BioTector Diagnostic Download

Slides:



Advertisements
Similar presentations
Water Quality Testing Made Easy GPS Aquameter and Multiparameter Aquaprobe The perfect solution for your water quality testing needs.
Advertisements

SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
Analog-to-Digital Converter (ADC) And
1 Hardy Process Solutions – New Product Introduction HI6600 Series – Modular Sensor System Hardy delivers productivity solutions to manufacturers and processors.
Calibration Procedure.  A winch calibration is completed via a linear interpolation between 2 points.  Requires 2 references  Known lower weight 
Control System Instrumentation
EESIFLO International Pte Ltd
What is the It is the Next Generation, Calibration Station for the GasBadge ® Plus Personal Monitor
Engineering 1040: Mechanisms & Electric Circuits Winter 2015 Analog & Digital Signals Analog to Digital Conversion (ADC)
GML-3 GPRS BASED METER AND LOGGER THREE PHASE METER WITH INBUILT DATA LOGGER © Embuilt Technologies Visit us at Or For.
Programmable Logic Controllers
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
Control System Instrumentation
HD target.
Radiometric Correction and Image Enhancement Modifying digital numbers.
Computer Control.
SmartMQn Motor Horner APG, LLC September 9, 2008.
New Product Developments World Leaders in Combustion Management Solutions Mk7 Expansion PCB Mk7 Expansion PCB.
Hydro Multi-B – (2) or (3) CME Pumps in Parallel
Service Section Technical Training December 2005.
Water Horner APG, LLC June 4, What is SmartMQn Water? SmartMQn Water is a packaged monitoring solution that uses sophisticated and easy to use preconfigured.
Measurements Measurements and errors : - Here, the goal is to have some understanding of the operation and behavior of electrical test instruments. Also,
1 Chapter No. 17 Radiation Detection and Measurements, Glenn T. Knoll, Third edition (2000), John Willey. Measurement of Timing Properties.
The complete flow monitoring solution Measure – Display – Switch – Transmit.
F-900 PORTABLE ETHYLENE ANALYZER INSTRUMENT TRAINING
PCAR Precision In Practice 1 Precision In Practice Achieving the best results with precision Digital Multimeter measurements Paul Roberts Fluke Precision.
Digitization at Feed Through R&D (2) Digitizer Performance Evaluation Student: John Odeghe ; SC State, Fermi Lab Intern Supervisor: JinYuan Wu; Fermi Lab.
1 Chapter No. 9 Measurements and Detection of Radiation, Nicholas Tsolfanadis, 2010, McGRAW-HILL BOOK INTRODUCTION TO SPECTROSCOPY.
SF6 contamination by air in the Pelletron Recycler Departmental Meeting November 5, 2008 A. Shemyakin.
Crashcourse Oscilloscope and Logic Analyzer By Christoph Zimmermann.
Data logging: The term 'data logging' refers to collecting or gathering data over a period of time. How Data is collected? Sensors are used to take readings.
BioTector COD TOC TN analyzer
The BioTector B7000i TOC analyzer with integrated oxygen concentrator
The BioTector B7000i TOC analyzer with integrated oxygen concentrator
The BioTector COD TOC TN analyzer
Introduction to the F-900.
Quick Start Guide for Flex Flow Pump
The BioTector COD TOC TN TP analyzer
Digital-to-Analog Analog-to-Digital
Generic Remote Interface Unit (RIU) Interface Control Document (ICD)
EMSA 22 Lab Module 1 Field Equipment Calibration
Monitoring systems COMET types MS55 & MS6
Control System Instrumentation
Data Logging.
SAR ADC Input Types TIPL 4003 TI Precision Labs – ADCs
Kessler-Ellis Products
Fault Screen (“FAULT”)
Principles of Instrumental Analysis
Industrial Instrumentation: Transmitters
Created by Dale Li, Art Kay Presented by Peggy Liska
MPU-16A / FPU-16 TEST UNIT TUTORIAL
Digital-to-Analog Analog-to-Digital
The BioTector B3500ul TOC analyzer Service and Maintenance
Electronic Control Systems Week 4 – Signaling and Calibration
AUTOMATED LIQUID DELIVERY SYSTEM
The BioTector B3500ul TOC analyzer Process Tests
TB8100 Technical Training July 2005
Control System Instrumentation
Control System Instrumentation
Overview Menus & Settings
Digital Chart Recorder Operation
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
Measurements Measurements and errors :
Diagnostics Analytical 920 LC Semi-Prep 940 LC
Analogue Inputs and Processing
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
Series 5300 Lithium Cell Formation System
COOLING WATER TREATMENT CONTROLLER
System 57 Gas Control System
Suppose we make a new compound containing of C,H, and N
Presentation transcript:

BioTector Diagnostic Download

BioTector Diagnostic Download The information in the BioTectors archive – Reaction archive, Fault archive and Diagnostics, can be downloaded to the SD card and transferred to a PC. The format is a Text file. The Reaction archive stores the last 8000 reactions. The Fault archive stores the last 99 faults. The Diagnostic archive stores diagnostic information held in the BioTector.

Basic Reaction Archive download, in Standard mode. This downloads Time, Date, Stream/Range, TIC and TOC data. This can also show Zero Calibrations ZC, span calibrations, SC, and more, see below. Hint: always look at the fault archive at the same time, to see if there are any related faults in the system. S1 to S6 – reactions from stream 1 to stream 6. M1 to M6 – reactions from manual sample stream 1 to manual stream 6. CF – full cleaning reaction. RW – reactor wash reaction. RS – remote standby reaction. ZC – zero calibration reaction. ZK – zero check reaction. ZM – manual zero adjust. SC – span factor calibration reaction. SK – span factor check reaction. SM –manual span factor adjust. A1 to A6 – 24 hours average result from stream 1 to stream 6.

Basic Reaction Archive download, in Engineering mode. This downloads the information shown below, in addition to Time, Date, Stream/Range, TIC and TOC data.

Engineering mode archive, what to look out for: CO2z CO2z (CO2 analyzer zero point). At the start of each reaction, the CO2 zero is recorded. Is this stable? For the BioTector G2 CO2 analyzer, typically each reading will be within 3-5 ppm of the last reading. For the older GD10 CO2 analyzer, this could vary by 25-50 ppm. Is the result within +/- 0.5% of full scale? If not, them the lens may have to be cleaned. Is the result close to or over 250ppm? Then confirm that there is no CO2 in the oxygen supply.

Engineering mode archive, what to look out for: TIC TICmgu (TIC un-calibrated), TICmgc (calibrated), CO2p (height of the CO2 peak). Is the TICmgu within +/- 25% of the TICmgc? Typically we find that the un-calibrated TIC is close to the calibrated TIC – and note that there is normally no zero offset from the TIC reading. Note that the simple reaction of TIC and acid in the reactor confirms: The sample is being injected into the reactor. The acid for the TIC is being injected into the reactor. The circulation pump is probably running (not as easy to deduce in the MCR reactor). The CO2 analyzer is reading. The MFC has a gas flow.

Engineering mode archive, what to look out for: TOC TOCmgu (TOC un-calibrated), TOCmgc (calibrated), CO2p (height of the CO2 peak). The comparison between TOCmgu and TOCmgc is not as easy here, due to the zero offset from the base. However, confirm that a zero calibration was run recently (ZC reaction), then you can do a rough calculation by subtracting the zero offset from the TOCmgu reading. For a good TOC reading: The base oxidation phase has to be effective - pH ~14, ozone generator operating, circulation pump circulating the liquid. The TOC phase has to be effective – pH ~0, manganese catalyst in the acid, ozone generator operating for first half of the phase, circulation pump circulating the liquid. Note that if you have no manganese catalyst in the acid, you result will be down ~33%.

