Efficiency, Dark noise, and Baseline fluctuations with Burle-Photonis MCP-PMT's Jean-Francois Genat and Edward May Dec 2009 –Jan 2010.

Slides:



Advertisements
Similar presentations
Bandwidths of Transmission Line Anodes Jean-Francois GENAT LPNHE Paris LAPPD Workshop, Chicago, April 26th 2011.
Advertisements

Picosecond Timing with Micro-Channel Plate Detectors Jean-Francois Genat Fast Timing Workshop Lyon, Oct 15 th 2008.
The Factors that Limit Time Resolution in Photodetectors, Workshop, University of Chicago, April 2011 What is known experimentally about timing determinants.
Photodetector Timing Resolution Burle Micro-Channel Plate Photo Multiplier Tubes (MCP-PMTs) H. Wells Wulsin SLAC Group B Winter 2005.
Microchannel Plates signals, Picosecond timing, Design’s minimum performance.
D. Peterson, “The Cornell/Purdue TPC”, LCWS05, Stanford, 21-March The Cornell/Purdue TPC Information available at the web site:
1 A Design of PET detector using Microchannel Plate PMT with Transmission Line Readout Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat.
Discussion of Proposed mini-TimeCube UH Team: Michelle Alderman, Steve Dye, John Learned, Shige Matsuno, Marc Rosen, Michinari Sakai, Stefanie Smith, Gary.
Large Area, High Speed Photo-detectors Readout Jean-Francois Genat + On behalf and with the help of Herve Grabas +, Samuel Meehan +, Eric Oberla +, Fukun.
A few numbers. kT/C noise: limits the dynamic range Sampling capacitor: 60 fF (seen by the switch, post-layout) kT/C = sqrt( * 300K * 60fF)
Development of Picosecond-Resolution Large-Area Time-of-Flight Systems C. Ertley 2, J. Anderson 1, K.Byrum 1, G.Drake 1, H.Frisch 2, J. Genat 2, H. Sanders.
The UC Simulation of Picosecond Detectors Pico-Sec Timing Hardware Workshop November 18, 2005 Timothy Credo.
P. Karchin – PMTs for Scintillator Based Muon Systempage 11/7/2004 January 7, 2004 American Linear Collider Physics Group 2004 Workshop Stanford Linear.
Design and test of a high-speed beam monitor for hardon therapy H. Pernegger on behalf of Erich Griesmayer Fachhochschule Wr. Neustadt/Fotec Austria (H.
Fast sampling for Picosecond timing Jean-François Genat EFI Chicago, Dec th 2007.
Novel approach for calibration breakdown voltage of large area SiPM
Tests of a 10cm by 10cm triple GEM detector
Time over Threshold Electronics for Neutrino Telescopy George Bourlis + multiplicity.
10 Picosecond Timing Workshop 28 April PLANACON MCP-PMT for use in Ultra-High Speed Applications.
SCH: LEADE LPM+AG 15/12/031 Non intercepting diagnostics based on synchrotron light from a bending magnet (started as “piggy back” on transverse profile.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
Signal Processing for Fast Photo-detectors Jean-François Genat With the help of: Mircea Bogdan, Henry Frisch, Eric Oberla, Fukun Tang U Chicago.
Evaluation of Silicon Photomultiplier Arrays for the GlueX Barrel Calorimeter Carl Zorn Radiation Detector & Medical Imaging Group Jefferson Laboratory,
Tray Factory Considerations Jean-Francois Genat UC LAPD Collaboration Meeting, June th 2010, Argonne. 1.
A DIRC for GlueX April 7, 2006 S. Berridge, S. Spanier.
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
O. Siegmund1 MCP #168/167 Tests Light transmission #168Photo #168 #168 and #167 have been used as a pair with a biasable gap of 0.6mm. Visually they have.
Introducing gigahertz-bandwidth photodetectors for the visible and near-IR spectral range that provide highest performance-to-price ratio available today!
10/26/20151 Observational Astrophysics I Astronomical detectors Kitchin pp
“End station A setup” data analysis Josef Uher. Outline Introduction to setup and analysis Quartz bar start counter MA and MCP PMT in the prototype.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
Two-stage amplifier status test buffer – to be replaced with IRSX i signal recent / final (hopefully) design uses load resistor and voltage gain stage.
