Instrumental Analysis Ion selective electrodes

Slides:



Advertisements
Similar presentations
CHEM 213 Instrumental Analysis
Advertisements

Summary of Potentiometry:
Introduction to Analytical Chemistry
Tracking Reaction Progress via Electrochemical Methods.
ISE Ion Selective Electrodes Prepared By Michigan Department of Environmental Quality Operator Training and Certification Unit.
Electroanalytical – Introduction Ch 21, 7th e, WMDS)
POTENTIOMETRY 9th lecture
Electrodes and Potentiometry
Section 11 Potentiometry. Potentiometric Electrodes Potentiometric electrodes measure: Activity not concentration Concepts to review: Activity and affect.
Potentiometry. pH is a Unit of Measurement  pH = Power of Hydrogen (H + )  Defined as the Negative Logarithm of Hydrogen Ion Activity  pH = log (1/H.
Field Methods of Monitoring Aquatic Systems Unit 10 – Ion-Selective Electrodes Copyright © 2006 by DBS.
© Sauvé 2002 Sébastien Sauvé Department of Chemistry Université de Montréal Metal speciation using ion-selective electrodes.
Chem. 133 – 3/5 Lecture. Announcements Lab –Set 2 Period 2 Labs Set to Finish 3/10 –3/12 will be make up day (for both Period 1 and Period 2 labs) –Set.
Potentiometry and the Detection of Fluoride
Electrochemistry II. Electrochemistry Cell Potential: Output of a Voltaic Cell Free Energy and Electrical Work.
ANALYTIC METHODS II. PART Jana Švarcová.  Chromatography  Electrophoresis  Potentiometry  Titration  Spectrophotometry.
Stoichiometry: Quantitative Information about chemical reactions.
Potentiometric Methods
Result validation. Exercise 1 You’ve done an analysis to the best of your ability using the correct procedure. Is your answer correct? possibly, hopefully.
The Solubility Product Principle. 2 Silver chloride, AgCl,is rather insoluble in water. Careful experiments show that if solid AgCl is placed in pure.
COMMUNICATING CONCENTRATION: Section 5.3.  Most solutions are similar in that they are colorless and aqueous, so there is no way of knowing, by looking.
Unit 4 Solubility Dilutions MOLARITY Concentration
Ch. 16: Ionic Equilibria Buffer Solution An acid/base equilibrium system that is capable of maintaining a relatively constant pH even if a small amount.
UNIT III TUTORIAL 12: PRECIPITATION TITRATIONS. OBJECTIVES In this Tutorial you will be shown: 1. How titrations involving precipitation reactions can.
EDTA Titration EDTA = Ethylenediaminetetraacetic acid
Types of Chemical Reactions and Solution Stoichiometry – Part 2
Stoichiometry: Quantitative Information About Chemical Reactions Chapter 4.
Instrumental Analysis Fundamentals of Electrochemistry
Electroanalytical methods
Unit 2 Electrochemical methods of Analysis
Unit 4 Acids, Bases and pH. Water molecules dissociate and ionize to form H 2 0  H + + OH - Water  hydrogen ion + hydroxide ion In pure water, there.
CH 223 LECTURE # 15 SAMPLE QUESTIONS. The lesson is for not only accuracy, but speed. You will always be under some time constraint. You can work in pairs.
Solution Concentration