Engineering mode archive, what to look out for: DegC, Atm DegC, Temperature in the BioTector. High alarm set to 45C. Atm, Atmospheric pressure sensor in the BioTector. Confirm that both of these readings are reasonable.

Engineering mode archive, what to look out for: SMPL PUMP SMPL PUMP: Diagnostic data from the sample pump. The same information is available for the reagent (acid and base) pumps. 1). Operating mode, 0= time mode, 1= pulse mode. The pump has a magnetic sensor, if this is working correctly, the mode should be “1”. If the sensor fails, the pump switches to a backup time based mode. Note that the pump could also be faulty / stopped. 2). Number of pulses during last operation, for example injection. 3). Time (milliseconds) for the above operation – note that this will change depending on the BioTectors range. 4). Time for the last pulse operation. For WMM60 pumps, this is typically 500-400 ms. For SR25 pumps (reagent) this is typically 700-600ms. If it is slower than this, the pump may be old. 5). Error counter. This counts up to 6 before logging a fault. It should always be 0, if not there may be an intermittent fault on the system.

Engineering mode archive, Calibration Curve data. This is produced for each range in the BioTector. It shows: The calibration and range. The current Zero Adjust. The current Span Adjust. APC = Factory Set Automatic Pressure Compensation factor, used to compensate for changes in atmospheric pressure. ATC = Factory Set Automatic Temperature Compensation and related temperature, with the current CO2 analyzers, these values are close to 1.00 Full calibration curve, as calculated by the BioTectors “constrained cubic spline” interpolation calculation. Used mainly in the factory to confirm that the calibration is correct.

Engineering mode archive, ATC data. Typical Factory Set ATC (automatic Temperature Compensation) table.

Engineering mode archive, Zero/Span Adjust data. Typical Zero and Span adjust record. Depending on the range, the zero adjust should be +/- 5% of full scale of the appropriate calibration. Outside of this, the base solution may be contaminated with a high level of carbonate, especially if the zero adjust is large and negative. The BioTector will still operate with a large zero adjust, but the accuracy will be effected. The Span Adjust factor should generally be close to 1.0. +/- 15% could be accounted for in a sample pump tube change, anything outside this should be investigated. However if you see a Span Adjust factor in the order of 1.5, then it is likely that the user has no Manganese catalyst in the acid.

Engineering mode archive, Analogue Input raw data. Typical Analogue Input data. The Analogue to Digital ADC converter has a resolution of 12 bits, or 1 in 4095. ADC1, CO2 analyzer, 4-20ma signal from the CO2 analyzer is read as 1-5v signal by the BioTector. Therefore, a ADC value of ~800 = 4ma = 0 ppm CO2. ADC2, MFC, as above. ADC3, Reserved. ADC4, Cooler Temperature. This temperature sensor has an output of 10mv for each degree F from 0F (-17.7C) to 100F (37.7C). In this example, the output is 580mv, which corresponds to 58F, or 14C. ADC5, Panel Temperature. This temperature sensor has an output of 10mv for each degree C, from 0C to 100C. ADC6, 7, Reserved. ADC8, Atmospheric Pressure Sensor. 150mbar has an output of 0.2V, 1150mbar has an output of 4.8V. ADC9, 12 Reserved.

Engineering mode archive, Previous Reaction CO2 data. Shows the CO2 analyzer output from the previous reaction. The left hand group of figures shows TIC, the figures below TOC. Base Oxidation CO2 results should be low (almost zero) and stable.

Engineering mode archive, Fault Status. Read from the bottom up (the bottom is the oldest data. This example is from an O2 flow record. Initially, the set-point (10) and flow (10.0-10.4) are the same, but when the set-point changes to 20, the flow drops off. Possible issue, out of oxygen. The faults logged in the Fault status archive are: O2 flow. Relay PCB fault (monitors the fuse status). Ozone PCB fault (monitors the fuse / power status). CO2 analyzer fault (logs the CO2 analyzer signal). Panel Temperature. Cooler Temperature.