DECam Spectrophotometric Calibration DECam calibration workshop, TAMU April 20 th, 2009 Jean-Philippe Rheault, Texas A&M University.

Slides:



Advertisements
Similar presentations
PPLN Frequency- Doubling Project Diana Parno Hall A Parity Collaboration Meeting May 17, 2007.
Advertisements

Good Practices of Fluorescence Spectroscopy
Optical sources Lecture 5.
CAVITY RING DOWN SPECTROSCOPY
11 Components of Optical Instruments Lecture Spectroscopic methods are based on either: 1. Absorption 2. Emission 3. Scattering.
Sub-Doppler Resolution Spectroscopy of the fundamental band of HCl with an Optical Frequency Comb ○ K. Iwakuni, M. Abe, and H. Sasada Department of Physics,
Present status of the laser system for KAGRA Univ. of Tokyo Mio Lab. Photon Science Center SUZUKI, Ken-ichiro.
An Optical Receiver for Interplanetary Communications Jeremy Bailey.
Precision Spectroscopy: some considerations S. Deustua STSCI 2014 STSCI Calibration Workshop 1.
Results The optical frequencies of the D 1 and D 2 components were measured using a single FLFC component. Typical spectra are shown in the Figure below.
Renata Bartula, Chris Hagen, Joachim Walewski, and Scott Sanders
P.M. Paul, L.Vigroux, G. Riboulet, F.Falcoz. 2 Main Limitation in High gain Amplifier: Gain Narrowing Ti:Sa Pockels cell FWHM
K-Space Associates, Inc. kSA BandiT: Band-edge Thermometry.
Dye lasers The gain medium in a dye lasers is a solution made with an organic dye molecule. The solution is intensely coloured owing to the very strong.
Fiber-Optic Communications
EM Radiation Sources 1. Fundamentals of EM Radiation 2. Light Sources 3. Lasers.
Fiber-Optic Communications James N. Downing. Chapter 5 Optical Sources and Transmitters.
Fiber-Optic Communications
Fiber-Optic Communications
Neodymium:YAG Laser Nd3+ in yttrium-aluminum-garnet (Y3Al5O12)
Fiber Optic Light Sources
Fiber Bragg Gratings.
FBG and Applications The Filter that Breaks Grading Broptics Communications Corp.
MB1 T.O.F. II Precise timing Electron ID Eliminate muons that decay Tracking devices T.O.F. 0 & I Pion /muon ID precise timing 201 MHz RF cavities Liquid.
4-1 Chap. 7 (Optical Instruments), Chap. 8 (Optical Atomic Spectroscopy) General design of optical instruments Sources of radiation Selection of wavelength.
30. Nov I.Will, G. Klemz, Max Born Institute: Optical sampling system Optical sampling system for detailed measurement of the longitudinal pulse.
What is spectroscopy? It is the study of how matter interacts with electromagnetic radiation (gamma rays down to radio waves) Matter can interact with.
5 Components Common to All Optical Spectrometers Source Transparent Sample Holder Wavelength Selector Radiation Detector Signal Processor and Readout.
October 16-18, 2012Working Group on Space-based Lidar Winds 1 AEOLUS STATUS Part 1: Design Overview.
Profile Measurement of HSX Plasma Using Thomson Scattering K. Zhai, F.S.B. Anderson, J. Canik, K. Likin, K. J. Willis, D.T. Anderson, HSX Plasma Laboratory,
A 5 fs high average power OPCPA laser system for attosecond pulse production Philip Bates, Yunxin Tang, Emma Springate and Ian Ross Central Laser Facility,
Double-Clad Erbium-Ytterbium Co-Doped Fiber Laser Colin Diehl & Connor Pogue.
ULTRA-BROAD BANDWIDTH CAVITY ENHANCED ABSORPTION SPECTROSCOPY Paul S. Johnston Kevin K. Lehmann Department of Chemistry University of Virginia.
Spectrophotometer Prof.Dr. Moustafa M. Mohamed Vice Dean Faculty of Allied Medical Science Pharos University in Alexandria, EGYPT.
