Application of AMS for the Analysis of

Slides:



Advertisements
Similar presentations
1 ORISS Isomer and Isobar Spectrometer and Separator for Study of Exotic Decays A. Piechaczek for the.
Advertisements

Ionization and Mass Analyzers Ionizations –Electron Ionization - “hard” –Chemical Ionization - “soft” –MALDI - desorption –FAB - desorption –Laser Post.
WP3: R&D on ultra low-level detectors and facilities WP3: R&D on ultra low-level detectors and facilities LNGS: status and outlook.
Materials Assay & ICPMS for DUSEL R&D
Background Study in NDBD Ming Shao. sources environmental gamma radioactivity cosmic rays Neutrons Radon contamination of materials which detectors and.
frostburg. edu/chem/senese/101/matter/slides/sld006
Superheavy Element Studies Sub-task members: Paul GreenleesJyväskylä Rodi Herzberg, Peter Butler, RDPLiverpool Christophe TheisenCEA Saclay Fritz HessbergerGSI.
LAUNCH - Low-energy, Astroparticle Underground, Neutrino physics and Cosmology in Heidelberg, Low-level techniques applied in experiments.
V. V. Parkhomchuk, S.A. Rastigeev BINP, Novosibirsk, Russia. ION SELECTION IN ACCELERATOR MASS SPECTROMETER BINP SB RAS.
Proposal for high sensitive measurements of 238 U and 232 Th with NAA Ezio Previtali INFN Sez. Milano Milano-Bicocca University ILIAS: JRA1 3rd General.
Gamma spectrometry in deep sea water
Stefano Pirro LRT-2004 Sudbury December 13, 2004 Cleanliness backgrounds and surface contaminations in Cuore Stefano Pirro INFN-Milano.
Lee, Myeong Jae DMRC, Seoul national university
Isospin impurity of the Isobaric Analogue State of super-allowed beta decay experimental technique isospin impurity determination Bertram Blank, CEN Bordeaux-Gradignan.
 Remember that the nucleus is comprised of the two nucleons, protons and neutrons.  The number of protons is the atomic number.  The number of protons.
Ion Beam Analysis Dolly Langa Physics Department, University of Pretoria, South Africa Blane Lomberg Physics Department, University of the Western Cape,
Mass Spectroscopy 1 Mass Spectroscopy (Mass Spec) Applying Atomic Structure Knowledge to Chemical Analysis.
Possibilities for AMS experiments at ATLAS Philippe Collon, University of Notre Dame.
th KPS meeting 1 Development of Radon Monitoring Detector for the KIMS Experiment Lee, Myoung Jae DMRC, Seoul national university.
Workshop for Underground experiments and astroparticle physics 1 Radon Environment of Underground Experiment and Detection of Radon Lee, Myeong.
Topical Workshop in Low Radioactivity Techniques, Sudbury, Canada, August 28-29, 2010 Surface cleaning techniques B. Majorowits a, M. Wójcik b, G. Zuzel.
Mass spectrometry (Test) Mass spectrometry (MS) is an analytical technique that measures masses of particles and for determining the elemental composition.
INTERNATIONAL PHD PROJECTS IN APPLIED NUCLEAR PHYSICS AND INNOVATIVE TECHNOLOGIES This project is supported by the Foundation for Polish Science – MPD.
Experimental part: Measurement the energy deposition profile for U ions with energies E=100 MeV/u - 1 GeV/u in iron and copper. Measurement the residual.
May 6, 2006Henderson Dusel Capstone Meeting Low Background Counting A Facility Wish List for the New Underground Laboratory F. Calaprice.
Underground Laboratories and Low Background Experiments Pia Loaiza Laboratoire Souterrain de Modane Bordeaux, March 16 th, 2006.
Stellenbosch University
M. Wójcik for the GERDA Collaboration Institute of Physics, Jagellonian University Epiphany 2006, Kraków, Poland, 6-7 January 2006.
VIeme rencontres du Vietnam
Ultra-low background gamma spectrometry 2 nd LSM-Extension Workshop, Valfréjus, 16 October 2009 Pia Loaiza Laboratoire Souterrain de Modane.
M. Wójcik Instytut Fizyki, Uniwersytet Jagielloński Instytut Fizyki Doświadczalnej, Uniwersytet Warszawski Warszawa, 10 Marca 2006.
Pia Loaiza AARM March 2010 Background studies for EURECA EURECA The ‘submarine’ (water tank) design: background expected from stainless steel structure.
Basics of Ion Beam Analysis
Why Accelerator Mass spectrometry (AMS) The determination of the concentration of a given radionuclide in a sample can be done in 2 ways: a) measure the.
Activities on double beta decay search experiments in Korea 1.Yangyang Underground laboratory 2.Double beta decay search with HPGe & CsI(Tl) 3.Metal Loaded.
A screening facility for next generation low-background experiments Tom Shutt Case Western Reserve University.
LIST status and outlook Sven Richter for the LIST-, RILIS- and Target-Collaborations 21 st of August 2013.
Mass Spectrometry Relative atomic masses and the mass of individual isotopes can be determined using a mass spectrometer. The principle behind mass spectrometry.
GeMPI-type low background counting system for SURF Kara Keeter 15 September 2014.
1 Double Beta Decay of 150 Nd in the NEMO 3 Experiment Nasim Fatemi-Ghomi (On behalf of the NEMO 3 collaboration) The University of Manchester IOP HEPP.
Environmental and Climate Research using AMS Karin Hain
VALIDATION OF THE FLUKA MONTE CARLO CODE FOR RESIDUAL PRODUCTION WITH 500 MeV/u AND 950 MeV/u URANIUM BEAM ON COPPER AND STAINLESS STEEL TARGET E. Kozlova.
Activation by Heavy-Ion Beams
Nuclear Pharmacy Lecture 2.
M. Fernández, E. Conde, A.I. Barrado Department of Technology
S. A. Rastigeev , A. R Frolov, A. D. Goncharov, V. F. Klyuev, E. S
NOTATIONS TO WRITE ISOTOPES
The Mass Spectrometer Honours
In-source laser spectroscopy of mercury isotopes (P-424)
Continuous Flow Isotope Ratio Mass Spectrometry
Department of Tandem Accelerators
Pulse-shape discrimination with Cs2HfCl6 crystal
Dark Matter Search With an Ultra-low Threshold Germanium Detector proposed by Tsinghua University Seoul National University Academia Sinica Qian Yue.
Prompt Gamma Activation Analysis on 76Ge
On measurability of mBq/kg levels of alpha activity
Serge Nagorny – GSSI-INFN
n_TOF annual meeting December 2011, Lisbon
Labor of Ion Beam Physics, ETHZ
Laser assisted decay spectroscopy at the cris beam line at
Quadropole Mass Analyzer
Triangle Universities Nuclear Laboratory
Instrumental Chemistry
Mass Spectrometry.
H. Simgen, MPI for Nuclear Physics / Heidelberg
Measuring 14C concentrations with AMS
Neutron Activation Analysis
Triangle Universities Nuclear Laboratory
Mass Spectrometry THE MAIN USE OF MS IN ORG CHEM IS:
Isotope Ratio Mass Spectrometers (IRMS)
Suppose we make a new compound containing of C,H, and N
Presentation transcript:

Application of AMS for the Analysis of Primordial Nuclides in High Purity Copper (A feasibility study) G. Korschinek N. Famulok, T. Faestermann, L. Fimiani, J.M. Gomez Guzman, K. Hain, P. Ludwig, S. Schönert

Motivation: Low Level Experiments Certain dedicated experiments in modern physics require very low background e.g. GERDA, CRESST Passive shielding is made out of ultra-pure lead, steel or copper But radionuclides of primordial, cosmogenic and anthropogenic origin Credit: MPI Heidelberg Credit: cresst.de

Standard detection method: γ - Spectrometry Activity of daughter nuclides measured by γ-spectrometry Concentration of Th-232 and U-238 calculated assuming secular equilibrium

Motivation: Low Level Experiments Many experiments in astroparticle physics require very low background e.g. GERDA, CRESST Passive shielding is made out of ultra-pure lead, steel or copper But radionuclides of primordial, cosmogenic and anthropogenic origin Credit: MPI Heidelberg Credit: cresst.de Standard detection method: Gamma Spectrometry Complementary approach: Accelerator Mass Spectrometry

γ – Spectrometry - accelerator mass spectrometry Activity of daughter nuclides measured by γ-spectrometry Concentration of Th-232 and U-238 calculated assuming secular equilibrium is longsome to wait for the decay, Ra = Radium Accelerator mass spectrometry (AMS) determines directly Th-232 or U-238

Si surface barrier detector AMS setup at the MLL Si surface barrier detector Sample 90° Injector Magnet (1st Mass Separation) 18°Electrostatic Deflection Carbon Stripper Foil Wien Filter 90° Analyzing Magnet (2nd Mass Separation) Switching Magnet Negative Ions Positive 2.7m TOF Start − Time-of-flight setup (2.7m flight path) Faraday Cup Stop MCP detector Dedicated ion source for the detection of primordial nuclides in ultra-pure samples! Ion identification: TOF: ΔTOF ∼ 400ps Energy signal Cs reservoir HV feed through Ionizer Sample

Zr transition metall, easy to process, can only be dissoluted in HF or aqua regia

Si surface barrier detector AMS setup at the MLL Si surface barrier detector Sample 90° Injector Magnet (1st Mass Separation) 18°Electrostatic Deflection Carbon Stripper Foil Wien Filter 90° Analyzing Magnet (2nd Mass Separation) Switching Magnet Negative Ions Positive 2.7m TOF Start − Time-of-flight setup (2.7m flight path) Faraday Cup Stop MCP detector Dedicated ion source for the detection of primordial nuclides in ultra-pure samples! Ion identification: TOF: ΔTOF ∼ 400ps Energy signal Cs reservoir HV feed through Ionizer Sample

Motivation: Low Level Experiments Many experiments in astroparticle physics require very low background e.g. GERDA, CRESST Passive shielding is made out of ultra-pure lead, steel or copper But radionuclides of primordial, cosmogenic and anthropogenic origin Credit: MPI Heidelberg Credit: cresst.de Standard detection method: Gamma Spectrometry Complementary approach: Accelerator Mass Spectrometry No chemical treatment! Blank level? Extracted ion / molecule?

