Rotating Coil Measurement Errors* Animesh Jain Superconducting Magnet Division Brookhaven National Laboratory, Upton, NY 11973, USA 2 nd Workshop on Beam.

Slides:



Advertisements
Similar presentations
Ramesh Gupta, BNL D1 Dipole Design / IR Magnet Study LARP Collaboration Meeting, Oct 5-6, D1 Dipole Design Task (terminated in 2005) IR Magnet Study.
Advertisements

Field measurements of QEA magnets at KEK Mika Masuzawa May 30, 2006.
BROOKHAVEN SCIENCE ASSOCIATES Abstract Vibrating Wire R&D for Magnet Alignment Animesh Jain, NSLS-II Project The alignment tolerance for a string of magnets.
Characteristics of Instruments P M V Subbarao Professor Mechanical Engineering Department A Step Towards Design of Instruments….
5/18/2015J-PARC1 High Level Physics Applications Magnets & Beams Day ?, Lecture ? Accelerator View from the Physicist.
Fall 2008Physics 231Lecture 7-1 Magnetic Forces. Fall 2008Physics 231Lecture 7-2 Magnetic Forces Charged particles experience an electric force when in.
22-Nov-2004 © Renishaw plc Not to be reproduced without written permission from Renishaw Laser & Calibration Products Division Slide 1 Laser.
Alignment of DB and MB quadrupoles Hélène MAINAUD DURAND 17/11/2011 With a lot of input from Sylvain GRIFFET.
Isaac Vasserman Magnetic Measurements and Tuning 10/14/ I. Vasserman LCLS Magnetic Measurements and Tuning.
Lab #2: Magnetic Fields due to Currents
A U.S. Department of Energy Office of Science Laboratory Operated by The University of Chicago Argonne National Laboratory Office of Science U.S. Department.
Classification of Instruments :
BROOKHAVEN SCIENCE ASSOCIATES Abstract Role of Magnetic Measurements in Magnet Production Animesh Jain, NSLS-II Project The role played by magnetic measurements.
1 BROOKHAVEN SCIENCE ASSOCIATES NSLS-II Stability Workshop April , 2007 NSLS-II Electrical Systems G. Ganetis NSLS-II Electrical Systems NSLS-II.
BROOKHAVEN SCIENCE ASSOCIATES Abstract Magnetic Specifications and Tolerances Weiming Guo, NSLS-II Project In this presentation I briefly introduced the.
Topic 1 different attributes that characterize sensors ETEC 6405.
19 Nov 08,ILC08Cherrill Spencer Rotating Coil System Description 1 Short description of the SLAC rotating coil system used to measure the CIEMAT-made prototype.
1 / 19 M. Gateau CERN – Geneva – CH 14th International Magnetic Measurement Workshop September 2005, Geneva, Switzerland.
Rotating Coils - Giordana Severino – Rotating Coils PACMAN meeting Printed Circuit Coils – Future developments.
WP2 ESR 2.2 WP2 ESR2.2 Giordana Severino PACMAN WORKSHOP - CERN PCB technology for small diameter field sensing.
Respected Professor Kihyeon Cho
SENSORS MEETING THE NEEDS OF THE DAY  A device which converts energy or information in one form to another  In other words, a device which provides.
Alignment and Beam Stability
Vector Control of Induction Machines
The HiLumi LHC Design Study is included in the High Luminosity LHC project and is partly funded by the European Commission within the Framework Programme.
A Mathematical Analysis of a Sun Tracking Circuit for Photovoltaic Systems Dr. S. Louvros and Prof. S. Kaplanis T.E.I. of Patra, Greece.
LECTURER PROF.Dr. DEMIR BAYKA AUTOMOTIVE ENGINEERING LABORATORY I.
Lecture 5 Jack Tanabe Old Dominion University Hampton, VA January 2011 [1] Halbach, K., FIRST ORDER PERTURBATION EFFECTS IN IRON-DOMINATED TWO- DIMENSIONAL.
Energy calibration at LHC J. Wenninger. Motivation In general there is not much interest for accurate knowledge of the momentum in hadron machines. 
Bnl - fnal- lbnl - slac US LHC Accelerator Research Program A Quadrupole Design for Crab Cavity Optics Ramesh Gupta Brookhaven National Laboratory Upton,
