Forensic Toxicology Use Only Analysis of ETG, ETS using the Thermo Scientific Exactive Mass Spectrometer Kent Johnson Fortes lab, Portland Oregon.

Slides:



Advertisements
Similar presentations
Improvements in Mass Spectrometry for Life Science Research – Does Agilent Have the Answer? Ashley Sage PhD.
Advertisements

1 The world leader in serving science Proprietary & Confidential WiSIM DIA Method Set-up Orbitrap Fusion MS MS Instrument Control Software v.1.1 SP1.
C.Bi 1, Y.Yamaguchi 1, S.Bamba 1, H.Kumada 2, K.Nakai 3 and T.Morimoto 1 1 Research and Development Office, Japan Chemical Analysis Center 2 Proton Medical.
Caffeine as a Surrogate for Cocaine in an HPLC Forensic Experiment Ray A. Gross Jr, Indravadan Shah and Muhamed Jasarevic Department of Physical Sciences.
* CORRESPONDING AUTHOR Bioanalysis of Exenatide: Intact Versus Signature Peptide Approach to Reach Optimal Sensitivity in Large Molecule Quantification.
© 2009 Perkin Elmer As Speciation in Apple Juice Charles Schneider, Presenter Kenneth Neubauer, Co-Author PerkinElmer.
11 Determination of the Levels of Fungicides on Citrus Fruits By Miseung Borgers Chem 4101, Fall 2008.
LC/MS WORKSHOP IOWA STATE UNIVERSITY Kamel Harrata  Instrument Description  Data Acquisition  Data Processing.
Investigation of Oxidative and Conjugative Metabolism Reactions with Liquid Chromatography / Accurate Mass High Resolution Mass Spectrometry Maciej Bromirski.
FIGURE 5. Plot of peptide charge state ratios. Quality Control Concept Figure 6 shows a concept for the implementation of quality control as system suitability.
Chemalys September 2009 Chemalys Jan Nordin Chemalys Massworks Extend the Limits of Your LC/MS-System Brukermøte i Massespektrometri 27 mai 2010.
Types of Chromatography Liquid chromatography versus gas chromatography? Applications? Volatile  GC Non-volatile  LC.
Comparison of chicken light and dark meat using LC MALDI-TOF mass spectrometry as a model system for biomarker discovery WP 651 Jie Du; Stephen J. Hattan.
Zlata D. Clarka, M. Laura Parnasb and Elizabeth L. Frankb
Simultaneous quantification of bergenin, catechin, and gallic acid from Bergenia ciliata and Bergenia ligulata by using thin-layer chromatography 张 慧.
Q-Exactive LC-MS. TurboFlow technology - Special columns - Complex valving - Extra pump UHPLC -Fast separation -Best separation.
Orbitrap Technology: New Frontiers in Pesticide Residue Analysis
* CORRESPONDING AUTHOR Use of High Resolution Mass Spectrometry (HRMS) to Solve Severe Issues Due to Isotopic Distribution in Regulated Bioanalysis Richard.
Peak-purity by LC-MS and LC-DAD Knut Dyrstad Erlend Hvattum Sharon Jara Arnvid Lie.
Sample Preparation Strategies for Routine Trace Mixture Analysis by NMR David Detlefsen, Kenneth Ray & Jeffrey Whitney.
Quantitative Insulin Analysis Using Liquid Chromatography–Tandem Mass Spectrometry in a High- Throughput Clinical Laboratory Z. Chen, M.P. Caulfield, M.J.
Integrated Targeted Quantitative Method for Insulin and its Therapeutic Analogs Eric Niederkofler 1, Dobrin Nedelkov 1, Urban Kiernan 1, David Phillips.
Analysis of Ibuprofen in Tablets According to the US Pharmacopoiea using a Varian 920-LC Analytical HPLC and Pursuit ® XRs column By Phuong Truong Varian.
DEVELOPMENT OF A RP-HPLC METHOD FOR THE DETERMINATION OF METFORMIN IN HUMAN PLASMA.
In Figure 3, and using the same reasoning for THC, the LOQs for cocaine (coc), MDMA, methamphetamine (meth), and amphetamine (amp) are estimated to be.
Chem. 231 – 2/18 Lecture. Announcements Set 2 Homework – Due Wednesday Quiz 2 – Next Monday Set 1 Labs –should be switching instruments today (or after.
MS Intro. MS requires gas-phase ions, why? MS uses magnetic and electric fields to control the path of a compound based on mass to charge ratio (m/z)
