WHISPER Measurement of DC Magnetic field amplitude Cross Calibration Workshop 2-3 February 2006 AUTHORS: SURAUD Xavier, DECREAU Pierrette, MAZOUZ Farida,

Slides:



Advertisements
Similar presentations
DAM-Île de France Département Analyse, Surveillance, Environnement 06/06/2014 DIF/DASE/B.ALCOVERRO 1 INFRASOUND SENSOR CALIBRATION DEVICE 13/11/2001 Infrasound.
Advertisements

Gravitational Wave Astronomy Dr. Giles Hammond Institute for Gravitational Research SUPA, University of Glasgow Universität Jena, August 2010.
Technician License Course Chapter 2 Lesson Plan Module 2 – Radio Waves & Signals.
Sampling theory Fourier theory made easy
Physics 145 Introduction to Experimental Physics I Instructor: Karine Chesnel Office: N319 ESC Tel: Office hours: on appointment.
Which describes a variation of wave frequency ω(t) in a geometric-optic approximation [4]. Here n(ω) is the refractive index of the medium, is the vector.
Higher order statistics in magnetoacoustic NDT Nicolae Cretu*, Gelu M Nita**, Attila Boer*, Mihail Pop* *Physics Department, Transilvania University, Eroilor.
Statistical Analysis of Electrostatic Turbulences over Seismic Regions T. Onishi and J.J. Berthelier Centre d'Etude des Environnements Terrestre et Planétaires.
Spectrum Analyzer. Another Oscilloscope??? Like an oscilloscope Oscilloscope in time domain Spectrum analyzer in frequency domain (selectable)
1 Speech Parametrisation Compact encoding of information in speech Accentuates important info –Attempts to eliminate irrelevant information Accentuates.
Ultrasound Medical Imaging Imaging Science Fundamentals.
A presentation on Bandwidth 8/17/1996 D.Geneus. Topics The Electromagnetic Spectrum Signals Signal Bandwidth Channel Bandwidth References.
GLAST LAT ProjectI&T Meeting – Feb 12, 2003 W. Focke 1 EM timing analysis Warren Focke February 12, 2004.
Physical-layer Identification of RFID Devices Authors: Boris Danev, Thomas S. Heyde-Benjamin, and Srdjan Capkun Presented by Zhitao Yang 1.
 Distortion – the alteration of the original shape of a waveform.  Function of distortion analyzer: measuring the extent of distortion (the o/p differs.
Octiv RF Power monitoring technology “. Talk Outline Impedans VI technology Introduction to power monitoring Need for VI Probes Why IV sensors are needed.
Spectrum Analyzer Basics Copyright 2000 Agenda Overview: What is spectrum analysis? What measurements do we make? Theory of Operation: Spectrum analyzer.
Ni.com Data Analysis: Time and Frequency Domain. ni.com Typical Data Acquisition System.
Workshop on Earthquakes: Ground- based and Space Observations 1 1 Space Research Institute, Austrian Academy of Science, Graz, Austria 2 Institute of Physics,
Ionospheric-magnetospheric VLF Wave Propagation: RPI/IMAGE-HAARP Correlative Study RPI/IMAGE-HAARP Correlative Study V. Paznukhov, B. Reinisch, G. Sales,
Solar observation modes: Commissioning and operational C. Vocks and G. Mann 1. Spectrometer and imaging modes 2. Commissioning proposals 3. Operational.
Acoustic Analysis of Speech Robert A. Prosek, Ph.D. CSD 301 Robert A. Prosek, Ph.D. CSD 301.
Electronic Communications: A Systems Approach Beasley | Hymer | Miller Copyright © 2014 by Pearson Education, Inc. All Rights Reserved Information and.
Effect of data gaps: Comparison of different spectral analysis methods Effect of data gaps: Comparison of different spectral analysis methods Catalin Negrea.
93 SOURCE TIME SERIES VOCAL TRACT TRANSFER FUNCTION VOICE TIME SERIES VOICE SPECTRUM SOURCE TIME SERIES VOCAL TRACT TRANSFER FUNCTION VOICE TIME SERIES.
Ultrasound Imaging Basic Principle: sound wave pulse emitted at >20 kHZ, some reflected, and some transmitted. Reflection from single signal – A-scan Reproduced.
Characterization of core and edge turbulence in L- and H-mode Alcator C-Mod plasmas Outline: Alcator C-Mod tokamak Fluctuation diagnostics Low to high.
Systems (filters) Non-periodic signal has continuous spectrum Sampling in one domain implies periodicity in another domain time frequency Periodic sampled.
Adaphed from Rappaport’s Chapter 5