Magnet Measurement for the Hall A Compton Dipole Ken Baggett
1 J.DiMarco 16Nov2010 LQS01b Magnetic Measurements Results ( preliminary ) J. DiMarco 16Nov2010.
Optimization of Field Error Tolerances for Triplet Quadrupoles of the HL-LHC Lattice V3.01 Option 4444 Yuri Nosochkov Y. Cai, M-H. Wang (SLAC) S. Fartoukh,
Analysis of Multipole and Position Tolerances for the ATF2 Final Focus Line James Jones ASTeC, Daresbury Laboratory.
CLIC Beam Physics Working Group CLIC pre-alignment simulations Thomas Touzé BE/ABP-SU Update on the simulations of the CLIC pre-alignment.
Magnetic Metrology of SOLEIL Synchrotron S.R. Multipoles IMMW 14, A. Madur Magnetic Metrology of SOLEIL Synchrotron Storage Ring Multipoles A. Dael, P.
Measurements Measurements and errors : - Here, the goal is to have some understanding of the operation and behavior of electrical test instruments. Also,
Magnetic Field Stability Measurements Joe DiMarco 23Oct07.
Main Linac Tolerances What do they mean? ILC-GDE meeting Beijing Kiyoshi Kubo 1.Introduction, review of old studies 2.Assumed “static” errors.
Booster corrector measurement QA Phil Schlabach 1 May 2007 Proton Source Magnet Meeting.
MCZ Magnetic Allignment of Coils for NCSX M.C. Zarnstorff 11 December 2006.
Presentation 7/05/2015 Giordana Severino ESR2.2, WP2 CERN Supervisors Marco Buzio Academic supervisor Prof. Pasquale Arpaia.
Lecture 7 Jack Tanabe Cornell University Ithaca, NY Magnetic Measurements.
Warm-Cold Changes in the Sextupole Harmonic in the Quadrupole Magnets for the BEPC-II Luminosity Upgrade Animesh Jain Brookhaven National Laboratory Upton,
Physics Requirements Sensitivity to Manufacturing Imperfections Strategy  where to map field  measure deviation from ideal model  fit to error tables.
Measurement of LHC Superconducting Dipole and Quadrupole Magnets in Ramp Rate Conditions G.Deferne, CERN Aknowledgements: M. Di Castro, S. Sanfilippo,
Magnet Alignment Challenges for an MBA Storage Ring* Animesh Jain Superconducting Magnet Division Brookhaven National Laboratory, Upton, NY 11973, USA.
1 Magnetic measurements of the Super-FRS magnets 1 Overview: - Measurement systems for dipoles - requirements - Measurement systems review - Open points.
Beam dynamics simulations with the measured SPARC gun- solenoid field G. Bazzano, P. Musumeci, L. Picardi, M. Preger, M. Quattromini, C. Ronsivalle, J.
CERN –GSI/CEA MM preparation meeting, Magnetic Measurements WP.
Midterm Review 28-29/05/2015 Progress on wire-based accelerating structure alignment Natalia Galindo Munoz RF-structure development meeting 13/04/2016.
WU Lei,WANG Xiaolong, LI Chunhua, QU Huamin Mechanical Group, Accelerator Division Institute of High Energy Physics 13 th International Workshops on Accelerator.
DDBA magnets Chris Bailey Low emittance rings Sept Frascati.
Yingshun Zhu Design of Small Aperture Quadrupole Magnet for HEPS-TF
Threading / LTC/ JW1 How difficult is threading at the LHC ? When MADX meets the control system … J. Wenninger AB-OP &
Magnetic Measurements At SLAC
Tutorial On Fiducialization Of Accelerator Magnets And Undulators
Tolerances & Tuning of the ATF2 Final Focus Line
For Discussion Possible Beam Dynamics Issues in ILC downstream of Damping Ring LCWS2015 K. Kubo.
Advanced Photon Source Upgrade Project:
Optimization of Triplet Field Quality in Collision
CHEN, Fusan KANG, Wen November 5, 2017
Brookhaven National Laboratory Upton, New York , USA
SCU Next Phase Meeting July 8, 2014.
Paige Thielen, ME535 Spring 2018
FNAL Superconducting Quadrupole Test
Department of Physics 1st year Laboratory
Magnetic axis tolerances for the SSS magnets
Beam dynamics requirements on MQT
Propagation of Error Berlin Chen
Presentation transcript:

Rotating Coil Measurement Errors* Animesh Jain Superconducting Magnet Division Brookhaven National Laboratory, Upton, NY 11973, USA 2 nd Workshop on Beam Dynamics Meets Magnets (BeMa2014) December 1-4, 2014 Park Hotel, Bad Zurzach, Switzerland * Work supported by the U.S. Department of Energy under contract DE-AC02-98CH10886

Introduction Rotating Coil Measurement Errors: Animesh Jain, BNL Beam Dynamics Meets Magnets-II, Dec. 1-4, 2014, Bad Zurzach 1 Rotating coils are unmatched in their ability to accurately measure higher order field harmonics in accelerator magnets. Rotating coils also provide a means of measuring the strength of the main harmonic term ( transfer function and roll angle ), simultaneously with the measurement of higher order terms. With “good” systems, the measurements can be repeatable over long time periods (~0.01% for the main harmonic, ~10 ppm for higher order terms) Good for monitoring production. Errors can arise in these measurements due to imperfections in fabrication, calibration and rotation of the measuring coil. The possible sources of errors will be reviewed in this talk.

What is a Rotating Coil? Rotating Coil Measurement Errors: Animesh Jain, BNL Beam Dynamics Meets Magnets-II, Dec. 1-4, 2014, Bad Zurzach 2 It is essentially a loop of wire of certain geometry, rigidly held in place by a support bobbin, that is rotated in the aperture of the magnet being measured. (Can the bobbin be omitted?) The flux intercepted by the loop is measured as a function of angular position, which is then converted into field harmonics. Commonly used geometries are “Radial” and “Tangential” coils. Radial Tangential

Sources of Measurement Errors Rotating Coil Measurement Errors: Animesh Jain, BNL Beam Dynamics Meets Magnets-II, Dec. 1-4, 2014, Bad Zurzach 3 Small deviations of as-built loop geometry from the design. This affects the sensitivity to various harmonics, and thus the conversion from flux to harmonics. –Can be taken care of by a detailed calibration of the as-built coil. –All coils must be treated as neither pure “radial” nor “tangential”. Data acquisition system errors (integrators, voltmeters, angle encoders, tilt sensors, current transducers, …) –Use good quality components, calibrate frequently. Rotational imperfections (transverse and torsional vibrations) of the rotating coil Most important for higher order harmonics. – Need good “bucking” for immunity to such imperfections.

Typical Construction & Placement Errors Rotating Coil Measurement Errors: Animesh Jain, BNL Beam Dynamics Meets Magnets-II, Dec. 1-4, 2014, Bad Zurzach 4 Random variation in coil radius: Random variation in coil angular position: Random variation in (tangential) coil opening angle: Tilt in measuring coil axis (in axially uniform field): K n = Sensitivity to 2n -pole term ( n = 1 is Dipole) (B n,A n ) = 2n -pole Normal & Skew

