QA Tests Tests for each sensor Tests for each strip Tests for structures Process stability tests Irradiation tests Bonding & Module assembly Si detectors1272.

Slides:



Advertisements
Similar presentations
Silicon Technical Specifications Review General Properties Geometrical Specifications Technology Specifications –Mask –Test Structures –Mechanical –Electrical.
Advertisements

Detector module development for the CBM Silicon Tracking System Anton Lymanets for the CBM collaboration Universität Tübingen, Kiev Institute for Nuclear.
Trapping in silicon detectors G. Kramberger Jožef Stefan Institute, Ljubljana Slovenia G. Kramberger, Trapping in silicon detectors, Aug , 2006,
Belle-II Meeting Nov Nov Thomas Bergauer (HEPHY Vienna) Status of DSSD Sensors.
Workshop on Silicon Detector Systems, April at GSI Darmstadt 1 STAR silicon tracking detectors SVT and SSD.
128 September, 2005 Silicon Sensor for the CMS Tracker The Silicon Sensors for the Inner Tracker of CMS CMS Tracker and it‘s Silicon Strip Sensors Radiation.
DPG 2001 Frank Hartmann (IEKP) P-irradiated-oxygenated Non-irradiated-oxygenated Non-irradiated-non-oxygenated P-irradiated-non-oxygenated sensors put.
Module Production for The ATLAS Silicon Tracker (SCT) The SCT requirements: Hermetic lightweight tracker. 4 space-points detection up to pseudo rapidity.
Sensors for CDF RunIIb silicon upgrade LayerR min (cm)1 MeV eq-n cm * * * * * *10.
The LHCb Inner Tracker LHCb: is a single-arm forward spectrometer dedicated to B-physics acceptance: (250)mrad: The Outer Tracker: covers the large.
Embedded Pitch Adapters a high-yield interconnection solution for strip sensors M. Ullán, C. Fleta, X. Fernández-Tejero, V. Benítez CNM (Barcelona)
STS Simulations Anna Kotynia 15 th CBM Collaboration Meeting April , 2010, GSI 1.
Semiconductor detectors
SVX4 chip 4 SVX4 chips hybrid 4 chips hybridSilicon sensors Front side Back side Hybrid data with calibration charge injection for some channels IEEE Nuclear.
Why silicon detectors? Main characteristics of silicon detectors: Small band gap (E g = 1.12 V)  good resolution in the deposited energy  3.6 eV of deposited.
Characterization of double sided silicon micro-strip sensors with a pulsed infra- red laser system for the CBM experiment Pradeep Ghosh 1,2 & Jürgen Eschke.
Performance test of STS demonstrators Anton Lymanets 15 th CBM collaboration meeting, April 12 th, 2010.
V. Pugatch CBM Collaboration Meeting, Dubna, Oct CBM Silicon Tracking System. Results of the pre-prototype detector module test. V.M. Pugatch.
J.M. Heuser — CBM Silicon Tracker 1 Johann M. Heuser, GSI Darmstadt CBM Collaboration Meeting JINR Dubna, 15 October 2008 CBMCBM Review of the first in-beam.
ALBA Synchrotron – 17 June 2010 Centro Nacional de MicroelectrónicaInstituto de Microelectrónica de Barcelona First Measurements on 3D Strips Detectors.
Current status of the silicon strip sensor development in Korea
Ooo Performance simulation studies of a realistic model of the CBM Silicon Tracking System Silicon Tracking for CBM Reconstructed URQMD event: central.
Detector R&D for Muon Chamber Anand K. Dubey For VECC group.
Heavy ion irradiation on silicon strip sensors for GLAST S.Yoshida, K.Yamanaka, T.Ohsugi, H.Masuda T.Mizuno, Y.Fukazawa (Hiroshima Univ.) Y.Iwata, T.Murakami.
Minni Singla & Sudeep Chatterji Goethe University, Frankfurt Development of radiation hard silicon microstrip detectors for the CBM experiment Special.
1 Development of radiation hard microstrip detectors for the CBM Experiment Sudeep Chatterji GSI Helmholtz Centre for Heavy Ion Research DPG Bonn 16 March,
1 J.M. Heuser – CBM Silicon Tracking System Roadmap for the development of STS module demonstrators Concept Common interfaces/dimensions Some technical.
Heavy ion irradiation on silicon strip sensors for GLAST & Radiation hardening of silicon strip sensors S.Yoshida, K.Yamanaka, T.Ohsugi, H.Masuda T.Mizuno,
8 July 1999A. Peisert, N. Zamiatin1 Silicon Detectors Status Anna Peisert, Cern Nikolai Zamiatin, JINR Plan Design R&D results Specifications Status of.
News on microstrip detector R&D —Quality assurance tests— Anton Lymanets, Johann Heuser 12 th CBM collaboration meeting Dubna, October
CBM Silicon Tracking System. Microstrip Detector Module Assembly and Test V.M. Pugatch Kiev Institute for Nuclear Research GSI (CBM experiment), Darmstadt.
