Domestic Hot Water Recirculation Design

Slides:



Advertisements
Similar presentations
Hot Water Temperature Maintenance
Advertisements

Unit 206: Domestic hot water systems
DRIP DISPERSAL SYSTEMS Problems and Solutions Presented by Keith Surface.
DRIP DISPERSAL SYSTEMS Problems and Solutions. Flow Equalization Surges in the ATU during peak loading are a major cause of filter clogging in a drip.
Learning Outcomes Upon completion of this training one should be able to: Identify open loop and closed loop campus-type hydronic water system applications.
PUMPING SYSTEMS BASICS
Hot Water Recirculation Pumps. Tim Pehl Outside Sales Rep For Dawson Company. Outside Sales Rep For Dawson Company.
Booster System Basics: Constant Speed Systems
©2007 Armstrong International, Inc. Instantaneous Water Heater Flo-H 2 0 ™ Water to Water Instantaneous Water Heater Flo-H.
Harnessing Free Heat. The Energy Harness provides hot water using multiple heat sources, making the best use of low grade heat. It improves the efficiency.
Pressure Drop Basics & Valve Sizing
© 2012 Rinnai America Corporation Rinnai Circ-Logic (RCL)
DESIGN GUIDE FOR GAS CENTRALISED HOT WATER SYSTEMS
Basic Hydraulics Irrigation.
Piping Systems.
STEAM HEATING.
Hydronic Mechanical Controls
2006 Oct. 19 DES Project -- Vaidas Simaitis, University of Illinois1 DHE – Detector Head Electronics Monsoon 80mm Crate Heat Load.
WATER PIPING DESIGN FOR A RESIDENCE In the packet is a floor plan of a residence with water supply piping shown. Follow the process as a step by step.
Pipe Sizing Sizing Gas Pipe for Low-Pressure Systems
Assignment No. 1 [Grup 8] Figure below shows a portion of a hydraulic circuit. The pressure point B must be 200 psig when the volume flow rate is 60 gal/min.
MECHANICAL ASPECTS OF MICHIGAN UNIFORM ENERGY CODE MIAM DOHERTY INN CLAIRE, MICHIGAN MARK RILEY.
Conservation of Mass, Flow Rates
Water piping design.
Week 1 Unit Conversions Conservation of Mass Ideal Gas Newtonian Fluids, Reynolds No. Pressure Loss in Pipe Flow Week 2 Pressure Loss Examples Flow Measurement.
FEASIBILITY OF COMPONENTS CLARA ECHAVARRIA & JONATHON LOCKE.
For Cardinal Newman Hall Randall Lessard ET Fall 2013 Dr. Cris Koutsougeras Advisors: Dr. Rana Mitra Mr. Byron Patterson.
Important variables Water: Air: Conversion:
NFPA 31 Standard for the installation of Oil- Burning Equipment
1 Medical Office Building. 2 Occupancy – 400 persons 8 a.m. – 5 p.m. Monday - Friday Building Characteristics Three stories 40,000 square feet (200’ x.
Pumps and Lift Stations. Background Fluid Moving Equipment Fluids are moved through flow systems using pumps, fans, blowers, and compressors. Such devices.
TEC 4607 Wind and Hydro Power Technologies Fall 2011.
TEC 4607 Wind and Hydro Power Technologies Fall 2011.
Landscape Irrigation Based upon the book Rain Bird Irrigation Design Manual.
HVACR116 – Trade Skills Longest length method.
Lesson 22 BERNOULLI’S EQUATION
Presentation on Feed and Expansion Cistern. Central Heating At the end of this part you should be able to: Identify general system methods of feed and.
Equation of motion for steady flow with friction and machines (i.e. pumps or turbines ) Recall (Energy per unit weight)
HVACR116 – Trade Skills Pipe Sizing Sizing Gas Pipe for Low-Pressure Systems.
So Far: Mass and Volume Flow Rates Reynolds No., Laminar/Turbulent Pressure Drop in Pipes Flow Measurement, Valves Total Head, Pump Power, NPSH This Week:
Learning Outcomes Upon completion of this training one should be able to: Identify hydronic chilled water system applications. Define the difference between.
Week 1 Unit Conversions Conservation of Mass Ideal Gas Newtonian Fluids, Reynolds No. Pressure Loss in Pipe Flow Week 2 Pressure Loss Examples Flow Measurement.
Introduction to Energy Management
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
1 Hospital Building and Campus Piping. 2 Hospital Building Occupancy – office and patient areas Patient areas: 24 hours per day Office areas: 8 am – 5.
Learning Outcomes Upon completion of this training one should be able to: Identify hydronic chilled water system applications. Define the difference between.
Water Management Water is an important natural resource that requires proper management. Appropriate flow rate, pressure, and water quality are necessary.
Friction Loss Tutorial Used in conjunction with the Friction Loss Check Sheet and any Irrigation Plan.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
LEVEL 3 EXTENDED DIPLOMA MECHANICAL AND ELECTRICAL SERVICES CONSTRUCTION BOILER RECOVERY TIMES.
ME444 ENGINEERING PIPING SYSTEM DESIGN CHAPTER 10A : INDUSTRIAL HOT AND CHILLED WATER UTILITY SYSTEM.
N ATIONAL D IPLOMA M ECHANICAL AND E LECTRICAL S ERVICES C ONSTRUCTION Hot Water Pipe Sizing and Boiler Recovery Times.
EMERGING TECHNOLOGIES AVAILABLE TO REDUCE COMPRESSED AIR DEMAND Double Acting Air Cylinder Double Acting Air Cylinder Air Operated Diaphragm Pumps Air.
Instant hot water. Long-term savings.
Plumbing system fundamental and design course
Improved Hot Water Code Calculation
Design of the thermosiphon Test Facilities 2nd Thermosiphon Workshop
Design of Cold Water Networks
WATER DEMAND (Chapter 24)
HWAT Revival Special focus on hospitals Hygiene Flexibility Economy.
Hot water Systems Heaters.
Pumps and Lift Stations
Hot Water Systems Cylinders and Systems.
Technology in Architecture
Reheat Coil (Typical of 5)
System Curve Example Design Condition 20 ft.w.c. required each way to deliver design flow to and from the headers at the loads Distribution Pump Bell.
Domestic Hot Water Recirculation
Domestic Hot Water Recirculation
Presentation transcript:

Domestic Hot Water Recirculation Design ASPE Washington, DC Chapter November 15, 2016 Robert Evans, CPD, GPD, LEED AP BD&C ASPE Washington, DC Chapter

Domestic Hot Water Recirculation 2012 International Plumbing Code IPC 607.2 Hot or tempered water supply to fixtures. The developed length of hot or tempered water piping, from the source of hot water to the fixtures that require hot or tempered water, shall not exceed 50 feet (15 240 mm). Recirculating system piping and heat-traced piping shall be considered to be the sources of hot or tempered water. 2012 International Green Construction Code 702.8.1 Maximum allowable pipe length method. The maximum allowable pipe length from the source of hot or tempered water to the termination of the fixture supply pipe shall be in accordance with the maximum pipe length columns in Table 702.8.2. Where the length contains more than one size pipe, the largest size shall be used for determining the maximum allowable length of the pipe in Table 702.8.2. ASPE Washington, DC Chapter

Domestic Hot Water Recirculation 702.8.2 Maximum allowable pipe volume method. The water volume in the piping shall be calculated in accordance with Section 702.8.2.1. The maximum volume of hot or tempered water in the piping to public lavatory faucets, metering or nonmetering, shall be 2 ounces (0.06 L). For fixtures other than public lavatory faucets, the maximum volume shall be 64 ounces (1.89 L) for hot or tempered water from a water heater or boiler; and 24 ounces (0.7 L) for hot and tempered water from a circulation loop pipe or an electrically heat-traced pipe. 702.8.2.1 Water volume determination. The volume shall be the sum of the internal volumes of pipe, fittings, valves, meters and manifolds between the source of hot water and the termination of the fixture supply pipe. The volume shall be determined from the liquid ounces per foot column of Table 702.8.2. The volume contained within fixture shutoff valves, flexible water supply connectors to a fixture fitting, or within a fixture fitting shall not be included in the water volume determination. Where hot or tempered water is supplied by a circulation loop pipe or an electrically heat-traced pipe, the volume shall include the portion of the fitting on the source pipe that supplies water to the fixture. ASPE Washington, DC Chapter

Domestic Hot Water Recirculation ASPE Washington, DC Chapter

Domestic Hot Water Recirculation ASHRAE Standard 90.1-2010 7.4.4.2 Temperature Maintenance Controls. Systems designed to maintain usage temperatures in hot-water pipes, such as recirculating hot-water systems or heat trace, shall be equipped with automatic time switches or other controls that can be set to switch off the usage temperature maintenance system during extended periods when hot water is not required. 7.4.4.4 Circulating Pump Controls. When used to maintain storage tank water temperature, recirculating pumps shall be equipped with controls limiting operation to a period from the start of the heating cycle to a maximum of five minutes after the end of the heating cycle. ASPE Washington, DC Chapter

Domestic Hot Water Recirculation 2015 INTERNATIONAL ENERGY CONSERVATION CODE C404.6.1 Circulation systems. Heated-water circulation systems shall be provided with a circulation pump. The system return pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermo-syphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. ASPE Washington, DC Chapter

Domestic Hot Water Recirculation Credit - Jason Hatcher, City of Oakland M&P Inspector ASPE Washington, DC Chapter

