EQUIPMENT and METHOD VALIDATION

Slides:



Advertisements
Similar presentations
Supplementary Training Modules on Good Manufacturing Practices
Advertisements

Dr. Birgit Schmauser, BfArM, Bonn
Analytical Method Development and Validation
Instrumental Analysis
Calibration methods Chemistry 243.
Integrated Method Development and Validation Dr. Ludwig Huber RACI Conference - Chemical Analyses.
PHARM 462 PART / /31 Good Manufacturing Practices (GMP) VALIDATION of ANALYTICAL TEST METHODS.
World Health Organization
Training Workshop on Pharmaceutical Development with a Focus on Paediatric Medicines / October |1 | Pharmaceutical Development Analytical.
Accreditation & Validation
Validation of Analytical Methods
Supplementary Training Modules on Good Manufacturing Practice
Validation of analytical methods
ASEAN GUIDELINES FOR VALIDATION OF ANALYTICAL PROCEDURES
QUALITY CONTROL OF PHYSICO-Chemical METHODS Introduction :Validation توثيق المصدوقية.
Chemometrics Method comparison
Quality Assessment 2 Quality Control.
Instrumental Analysis
Professor Abdul Muttaleb Jaber Professor Abdul Muttaleb Jaber Faculty of Pharmacy Faculty of Pharmacy Office: Room # 512 (Faculty of Pharmacy) Office:
Validation: concept, & considerations
Validation of Analytical Method
Laboratory Validation of Analytical Methods
WELCOME. UV Spectrophotometric Method Development And Estimation of Bicalutamide in Pharmaceutical Dosage Form.
Simultaneous quantification of bergenin, catechin, and gallic acid from Bergenia ciliata and Bergenia ligulata by using thin-layer chromatography 张 慧.
The following minimum specified ranges should be considered: Drug substance or a finished (drug) product 80 to 120 % of the test concentration Content.
Analytical considerations
Biostatistics: Measures of Central Tendency and Variance in Medical Laboratory Settings Module 5 1.
Chapter 5 Errors In Chemical Analyses Mean, arithmetic mean, and average (x) are synonyms for the quantity obtained by dividing the sum of replicate measurements.
Quality Control Lecture 5
Budi Hastuti, S.Pd., M.Si.. INTRODUCTION  Two step analysis: 1. Identify  Qualitative Analysis 2. Estimation  Quantitative Analysis Method  Classical.
Quality Assurance How do you know your results are correct? How confident are you?
5. Quality Assurance and Calibration Quality assurance is We do to get the right answer for our purpose. Have Sufficient accuracy and precision to support.
STABILITY TESTING Dr. Laila Khairy PhD, Chairman, NODCAR NATIONAL ORGANIZATION FOR DRUG CONTROL AND RESEARCH Dr. Laila Khairy PhD, Chairman, NODCAR NATIONAL.
1 Exercise 7: Accuracy and precision. 2 Origin of the error : Accuracy and precision Systematic (not random) –bias –impossible to be corrected  accuracy.
Introduction The importance of method validation
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
10 May Understanding diagnostic tests Evan Sergeant AusVet Animal Health Services.
Lect Eli Solomon M.Sc 1 VALIDATION PRINCIPLES Principles of qualification and validation which are applicable to the manufacture of medicinal.
Wenclawiak, B.: Fit for Purpose – A Customers View© Springer-Verlag Berlin Heidelberg 2003 In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in.
Industrial Technology Institute Test Method Validation & Verification H.P.P.S.Somasiri Principal Research Scientist / SDD-QAD /QM Industrial Technology.
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
Lecture 10 ANALYTICAL METHOD DEVELOPMENT AND VALIDATION IN HPLC AND GC. Lecture 10 – Chromatography, Dr. Rasha Hanafi 1© Dr. Rasha Hanafi, GUC.
ISO 9000&14000 and validation. INTRODUCTION I S O I S O International Standard Organization ISO in Greek means “equal” and ISO wanted to convey the idea.
Validation of the AOAC method for pesticides residues analysis in oranges and mandarins in LATU Marina Torres (1) 1, Lucía Alcarraz 1 (2) 1 Laboratorio.
SEMINAR ON PRESENTED BY BRAHMABHATT BANSARI K. M. PHARM PART DEPARTMENT OF PHARMACEUTICS AND PHARMACEUTICAL TECHNOLGY L. M. COLLEGE OF PHARMACY.
Chapter 5 Quality Assurance and
means to “TO CHECK OR PROVE THE VALIDITY OF” According to FDA – “ The goal of validation is to establish a documented evidence which provides a high degree.
이 장 우. 1. Introduction  HPLC-MS/MS methodology achieved its preferred status -Highly selective and effectively eliminated interference -Without.
Method Validation-where do I start?
VALIDATION PRINCIPLES
Multi-Analyte LC-MS/MS Methods – Best Practice.
James Byrd, Marta Kozak 28 Apr 2011
Course: BioT 006 Quality Control & Validation
VALIDATION OF PHARMACEUTICAL PROCESSES
World Health Organization
World Health Organization
1 2 3 INDIAN INSTITUTE OF TECHNOLOGY ROORKEE PROJECT REPORT 2016
Dr. Birgit Schmauser, BfArM, Bonn
This teaching material has been made freely available by the KEMRI-Wellcome Trust (Kilifi, Kenya). You can freely download,
Analytical Method Validation
Chapter 5 Quality Assurance and Calibration Methods
Choice of Methods and Instruments
Режа: 1. Метрология тушунчаси 2. Валидация
ANALYTICAL METHOD VALIDATION
World Health Organization
Satish Pradhan Dnyanasadhana College, Thane. Department of Chemistry S
Quality Control Lecture 3
Introduction to Analytical Chemistry
Quality Assessment The goal of laboratory analysis is to provide the accurate, reliable and timeliness result Quality assurance The overall program that.
Damiana Gentili Qualified Person/QU Director 09/05/2019
Presentation transcript:

EQUIPMENT and METHOD VALIDATION

“Methods validation is the process of demonstrating that analytical procedures are suitable for their intended use”

Parameters of Method Validation Linearity Accuracy (also termed trueness) Precision (reproducibility) Robustness Specificity (selectivity) Limit of detection Limit of quantitation

Specificity Ability to assess the analyte in the presence of components which may be expected to be present . To determine the specificity of the methods, monitor by analyzing the placebo, standard solution and market preparation containing drugs. No peak should be detected close to the retention time/λmax/IR, NMR, MS absorbance of the drug proving the high degree of specificity of the method.

Linearity Ability to obtain test results which are directly proportional to the concentration of analyte in the sample Aspects: To evaluate linearity by visual inspection of the plot and by statistical techniques To calculate correlation coefficient, y-intercept, slope Linearity: Prepare a set of a minimum of 5 concentrations of analyte standard. Perform the determination and generate a standard curve. Acceptance Criteria: Linear Regression Coefficient of Determination (r²) = 0.995 to 1.

Accuracy/ Recovery The accuracy of an analytical method expresses the nearness between the expected value and the value found. There are guidelines as to how the accuracy should be evaluated. For eg- in case of HPLC technique- - Accuracy should be assessed by 9 determinations over a minimum of 3 concentration levels -To be reported as percent recovery (R%) [R% = % Recovery = (Recovered Conc./Injected Conc.) x 100] Acceptance Criteria: 97.0% - 103.0% recovery for raw APIs 95.0% - 105.0% for finished dosage forms.

Precision/ Reproducibility The precision of an analytical method is the closeness of agreement among individuals test result of the same homogeneous sample under prescribed conditions where the method is applied repeatedly. Expressed as RSD % There are guidelines as to how the accuracy should be evaluated. For eg- in case of HPLC technique- [RSD (%) = (Standard deviation/Mean) x 100 %], Std Deviation = [(Std. conc.- Recovered conc.)/Std. conc.] Acceptable Range: RSD ≤ 2 %.

Precision is usually investigated at three levels: repeatability, intermediate precision, and reproducibility. Repeatability (Precision). Repeatability is a measure of the precision under the same operating conditions over a short interval of time. It is sometimes referred to as intraday precision. A minimum of nine determinations covering the specified range for the procedure (e.g., three concentrations/three replicates as in the accuracy experiment) Intermediate Precision. Intermediate precision is defined as the variation within the same laboratory. It is sometimes referred to as interday precision. Typical parameters that are investigated include day-to-day variation, analyst variation, and equipment variation. Reproducibility. Reproducibility measures the precision between laboratories as in collaborative studies. This parameter should be considered in the standardization of an analytical procedure.

Robustness The robustness of an analytical procedure is a measure of its capacity to remain unaffected by small but deliberate variations in the analytical procedure parameters. The robustness of the analytical procedure provides an indication of its reliability during normal use.

Limit of Detection (LOD): For chromatographic method, determine the minimum level at which a compound can be detected, using analyte solutions of decreasing concentration. LOD is generally defined as 3 times the noise level. Other scientifically-sound approaches may also be used. For other types of methods, estimate through visual evaluation the minimum level at which a compound can be detected, using analyte solutions of decreasing concentration. Limit of Quantitation (LOQ): For chromatographic method, determine the minimum level at which a compound can be quantitated, using analyte solutions of decreasing concentration. LOQ is generally defined as 10 times the noise level. For other types of methods, estimate through visual evaluation the minimum level at which a compound can be quantitated, using analyte solutions of decreasing concentration.

Typical variations affecting a method’s reproducibility are: · Differences in room temperature and humidity; · Operators with different experience and thoroughness; · Equipment with different characteristics for eg- different injection modes; · Variations in material and instrument conditions, for example different protocols of the mobile phases preparation; changes in composition, pH, flow rate of mobile phase in case of HPLC; · Equipments of different ages; · Columns from different suppliers or different batches; · Solvents, reagents and other material with different quality

Thank You