1 Device Simulations & Hardware Developments for CBM STS Sudeep Chatterji CBM Group GSI Helmholtz Centre for Heavy Ion Research CBM Collaboration Meeting,
Performance simulations with a realistic model of the CBM Silicon Tracking System Silicon tracking for CBM Number of integration components Ladders106.
1 J.M. Heuser − STS Development Microstrip detector GSI-CIS Johann M. Heuser, GSI Li Long, CIS CBM Collaboration Meeting, GSI, Update on.
Solid State Detectors for Upgraded PHENIX Detector at RHIC.
Radiation hardness of Monolithic Active Pixel Sensors (MAPS)
- Performance Studies & Production of the LHCb Silicon Tracker Stefan Koestner (University Zurich) on behalf of the Silicon Tracker Collaboration IT -
CBM Silicon Tracking System. First results of the detector module pre-prototype test. V.M. Pugatch Kiev Institute for Nuclear Research 11 th CBM Collaboration.
STS Radiation Environment 11 th CBM Collaboration Meeting GSI, February 2008 Radoslaw Karabowicz GSI.
1 J.M. Heuser − Status of the Silicon Tracking System Johann M. Heuser CBM Collaboration Meeting GSI Darmstadt, 12 March 2009 Status of the CBM Silicon.
Lehman Review April 2000 D. Bortoletto 1 Forward Pixel Sensors Daniela Bortoletto Purdue University US CMS DOE/NSF Review April 12,2000 Progress.
CBM Collaboration Meeting. GSI, Darmstadt CBM Silicon Tracking System. CBM-01 sensors characterization. V.M. Pugatch Kiev Institute for Nuclear.
Development of radiation hard Sensors & Cables for the CBM Silicon Tracking System Sudeep Chatterji On behalf of CBM-STS Collaboration GSI Helmholtz Centre.
Proportional chambers with cathode readout in high particle flux environment Michał Dziewiecki.
FIRST RESULTS OF THE SILICON STRIP DETECTOR at STAR Jörg Reinnarth, Jonathan Bouchet, Lilian Martin, Jerome Baudot and the SSD teams in Nantes and Strasbourg.
The CMS Silicon Strip Tracker Carlo Civinini INFN-Firenze On behalf of the CMS Tracker Collaboration Sixth International "Hiroshima" Symposium on the Development.
Albuquerque 1 Wolfgang Lohmann DESY On behalf of the FCAL collaboration Forward Region Instrumentation.
R. Lipton Vertex ‘98 Santorini, Greece The D0 Silicon Microstrip Tracker (D0SMT) Outline  Design  Detector Studies Coupling capacitors Radiation Damage.
A novel two-dimensional microstrip sensor for charge division readout D. Bassignana, M. Lozano, G. Pellegrini CNM-IMB (CSIC) M. Fernández, R. Jaramillo,
A novel two-dimensional microstrip sensor with charge division readout M. Fernández, R. Jaramillo, F.J. Muñoz, I. Vila IFCA (CSIC-UC) D. Bassignana, M.
ADC values Number of hits Silicon detectors1196  6.2 × 6.2 cm  4.2 × 6.2 cm  2.2 × 6.2 cm 2 52 sectors/modules896 ladders~100 r/o channels1.835.
The Silicon Tracking System of the CBM experiment FAIR 2014, Worms, October 2014 requirements and detector concept system performance prototype.
I.Rashevskaya- SVT Meeting - Frascati SuperB SVT Strip Pairing: impact on the capacitance value Irina Rashevskaya, Luciano Bosisio, Livio.
TCT measurements with strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko Mikuž 1,2, Marko.
Beam detectors in Au+Au run and future developments - Results of Aug 2012 Au+Au test – radiation damage - scCVD diamond detector with strip metalization.
0 Characterization studies of the detector modules for the CBM Silicon Tracking System J.Heuser 1, V.Kyva 2, H.Malygina 2,3, I.Panasenko 2 V.Pugatch 2,
Design and development of thin double side silicon microstrip sensors for CBM experiment Mikhail Merkin Skobeltsyn Institute of Nuclear Physics Moscow.
1 J.M. Heuser − STS R&D Johann M. Heuser, GSI CBM-STS Project Leader Meeting on Experiment with external HI beams of the Nuclotron-M JINR, 4 February 2011.
Making Tracks at DØ Satish Desai – Fermilab. Making Tracks at D-Zero 2 What Does a Tracker Do? ● It finds tracks (well, duh!) ● Particle ID (e/ separation,
The STS-module-assembly:
Karlsruhe probe equipment and QA proposals/expertise
Progress with System Integration of the CBM Silicon Tracking Detector
The workflow of module assembly for the CBM Silicon Tracking System
Position Sensitive TCT Measurements with 3D-stc detectors
Application of VATAGP7 ASICs in the Silicon detectors for the central tracker (forward part) S. Khabarov, A. Makankin, N. Zamiatin, ,
SuperB SVT Silicon Sensor Requirements
V.M. Pugatch Kiev Institute for Nuclear Research
Pradeep Ghosh for the CBM Collaboration Goethe-Universität, Frankfurt
Vertex Detector Overview Prototypes R&D Plans Summary.
