Physiologic signals Lecture (2).

Slides:



Advertisements
Similar presentations
Recording. Normal Features.
Advertisements

Resting ECG An overview.
Optional or Required, EMT & AEMT
BIOPOTENTIAL AMPLIFIERS
Electrocardiography Prof. K. Sivapalan ECG 2 Principle of Electrocardiogram. Trunk as volume conductor. Positively charged and negatively charged.
ECG Biopotential Amplifier ASHLEY MULCHRONE ZEXI LIU.
Chapter Page, 12-Lead ECG for Acute and Critical Care Providers © 2006 by Pearson Education, Inc. Upper Saddle River, NJ 1 Lead Placement and Acquisition.
12-Lead ECGs and Electrical Axis
The Electrocardiogram
ELECTROCARDIOGRAM (ECG)
Cardiovascular System Block The Electrocardiogram (ECG)
ECG LEADS Chapter 3. introduction The heart produces electrical currents The body acts as a conductor of electricity.
Vital Signs Monitor UConn BME 4900 Vital Signs Monitor Purpose As the population ages, many people are required by their doctors to take vital signs.
Electrocardiogram Prepeared By Dr: Manal Moussa.
ECG LEADS. introduction The heart produces electrical currents The body acts as a conductor of electricity Electrodes are able to measure the voltages.
ECE 501 Introduction to BME
Presented by- Md. Bashir Uddin Roll: Dept. of BME KUET, Khulna-9203.
Cardiovascular Block Electrocardiogram (ECG)
Medical Applications Electrocardiogram (ECG)
Cardiovascular Monitoring Electrocardiogram
Enhancing the Capabilities of a Wireless Holter Monitor Senan Garry 4 th ECE.
1 ECG Signal Make-up. 2 Biopotential Requirements n High Input Impedance –Minimum loading of the signal being measured –Minimum 10M  n Input circuit.
Waleed Abdel Aziz Salem, PhD. Electrical Department Benha Faculty of Engineering, Benha University E472 E472 Hospital Instrumentation.
Dr. Mona Soliman, MBBS, MSc, PhD Department of Physiology Chair of Cardiovascular Block College of Medicine King Saud University.
Vital Signs Monitor UConn BME 4900 Vital Signs Monitor Purpose As the population ages, many people are required by their doctors to take vital signs.
ECG Monitor Objective o Provide users an economical ECG monitoring device o Raise awareness to the importance of a healthy heart and living o Allow doctors.
Electrocardiography investigation of heart (ECG)..
OBJECTIVE Without reference, identify at least four out of six principles pertaining to the application of transducers related to patient care.
Basic ElectroCardiogram (ECG) Basic ElectroCardiogram (ECG) Prepared by Ms: Alwah M. Alkathiri Mr. Hamza Ratrout Revised by: Dr. Irene Roco.
Electrocardiographs ECG. OUTLINES : Introducing what is meant by Biopotential signals. what is Electrocardiograph (ECG). The conduction system. The standard.
EKG. 4 chambers of the heart- upper called atria and bottom called ventricles Blood pathway through structures of the heart.
ECG Basics Dr. Taj.
ECG Basics.
ECG Workshop Dr Jeremy Wright Cardiologist Hearts1st, Greenslopes Private Hospital.
Electrocardiograph. History Italian scientist Carlo Matteucci realizes that electricity is associated with the heart beat Irish scientist.
Portable Real Time ECG Design
Electrocardiography (ECG) Electrocardiogram  The tracing made by an electrocardiograph  Electrocardiograph an instrument for recording the changes.
Electrocardiography investigation of heart (ECG). Analysis of ECG.
Electrocardiogram Amplifier Design Using Basic Electronic Parts Background Lecture.
Electrocardiogram Amplifier Design Using Basic Electronic Parts
Electromyography E.M.G..
ELECTROCARDIOGRAM(ECG) 演讲 : 颜丽琴 制作 : 张江翔 卢梓伦 陈昊天.
22nd April 2009 ECG Recording and Basic Interpretation.
Electrodes and leads Ten electrodes are used for 12-lead ECG the electrodes usually consist of a conducting gel , embedded in the middle of a self-adhesive.
ELECTROCARDIOGRAM (ECG/EKG)
Biomedical Instruments Design Biopotential Amplifiers
Biomedical Instrumentation
ECG 1.BIPOLAR LEADS I II III 2.UNIPOLAR LIMBS LEADS AVR AVL AVF
Electrical interference
Electrocardiography – Normal 5
Project of Network Analysis
Physiologic signals Lecture 6.
Recording ECG’s.
ECG ECG is a test that displays the electrical activity of heart muscles over a period of time. Detected with the help of electrodes attached to the outer.
Electricity Within the Body
Cardiovascular Block Physiology The Electrocardiogram (ECG)
ELECTRICITY WITHIN THE BODY
Introduction to the E.C.G.
Electromyography E.M.G..
©2012 Lippincott Williams & Wilkins. All rights reserved.
Electromyography E.M.G..
5 The Electrocardiogram.
ECG lead misplacement: A brief review of limb lead misplacement
Amplifiers: A Bio amplifier is an electrophysiological device, a variation of the instrumentation amplifier, used to gather and increase the signal integrity.
Biomedical Instruments Design Biopotential Amplifiers 1.
The Heart and Circulation
A brief introduction to the standard 12-lead ECG (EKG)
ECG – electrocardiography
TOPIC SNSCE/ECE/PRESENTATION /NOV’2016 8/6/2019.
Presentation transcript:

Physiologic signals Lecture (2)

Electrocardiograph The electrocardiograph (ECG) is the recording on the body surface of the electrical activity generated by heart. In order to record an ECG waveform, a differential recording between two points on the body are made. Traditionally, each differential recording is referred to as a lead. A lead is a view of the electrical activity of the heart from a particular angle across the body.

Block diagram of ECG

The ECG is one of the medical equipment that can measure the heart rate, convert it into a signal and present the data on a piece of paper or on a monitor. ECG measurement information is collected by electrodes placed at designated locations on the body. It is the best way to measure and diagnose abnormal rhythms of the heart

The ECG cannot reliably measure the pumping ability of the heart, for which ultrasound-based (echocardiography) or nuclear medicine tests are used. Electro-cardiogram (ECG) is one of frequently used and accurate methods for measuring the heart rate. ECG is an expensive device and its use for the measurement of the heart rate only is not economical. Low-cost devices in the form of wrist watches are also available for the instantaneous measurement of the heart rate.

A. Electrode It converts physical signals into electrical voltage. The voltage is in the range of 1 mV ~ 5 mV. The sensor pair is stuck on the right arm (RA), left arm (LA) and right leg (RL) of the subject.

Wilson Electrode System This system uses the right leg of the patient as “driven right leg lead”. This involves a summing network to obtain the sum of the voltages from all other electrodes and driving amplifier, the output of which is connected to the right leg of the patient Reduces noise interference

B. Instrumentation Amplifier Many industrial and medical applications use instrumentation amplifiers (INAs) to condition small signals in the presence of large common-mode voltages and DC potentials so we choose Analog instrumentation amplifier to amplify the ECG voltage from electrodes, which is in the range of 1mV to 5mV.

An instrumentation amplifier is usually the first stage in an instrumentation system. This is because of the very small voltages usually received from the probes need to be amplified significantly to be proceeding stages. An instrumentation amplifier (IA) is a difference amplifier where the difference between the two input terminals is amplified and the common signals between the inputs are rejected (Common Mode Rejection (CMR)).

C. Low pass filter This block is used to remove the unwanted signals like noise, the frequency range of ECG is 0.04HZ to 150 Hz, and so the low pass filter is designed with the cut off frequency of 150HZ.

ECG leads artifact The heart’s electrical signal is very small and unfortunately this can be combined with other signals of similar frequency to create artifact.

Guidelines that will help reduce artifact when performing ECG’s Patient Positioning: Place the patient in a supine or semi-Fowler’s position. Instruct the patient to place their arms down by their side and to relax their shoulders. Make sure the patient’s legs are uncrossed. Move any electrical devices, such as cell phones, away from the patient as they may interfere with the machine.

Skin Preparation: Dry the skin if it’s moist. Shave any hair that interferes with electrode placement. This will ensure a better electrode contact with the skin. Rub an alcohol prep pad on the skin to remove any oils and help with electrode adhesion.

Electrode Application: Check the electrodes to make sure the gel is still moist. Do not place the electrodes over bones. Do not place the electrodes over areas where there is a lot of muscle movement.

LIMB LEADS Bipolar leads I II III Augment leads Avr Avl Avf

CHEST LEADS 6 UNIPOLAR LEADS V1 V2 V3 V4 V5 V6

Lead groups