Solution Concentration solution: homogeneous mixture of substances present as atoms, ions, and/or molecules solute: component present in smaller amount.
Molarity, Dilution, and pH
Test 4 Review Advanced Chemistry. Equilibrium mA + nB  sP + rQ mA + nB  sP + rQ K eq = [P] s [Q] r K eq = [P] s [Q] r [A] m [B] n [A] m [B] n K sp =
Stoichiometry Calculations based on chemical reactions.
Announcements:. Last lecture 1.Organization of the nervous system 2.Introduction to the neuron Today – electrical potential 1.Generating membrane potential.
Chapter 15 Electrode Measurements “Chem 7” test in hospital lab. Na +, K +, Cl -, CO 2, glucose, urea, & creatinine ion-selective electrodes.
Chapter 21: Electrochemistry II
Electrochemical Methods Dr M.Afroz Bakht. Potentiometry Potentiometry is a method of analysis used in the determination of concentration of ions or substances.
Oxidation and Reduction Lecture 9. Law of Mass Action Important to remember our equation describes the equilibrium condition. At non-equilibrium conditions.
Chapter Goals (Membrane Potentials) After studying this chapter, students should be able to 1. explain what is meant by active transport and describe how.
To calculate the new pH, use the Henderson- Hasselbalch equation: 1141.
CHAPTER 15 REACTIONS AND EQUILIBRIA INVOLVING ACIDS, BASES, AND SALTS.
ERT207 Analytical Chemistry Complexometric Titration
Chapter 15 Applying equilibrium. The Common Ion Effect l When the salt with the anion of a weak acid is added to that acid, l It reverses the dissociation.
Electrodes and Potentiometry Introduction 1.)Potentiometry  Use of Electrodes to Measure Voltages that Provide Chemical Information - Various electrodes.
Previous Knowledge – 30S Chem – Solutions, Unit 1, and Equilibrium Content – p
Chem. 133 – 3/3 Lecture. Announcements Homework Set 2 (pass out) Grading –Working to get the Electronics labs and exam 1 graded by next Tuesday Lab –today.
POTENTIOMETRY.
Electrode Measurements – Ch 15
Art PowerPoints Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 14: ELECTRODES AND POTENTIOMETRY.
Stoichiometry: Quantitative Information About Chemical Reactions Chapter 4.
POTENTIALS AND THERMODYNAMICS OF CELLS (1) POTENTIALS AND THERMODYNAMICS OF CELLS (1)
Home Reading Skoog et al. Fundamentals of Analytical Chemistry. Chapter 10, 21.
Solution Concentration.  Lesson Objectives  Describe the concept of concentration as it applies to solutions, and explain how concentration can be increased.
SCI3023 ELECTROCHEMISTRY Chapter 8e: Potentiometry
Compleximetric Problems
Chem. 133 – 2/28 Lecture.
9.5 Dilution of Solutions In a dilution, a solvent, usually water, is added to a solution, which increases its volume and decreases the concentration.
Potentiometry Potential measurements of electrochemical cells
Stoichiometry: Quantitative Information About Chemical Reactions
Chapter 12 EDTA Titrations
Electrode Measurements – Ch 15
2.3 Neutralisation Titration:
Tracking Reaction Progress via Electrochemical Methods
Aqueous Solutions Pt. 2.
Chapter 23 Potentiometry.
Concentrations of Solutions
Presentation transcript:

Instrumental Analysis Ion selective electrodes Tutorial 6

Objectives By the end of this session, the student should be able to: Differentiate different types of ISE. Define selectivity of ISE. Calculate the E cell of ISE. Differentiate between direct, indirect , Std addition and potentiometric titration.

Applying Nernst equation to Ion-selective Electrodes where E is the potential of the galvanic cell containing the ion-selective electrode as an indicator electrode and a reference electrode. K is a constant specific for the ion selective electrode used. This equation applies to any ion-selective electrode. If the analyte is anion, the sign for n is negative.

Evaluate the constant in the preceding equation. Example 1 A cyanide ion-selective electrode obeys the equation: E = K – 0.05916 log [CN–] The potential was 0.230 V when the electrode is immersed in 1.00 mM NaCN. Evaluate the constant in the preceding equation. Using the result of (a), find [CN–] if E = 0.300 V. find [CN–] if E = 0.300 V. Solution: Evaluate the constant E = K – 0.05916 log [CN–] 0.230 = K – 0.05916 log (1.00 x 10-3) Constant, K = 0.407 V 0.300 = 0.407 – 0.05916 log [CN–] [CN–] = 1.55 x10-2 M

E ground water = k – (0.05916 / 1) log [F-] Example 2 When a F ion-selective electrode was immersed in a sample of ground water, the potential was 40.0 mV more positive than the potential of tap water that maintains its fluorinated water at the recommended level of 1.00 mg F/L. what is the concentration of F mg/L in the groundwater. Solution: E = 40.0 mV, aF-(tap) = 1.00 mg/L E ground water = k – (0.05916 / 1) log [F-] Etap water = k – 0.05916 log 1.0 Subtract: P.S. Note that we have 0.05916/n if the potential is in Volt and 59.16/n if the potential measured in millivolt We do not need to convert units . E ground water - Etap water = k- 0.05916 log [F-]- k +0.05916 log 1.0 0.04 = - 0.05916 log [F-] -0.676 = log [F-] Shift log (-0.676) = 0.21 Conc of F- in ground water= 0.21 mg/L

Selectivity Coefficient No electrode responds exclusively to one kind of ion. An electrode intends to measure ion A also may respond to ion X. The selectivity coefficient describes the relative response of the electrode to different species Where kA,X is the selectivity coefficient of A over X. The smaller the selectivity coefficient, the more selective the electrode to ion A, i.e., the less the interference by foreign ion X. A K+ ion-selective electrode has a selectivity coefficients: kK+, Na+ = 1 x 10-5 kK+, Cs+ = 0.44 kK+, Rb+ = 2.8 Na+ hardly interferes Cs+ interferes to The electrode responds with the measurement greater extent more to Rb+ than K+ For interfering ion with charge j, the response of the ion selective electrode can be described by the equation: a A: conc of analyte a X : conc of interfering ion n: charge of analyte j: charge of interfering ion

Example 3 One commercial sodium ion-selective electrode has a selectivity coefficient of kNa+, H+ = 36. When this electrode was immersed in 1.00 mM NaCl at pH = 8.00, a potential of 38 mV (versus SCE) was recorded. Neglecting activity coefficient, calculate the potential if the electrode were immersed in a 5.00 mM NaCl solution at pH 8.00. What would the potential be for 1.00 mM NaCl at pH 3.78? Solution: MNaCl = 0.001M, H+ = 10-8 M (pH =  log [H+]) a) E = constant + (0.05916n) log (aNa+ + kNa+,H+ . a H+) 0.038 = constant + (0.05916/1) log (0.001+ (36  10-8)) constant = 0.1393 V. E = 0.1393 + (0.05916/1) log (0.005 + (36  10-8)) = 3.3 mV = 0.003 V.

Example 4 A calcium ion-selective electrode obeys Nernst equation. The selectivity coefficients for several ions are listed. Interfering ion Y k Ca2+,Y Mg2+ 0.040 Ba2+ 0.021 Zn2+ 0.081 In a pure solution of 1.00x10-3 M Ca2+, the reading was +300.0 mV. a)What would be the voltage if the solution had the same calcium concentration plus Mg2+=1.00x10-3 M, Ba2+=1.00x10-3 M and Zn2+=5x10-4 M. b) If the interfering ions are present at equal concentrations, which ion interferes the most with the Ca2+ electrode?

For the pure  Ca2+ solution (without interference) we can write E = constant + (0.05916 / 2) log (1.00 10-3) Putting in E = 0.300 V gives constant = 0.389 V. For the solution containing the interfering ions, we can say that … E= 0.389 + (0.05916 / 2) log ((1.00x103) + (0.040)(1.00x10-3)+(0.021)(1.00x10-3) +(0.081)(5.00x10-4 )) = 0.3015 V At equal concentrations, Zn2+ interferes the most because it has the largest selectivity coefficient.