Copper Samples Normal copper (5.6kg) Laydown at the TUM Physics Dep.

Copper Samples

Copper Samples

γ – spectrometry at the LNGS Highly sensitive gamma spectrometry performed with GeMPI – detectors (μBq/kg range) “Korrodin“ screws and LENS (Low Energy Neutrino Spectroscopy) copper screened by M. Laubenstein et al. 2010 Korrodin: Counts above background LENS: Upper limits Radium, Protactinium

Measurement Principle Calibration of detection system with 197Au beam Calculation of region of interest for 232Th and 238U events

Measurement Principle Calibration of detection system with 197Au beam Calculation of Region of Interest for 232Th and 238U events Th & U extracted as copper compounds ThCu- & UCu- Good extraction efficiency and stable conditions

Measurement Principle Calibration of detection system with 197Au beam Calculation of Region of Interest for 232Th and 238U events Th & U extracted as copper compounds ThCu- & UCu- Good extraction efficiency and stable conditions “Korrodin“ sample is used as standard Unkown Th & U concentrations are determined relatively to “Korrodin“

Measurement Principle Calibration of detection system with 197Au beam Calculation of Region of Interest for 232Th and 238U events Th & U extracted as copper compounds ThCu- & UCu- Good extraction efficiency and stable conditions “Korrodin“ sample is used as standard Unkown Th & U concentrations are determined relatively to “Korrodin“ Faraday Cup 1 Cu current measured at Cup 1 to monitor performance of ion source Th & U events normalized to this current for all samples

Preliminary Results

Preliminary Results Concentrations in μBq/kg: Thorium Korrodin M-Copper LENS LNGS 945 ± 100 - < 19 AMS Standard 82 ± 35 59 ± 24 Uranium Korrodin M-Copper LENS LNGS 30 ± 7 - < 16 AMS Standard 2.1 1.0 +1.4 +1.1 -1.0 -0.8

Discussion and Outlook AMS competitive with other detection methods Much shorter measurement time and less samples mass than with gamma spectrometry No chemical treatment required Concentration values achieved: Uranium: ≤ 10 −14 g/g Extension of concentration measurements

Thank you! Zr transition metall, easy to process, can only be dissoluted in HF or aqua regia

A new Standard Sample: Blister Copper Contaminants: Ni, Sb, Zn, As + precious metals High purity p-type Ge detector Th-232 8.38 ± 3.30 mBq/kg (2.06 ± 0.81) · 10-9 g/g 118.78 ± 68.50 mBq/kg (9.54 ± 5.50) · 10-9 g/g Protaktinium, Telurium preliminary! Th-228 & Tl-208 Pa-234 Measured in Underground Laboratory in Garching (10 m.w.e.)

Zr transition metall, easy to process, can only be dissoluted in HF or aqua regia

Zr transition metall, easy to process, can only be dissoluted in HF or aqua regia

Si surface barrier detector AMS setup at the MLL Si surface barrier detector Sample 90° Injector Magnet (1st Mass Separation) 18°Electrostatic Deflection Carbon Stripper Foil Wien Filter 90° Analyzing Magnet (2nd Mass Separation) Switching Magnet Negative Ions Positive 2.7m TOF Start − Time-of-flight setup (2.7m flight path) Faraday Cup Stop MCP detector Dedicated ion source for the detection of primordial nuclides in ultra-pure samples! Ion identification: TOF: ΔTOF ∼ 400ps Energy signal Cs reservoir HV feed through Ionizer Sample

Motivation: Low Level Experiments Many experiments in astroparticle physics require very low background e.g. GERDA, CRESST Passive shielding is made out of ultra-pure lead, steel or copper But radionuclides of primordial, cosmogenic and anthropogenic origin Credit: MPI Heidelberg Credit: cresst.de Standard detection method: Gamma Spectrometry

Natural Decay Chains Zr transition metall, easy to process, can only be dissoluted in HF or aqua regia

Preliminary Results 232Th 238U 1.1 0.8 11 3

Discussion and Outlook AMS competitive with other detection methods Much shorter measurement time and samples mass than with gamma spectrometry No chemical treatment required in contrast to NAA, ICP-MS Very good concentration values achieved: Uranium: ≤ 10 −14 g/g Extension of concentration measurements

Discussion Concentrations in μBq/kg: Thorium Korrodin M-Copper LENS LNGS 945 ± 100 - < 19 AMS Standard 82 ± 35 59 ± 24 Uranium Korrodin M-Copper LENS LNGS 30 ± 7 - < 16 AMS Standard 2.1 1.0 +1.4 +1.1 -1.0 -0.8