Domestic Hot Water Recirculation HEAT LOSS TABLE FOR ½" FIBERGLASS PIPE INSULATION 1/2" COPPER PIPE = 15 BTU/HR 1" COPPER PIPE = 19 BTU/HR 1-1/2" COPPER PIPE = 25 BTU/HR 2" COPPER PIPE = 28 BTU/HR 3" COPPER PIPE = 38 BTU/HR HEAT LOSS TABLE FOR 1" FIBERGLASS PIPE INSULATION 1" COPPER PIPE = 10 BTU/HR 1-1/2" COPPER PIPE = 12 BTU/HR 2" COPPER PIPE = 15 BTU/HR 3" COPPER PIPE = 20 BTU/HR ASPE Washington, DC Chapter

Domestic Hot Water Recirculation ASPE Washington, DC Chapter

Domestic Hot Water Recirculation 1. Calculate piping heat loss using ½" pipe insulation: 3" pipe (77 feet) = 38 X 77 = 2926 BTU/HR 2" pipe (40 feet) = 28 X 40 = 1120 BTU/HR 1-1/2" pipe (140 feet) = 25 X 140 = 3500 BTU/HR 1" pipe (120 feet) = 19 X 120 = 2800 BTU/HR Total heat loss = 9826 BTU/HR ASPE Washington, DC Chapter

Domestic Hot Water Recirculation Calculate piping heat loss using 1" pipe insulation: 3" pipe (77 feet) = 20 X 77 = 1540 BTU/HR 2" pipe (40 feet) = 15 X 40 = 600 BTU/HR 1-1/2" pipe (140 feet) = 12 X 140 = 1680 BTU/HR 1" pipe (120 feet) = 19 X 120 = 1200 BTU/HR Total heat loss = 5020 BTU/HR ASPE Washington, DC Chapter

Domestic Hot Water Recirculation Assume heat loss of return piping is 2/3 heat loss of supply piping. 2/3(9826) = 6544 BTU/HR 2/3(5020) = 3343 BTU/HR Total heat loss is 16370 BTU/HR with ½" insulation, or 8363 BTU/HR with 1" insulation. 2. Allow for temperature drop during circulation (▵T) 20 degree drop - conversion factor is 10000 GPM 10 degree drop - conversion factor is 5000 GPM 5 degree drop - conversion factor is 2500 GPM ASPE Washington, DC Chapter

Domestic Hot Water Recirculation Divide heat loss by conversion factor: 16370/10000 = 1.64 GPM - minimum required circulation rate 3. Determine pump head requirements: A. Select a pump which will operate efficiently at the flow rate calculated - Bell & Gossett model LR-20BF circulator at 1.64 GPM has a discharge head of 12.5 feet. B. Determine the longest run of return piping (approximately 230 feet). This number needs to be converted to equivalent length to account for fittings if they are not added separately. Using 30% for fittings we have a total equivalent length of 299 feet. ASPE Washington, DC Chapter

Domestic Hot Water Recirculation C. Divide pump head by the longest return pipe equivalent length and you will have the uniform friction head. 12.5 feet / 299 = 0.042 D. Multiply by 100 to convert the friction loss to feet per 100 feet. 0.042 X 100 = 4.2 ft/100 ft E. Multiply ft/100 ft by .433 to obtain friction loss in psi/100 ft. 4.2 ft/100 ft X 0.433 = 1.818 PSI/100 ft uniform friction loss. F. Size return piping using 1.818 PSI/100 ft friction loss. ASPE Washington, DC Chapter

Domestic Hot Water Recirculation ASPE Washington, DC Chapter

Domestic Hot Water Recirculation Return to step 1 and recalculate loss for return pipe. Heat loss in the return piping was assumed to be 6544 BTU/HR. Actual heat loss, based on 230 feet of ½" piping is 3450. Adding to the heat loss of the supply pipe (3450 + 9826= 13276 BTU/HR). By step 2 - 13276/10000= 1.328 GPM. The corrected minimum circulation rate is 1.33 GPM (down from 1.64). The head at 1.33 GPM is still approximately 12.5 feet. 5. Completing the same calculation for a 10 degree ▵T shows the uniform friction loss to be 1.69'/100ft. For a 5 degree ▵T, the friction loss is 1.47'/100ft. ASPE Washington, DC Chapter

Domestic Hot Water Recirculation ASPE Washington, DC Chapter

Domestic Hot Water Recirculation Energy conservation for pumps in dollar value What if you can reduce the required horsepower of a pump from 2HP to 1HP, from 1HP to 1/2HP, or from 5HP to 2HP? If you assume an energy cost of 13 cents/kWhr and the pump running 24/7: 1HP = 0.746kW 0.746kW x 24 hr/day x 365 days/year x $0.13/kWhr = $850 per year savings For a reduction of 1HP to 1/2HP – 0.373kW x 24 hr/day x 365 days/year x $0.13/kWhr = $425 per year savings For a reduction of 5HP to 2HP – 2.238kW x 24 hr/day x 365 days/year x $0.13/kWhr = $2,549 per year savings ASPE Washington, DC Chapter