Coil Construction Errors Rotating Coil Measurement Errors: Animesh Jain, BNL Beam Dynamics Meets Magnets-II, Dec. 1-4, 2014, Bad Zurzach 5 Most coil construction errors (within reasonable limits) affect the measurement of harmonics at the level of a few percent or less. For magnets with good field quality, this is generally not a serious limitation for the higher harmonics (5% of 1 “unit” = 0.05 unit). The main field, however, may require much better accuracy than a few percent (better than 0.1%, say). –An independent calibration of the main field is required. – Calibration is dependent on magnet size and axial placement due to axial non-uniformity in coil construction. –Both field strength and roll angle calibration must be carried out in a magnet of similar characteristics (length and axial profile).

Axial Variations in Coil Construction Rotating Coil Measurement Errors: Animesh Jain, BNL Beam Dynamics Meets Magnets-II, Dec. 1-4, 2014, Bad Zurzach 6 Magnetic length = 0.16 m Measuring coil length = 1.0 m Radius = 27.4 mm (I.T.F = Integrated Transfer Function) ±0.1% ITF error ~ ±14  m radius error 24-Oct-2006

Axial Variations in Coil Construction Rotating Coil Measurement Errors: Animesh Jain, BNL Beam Dynamics Meets Magnets-II, Dec. 1-4, 2014, Bad Zurzach 7 Magnetic length = 0.16 m Measuring coil length = 1.0 m Radius = 27.4 mm 10  m azimuthal error ~ 0.4 mr angle error. It is clear that specific section must be calibrated to achieve < 0.1 mr error 24-Oct-2006

Coil Transverse Placement Errors Rotating Coil Measurement Errors: Animesh Jain, BNL Beam Dynamics Meets Magnets-II, Dec. 1-4, 2014, Bad Zurzach 8 The axis of rotating coil may have an offset and a tilt relative to the magnetic axis of the magnet being measured. Any transverse offset leads to feed down terms, which can in fact be used to derive the offset. The measured data can be easily corrected for this offset. (precise alignment is not necessary) A tilt of the axis, on the other hand, causes only second order feed down, and is generally negligible, except in the case of –Measuring sextupoles, or higher order multipole magnets, where the main field can produce strong 2 nd order feed down terms. –Magnets with asymmetric axial profiles (e.g. lead end differing from non-lead end), where 1 st order feed down does not cancel.

Transverse Vibrations Rotating Coil Measurement Errors: Animesh Jain, BNL Beam Dynamics Meets Magnets-II, Dec. 1-4, 2014, Bad Zurzach 9 The effect of transverse vibrations in a 2n -pole magnet can be minimized by using a coil system whose sensitivity to the (n -1)th harmonic is zero. The coil is displaced from the ideal position by a vector D (  ) when the coil rotates through . In a pure 2 n -pole field, the amount of spurious harmonics in the coil signal is roughly proportional to the sensitivity of the coil to the ( n –1)th harmonic.

Torsional Errors Rotating Coil Measurement Errors: Animesh Jain, BNL Beam Dynamics Meets Magnets-II, Dec. 1-4, 2014, Bad Zurzach 10 The effect of torsional errors in measuring a 2n -pole magnet can be minimized by using a coil system whose sensitivity to the n -th harmonic is zero. The coil angular position is  + T (  ) when it should have been . In a pure 2 n -pole field, the amount of spurious harmonics in the coil signal is roughly proportional to the sensitivity of the coil to the n- th harmonic.

Implementation of Bucking Rotating Coil Measurement Errors: Animesh Jain, BNL Beam Dynamics Meets Magnets-II, Dec. 1-4, 2014, Bad Zurzach 11 For precise measurements of harmonics, all rotating coils must implement bucking. This is often done by adding one or more loops of wire to the coil, in addition to a “main” coil. The additional loops are so chosen that a suitable combination of them (generally a simple sum) has the same sensitivity as the “main” coil for the harmonics to be bucked. Analog bucking: all coils are suitably connected in series such that harmonics to be bucked are cancelled out. This requires precise fabrication of various loops in the rotating coil. – The “bucking ratio” for feed down term is often overlooked! Digital bucking: all signals are digitized first, then summed –Allows weight factors to be adjusted; requires good DAQ system.

