel Photon Counters (1)
Idee per lo sviluppo del Charge Identifier
Frontier Detectors for Frontier Physics
Characteristics of S12045(X) photon sensors for GlueX
大強度
Charge Coupled Device Advantages
Application of Nuclear Physics
Gamma-Gamma Correlations in Na-22
GAJENDRA KUMAR EC 3rd YR. ROLL NO
Photoelectric Effect Maximum kinetic energy of the electron:
Scintillation Counter
HE instrument and in-orbit performance
MPPC for T2K Fine-Grained Detector
ME instrument and in-orbit performance
ASPID (Application of Silicon Photomultipliers to Imaging Detectors)
SoLID EC photonsensor.
UCM-ELEC group Members involved in the work described here
Readout Electronics for Pixel Sensors
Readout Electronics for Pixel Sensors
The MPPC Study for the GLD Calorimeter Readout
Computed Tomography (C.T)
Hamamatsu’s SiPM (MPPC) Characteristics and Latest Developments
Readout Electronics for Pixel Sensors
Presentation transcript:

FINAL YEAR PROJECT 4SSCZ Progress Presentation NURDYANA BINTI RAMLEE NUR FATIN NASUHA BINTI JAAFAR

PROBLEM STATEMENT In cargo scanning system, the image form was not clear when detect transmission x-ray only. To get clear image, backscatter x-ray must be detect. In this project, backscatter x-ray represent as photon will be detect by using MPPC.

OBJECTIVES The main objectives of this research are as follows: To construct the prototype of x-ray backscatter detector using MPPC. Test the prototype using alpha, beta, gamma and x-ray source. To measure the backscatter x-ray that represent as photon. To estimate and determine the detector resolution.

WHAT IS BACKSCATTER X-RAY? Backscatter x-ray is produced from Compton Scattering process. In cargo scanning system, the energy of incident photon (x-ray) is higher than binding energy of atomic electron, then can treat the electron as free electron. This technique involves positioning both source and detection apparatus on only one side of a target object. The collision of a photon by a charged particle, usually an electron. It results in a decrease in energy (increase in wavelength) of the photon (which may be an X ray or gamma ray photon), called the Compton effect.

EXPECTED PROTOTYPE POSITION

MPPC DETECTOR Multi-Pixel Photon Counter ( MPPC ) is a new type of photodetector device developed by Hamamatsu Photonics. Is a Si-PM (silicon photomultiplier) device Sensitive area of MPPC detector

significant Characteristics of MPPC High Gain and low noise Low Dark Count Low Crosstalk Low Afterpulses Fast response High Photon detection efficiency Excellent Time resolution

EASIROC-NIM MODULE EASIROC-NIM MODULE is an optical measurement modules Capable of measuring light over a wide range of light levels (10 orders of magnitude) This module is equipped with a chip called EASIROC. EASIROC stands for Extended Analogue SI- pm ReadOut Chip is a 32 channels fully analogue front end ASIC dedicated to readout SiPM detectors.

When light enters the MPPC at particular time Output pulse height varies depending on the number of photons detected The pulses separated from each other according to the number of detected photon. Observing pulse Figure shows the pulse waveforms when using a linear amplifier

Intergrating the output charge Figure shows a distribution plotted for the amount of charge accumulated in the intergration time Intergrating the output charge When light enters the MPPC at variable time The number of photons detected within a certain time period can be estimated by integrating the MPPC output Using intergrating amplifier

Features Low afterpulses new MPPC reduced afterpulses due to use of improved materials and wafer process technologies. Reduces the generation of delayed output signal

Low crosstalk Lower the generation of other pulses by affected pixels

HIGH PHOTON DETECTION EFFICIENCY Graph of Photon detection efficiency(%) vs Overvoltage(V) The table shows some recommended overvoltage.

END