SRI 2007: CLS Optical Metrology Facility- Overview

Slides:



Advertisements
Similar presentations
Chapter 13 Preview Objectives Electromagnetic Waves
Advertisements

Spectral Resolution and Spectrometers
Spectral Resolution and Spectrometers A Brief Guide to Understanding and Obtaining the Proper Resolution of the 785 Raman System.
1 BROOKHAVEN SCIENCE ASSOCIATES NSLS II Metrology R&D Activities Peter Z. Takacs Experimental Facilities Advisory Committee Review 20 Oct 2006.
Precision Displacement Measurement via a Distance Measuring Interferometer (DMI)
1 Laser Beam Coherence Purpose: To determine the frequency separation between the axial modes of a He-Ne Laser All sources of light, including lasers,
Remote sensing in meteorology
Properties of Multilayer Optics An Investigation of Methods of Polarization Analysis for the ICS Experiment at UCLA 8/4/04 Oliver Williams.
Use of a commercial laser tracker for optical alignment James H. Burge, Peng Su, Chunyu Zhao, Tom Zobrist College of Optical Sciences Steward Observatory.
Prepared by Mahmoud F. Elbatta Ahmad Alyazgi Amjad Alaskary Akram abo Twahina Roshdi tambora.
NA62 Gigatracker Working Group Meeting 2 February 2010 Massimiliano Fiorini CERN.
The wave nature of light Interference Diffraction Polarization
Laser interferometer Su-Jin Kim, GNU & Xiaoyu Ding.
D EDICATED S PECTROPHOTOMETER F OR L OCALIZED T RANSMITTANCE A ND R EFLECTANCE M EASUREMENTS Laetitia ABEL-TIBERINI, Frédéric LEMARQUIS, Michel LEQUIME.
Lenses and Mirrors. How does light interact with pinholes? How does light interact with lenses? –___________ How does light interact with mirrors? –___________.
LSC meeting, HLO, August 18, 2004 IAP/UF/LIGO Research Collaboration: Status and Prospectives Efim Khazanov, Ilya Kozhevatov, Anatoly Malshakov, Oleg Palashov,
LASER AND ADVANCES IN METROLOGY
BROOKHAVEN SCIENCE ASSOCIATES BIW ’ 06 Lepton Beam Emittance Instrumentation Igor Pinayev National Synchrotron Light Source BNL, Upton, NY.
Optical surface measurements for very large flat mirrors Jim Burge, Peng Su, and Chunyu Zhao College of Optical Sciences University of Arizona Julius Yellowhair.
Simulations of the double funnel construction for LET. Comparison with a single funnel The aim was to optimise the double funnel configuration to give.
DECam Daily Flatfield Calibration DECam calibration workshop, TAMU April 20 th, 2009 Jean-Philippe Rheault, Texas A&M University.
1 BROOKHAVEN SCIENCE ASSOCIATES Mirror Metrology and Development Strategy Q. Shen, K. Kaznatcheev, A. Fluerasu Experimental Facilities Division NSLS-II.
DIFFRACTION AND INTERFERENCE. Specification Topics Interference The concept of path difference and coherence The laser as a source of coherent monochromatic.
Our Operating Funding Partners Recent Design Improvements to the Canadian Light Source (CLS) Optical Metrology Facility Long Trace Profilometer.
10/2007 M.Taborelli, TS-MME M.Taborelli Structure fabrication: dimensional tolerances Contributions of : G.Arnau-Izquierdo, A.Cherif, D.Glaude, R.Leuxe,
1 BROOKHAVEN SCIENCE ASSOCIATES Lonny Berman EFAC May 10 th 2007 ID Beamline Optics and Damping Wigglers.
© Houghton Mifflin Harcourt Publishing Company Preview Objectives Electromagnetic Waves Chapter 13 Section 1 Characteristics of Light.
1 BROOKHAVEN SCIENCE ASSOCIATES A Wiggler Beamline for XAS at NSLS-II Paul Northrup NSLS-II Project and Environmental Sciences Department Brookhaven National.
Optic Measurement Analysis and Visualization using ROOT as a General Framework Dylan Maxwell Optical Metrology Lab Canadian Light Source, Inc. University.
Electro-optical systems Sensor Resolution
Copyright © 2009 Pearson Education, Inc. Chapter 35-Diffraction.
Interference of Light Ø It is generally He-Ne type that generates stable coherent light beam of two frequencies. one polarized vertically and another.
Ultra High Precision X-ray Telescope Project (X-mas Project) S. Kitamoto, T. Kohmura, N. Yamamoto, H. Saito, H. Takano, H. Sekiguchi, K. Suga (Rikkyo Univ.)
Chapter 2: Viewing the Microbial World
Section 1 Characteristics of Light
VERTICAL SCANNING INTERFEROMETRY VSI
1.Dimension measurement for calibration duties.
