Pharmaceutical Quality Control & current Good Manufacturing Practice

Slides:



Advertisements
Similar presentations
Stability data required by WHO-PQP Mercy Acquaye.
Advertisements

 Prepared by: Paras Shah  Guided by: Dhaval Rathod.
Batch Reworking and Reprocessing
World Health Organization
SAE AS9100 Quality Systems - Aerospace Model for Quality Assurance
IFSQN CODEX and Good Manufacturing Practice Training Guide.
Quality Management System
FEDERAL REGULATIONS OF MEDICATIONS Food, Drug and Cosmetic Act Protect consumers from adulterated and misbranded foods, drugs, cosmetics, or devices.
All You Never Wanted to Know About GLP and GMP
Reference standards Bujji Kanchi.
Quality control of raw materials In-process control
Reference, Retention and Reserve Samples
Distributed Manufacturing via the SNM Multicenter FLT IND Part II SNM Midwinter Clinical Trials Network Albuquerque, New Mexico February 2, 2010 Sally.
Sampling, Identification and Testing (S.I.T.). IntroductionIntroduction Define basic principles for applying sampling, identification and testing requirements.
VALIDATION OF RAW MATERIALS
Good Hygiene Practices Incoming Material Requirements Section 2 - Sub-Module 5.2.
Huzairy Hassan School of Bioprocess Engineering UniMAP.
© 2009 Michigan State University licensed under CC-BY-SA, original at Corrective Action.
BRC Food Safety Quality Management System Training Guide
World Health Organization
Good Laboratory Practice
Current Good Manufacturing Practices (cGMP’s). Biotechnology using living cells and materials produced by cells to create pharmaceutical, diagnostic,
Introduction to Equipment
Understanding cGMPS – What Attorneys Need to Know The Nuts + Bolts of cGMPS July 10, CFR Parts 210 and 211 cGMP case law Andrew D. Bos Senior Director.
Good Manufacturing Practices
A Basic Overview of the US FDA’s Regulations for Regulatory Compliance
Inspection Issues in the Analytical Laboratory: An FDA Perspective Yvonne McKnight Chemist US Food and Drug AdministrationPhone: x
General requirement: There shall be written procedures describing in sufficient detail the receipt, identification, storage, handling, sampling, testing.
Good Manufacturing Practice. Good Manufacturing Practice Regulations Establishes minimum GMP for methods to be used, and the facilities or controls to.
ZHRC/HTI Financial Management Training Session 9: Stores and Supplies Management.
Important informations
PACKAGING AND LABELING CONTROL
Aloe Vera of America: A Quality IASC-Certified Producer of Aloe Vera Presented by Walt Jones.
Proposed Rule for Preventive Controls for Animal Food.
Proposed Rule: 21 CFR 507 Proposed Rule for Preventive Controls for Animal Food 1.
WHO - PSM Materials Pharmaceutical Quality, Good manufacturing Practice & Bioequivalence Kiev, Ukraine October 2005 Maija Hietava M.Sci.Pharm Quality.
Draft Guidance for Industry: CGMPs for Phase 1 INDs Joseph C. Famulare, Director Division of Manufacturing & Product Quality Office of Compliance, CDER,
Basic Principles of GMP
Module 14Slide 1 of 23 WHO - EDM Basic Principles of GMP Active Pharmaceutical Ingredients Part Three, 18.
Pharmaceutical Quality Control & current Good Manufacturing Practice PHT 436 Lecture 8 1.
Storage of Pharmaceutical Products Dr. Basavaraj K. Nanjwade M. Pharm., Ph. D Department of Pharmaceutics Faculty of Pharmacy Omer Al-Mukhtar University.
Pharmaceutical Quality Control & current Good Manufacturing Practice PHT 436 Lecture 7 1.
Pharmaceutical Quality Control & current Good Manufacturing Practice
ISO 9001:2015 Subject: Quality Management System Clause 8 - Operation
Good Manufacturing Practice (GMP) Compliance: GMPs EXPLAINED.
WORKSHOP ON ACCREDITATION OF BODIES CERTIFYING MEDICAL DEVICES INT MARKET TOPIC 9 CH 8 ISO MEASUREMENT, ANALYSIS AND IMPROVEMENT INTERNAL AUDITS.
Quality Control significance in pharmaceutical industry
Storage, Labeling, Controlled Medications Guidance Training CFR § (b)(2)(3)(d)(e) F431.
LABORATORY SAMPLES AND CONTRACT MANAGEMENT
BSB Biomanufacturing CHAPTER 11 GMP – Pharmaceutical Water
Pharmaceutical Quality Control & current Good Manufacturing Practice
BSB Biomanufacturing CHAPTER 4 GMP – Documentation Part I (SOP)
Author: Nurul Azyyati Sabri
GOOD MANUFACTURING PRACTICE FOR BIOPROCESS ENGINEERING (ERT 425)
Pharmaceutical Quality Control & current Good Manufacturing Practice
2.4 : Good Compounding Practice (GCP)
DISTRIBUTION AND DISTRIBUTION RECORDS
Pharmaceutical Quality Control & current Good Manufacturing Practice
Quality Assurance and Quality Control in Generics
Quality Control Procedures & Raw Materials
WHO Technical Report Series, No. 953, 2009
Quality Systems in a Production Facility
Introduction to GMP.
Chapter-3 Current Good Compounding Practices Fifth Stage
FDA Quality System Regulation
World Health Organization
Food Safety T-1150 This work has been produced by DGL (Aust) Pty Ltd
Supplier Briefing Pack
Quality Control Procedures & Raw Materials
Radiopharmaceutical Production
Presentation transcript:

Pharmaceutical Quality Control & current Good Manufacturing Practice PHT 436 Lecture 9

Current Good Manufacturing Practices Regulations Subpart E Current Good Manufacturing Practices Regulations Subpart E. Control of components and drug product containers and closures 211.80 - General requirements. 211.82 - Receipt and storage of untested components, drug product containers, and closures. 211.84 - Testing and approval or rejection of components, drug product containers, and closures. 211.86 - Use of approved components, drug product containers, and closures. 211.87 - Retesting of approved components, drug product containers, and closures. 211.89 - Rejected components, drug product containers, and closures. 211.94 - Drug product containers and closures.

Sec. 211.86 Use of approved components, drug product containers, and closures. Components, drug product containers, and closures approved for use shall be rotated so that the oldest approved stock is used first. Deviation from this requirement is permitted if such deviation is temporary and appropriate.

Using oldest stock first helps: to reduce the possibility of contamination, and to assure that material conforms to appropriate requirements. An exemption from strict use of oldest stock first is provided when: it may be desirable to package using a single lot of components, containers or closures. for evaluation of a new supplier, or new equipment or processes with respect to preferred lot of materials, or the temporary physical inaccessibility of the oldest stock. Materials management systems include a need to reevaluate material after a predetermined time and prior to use. This will further minimize the chance that materials in an unsuitable condition will be used.

Sec. 211.87 Retesting of approved components, drug product containers, and closures. Components, drug product containers, and closures shall be retested or re-examined, as appropriate, for identity, strength, quality and purity and approved or rejected by the quality control unit as necessary, e.g., after storage for long periods or after exposure to air, heat or other conditions that might adversely affect the component, drug product container and closure.

This reevaluation will not usually require full testing but only examination of those parameters known to be subject to change. For infrequently used materials, reevaluation may be delayed until the material is required. Degradation is not always linear, and in some instances a limited accelerated stability study may prove advisable.

For sensitive materials must be stored under the appropriate conditions where these are specified. Where not specified it may still be advisable to identify and use positions in the warehouse that are least susceptible to the adverse climate changes. During storage, degradation may occur, moisture may be absorbed or materials may simply become covered in dust.

Re-evaluation time-scales are usually developed from historical data Re-evaluation time-scales are usually developed from historical data. Except for particularly sensitive materials, it is usual to settle or one time period often one year. The product release label or the system should clearly indicate when materials are to be re-evaluated.