Applications of potentiometry 1- Direct potentiometry Example 5 In the potentiometric determination of Ca2+ in solution, the following calibration data was collected. A Ca2+ analyte solution yielded a measured potential of 300.8 mV. Find the concentration of Ca2+ in the unknown solution. [Ca2+], ppm log [Ca2+] Emeas, mV 15 1.176 -338.5 35 1.544 -329.8 89 1.949 -316.5 150 2.176 -312.2 230 2.362 -303.7 400 2.602 -296.4 500 2.699 -295.5 650 2.813 -292.5 Calibration curve equation: y = m x + a = 29.052 x  373.54 where m (29.052) is the slope of the Nernst equation (theoretically 59.16/2=29.58) and a (373.54) is the intercept that represents the constant value. Substituting in the above equation by the potential measured for the unknown Ca2+, we get: 300.8 = – 373.54+ 29.052 x x = 2.504 [Ca2+] = antilog (2.504) = 319 ppm

2- Standard addition Potentiometry Basis of Calculations (single point standard addition) The formula for the Standard Addition calculation is: Where, Cu = concentration in the unknown sample. Cs = concentration in the standard. Vs = volume of standard. Vu = volume of sample E1 = electrode potential (mV) in the pure sample solution. E2 = electrode potential after the addition of standard. S = the electrode slope (0.05916/n).

Example 6 The wastewater from an industrial processing plant was routinely analyzed for lead as required by EPA. When a Pb ion-selective electrode and a SCE reference were immersed in 50.0 mL of the sample, the cell potential was found to be –0.118 volts. 5.00 mL of a 0.006 M solution of Pb2+ standard solution was added to the above sample and the measurement repeated; the cell potential was changed to –0.109 volts. What is the approximate concentration of Pb in the wastewater in mg/L? Solution cu = 4.93 x 10-4 mol/L atomic mass of Pb = 207.2 g/mol conc. of Pb = 4.93 x 10-4 X 207.2 = 0.1023 g/L conc. of Pb = 0.1023 g/L X 1000 = 102.3 mg/L

Exercise 1 (Instrumental Analysis (Skoog) The following cell was found to have a potential of 0.124 V: SCE // Cu2+ (3.25x10-3 M) / membrane electrode for Cu2+ When the solution of known copper activity was replaced with unknown solution, the potential was found to be 0.105 V. What is the pCu of this unknown solution? (solution pCu =  log [Cu2+] =3.14) Exercise 2 (Instrumental Analysis (Skoog) The following cell was employed for the determination of pCrO4: SCE// CrO42- (x M) / Ag2CrO4(s) / Ag(s) Find pCrO4 if the cell potential is 0.402 V. (EAg/Ag2CrO4 = 0.361 V, ESCE = 0.241 V) (solution pCrO4 = 6.76) Exercise 3 (Instrumental Analysis (Skoog) A glass /calomel electrode system was found to develop a potential of 0.0412 V when used in a buffer of pH 6.00; with an unknown solution the potential was observed to be 0.2004 V. Calculate the pH and [H+] of the unknown. (solution pH = 8.69, [H+] = 2.05 x 10-9 M)

SCE // Mg2+ (a = 3.32 x 10-3 M / membrane electrode for Mg2+ Exercise 4 (Instrumental Analysis (Skoog) The following cell was found to have a potential of 0.2714 V: SCE // Mg2+ (a = 3.32 x 10-3 M / membrane electrode for Mg2+ When the solution of known magnesium activity was replaced with an unknown solution, the potential was found to be 0.1901 V. What was the pMg of this unknown solution? (solution pMg = 5.226) Exercise 5 (Instrumental Analysis (Skoog) A 0.40 g sample of toothpaste was boiled with a 50 mL solution containing a citrate buffer and NaCl to extract the fluoride ion. After cooling, the solution was diluted to exactly 100 mL. The potential of a F selective ion/calomel system in a 25.0 mL aliquot of the sample is found to be 0.1823 V. Addition of 5.0 mL of a solution containing 0.00107 mg F/mL caused the potential to change to 0.2446 V. Calculate the weight percent of F in the sample. (solution % F in toothpaste = 4.25x10-4 %) Try to solve Problems 15-1, 15-8, 15-28, 15-29, 15-30, 15-34, 15-40. Harris text book, p342-345