David Urner Oxford University/JAI
Mirrors and Lenses.
Chapter 35-Diffraction Chapter 35 opener. Parallel coherent light from a laser, which acts as nearly a point source, illuminates these shears. Instead.
SPARCLAB: PW-class Ti:Sa laser+SPARC
Reflection & Mirrors.
l 66TH MEETING OF THE ESRF l May 2014 l Author
Index of Refraction.
Manuel Marchiò, Raffaele Flaminio, Shunshi Kuroki
INTERFERENCE.
TRIVIA QUESTION! How big (diameter of largest reflective mirror) is the LARGEST telescope in the world? (a) (b) (c ) (d) 34 feet (e) Telescope, Location,
Digital Processing Techniques for Transmission Electron Microscope Images of Combustion-generated Soot Bing Hu and Jiangang Lu Department of Civil and.
RADAR -Range and Bearing Discrimination and Accuracy.
PRESENTATION ON MEASUREMENT AND GAUGING
Mirrors and Lenses Images can be formed by reflection from mirrors.
Day 32 Range Sensor Models 11/13/2018.
Image Formed by a Flat Mirror
Phys102 Lecture 21/22 Light: Reflection and Refraction
First Assessments of EUVI Performance on STEREO SECCHI
Chapter 35-Diffraction Chapter 35 opener. Parallel coherent light from a laser, which acts as nearly a point source, illuminates these shears. Instead.
Instrument Considerations
Chapter 33 Continued Properties of Light Law of Reflection
Interference Introduction to Optics Coherent source
Chapter 34—Ray Optics Items covered in this chapter: Reflections
Distance Sensor Models
Fraunhofer Diffraction
Chapter 33 – Wave Optics Topics that we will cover:
Review calculation of Fresnel zones
LightGage™ Frequency Scanning Technology
Text Reference: Chapter 32.1 through 32.2
Remote sensing in meteorology
DIFFRACTION AND INTERFERENCE
Mirrors Chapter
Presentation transcript:

SRI 2007: CLS Optical Metrology Facility- Overview Brian Yates1, Dylan Maxwell1 1 Canadian Light Source Inc., 101 Perimeter Road, Saskatoon, SK S7N 0X4, Canada Canadian Light Source Metrology Facility Overview: The CLS Optical Metrology Facility performs beamline ray-tracing/modeling and determines the quality of the optical components that are installed in the CLS beamlines. This requires measurement of a variety of mirror parameters, to ensure compliance by the vendor to CLS specifications. Typical mirror parameters are surface roughness, calibration of radius of curvature, and figure slope error. Measurements from three distinct instruments are typically taken to characterize the quality of optical components. The three instruments are the Ocean Optics Long Trace Profilometer (LTP), the Zygo Verifire AT Fizeau Interferometer (FI), and the Micromap 570 Interferometric Microscope (IM). The LTP directly measures the slope along a single line on the optical surface. The radius of curvature and slope error is then calculated from this slope profile, which has a spatial period range of approximately 2 mm to the length of the surface. Typically three tangential and three sagittal slope profiles are acquired for a complete measurement of an optical surface. The FI measures the height map of the optical surface component. The radius of curvature and slope error can then be calculated from this surface height map, which has a spatial period range of approximately 1 mm to the length and width of the surface. One measurement is sufficient to characterize the entire surface, but typically at least three measurements are acquired for error analysis purposes. The IM measures the height of the optical surface over an approximately one millimetre square field‑of‑view. The surface roughness can then be calculated from this surface height map, which has a spatial period range of approximately 1µm to the length and width of the field of view. For extremely smooth surfaces, three measurements are required at each sample location, and several locations must be sampled on the optical surface in order to be fully characterized. Therefore, a single optical component that is fully characterized in the Optical Metrology Facility produces a significant number of data sets, in different formats, requiring analysis and summarization. Facility and Instrumentation Capabilities 1. Class 10,000 Clean Room (± 0.1 degree Celsius temperature stability) - All metrology instruments mounted on vibration isolation tables (TMC) to minimize the effects of vibration. 2. 3D surface profiler (IM) from Micromap - Measures surface roughness. 3. Long Trace Profilometer (LTP) from Ocean Optics - Measures figure “slope error” and radius of curvature. 