1 SNAP Calibration Hardware Contributors: Chuck Bower Nick Mostek Stuart Mufson Mike Sholl.
DECam Daily Flatfield Calibration DECam calibration workshop, TAMU April 20 th, 2009 Jean-Philippe Rheault, Texas A&M University.
Nanonics CryoView 2000™ CryoView 2000™ Product Presentation.
Simple Multiwavelength Time-Division Multiplexed Light Source for Sensing Applications Thilo Kraetschmer and Scott Sanders Engine Research Center Department.
Astronomical Instrumentation at Texas A&M Jennifer Marshall Darren DePoy.
Electronic Transition of Ruthenium Monoxide Na Wang, Y. W. Ng and A. S.-C. Cheung Department of Chemistry The University of Hong Kong.
Laser-Based Finger Tracking System Suitable for MOEMS Integration Stéphane Perrin, Alvaro Cassinelli and Masatoshi Ishikawa Ishikawa Hashimoto Laboratory.
1.Stable radiation source 2.Wavelength selector 3.Transparent sample holder: cells/curvettes made of suitable material (Table 7- 2) 4.Radiation detector.
V. Sonnenschein, I. D. Moore, M. Reponen, S. Rothe, K.Wendt.
Spectrophotometer.
1 Calibration Screen Development Claire Cramer Brian Stalder Gautham Narayan Christopher Stubbs Department of Physics Harvard University Claire Cramer.
Development of a System for High Resolution Spectroscopy with an Optical Frequency Comb Dept. of Applied Physics, Fukuoka Univ., JST PRESTO, M. MISONO,
Optical sources Types of optical sources
RECENT DEVELOPMENT IN SUM FREQUENCY GENERATION SPECTROSCOPY SYSTEMS
Workshop for advanced THz and Compton X-ray generation
1 Progress of the Thomson Scattering Experiment on HSX K. Zhai, F.S.B. Anderson, D.T. Anderson HSX Plasma Laboratory, UW-Madison Bill Mason PSL, UW-Madison,
February 17-18, 2010 R&D ERL Brian Sheehy R&D ERL Laser and laser light transport Brian Sheehy February 17-18, 2010 Laser and Laser Light Transport.
Photodetection EDIT Absolute Measurement of the Quantum Efficiency of a Classical PMT Task: measure the QE of a PMT in the wavelength interval 200 to 800.
An H- stripping laser using commercial, diode-pumped Nd:YAG amplifiers Russell Wilcox Laser Stripping Workshop, April 11, 2011.
Topic report 11/09/01 Optical Spectrum Analyzer (OSA) Speaker: Chieh-Wei Huang Advisor: Sheng-Lung Huang Solid-State Laser Crystal and Device Laboratory.
The dye is a large molecule with a large number of closely spaced vibrational states – essentially a continuum of states. The pump pulse populates the.
Brenda Dingus Jan 2005 New Laser Calibration Status  New Laser vs Old Laser  Safety  Pond Data  Outrigger Data  How to Combine?
Optical calibration from ten to hundreds of meters for the Neutrino Burst Experiment (a poor man’s Km 3 underwater neutrino telescope) NESTOR/NOA Spyridon.
Digital Light Sources First introduced in 2001.
Optical Emitters and Receivers
Practical advices for using TCT (mostly for Particulars setups)
Mingyun Li & Kevin Lehmann Department of Chemistry and Physics
Using diode laser for atomic physics (I)
Relative Spectral Response and Flat Fields with Internal Calibration Lamps Luisa M. Lara IAA-CSIC Granada (SPAIN)
A.S. Ghalumyan, V.T. Nikoghosyan Yerevan Physics Institute, Armenia
Principle of Mode Locking
Detective Quantum Efficiency Preliminary Design Review
Instrumentation for UV and visible absorption
Fibre Lasers for SILIcon testing
LCLS Injector Laser System Paul R. Bolton, SLAC April 24, 2002
Injector Drive Laser Technical Status
Presentation transcript:

DECam Spectrophotometric Calibration DECam calibration workshop, TAMU April 20 th, 2009 Jean-Philippe Rheault, Texas A&M University

Spectrophotometric Response Calibration Requirements – Tunable across g, r, i, z and Y ( nm) Goal 330 nm (u) – Stable and rugged, need to work reliably with limited maintenance – Narrow bandwidth (2-3 nm or less) to be able to probe filter edges. – Spectral Power greater than 1 mW/nm to keep integrating times reasonable (Scan all 5 DES filters in less than 4 hours)

Schematic of the Spectrometric Calibration setup Description – Use tunable light source from 330nm to 1100nm to probe the system response at every wavelength – Scan with each filter to get the response function vs wavelength in each band – Uses same basic components as the daily flatfield Screen Photodiode monitoring – Tunable light source – Optical fiber to deliver light to top of telescope Screen Tunable light source Control & monitoring system Telescope Optical Fiber Beam shaping optics

Potential Tunable Light Sources Tunable lasers Monochromator Acousto-optic tunable filters – Crystal damage below 400nm – Limited power Supercontinuum generating fiber – Requires Ultra-short pulse laser ($$$) – No power below 400nm, still experimental

Light source: tunable laser Variety of tunable laser – Ti:Sapphire (700– 1100nm) – Dye laser wavelength range depends on actual dye – Laser diodes (mostly in NIR, max 100nm tuning range) Only solution: OPOs – The only way to span from 330nm to 1100nm – The OPO (optical parametric oscillator) absorbs one photon and converts it to two photons of lower energy – We can tune the output wavelength by changing the temperature or angle of the OPO crystal.

OPO Tunable laser Based on a Nd:YAG laser Many steps required to get u, g, r, I, z and Y, – 1064nm YAG fundamental – 355nm obtained through THG – 420nm – 1200nm obtained with OPO – nm obtained with SHG This increases the alignment problems Commercial systems claim to be easy to use

Tunable laser Pros – Very Narrow linewidth (~5cm -1 or nm) – Good power output over whole wavelength range > 10mW – Can be fiber coupled easily – Computer controlled wavelength selection (with some human intervention) Cons – Expensive ~100k$, – May require frequent re-alignment, – Water cooled. – Pump lamp replacement and general maintenance. Pump lifetime (30 milion pulses or Hz) – Beam Power Stability of a few %, intrinsic to non-linear processes Can be compensated by closed loop monitoring

Light source: Monochromator Monochromator based source – Broadband light source Xe or Halogen Requires compact and bright arc or filament for efficient coupling in mono slit. – Acceptance angle of the monochromator limits how much we can focus the beam. Limited by filament or arc brightness – Monochromator Can have 3 gratings to cover whole range efficiently Compromise: output power depends on (slit width) 2, narrow band= less power – Slit output is coupled to a fiber Fiber bundle

Monochromator Pros – More rugged and simpler than laser. – Computer controlled tuning (Motorized slit, grating turret, lamp changer) – Cheaper than laser ~ 25 k$ Cons – Lower power/nm, especially at UV wavelength – Large bandwidth (2-3 nm) required to get enough signal (power ~ bandwidth 2 ) – Fiber coupling more complicated (slit to fiber)

Optical Fibers Fibers are the only option, light source 30m from end of telescope Fiber ends fixed top of telescope Beam shaping Optics will insure the fiber output is uniform on the screen Use of bifurcated fibers – to separate beam and get multiple illumination points – in-line monitoring Special UV fiber (Low OH-) is required below 500nm

UV and Vis-IR fibers

Monitoring and calibration Similar to the system described in daily flat – Photodiodes In line Facing the screen In the focal plane – In line photodiode used for retroactive loop Eliminates fluctuations and long term drift Essential because source output depends on several factors – Laser pump lamp degradation – Laser Alignment – Monochromator slit size – Fiber coupler efficiency – Etc… – Calibration of photodiodes based on NIST standards Will transfer the calibration using our own calibration system

Available Absolute NIST calibrated references UV: UV enhanced Si Vis: Si Photodiode NIR: InGaAs photodiode Source: NIST Special Publication (2008)

Proof of concept Currently working on a monochromator based spectrometric calibration setup for LCO Use it to calibrate the Swopes and Dupont Good proof of concept for transfer to a bigger telescope

Summary Will use same screen and monitoring photodiodes as for Daily flat Price and durability are drawbacks of tunable laser Available power is the problem with the Monochomator Fibers have reasonable losses should be good We will test a mono system for LCO later this year.