LPC-analysis-VOSIM-resynthesis Combined class December 18 th 2012 Johan & Peter Institute of Sonology Royal Conservatory, The Hague.
Technician License Course Chapter 2 Radio and Electronics Fundamentals
Исследование широкополосной ELF турбулентности по данным спутника FAST И.В. Головчанская, Б.В. Козелов, И.В. Дэспирак Полярный геофизический институт.
C. Palomba - DA Meeting Update on the analysis of VSR1 data, focusing attention on the presence of spectral disturbances. More data  more.
Observation of a Non Thermal Continuum radio event during the CLUSTER Tilt campaign 17th CLUSTER Workshop Uppsala, Sweden, 12 – 15 May 2009 Uppsala May.
Effective drift velocity and initiation times of interplanetary type-III radio bursts Dennis K. Haggerty and Edmond C. Roelof The Johns Hopkins University.
Z bigniew Leonowicz, Wroclaw University of Technology Z bigniew Leonowicz, Wroclaw University of Technology, Poland XXIX  IC-SPETO.
A. Vaivads, M. André, S. Buchert, N. Cornilleau-Wehrlin, A. Eriksson, A. Fazakerley, Y. Khotyaintsev, B. Lavraud, C. Mouikis, T. Phan, B. N. Rogers, J.-E.
CAA 9th Cross-Calibration Workshop, Cambridge, England, 25th-27th March CLUSTER / STAFF ● status of calibration and archiving activities ● archiving.
Feedback Filters n A feedback filter processes past output samples, as well as current input samples: n Feedback filters create peaks (poles or resonances)
This material is based upon work supported in part by National Science Foundation Award PHY May 30-31, 2003, LIGO G Z APS NW Section Meeting.
Arrival time variations of pulses in shallow water and low frequency acoustical underwater positioning B.Katsnelson (Voronezh Uni, Russia) M.Badiey (Uni.
Analysis of Traction System Time-Varying Signals using ESPRIT Subspace Spectrum Estimation Method Z. Leonowicz, T. Lobos
An electron/positron energy monitor based on synchrotron radiation. I.Meshkov, T. Mamedov, E. Syresin, An electron/positron energy monitor based on synchrotron.
Search for bursts with the Frequency Domain Adaptive Filter (FDAF ) Sabrina D’Antonio Roma II Tor Vergata Sergio Frasca, Pia Astone Roma 1 Outlines: FDAF.
Signal acquisition A/D conversion Sampling rate  Nyquist-Shannon sampling theorem: If bandlimited signal x(f) holds in [-B;B], then if f s = 1 / T.
SOUNDS RECORDING AND REPRODUCTION The Volume of the Wave n The Amplitude is a measure of volume n The wave pink is softer than the blue wave. n It represents.
Fourier Analyses Time series Sampling interval Total period Question: How perturbations with different frequencies contribute to the turbulent kinetic.
LIGO- G Z 11/13/2003LIGO Scientific Collaboration 1 BlockNormal Performance Studies John McNabb & Keith Thorne, for the Penn State University.
1 Magnetic Field Modulus Estimation Using Whisper. Comparison with FGM LPCE/CNRS February 2007 Alban Rochel, Edita Georgescu, Jonny Gloag, Pierrette.
ANALOG SPECTRUM ANALYSIS. TOPICS Bank-of-filters spectrum analyzer Sequential spectrum analyzer –Variable tuning filter spectrum analyzer –Superheterodyne.
FUNCTION GENERATOR.
1 Electron Density Processing Chain: Presentation, Production Status LPCE/CNRS February 2007 Alban Rochel, Pierrette Décréau, Jean-Louis Rauch, Jean-Gabriel.
WHISPER Cross-caibration activities
Content: Distortion at electronic loads
LFR first PFM calibration results
WHISPER Report Jean Gabriel Trotignon and WHISPER Team
Solar Probe Plus FIELDS Instrument PSR - MEP Introduction
Mutual Impedance MEasurements, MIME as part of the EJSM JGO/RPWI
Targeted Searches using Q Pipeline
Stochastic background search using LIGO Livingston and ALLEGRO
Month 2002 doc.: IEEE /xxxr0 Nov 2003
FDS, Kurtosion and Reliability Testing
EE521 SystemView Example James K Beard, Ph.D. (215) 12/8/2018
Results from offline processing
Coherent Coincident Analysis of LIGO Burst Candidates
Fourier Analyses Time series Sampling interval Total period
Uses of filters To remove unwanted components in a signal
Lec.6:Discrete Fourier Transform and Signal Spectrum
Measurements of lifetimes of high-l solar p-modes in sunspots
Achintya Choudhury Bhartiya Skill Development University Jaipur India
Presentation transcript:

WHISPER Measurement of DC Magnetic field amplitude Cross Calibration Workshop 2-3 February 2006 AUTHORS: SURAUD Xavier, DECREAU Pierrette, MAZOUZ Farida, RAUCH Jean-Louis, Patrick CANU, ROCHEL Alban, TROTIGNON Jean-Gabriel, VALLIERE Xavier

OUTLINE 1)WHISPER Sounding Technique 2)Estimation of B field amplitude 3) Comparison withy FGM: Case events

WHISPER Sounding experiment Emission (time t, frequency f) Reception (time t + Δt, frequency f) PLASMA Emitted signal : sine wave train of central frequency Fc Frequency sweep: covered by 80 Fc values, 4 – 80 kHz range Time table tc (Fc): not a linear function (there and back goes) Time Table Frequency sweep f0 f1 t1t0t2 f2

 FFT range : [3, 80] KHz  FFT Resolution: 163Hz A slice in frequency, centred on emitted Fc, is selected after each sounding It represents the response of the plasma in this band. Reception and Wave Analysis The wave analyser: Time seriesFrequency spectrum Selected Frequency slice

WHISPER Sounding experiment An example of active spectrum SALSA 09/09/ :09:18 Central triggered frequency The concatenation of triggered frequency slices forms the active spectrum This spectrum is dated from the central time of the sweep (duration 1.5s) Exact times of each reception (one per freq slice) are known

Fce harmonics Electron gyro-frequency estimation Resonance frequencies are known within +/- 163 Hz The harmonic n, yields Fce within +/- (163/n) Hz If the medium is stable during the sweep, a better precision can be achieved (correlation with a comb function ) Fce ( Hz) = 28 B (nT)

Compared WHISPER and FGM Fce estimations FGM data at 4sHigh res FGM data

( 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 ) harmonic order case study: Fce harmonics well separated from Fqn

(fce) (1)pre-treatment: (a) morphology (b) dynamics in a spectrum: position of resonances known at 163 Hz resolution (2) Hough transform: uses time continuity over a few spectra search for max correlation including position and slope of each ‘harmonic’ segment

WHISPER estimation of magnetic field modulus, compared to FGM measurement case study: Position of each harmonic after pre-treatment Whisper resolution +/-0.5 nT

case study: Whisper resolution Whisper and FGM compared time variations Conclusion: Whisper and FGM estimations are comparable

Perspectives: Could Whisper provide a useful reference of magnetic field value? Estimation from Fce harmonic of order n : ~1 nT at best (Higher orders perturbed by Fqn) Usage of full spectral information (when FGM measure is stationary over sweep): ~ 0.3 nT Image processing: Hough transform: to be determined Usage of statistical information (over few hours): ~ 0.1 nT should be achievable Confidence interval?