4. Fizeau Interferometer (FI) from Zygo - Measures figure “slope error” and radius of curvature using radius bench measurement and distance measurement interferometer (DMI). The role of the optical metrology facility is to determine the figure and finish of mirror, crystal and diffraction grating surfaces, to ensure proper spot sizes at the beamline experimental stations. Figure, finish and mirror coating determines the photon flux and photon energy range delivered to the beamline experimental station. The optical metrology facility instruments are used to determine actual height and slope profiles of these optical mirror surfaces that are used in x-ray, visible light, and infrared synchrotron beamlines. The instrument measurement ranges often overlap, giving greater confidence in each of the measurements. Removal of the figure curvature (e.g. spherical, cylindrical) from the surface height map or slope map yields the slope error. A large slope error will result in an undesirable experimental focus, where photon flux, brightness and spot size have been compromised. Instrument Horizontal Spatial Period Range Vertical Dynamic Range Approximate Measurement Limit 3D Surface Profiler (Micromap 570) (0.0002 – 1.25) mm (0.010 – 150000) nm 0.03 nm RMS Height Long Trace Profilometer (LTP) (Ocean Optics) (2 – 1500) mm (0.014 – 10000) µrad 10 nm RMS Height 0.45 µrad RMS Slope Error Fizeau Interferometer (Zygo Verifire AT) (0.039 – 150) mm (normal) (0.39 - 1500) mm (grazing) (5 – 1000) nm 20 nm RMS Height 0.45 µrad RMS Slope Error 3D surface profiler (Micromap 570) Long Trace Profilometer (Ocean Optics) Fizeau Interferometer (Zygo VeriFire AT) 3D Surface Profiler (Micromap 570) The Micromap 570 3D surface profiler (shown to the far left) is a microscope-based instrument that utilizes visible light interferometry to measure the surface finish (i.e. surface roughness) of reflective optical surfaces. A CCD detector mounted on the microscope is used to measure an area (on the order of ~ 1 x 1 mm2, which is dependent on the microscope objective used) with a height resolution of approximately 0.03 nm. Four different objectives are currently available: 5X, 10X, 20X, and 50X, which enable us to cover a wide range of spatial periods (0.0002 - 1.25) mm or spatial frequencies (0.0004 - 2.5) µm-1. Three measurement modes are available in software – smooth phase mode (interferometry phase measurement), wave mode (white light interferometry phase scan) and focus mode (interferometry focus scan). Smooth phase mode is ideal for very smooth surfaces (0.02 – 100) nm Sq roughness, but is limited to a maximum height measurement of 4 µm (focus depth). Wave mode is ideal for smooth surfaces with heights and steps <5 µm. Focus mode is ideal for rough surface textures and real surface heights >5 mm (maximum height measurement is 150 µm). 3D surface profile of a smooth mirror, taken using a 10X objective with the Micromap 570 in “smooth phase” mode, using filtered white light (550 nm with a 25 nm filter bandwidth). The image represents approximately 0.5 x 0.5 mm2 of the mirror. Long Trace Profilometer (LTP) (Ocean Optics) The Long Trace Profilometer (LTP) from Ocean Optics (shown to the far left) measures the slope and curvature of mirror surfaces along one dimension using a zero-path difference interferometer. A solid state HeNe laser source is used to probe the mirror under test. The CLS LTP can measure optical surfaces up to 1.5 meters in length, covering the range of spatial periods from (2 – 1500) mm or spatial frequencies of (0.00033 – 0.25) mm-1. Surfaces of virtually any shape can be measured in situ, as long as the surface slope change is within the ± 5 milliradian acceptance angle of the LTP optical system, with a sensitivity of 0.1 µrad and 10 nm in height. Dr. Peter Takacs and staff developed the LTP at Brookhaven National Laboratory (BNL). The instrument is mounted on a vibration isolation table to minimize the effects from external vibrations, and shrouded in a plastic curtain normally while measurements are taken (not shown in photograph to the far left), in order to reduce air turbulence effects on the optical head. The bearing has recently been upgraded from a crossed-roller bearing to a more precise linear air bearing. A further upgrade is planned in the near future to an even flatter ceramic beam. Height profile of a “reference” spherical mirror – the edges are raised ~20 µm. collimated HeNe laser beam (l=632.8 nm, 150 mm diameter) Fizeau Interferometer (Zygo Corp.) The Zygo VeriFire AT Fizeau interferometer (shown to the far left) measures the height deviation of an optic under test from a reference surface. It accomplishes this using phase shifting interferometry. The figure error of optical surfaces up to 150 mm in diameter at normal incidence, or larger optics at grazing incidence angle (<1500 mm), can be measured with this instrument. A picture of a grazing incidence measurement, in double pass mode is shown to the left (middle position). A collimated HeNe laser beam (l=632.8 nm, 150 mm diameter) is output from the Fizeau Interferometer through a reference transmission flat (left), reflected off the mirror under test (right) and then reflected back with a return flat (top right) to the detector in the interferometer. Double pass refers to the fact that the collimated beam is reflected twice off the test mirror. Return flat Mirror under test Transmission Flat Fizeau Interferometer 3D height profile of a transmission flat, measured in “single pass” normal incidence mode. 45° Grazing incidence measurement, in so-called “double pass” mode. Radius bench measurement/DMI Laser