Why silicon detectors? Main characteristics of silicon detectors:
Presentation transcript:

QA Tests Tests for each sensor Tests for each strip Tests for structures Process stability tests Irradiation tests Bonding & Module assembly Si detectors1272  6.2 × 6.2 cm  4.2 × 6.2 cm  2.2 × 6.2 cm sectors/modules1040 ladders106 r/o channels2.1 M r/o chips16.6 k r/o boards2080 hub boards180 Open Strip Shorted Strip “Pinhole” (short between implant and metal) Open bias resistor Open implant at via Open implant: Silicon Tracking System The Silicon Tracking System (STS) is the central detector of the Compressed Baryonic Matter (CBM) experiment at FAIR. Its task is the standalone trajectory reconstruction of the high multiplicities of charged particles originating from high- rate beam-target interactions. The silicon microstrip detectors must be radiation hard and are red out by a fast self-triggering front-end electronics. Quality Assurance Quality assurance for silicon sensor includes 1.Visual tests on arrival 2.Control & distribution to testing centers 3.Verification of specifications via tests 1.Electrical tests 1.Bulk IV & CV tests 2.Strip response 3.Inter-strip parameters 2.Radiation hardness tests 3.Bonding tests 4.Module tests 4.Central database for keeping track of sensor response Silicon microstrip sensors CBM01 1 st full-size prototype (2007) close-up of a corner of double-sided microstrip detector CBM01 (thickness 300 µm & strip pitch 58 µm) schematic view of silicon sensor with contacts pads & bias rail Strip Tests Electrical Tests Fig. 1. Counts v/s Channels pside nx0 Fig. 2. Counts v/s Channels pside nx2 Fig. 3. Distribution of Single Strip Amplitude Fig. 4. ADC without Baselines Laser Tests LED Tests With LED tests we investigate Sensor readout using infrared LED as light injector with FEE. Dead strips on sensor. LED’s used for sensors are: Infrared 1060nm (double sided) Red 660nm (single sided) Results shown are from a collimated 1060nm LED to a double sided silicon microstrip sensor illuminating 60 strips /side Pinhole testing schematic Pinhole test Scheme at Wafer prober Common strip failures & pinhole Semi-automatized using LabVIEW programs & Wafer prober Focuser CBM02 sensor Optical fiber Laser & optical fiber setup Laser Step Motor Focuser Optical Fiber Sensor ReadOut Station Box Interlock Optimization of focuser position With Laser tests we investigate Scanning sensor Strip integrity Detector response with mimicking 1MIP Charge sharing b/w strips Electrical tests include: 1.Bulk measurements 1.Leakage Current-Voltage (IV) 2.Capacitance-Voltage (CV) 2.Interstrip measurements 1.Resistance(Rint) 2.Capacitance (Cint) 3.Bias resistance (Rbias) 4.Coupling capacitance (Ccoup) 5.Current stability (IT) 6.Low Tempt. measurements Bulk capacitance Fig. 4. Lego plot of hit position : CBM02 Fig.3. Cluster amplitudes on nside: CBM02 Radiation damage Bias resistance Interstrip resistance Coupling capacitance Probe station Zuess 3000 Minimum Ionizing Particle (MIP) create ~ 22 ke - in our 300 µm thick silicon sensors, which corresponds to ≈ 180 ADC counts. The purpose of illuminating the double sided microstrip silicon sensor is to induce the same amount of charge as in case of a MIP. Based on the absorption of light in silicon, we selected infrared light (λ=1060 nm) which has absorption depth of ~500 µm in silicon. For the systematic evaluation of the performance of our sensors we used pulsed (~5 ns) infrared laser with a focused spot size ~15 µm. We have illuminated prototype sensor (256 strips/side) with the pulsed laser (~5 ns) and could focus the width of the laser spot to little more than one strip per side. The preliminary results are shown above. We are successful in inducing right amount of charge (22 ke - ). Fig. 3 shows a similar order of ADC counts as for MIPs. Cluster size is presented in Fig. 4. By illuminating a sensor by infrared light emitted by an LED it is possible to test the performance of all strips in one measurements. Fig. 1. ADC Counts/strip on nside: CBM02 Fig. 2. Cluster amplitude on nside: CBM02 Leakage current Quality assurance tests of silicon microstrip sensors for the CBM Experiment at FAIR Pradeep Ghosh, for the CBM Collaboration Goethe University, Frankfurt am Main, and GSI Helmholtz Center for Heavy Ion Research, Darmstadt