Validating Harmonics Measurements Rotating Coil Measurement Errors: Animesh Jain, BNL Beam Dynamics Meets Magnets-II, Dec. 1-4, 2014, Bad Zurzach 12 Errors in higher harmonics caused directly by coil fabrication tolerances are generally small, and can be neglected. But even small construction errors may significantly affect the quality of bucking when analog bucking is used. This is often the most important cause of unreliable field harmonics data. It is important to validate a measurement system for accuracy, particularly if magnets are to be shimmed to meet stringent field quality requirements. (Errors may lead to incorrect shimming!) It is generally not easy to verify accuracy because there is nothing against which the measurements may be compared. –Need for “well characterized” reference magnets. –Use consistency under coordinate transformations for cross-check.

In the Absence of Reference Magnets … Rotating Coil Measurement Errors: Animesh Jain, BNL Beam Dynamics Meets Magnets-II, Dec. 1-4, 2014, Bad Zurzach 13 It is very difficult to prove beyond doubt that a given set of measurements are accurate enough. However, certain tests may be performed to look for signs of problems. Measurements could be made with the magnet installed in both the normal orientation, as well as flipped end-for-end. Systematic errors in harmonics that should change sign with respect to the main field (e.g. b3, a4, b5,.. in a quadrupole, or b4, a5, b6,.. in a sextupole) can be detected by comparing the two sets of measurements. If available, measurements could be made using two independent systems, preferably with windings of different designs. Best approach is to build redundancy in the measuring coil such that several independent measurements are made simultaneously. (Example: BNL 9-winding coil design using digital bucking) ( n = 1 is Dipole)

BNL “ 9-Tangential ” Coil Design (IMMW16) Rotating Coil Measurement Errors: Animesh Jain, BNL Beam Dynamics Meets Magnets-II, Dec. 1-4, 2014, Bad Zurzach deg., 36 Turns “Main” coil. 16 turns in each of the six bucking windings. 18 grooves needed. Minimum groove separation is 12 deg. (quite comfortable). Coil parameters are manually optimized to ensure applicability to all magnet types. (12 free parameters) Very simple end design (No overlapping turns, except DB). Only 7 windings are essential. Dipole windings were added to help with calibration, but are also useful in providing more flexibility in measurements.

BNL 9-winding Coil Design Rotating Coil Measurement Errors: Animesh Jain, BNL Beam Dynamics Meets Magnets-II, Dec. 1-4, 2014, Bad Zurzach 15 7 Tangential coils of different opening angles 2 “ Dipole ” windings (180 deg. Opening angle Tangential coils) Any combination of 5 windings can buck out any two arbitrarily chosen harmonics – same coil can be used for ALL magnet types. Any combination of 7 windings can buck out any three harmonics (e.g. dipole, quad, sextupole) – suitable for measuring multiple magnets together, e.g. for interference effects. There are up to 126 ways to pick 5 windings out of 9 available. One can pick the most favorable combinations for each harmonic. Equivalent to measuring the magnet with many different coil designs simultaneously. This allows an estimation of measurement accuracy. For details, please see: A. Jain, A New Versatile Rotating Coil Design Using Multiple Tangential Windings and Digital Bucking, IMMW-16, Oct , 2009

Measurement of Main Field Component Rotating Coil Measurement Errors: Animesh Jain, BNL Beam Dynamics Meets Magnets-II, Dec. 1-4, 2014, Bad Zurzach 16 The strength and roll angle of the main field is the quantity of most interest that needs to be measured as accurately as possible (Strength better than ±0.1%, angle better than ±0.1 mr). Strength calibration needs to be done against absolute measurements using other techniques, such as Hall probes, stretched wires, or NMR. Such a calibration must be carried out in magnets of the same type, length and field profile. (To account for axial non-uniformity of coil construction.) It should be possible to calibrate the absolute strength at the level of ~0.05% in magnets with not too small an aperture. If the rotating coil installation needs it to be removed from the drive, then special coil geometries should be used (e.g. J. DiMarco, IMMW15). Roll angle calibration needs to be performed almost daily to ensure measurement accuracies of better than ±0.1 mr (calibration drifts easily).