Sec. 211.89 Rejected components, drug product containers, and closures. Rejected components, drug product containers and closures shall be indentified and controlled under a quarantine system designed to prevent their use in manufacturing or processing operations for which they are unsuitable.

Although a segregated reject area is not required if an adequate control system exists, many companies do segregate reject materials. This is an added precaution against inadvertent use. FDA investigators frequently use a visit to the reject area as a potential source of deficiencies. If rejections occur it is possible to assume that the vendor process is not adequately under control, and an evaluation of the cause should have been performed and documented.

Sec. 211.94 Drug product containers and closures. Drug product containers and closures shall not be reactive, additive, or absorptive so as to alter the safety, identity, strength, quality, or purity of the drug beyond the official or established requirements. Container closure systems shall provide adequate protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the drug product.

Drug product containers and closures shall be clean and, where indicated by the nature of the drug, sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use. Standards or specifications, methods of testing, and where indicated, methods of cleaning, sterilizing and processing to remove pyrogenic properties shall be written and followed for drug product containers and closures.

USP provides information on specifications and test methodology for a range of container materials. These include: Light transmission for glass and plastics. Chemical resistance for glass. Arsenic extraction from Type 1 glass. Biological tests on plastics used for parenterals. Physicochemical tests on plastics used for parenterals. Biological tests on plastics used for ophthalmic products. Chemical tests on polyethylene containers for dry oral dosage forms.

Current Good Manufacturing Practices Regulations Subpart G-Packaging and Labeling Control

Sec. 211.122 Materials examination and usage criteria. There shall be written procedures describing in sufficient detail the receipt, identification, storage, handling, sampling, examination, and/or testing of labeling and packaging materials; such written procedures shall be followed. Labeling and packaging materials shall be representatively sampled, and examined or tested upon receipt and before use in packaging or labeling of a drug product. (b) Any labeling or packaging materials meeting appropriate written specifications may be approved and released for use. Any labeling or packaging materials that do not meet such specifications shall be rejected to prevent their use in operations for which they are unsuitable.

Specification for container and closures A description of the components. A statements of chemical composition and method of manufacturing when critical. Size and dimension requirements. Colour requirements. Reference to specific manufacturing process necessary to make the article acceptable to pharmaceutical production. Packaging and labelling requirements for shipment to pharmaceutical plants.

(c) Records shall be maintained for each shipment received of each different labeling and packaging material indicating receipt, examination or testing, and whether accepted or rejected. (d) Labels and other labeling materials for each different drug product, strength, dosage form, or quantity of contents shall be stored separately with suitable identification. Access to the storage area shall be limited to authorized personnel. (e) Obsolete and outdated labels, labeling, and other packaging materials shall be destroyed.

(f) Use of gang-printed labeling for different drug products, or different strengths or net contents of the same drug product, is prohibited. unless the labeling from gang-printed sheets is adequately differentiated by size, shape, or color.

(g) If cut labeling is used for immediate container labels, individual unit cartons, or multiunit cartons containing immediate containers that are not packaged in individual unit cartons, packaging and labeling operations shall include one of the following special control procedures: (1) Dedication of labeling and packaging lines to each different strength of each different drug product; (2) Use of appropriate electronic or electromechanical equipment to conduct a 100-percent examination for correct labeling during or after completion of finishing operations; (3) Use of visual inspection to conduct a 100-percent examination for correct labeling during or after completion of finishing operations for hand-applied labeling. Such examination shall be performed by one person and independently verified by a second person. (4) Use of any automated technique, including differentiation by labeling size and shape, that physically prevents incorrect labeling from being processed by labeling and packaging equipment.

(h) Printing devices on, or associated with, manufacturing lines used to imprint labeling upon the drug product unit label or case shall be monitored to assure that all imprinting conforms to the print specified in the batch production record.

The midterm exam will be from lecture 1 to lecture 6 The midterm exam will be from lecture 1 to lecture 6. Tuesday 14/5/1437 10:00 – 10:50 am