Point-of-Care Testing (POCT) Staff Training

Slides:



Advertisements
Similar presentations
baptist bhsala.com Student Teaching Module PXP 2014.
Advertisements

Glucose, Whole Blood Accu-Chek Inform II®
The ACCU-CHEK Inform system Training Guide
Learning Objectives Collect Dried Blood Spots (DBS) for HIV testing
Finger stick blood collection into Microtainer®. Universal precautions Assume that all human blood is potentially infectious for HIV, hepatitis, and other.
A Quality Improvement and Patient Safety project for Kaleida Health April 2010.
DBS preparation from finger stick blood in Microtainer®
Fingerstick Procedure
1 USDOC41 Rev 0 1/04 Training and Education Program ©2004 HemoCue, Inc. HemoCue ® Training and Education Program The HemoCue Hb System.
Kakuma Nutrition Survey November 2012 Training Day 4.
Medication Assistant Training Module 5 Eyes Ears Nose.
StatSensor® Creatinine Operator Training Program
Nova Stat Strip Update.
Blood Glucose Measuring Prepared By: Dr. Manal Moussa Ibrahim.
Optional, EMT. Course Objectives Indications for Use Proper Technique Pitfalls and Troubleshooting.
Module 2: Testing Controls and Patients
At the Bedside.
Methodologies and Regulations in Specimen Collection and Management
Blood Glucose Measuring Devices in the Pre-hospital Setting.
Kaleida Health Point of Care Glucometer Testing 2011
Nova Stat Strip Update.
XceedPro Meter BEDSIDE GLUCOSE The following slides include a review in preparation for completion of the Bedside glucose recert quiz and performance of.
GLUCOSE TESTING USING THE TRUEtrack GLUCOMETER
Fingerstick Blood Collection into a Microtainer for PNG
Accu-Chek Inform II Blood Glucose Monitoring System.
Patient Identification & Specimen Collection How Proper Patient Identification and Proper Specimen Collection Affects the Accuracy of Your Patient’s Laboratory.
Administration of Vaccine via Intramuscular Route
Module 8: Blood Collection and Handling Dried Blood Spot
CLS 424 Phlebotomy Student Lab Rotation
Smallpox Vaccine Administration  Learning Objectives Demonstrate appropriate vaccine administration techniques Demonstrate appropriate vaccine administration.
ACCU-CHEK Inform II Operator Training
Diabetes Mellitus Disorder that affects the body’s ability to use glucose –the cells in the pancreas that secrete insulin, do not secrete enough insulin.
Chapter 28 Collecting and Testing Specimens All items and derived items © 2015, 2011 by Mosby, Inc., an imprint of Elsevier Inc. All rights reserved.
Welcome to PRMCE POINT OF CARE (POC) TESTING Orientation.
Accu-Chek® Inform II. Outline Policies Procedure, equipment and supplies Liquid quality control Patient testing Reporting results: What do my results.
ACCU-CHEK Inform II Operator Training Provincial Health Services Authority ACCU-CHEK, ACCU-CHEK INFORM, ACCU-CHEK PERFORMA and COBAS are trademarks of.
Collection of blood samples Dr Khaled Mahran.
L’Docile GERMANY Island Gate © 2014 Blood Glucose Monitoring System Blood Glucose Monitoring System.
SAFETY. General Safety FFFFreedom from harm or danger.
Basics of Medical Equipment Lecture 5
Nova StatStrip Glucose Meter Training for glucometer operators
Sierra – Sacramento Valley EMS Agency
Freestyle Precision Pro
Assisting with the Nursing Process
Mount Auburn Hospital Required
Oral Glucose Tolerance Test
NON- PHARMACOLOGICAL TREATMENT METHODS
Venous Blood Collection
SAFETY IN THE LAB.
StatSensor® Creatinine Operator Training Program
(please view in slide mode)
1-800-DIABETES DIABETES CARE TASKS AT SCHOOL: What Key Personnel Need to Know DIABETES CARE TASKS AT SCHOOL: What Key Personnel Need to.
ABOUT THIS PRESENTATION For Instructor Use Only
Drawing Blood And Collecting Diagnostic Samples. 1. Performing Blood Draws / Heel sticks 2. Labeling Specimens 3. Blood Bank Collections 4. Performing.
Miami Dade County Public Schools
Point-of-Care Testing (POCT) Staff Training
Home Use Fingerstick Technique Training
CAPILLARY BLOOD COLLECTION PROCEDURE
PTS Detect™ Cotinine System Training
ACCU-CHEK Inform Glucose Meter
POCT Glucose Accu-Chek Inform II
Lab Safety Rules GENERAL GUIDELINES
Sterile Technique.
SAFETY IN THE LAB.
HIV-1 Rapid Test for Recent Infection
13 Vital Signs and Monitoring Devices.
Bedside glucose XceedPro Meter
Bedside glucose XceedPro Meter
HIV-1 Rapid Test for Recent Infection
GLUCOSE TESTING USING THE TRUEtrack GLUCOMETER
Presentation transcript:

Point-of-Care Testing (POCT) Staff Training Glucose Point-of-Care Testing (POCT) Staff Training

Glucose Meter At this time Abbott PCx glucose meter is being used.