Calibration of Quadrupole Strength Rotating Coil Measurement Errors: Animesh Jain, BNL Beam Dynamics Meets Magnets-II, Dec. 1-4, 2014, Bad Zurzach NSLS-II quadrupoles of 6 different types measured with a Hall probe at several currents. Hall probe was calibrated against NMR in a dipole magnet. Variation ±0.07%

Calibration of Quadrupole Strength Rotating Coil Measurement Errors: Animesh Jain, BNL Beam Dynamics Meets Magnets-II, Dec. 1-4, 2014, Bad Zurzach NSLS-II quadrupoles of 6 different types measured with a Hall probe at several currents. Hall probe was calibrated against NMR in a dipole magnet.

Magnetic Measurement of Roll Angle Rotating Coil Measurement Errors: Animesh Jain, BNL Beam Dynamics Meets Magnets-II, Dec. 1-4, 2014, Bad Zurzach 19 Measurement frame is defined by the index pulse from the angle encoder. One needs angular positions of windings in this frame. Calibration establishes the coil winding angles relative to the angle encoder index pulse as present at the time of calibration. Gravity ties the measurement frame to the magnet fiducials. Error in roll angle measurement can occur due to drift of gravity sensor offset and slippage in the drive shaft coupling.

Roll Angle Measurement Error Correction Rotating Coil Measurement Errors: Animesh Jain, BNL Beam Dynamics Meets Magnets-II, Dec. 1-4, 2014, Bad Zurzach 20 View from one end: True Roll Angle =  Meas. Roll Angle =     View from opposite end: True Roll Angle = –  Meas. Roll Angle = –   True Roll Angle =   –    Meas. Error =   +   

Uncertainty in Roll Angle Error Correction Rotating Coil Measurement Errors: Animesh Jain, BNL Beam Dynamics Meets Magnets-II, Dec. 1-4, 2014, Bad Zurzach 21 Noise in each measurement ~ 0.03 mrad Resolution of gravity sensors ~ 0.02 mrad Total error ~ ±0.05 mrad can be achieved with careful measurements. Note that 0.05 mrad over a shaft of 20 mm diameter amounts to a slippage of only 0.5 micron! (removable coil connections?) Due to very small mechanical shifts needed to cause even large roll angle measurement errors, it is necessary to determine the roll angle correction for every magnet measured in order to ensure reliable measurements (at least once per day).

Various Roll Measurements in ERQ106 Rotating Coil Measurement Errors: Animesh Jain, BNL Beam Dynamics Meets Magnets-II, Dec. 1-4, 2014, Bad Zurzach 22 End-for-end measurements are very effective in correcting roll angle measurement offsets.

Summary Rotating Coil Measurement Errors: Animesh Jain, BNL Beam Dynamics Meets Magnets-II, Dec. 1-4, 2014, Bad Zurzach 23 Reasonable coil construction and placement errors generally do not affect harmonics measurements directly (i.e. via sensitivity). Primary reason for unreliable harmonics measurements is poor analog bucking due to even small construction errors. Bucking of feed down term should not be overlooked. Digital bucking can offer an advantage in terms of relaxed construction tolerances, but requires good data acquisition. Calibration of main field strength and roll angle must be done for the specific section of a rotating coil that is in magnetic field. Roll angle calibration tends to drift easily and must be checked almost daily for reliable roll angle measurements.