Group refractive index ● Method ● Additional runs ● Wavelength distribution ● Systematics ● Results.

Slides:



Advertisements
Similar presentations
Unit-2 Polarization and Dispersion
Advertisements

2003/04/071 Characteristic of 850-nm InGaAs/AlGaAs Vertical-Cavity Surface-Emitting Lasers Master’s thesis of Yuni Chang Speaker:Han-Yi Chu National Changhua.
LED SYSTEMATICS IN TRANSMISSION LENGTH MEASUREMENTS Harold Yepes-Ramirez 15/11/2011.
Light Waves and Polarization Xavier Fernando Ryerson Communications Lab
S Digital Communication Systems Fiber-optic Communications - Supplementary.
Chromatic Dispersion Measurement methods  Pulse Delay Method (time-of-flight) ‏ IEC / ITU-T G650.1 EIA/TIA-455- FOTP-175-B  Phase Shift Method.
Jin Huang & Vincent Sulkosky Massachusetts Institute of Technology Boson 2010 Workshop Sept 20, JLab.
Components of Optical Instruments or What’s inside that spectrometer?
Ciro Bigongiari. Schematic View 17/05/2011Ciro Bigongiari 2 Photon Path Optical Beacon Optical Module Sea water.
PROGRESS ON WATER PROPERTIES ON TRACKS RECONSTRUCTION Harold Yepes-Ramirez 17/11/2011.
PROGRESS ON WATER PROPERTIES ON TRACKS RECONSTRUCTION Harold Yepes-Ramirez 09/11/2011.
Pulsed Cathodic Arc Plasma Diagnostics Optical Emission Spectroscopy Results Aluminium.
Spectral analysis of starlight can tell us about: composition (by matching spectra). temperature (compare to blackbody curve). (line-of-sight) velocity.
H Yepes, C Bigongiari, J Zuñiga, JdD Zornoza IFIC (CSIC - Universidad de Valencia) NEWS ON ABSORPTION LENGTH MEASUREMENT WITH THE OB SYSTEM ANTARES COLLABORATION.
PERFORMANCE OF THE DELPHI REFRACTOMETER IN MONITORING THE RICH RADIATORS A. Filippas 1, E. Fokitis 1, S. Maltezos 1, K. Patrinos 1, and M. Davenport 2.
AN UPDATE ON ABSORPTION LENGTH MEASUREMENT WITH THE OB SYSTEM ANTARES Collaboration Meeting Paris (France), September 20th-24th H Yepes, J Barrios IFIC.
In this event 240 eV electron is passing through the MICE Cerenkov detector.
H Yepes, C Bigongiari, J Zuñiga, JdD Zornoza IFIC (CSIC - Universidad de Valencia) STATUS OF THE ABSORPTION LENGTH MEASUREMENT WITH THE OB SYSTEM ANTARES.
DATA TAKING – TESTS OF ABSORPTION LENGTH MEASUREMENTS IN ANTARES MC (group meeting) HAROLD YEPES-RAMIREZ IFIC, 22/10/10 1.
Study of optical properties of aerogel
STATUS OF THE ABSORPTION LENGTH MEASUREMENT ANTARES collaboration meeting Clermont-Ferrand (France), May 17th-20th 1 H Yepes, JdD Zornoza, J Zuñiga, C.
AN UPDATE ON ABSORPTION LENGTH MEASUREMENT WITH THE OB SYSTEM ANTARES Collaboration Meeting Paris (France), September 20th-24th H Yepes, J Barrios IFIC.
1 Fiber Optics FIBER PERFORMANCE. 2 Fiber Optics The purity of optical fiber is critical for the best transmission of an optical signal inside a fiber.
The ANTARES experiment is currently the largest underwater neutrino telescope and is taking high quality data since Sea water is used as the detection.
Coincidence analysis in ANTARES: Potassium-40 and muons  Brief overview of ANTARES experiment  Potassium-40 calibration technique  Adjacent floor coincidences.
TRANSMISSION LENGTH STATUS HAROLD YEPES-RAMIREZ IFIC, December 16 th
The see through body A BRIEF INTRODUCTION BY: ABEL RUIZ.
The aerogel radiator: optical characterization and performances L.L. Pappalardo INFN - University of Ferrara 1 CLAS12 RICH Review – JLab - September 5-6.
Status of gravitational lens paper Internal note: Results of the optical properties of sea water in the ANTARES site with the OB system.
Backscattering Lab Julia Uitz Pauline Stephen Wayne Slade Eric Rehm.
CMS ECAL Laser Monitoring System Christopher S. Rogan, California Institute of Technology, on behalf of the CMS ECAL Group High-resolution, high-granularity.
KM3NeT Pylos meeting, April, 2007 Some preliminary studies for the positioning calibration of KM3NeT Miguel Ardid Universitat Politècnica de València.
Background Subtraction and Likelihood Method of Analysis: First Attempt Jose Benitez 6/26/2006.
Detection of electromagnetic showers along muon tracks Salvatore Mangano (IFIC)
Time Calibration with Optical Beacons Pylos, Apr 2007 C.Bigongiari IFIC Pylos, Apr 2007 C.Bigongiari IFIC (CSIC – Universitat de València)
Ciro Bigongiari, Salvatore Mangano Results of the optical properties of sea water with the OB system.
SOL Review Algebra I.
PMT Calibration R.Sawada 7/Jan/2007. Time calibration Method was talked at the previous meeting. The problems which was shown before were because I used.
Time and amplitude calibration of the Baikal-GVD neutrino telescope Vladimir Aynutdinov, Bair Shaybonov for Baikal collaboration S Vladimir Aynutdinov,
Calibration of energies at the photon collider Valery Telnov Budker INP, Novosibirsk TILC09, Tsukuba April 18, 2009.
Calibration of Under Water Neutrino Telescope ANTARES Garabed HALLADJIAN October 15 th, 2008 GDR Neutrino, CPPM, Marseille.
1 Ciro Bigongiari, Salvatore Mangano Results of the optical properties of sea water with the OB system.
Ciro Bigongiari, Salvatore Mangano, Results of the optical properties of sea water with the OB system.
Photon Transport Monte Carlo September 27, 2004 Matthew Jones/Riei IshizikiPurdue University Overview Physical processes PMT and electronics response Some.
Micro-structural size properties of Saturn’s rings determined from ultraviolet measurements made by the Cassini Ultraviolet Imaging Spectrograph Todd Bradley.
Signal Propagation Basics
Date of download: 7/6/2016 Copyright © 2016 SPIE. All rights reserved. (a) Responsivity phantom. (b) Setup to measure the diffuse transmittance factor.
Optical calibration from ten to hundreds of meters for the Neutrino Burst Experiment (a poor man’s Km 3 underwater neutrino telescope) NESTOR/NOA Spyridon.
Measurement of the group refractive index in the ANTARES site with the Optical Beacons at 3 wavelengths ● Introduction ● Method ● Measurement with Monte.
Velocity of light in water
A. Checks to run to make sure the instrument is in good working condition: Absorbance optics: ● run an intensity wavelength scan on an empty hole at 5.9.
Michele Faucci Giannelli
Light velocity at new wavelengths
Comparison between Aasim and Calibob
Four wave mixing in submicron waveguides
Velocity of light in water
Review: Laws of Reflection and Refraction
Measurement of water optical properties in ANTARES
Charles F. Maguire Vanderbilt University
The Doppler Effect Tyler Cash.
Digital Processing Techniques for Transmission Electron Microscope Images of Combustion-generated Soot Bing Hu and Jiangang Lu Department of Civil and.
Lecture 2b Beer’s Lambert Law.
Measuring the Speed of Light!
on behalf of the NEMO Collaboration
NanoBPM Status and Multibunch Mark Slater, Cambridge University
COMMUNICATION ENG. PROF. A.M.ALLAM
Spectral analysis of starlight can tell us about:
Christopher Deufel, Michelle D. Wang  Biophysical Journal 
Nanobeacon: A low cost calibration instrument for KM3NeT
Presentation transcript:

Group refractive index ● Method ● Additional runs ● Wavelength distribution ● Systematics ● Results

Method Optical Beacon run: Flash light from a given position Measure time when light reaches PMT => velocity of light in water and refractive index Advantage of light from Optical Beacons: Small light dispersion, because of small wavelength range (around 10 nm) Light emitted at wavelength (red new data) 385, 400, 440, 460, 470, 505, 518 and 532 nm

Method: Times versus distances Fit linear function => v_measured n=v_vacuum/v_measured Each position has up to three measurements with errors in position of 0.2 m and time with 0.2 ns

Additional runs Old runs (69 runs taken between 2008 and 2010) : Light emitted at wavelength 400, 470 and 532 nm New runs (8 times 6 runs taken between 2010 and 2011) Light emitted at wavelength 385, 400, 440, 470, 505, 518 nm Laser runs taken at similar period 532 nm Calibration used 2010:V6.5 for new analysis

Old measurements Data at 470 nm (42 runs)

New Measurements Data at 400 nm (8 runs)Data at 505 nm (8 runs) Similar for other wavelengths

Absorption length distribution Use absorption length distribution: 1) to correct for wavelength distribution at given distance 2) uncertainty for systematics Input: Wavelength distribution at emission place (distribution from spectrometer) Take into account absorption Output: Wavelength distribution at detection place (shifted distribution used in public plot)

Change of wavelength distribution through absorption 385 nm Laser 532 nm 460 nm Light curve emitted Expected light curve at 120 meters Drastic change Wavelength distribution used for final plot

Evolution of wavelength peak values as function of distance Most wavelength with small changes Largest change for 518 nm 518 nm at 0 m 490 nm at 120 m Width of wavelength distribution also change (not shown for clarity) Analysis range between 100 m and 250 m

Scattering as function of wavelength Sea campaign of the year 2000 suggests to take for all wavelength a minimum scattering value of 20 m and a maximum scattering value given by the value used in ANTARES Higher limit given by Mobley Lower limit given by Mobley Used in Antares Lower value used for systematics

MC checks with three different refraction indexes (no scattering) Method gives reliable results

MC with three different refraction indexes (default values) Variation between input refraction index and measured refraction index (< 0.3%) Variation depends more on scattering length than absorption length

MC with different scattering lengths 0.2% Shorter scattering length -> larger measured refraction index 0.3% 0.2% Variation

Comparison of parametric formula and measurement Errors for refraction index => 0.3% (scattering) Errors for wavelength distribution from absorption corrections

Conclusion ● Runs analyzed from 2008 until 2011 ● Absorption changes the measured wavelength distribution => apply corrections for final plot ● Systematics ● Parametric formula and data agrees ● Paper draft soon ready