Finding a Needle in a Haystack: Using High Resolution Mass Spectrometry in Targeted and Non Targeted Searching for Food Contaminants Erik Verschuuren.
* CORRESPONDING AUTHOR Glucagon Bioanalysis by LC-MS: “Unprecedented Level of Sensitivity (10pg/mL) for a Novel Formulation” Jean-Nicholas Mess 1, Louis-Philippe.
By: Arafath and Nick. What is it  Chromatography is a technique that is used to separate the substances present in a mixture.  It is widely used to.
液相層析質譜分析 LC-MS Method development and Analyte Identification 授課教師:賴滄海教授 授課教師:賴滄海教授
Stability Indicating Assays for Dose Formulation Stability Testing Teresa Fuller GSK.
Chapter 1: Introduction Analytical Chemistry Analytical Chemistry Qualitative analysis Qualitative analysis Quantitative analysis Quantitative analysis.
Presentation overview
THC in Oral Fluid by LC-MS/MS Kristine Van Natta 24 Sep 2010.
Determination of metformin in urine (by Liquid Chromatography LC)
Toxicological Screening of 80 Drugs in Urine Using the High Resolution Exactive LC/MS Orbitrap Mass Spectrometer Coupled to Online Extraction and Turbulent.
The world leader in serving science For Research Use Only. Not for use in diagnostic procedures Quantitative Analysis of 4 Immunosuppressant Drugs in Whole.
What Bottlenecks are Slowing Down Your Lab? Software Solutions for Environmental Testing Charles Yang Strategic Marketing Manager Environmental Testing.
Introduction to Liquid Phase Mass Spectrometry
3M Drug Delivery Systems 3 Introduction A family of hydrofluoroalkane-compatible excipients based on oligomeric lactic acid (OLA) has been proposed for.
Data independent acquisition methods for metabolomics Stephen Tate, Ron Bonner AB SCIEX, 71 Four Valley Drive, Concord, ON, L4K 4V8 Canada A high resolution.
GUY’S & St THOMAS’ FOUNDATION TRUST A simple and rapid method for quantifying total and free Mycophenolic acid and its glucuronide metabolite using Electrospray.
Evolution GC-MS/MS: Pesticide analysis in canola oil Evolution GC-MS/MS: Pesticide analysis in canola oil Vivian Watts 1, Ingo Christ 1, Mark Misunis 2.
Target Analyses in Parallel Reaction Monitoring Mode (PRM)
Plasma Free Metanephrines Analysis using LC-MS/MS with Porous Graphitic Carbon Column Xiang He (Kevin) and Marta Kozak Thermo Fisher Scientific.
Metabolomics Part 2 Mass Spectrometry
For Clinical Research and Forensic Toxicology Use Only
Table 1. Quality Parameters Being Considered for Evaluation
Multi-Analyte LC-MS/MS Methods – Best Practice.
James Byrd, Marta Kozak 28 Apr 2011
Results and Discussion
Quantitation of 9 different coccidiostats in poultry using LC-MS/MS on a LCMS 8060 triple quadrupole Jana Rykl1; Ty Kahler2 1Shimadzu Switzerland GmbH,
Introduction Results Aim of the study Methods Conclusion References
Internal Standard method (experiment lab-4)
For Forensic Toxicology use Only
RESULTS and DISCUSSION
Agenda Welcome from the Skyline team!
LC-MS/MS Analysis of Tetracycline antibiotics in Honey using Advance UHPLC-EVOQ™ SIMA LAB PVT LTD.
A sensitive and repeatable method for characterization of sulfonamides and trimethoprim in honey using QuEChERS extracts with Liquid-Chromatography-Tandem.
Agility WCX SPE Cartridges
For Research Use Only. Not for use in diagnostic procedures
Clinical Research Use Only Not For Diagnostic Purposes
DETERMINATION OF ESTROGENIC STEROIDS IN SEWAGE SLUDGE SAMPLES FROM EIGHT DOMESTIC WASTEWATER TREATMENT PLANTS Jana Petre, Toma Galaon, Vasile Ion Iancu,
Peter Kovarik and Yves LeBlanc
High Resolution Quantitation of Microcystins with SCIEX X500R QTOF System KC Hyland.
Results and discussion Technical innovations
Simultaneous determination of creatinine, iohexol and p-aminohippuric acid in animal plasma by ultra-high-performance liquid chromatography–tandem mass.
Darrell Clinton and H. Dorota Inerowicz Purdue University
Damiana Gentili Qualified Person/QU Director 09/05/2019
Presentation transcript:

Forensic Toxicology Use Only Analysis of ETG, ETS using the Thermo Scientific Exactive Mass Spectrometer Kent Johnson Fortes lab, Portland Oregon

Forensic Toxicology Use Only Goal Development of an easy to use, interference free, less than 4 min analysis method for ETG and ETS in urine LOQ, 100ng/mL or better Method validation using QC’s and real samples

Exactive Benchtop LC-MS Resolution 100,000 at 1 scan per second 10,000 at 10 scans per second Mass accuracy Sub ppm Sensitivity 500 fg Buspirone with S/N >10:1 Dynamic range >10,000 within a spectrum Scan speed Up to 10 scans per second Mass range m/z Polarity switching One positive and one negative scan < 1 second (25K Resolution)

Ethinyl-Estradiol at Different Mass Resolutions Resolution: 10k, 30k, 50k, 100k m/z Relative Abundance Ethinyl-Estradiol, Butyl-Phthalate, (ubiquitous background ion)

Forensic Toxicology Use Only ETG and ETS in Urine

Forensic Toxicology Use Only Standards, QC and sample preparation ETG and ETS + 25uL int. std (IS) 100 uL urine + 900uL of mobile phase A Sample preparation method Inject 20uL Vortex Note: IS are ETG-D5 and ETS-D x dilution with mobile phase recommended

Forensic Toxicology Use Only LC/MS Method LC method – Thermo Hypersil Gold 50 x 2.5 mm, 5u – Mobile Phase A: 5mM Dihexylammonium acetate in LC DI H2O – Mobile Phase B: 5mM Dihexylammonium acetate in CAN – Mobile Phase C: ACN/IPA/Acetone = 45/45/10 v/v/v – Column Temp: 50 Deg C Exactive MS method – HESI source – Full scan MS 100,000 Resolution – External mass calibration – Extract chromatogram for drugs of interest better than 5ppm mass accuracy – Confirm the identity using mass accuracy and RT – Quantitate using peak area in the chromatogram

Forensic Toxicology Use Only ETG-ETS LC gradient Time (min)%A%B%CFlow (mL/min)

100 ng/mL EtG standard in urine TIC Spectrum amu Peak ½ ht amu XIC: ETG XIC: ETG-D5 ETG IS ETG Very High Specificity

100 ng/mL EtS standard in urine TIC Spectrum m/z Peak ½ ht amu XIC: ETS XIC: ETS-D5 ETS IS ETS Very High Specificity

Forensic Toxicology Use Only Ion Suppression Test - Water vs Urine 250 ng/mL std Urine Water No Ion Suppression Peak Areas Similar Analyte/IS ratio similar Urine Water EtG-D5 EtS-D5 EtG-D5 EtS-D5 EtG EtS EtG EtS Analyte IS

Forensic Toxicology Use Only Calibration curves and LOQ ETS ,000 ng/mL ETG ,000 ng/mL 25 ng/mL standards ETGETS ETG-D5ETS-D5 50 ng/mL standards ETGETS ETG-D5ETS-D5

Forensic Toxicology Use Only 100 ng/mL, 20 uL standards in urine ETG ETS ETG-D5 ETS-D5

Forensic Toxicology Use Only Urine – Negative control ETG ETS ETG < LOD ETS present ETG-D5 ETS-D5

Forensic Toxicology Use Only QC 375 ng/mL - ETG ETG ETS present ETG-D5ETS-D5 ETG=317 ng/mL, ETS present

Forensic Toxicology Use Only QC 1250 ng/mL - ETG ETG ETS not expected found 190 ng/mL ETG-D5 ETS-D5 ETG=1164 ng/mL, ETS=190 ng/mL

Forensic Toxicology Use Only Urine sample ETG < LOD ETS< LOD ETG-D5 ETS-D5 ETG and ETS < LOD

Forensic Toxicology Use Only Urine sample ETG ETS ETG-D5 ETS-D5 ETG=312247, ETS= ng/mL

Forensic Toxicology Use Only Urine sample ETG=68116, ETS=17789 ng/mL ETG ETS ETG-D5 ETS-D5

Forensic Toxicology Use Only ETG ETS Urine sample ETG=14397, ETS=1176 ng/mL ETG-D5 ETS-D5

Forensic Toxicology Use Only ETGETS Urine sample Passes lie detector test for alcohol but drinks 1 bottle of Nyquil every night ETG=459.9 ETS=160.8 ng/mL ETG-D5 ETS-D5

Forensic Toxicology Use Only ETG ETS Urine sample ETG=864.9 ETS=688.3 ng/mL ETG-D5ETS-D5

Forensic Toxicology Use Only ETGETS Urine sample ETG=559.2 ETS=616.4 ng/mL ETG-D5ETS-D5

Forensic Toxicology Use Only ETG ETS Urine sample ETG<LOQ, ETS< LOQ (~51.7 ng/mL) ETG-D5ETS-D5

Forensic Toxicology Use Only Conclusions Assay based on Exactive ultra high resolution MS coupled to LC system is – Well suited for accurate analysis of ETG and ETS – Analysis time of 4 min for ETG and ETS – ETG LOQ = 100ng/mL, LOD = 25ng/mL – ETS LOQ = 25ng/mL, LOD = 10ng/mL Exactive with a resolution of 100,000 offers >/= SRM selectivity (SRM data comparison not shown) Very easy for method development and routine operation Can be multiplexed for even higher throughput

Forensic Toxicology Use Only Acknowledgements Kent Johnson, Fortes Lab Portland, Oregon Marta Kozak, Thermo Fisher Scientific Perkin Elmer (Steroid kit) LipoMed (EtS/EtS D5) Cerilliant (EtG/EtG D5) Thermo Scientific; Instrument, Technical, and application support TCI - Dihexylammonium acetate