Timing Performance of Micro-Channel Plates and other detectors with different Front-end Architectures Jean-François Genat CNRS/IN2P3 LPNHE Paris PH-ESE.
Optimization of Detectors for Time of Flight PET Marek Moszyński, Tomasz Szczęśniak, Soltan Institute for Nuclear Studies, Otwock-Świerk, Poland.
Timing properties of MCP-PMT K.Inami (Nagoya university, Japan) - Time resolution - Lifetime - Rate dependence Photon Detector Workshop at Kobe,
July 4, 2008 SuperBelle Meeting, KEKPeter Križan, Ljubljana Peter Križan University of Ljubljana and J. Stefan Institute Burle MCP PMTs as photon detector.
PMT Readout and Floor Triggering Charge estimation using the times over the thresholds Event Building and Triggering + multiplicity George Bourlis.
Status of the ETL 9125FLB Photomultiplier Tubes Steve Bache UNC-Wilmington.
Timing Studies of Hamamatsu MPPCs and MEPhI SiPM Samples Bob Wagner, Gary Drake, Patrick DeLurgio Argonne National Laboratory Qingguo Xie Department of.
28 June 2007G. Pauletta: ALCPG Tests of IRST SiPMs G. Pauletta Univ. & I.N.F.N. Udine Outline 1.IRST SiPMs : baseline characteristics 2.first application.
Update on Physical Parameters that influence Timing Jean-Francois Genat LPNHE Paris LAPPD Electronics & Integration Review July 9th 2012, Chicago.
Jean-François Genat Fast Timing Workshop June 8-10th 2015 FZU Prague Timing Methods with Fast Integrated Technologies 1.
Basic Measurement of the Hamamatsu 10 inch PMT at –40 degree –40 degree Hiroko Miyamoto Dept. of Physics CHIBA University The Uniformity measurement of.
Considerations about Large area - Low cost Fast Imaging Photo-detectors Jean-Francois GENAT University of Chicago, LPNHE Paris Workshop on Timing Detectors,
PPAC Jonathan Olson University of Iowa Thesis Defense 8 April 2005.
1 Development of a Large Area Photodetector with a Fast Phosphor Anode Toru Iijima Kobayashi-Maskawa Institute Nagoya University Open Meeting for the Hyper-Kamiokande.
The photomultiplier tubes selection for KM2A electromagnetic particle detectors (EDs) hou chao IHEP The 2nd workshop of air shower detection at high altitudes.
Time Pick-off Techniques Jean-Francois Genat CNRS/IN2P3/LPNHE Paris IEEE Nuclear Science Symposium and Medical Imaging Conference October 23d 2011, Valencia,
Proposal for the after-pulse effect suppression  Observation of pulses and after-pulses  Shape measurement  Algorithm  Results  Efficiencies for after-pulse.
Preamplifier R&D at University of Montreal for the drift chamber J.P. Martin, Paul Taras.
Simulation of the Time Response of a VPT
Overview of SuperB Particle identification, and work towards the TDR
TDR Measurement of MCP Anode
Update of time measurement results with the USB WaveCatcher board & Electronics for the DIRC-like TOF prototype at SLAC D.Breton , L.Burmistov,
Summary of experience with Tevatron synchrotron light diagnostics
El-Mul Technologies Ltd – Confidential & Proprietary
APD, Introduction Victor Rykalin
Instrumentation for Colliding Beam Physics 2017
Progress on the development of a low-cost fast-timing microchannel plate photodetector Junqi Xie1, Karen Byrum1, Marcel Demarteau1, Joseph Gregar1, Edward.
Department of Physics and Astronomy,
Measured baseline fluctuations and dark counts with Burle-Photonis MCP-PMT's Jean-Francois Genat and Edward May Dec 2009 –Jan 2010.
Jean-Francois Genat, Herve Grabas, Eric Oberla August 2d 2010
MCP Electronics Time resolution, costs
Latest Results from T979: PSec Time-of-flight
A fast LED driver prototype for HCAL calibration
Development of hybrid photomultiplier for Hyper-Kamiokande
Performance test of ACEM-detector (Aluminum Cathode Electron Multiplier) Marcus Palm AB-ATB-EA M. Palm, CERN.
md-NUV PET project meeting
T2Kロシアグループに向けたMPPC(SiPM)の性能評価
Position measurements with Picosecond timing
Presentation transcript:

Efficiency, Dark noise, and Baseline fluctuations with Burle-Photonis MCP-PMT's Jean-Francois Genat and Edward May Dec 2009 –Jan 2010

MCP Signal development Fast rise-time: thin 2d gap, low LC parasitics Jean-Francois Genat, Large Area Picosecond Photo-Detectors Electronics, Clermont-Ferrand, January 28 th 2010 MCP signal rising edge: qE = ma l = 1mm, E=100V/mm, tr=250ps Slown down by: RC= 50 . 5pF = 250ps

MCP Signal development Fast rise-time: thin 2d gap, low RLC elements Jean-Francois Genat, Large Area Picosecond Photo-Detectors Electronics, Clermont-Ferrand, January 28 th 2010 MCP signal rising edge: qE = ma Example: l = 1mm, E=200V/mm, tr=250ps Effect of passive elements: C=capacitance of the detector R=50  C R Inductance to the ground return V(t)

MCP Signal development Rise time is RC dependent at the first order Jean-Francois Genat, Large Area Picosecond Photo-Detectors Electronics, Clermont-Ferrand, January 28 th 2010 First order model: I 0 (t) C R I 1 (t)

10 and 25  m 2” x 2” Burle-Photonis MCP tested - 25  m MCP HV: kV Signals taken on one anode pad, all other pads grounded: - 10  m MCP HV: kV Signals taken on one anode pad, all other pads grounded: Use Ed May’s calibrated laser test setup at Argonne - 408nm light set at 100 Photo-Electrons - TDS 6154C 18GHz bandwidth from Tektronix Experimental conditions Jean-Francois Genat, Large Area Picosecond Photo-Detectors Electronics, Clermont-Ferrand, January 28 th 2010

408nm 70ps laser 100 Photo-Electrons Cable bandwidth: 3.5 GHz Conclusions: - Gain is 40mV/100 = 0.4mV/PE (25  m) at 2100 V 5mV/100 = 50  V/PE (10  m) at 2500V - 10  m somewhat faster rise time, longer trailing edge, presumably due to 4 pads connected together. - The rise time does NOT depend upon the amplitude Measured Signals Jean-Francois Genat, Large Area Picosecond Photo-Detectors Electronics, Clermont-Ferrand, January 28 th 2010

Impulse dark noise vs HV Conclusion: At full efficiency (25  m 2000V, 10  m 2500V), dark counts rates are: 25Hz (25  m) 80Hz (10  m) Jean-Francois Genat, Large Area Picosecond Photo-Detectors Electronics, Clermont-Ferrand, January 28 th 2010

MCPs Efficiency and Baseline noise Efficiency plateau and baseline noise (left: 25  m, right 10  m) Plateaux are 300V wide for both MCPs Baseline rms below 1 mV rms (system noise), no dependence with the High Voltage 10  m MCP showed double and triple after-pulses (not included in the count rates) Jean-Francois Genat, Large Area Picosecond Photo-Detectors Electronics, Clermont-Ferrand, January 28 th 2010 ORTEC 9327 CFD

Conclusions MCP PMTs show efficiency plateaux, baseline fluctuations and dark counts better than the best Photo-multiplier tubes With: - Faster signals (device is thinner, consequently, a better timing resolution) rise-time ps (1ns PMTs) - Less noise compared to “good” PM Tubes: dark counts ( Hz PMTs) Jean-Francois Genat, Large Area Picosecond Photo-Detectors Electronics, Clermont-Ferrand, January 28 th 2010