Limitations Results may be falsely decreased in patients with excessive water loss or dehydration, shock, or hyperglycemic-hyperosmolar state. Never test body fluids, serum or plasma. High hematocrits (above 70%) can cause erroneously lower results and low hematocrits (below 20%) can cause falsely elevated results. Testing in an environment with a temperature between 15°C (59°F) and 40°C (104°F) and a relative humidity between 10% and 90%.

Always Identify the patient Per Hospital policy all patients must be identified with two identifiers: “ All inpatients must be positively identified from the time the Hospital assumes responsibility for their care until discharge…..The identification band must remain physically attached to the patient at all times” . “All inpatients must be identified by an approved armband containing the patient’s name, account number, birthdate and medical record number.” “patients in outpatient settings will be identified with two identifiers, the patient name and date of birth”.

What is an Operator ID? Your Mad River Hospital Unique ID is your Operator ID and is used to identify you as the person performing a glucose test. Scan the barcode on the back of your badge. If your ID comes up “Invalid Operator” call the POCT coordinator at 3204.

Would you let someone borrow your credit card or Social Security number? This is why you never allow anyone to use your badge. If a co-worker’s badge does not work, there is a valid reason and they should address this with the POCT coordinator. Remember you are legally responsible for all tests performed using your ID. Your name is tied to every glucose test performed using your ID. It is a work rule violation (can be grounds for dismissal).

Procedure: Scan barcode on the back of your badge. Select either “Control Test” or “Patient Test”.

Check the expiration of Quality Control (QC). Expires 90 days from date opened or manufacturers outdate, whichever comes first. If expired discard, open and date new set. Scan barcode on bottle. QC must be performed every 24 hours. Meters have QC lockout.

Scan the barcode on the test strip.

Patient testing Press “Patient Testing” and follow the prompts, Remember to SCAN patients armband.

Attached Armbands should always be used! Per hospital policy: “No hospital employee is to perform any test or procedure or transport any patient when an armband is missing or defaced” . NEVER USE ARMBANDS NOT ATTACHED TO PATIENT…. Found laying in the patient’s room, Taped to the bed, Found in chart Or at the nursing station Barcoded labels laying around Who does the armband belong to?

Choose the finger carefully Best locations for a finger stick is the 3rd and 4th fingers of the non-dominant hand. Avoid the 2nd and 5th fingers if possible. Perform the stick off to side of the center of the finger. NEVER use the tip or center of the finger.

Massage or Warm the site Avoid fingers that are cold, cyanotic, swollen, scarred or covered with a rash. Massage to warm the finger and increase blood flow by gently squeezing from hand to fingertip 5-6 times.

Clean and DRY the site Cleanse fingertip with 70% isopropyl alcohol scrub vigorously. Allow alcohol to dry thoroughly before testing. Do not fan, blow on or wipe off. Caution: Alcohol can falsely elevate or lower blood glucose results.

Finger Stick location Using a sterile lancet, make a skin puncture just off the center of the finger pad. Wipe away the first drop of blood (which tends to contain excess tissue fluid).

Do not milk finger If necessary, apply light pressure to the surrounding tissue until another drop of blood appears. Avoid "milking". The drop of blood must be big enough to fill the strip completely. NOTE: Do NOT squeeze or apply strong repetitive pressure to the site. This may result in hemolysis or increase tissue fluid in the blood causing incorrect glucose results. Caution: Free flowing blood is necessary to obtain reliable results. Increased pressure beyond that necessary to hold the finger can result in inaccurate results.

Opening the strip At the notch in the strip, Hold the strip on each side of the notch, Hold the top half still, while pulling the bottom half toward you. While pulling the bottom foil away, Hold the strip with the electrodes out,

Place strip into meter. Apply sample to the target area of the strip.

Error Messages “Laser On Time Exceeds”: This means the laser has overheated. Clean the laser cover with a soft, dry cloth and allow meter to cool for 15 minutes. Code 113 or 115: send a sample to the lab, something is causing an interference.

Alert Values Alert Values: <40 or >400 mg/dL Alert Valves must be confirmed by repeating the test. Any values <40 or >400 MUST be confirmed by laboratory testing.

Where to find information Information can be found in the lid of the carrying case. Glucometer user manual can be found on the Intranet

Testing yourself or Co-Workers It is a work rule violation to test yourself or co-workers. Exception to this is an emergency, the person will need to go to Employee Health or the Emergency Room.

Remember: Scanning is everything Scanning prevents manual entry errors and results going to the wrong patient chart. If you must manually enter a number, double check it before you press the enter button. This should be a rare issue unless you work in the outpatient areas. Use the patient’s Account number as the identification.

5150 This number is used exclusively in OB and ER for trauma or emergency cases where an armband is not available. Patient identification must be documented on the 5150 log located in these departments.

Always keep the meter flat when running a test This prevents solutions from running into the port and damaging the meter.

If you have problems with your meter call the POCT coordinator at 3204.

Cleaning the Glucometer The glucometer must be cleaned before each patient test, after each patient test and every 24 hours they have not been used for patient testing. Glucometers must be cleaned with PDI germicidal Super Sani Cloth disposable wipe. Pay special attention to the end of the glucometer with the test strip port and any areas of obvious blood contamination