BREATHING SYSTEMS.

Slides:



Advertisements
Similar presentations
INHALATION ANAESTHESIA BREATHING SYSTEMS Prepare and monitor anaesthesia in animals INHALATION ANAESTHESIA BREATHING SYSTEMS.
Advertisements

The Ideal Breathing System
Positive pressure ventilation Ventilation of the lungs single most important and most effective step in cardiopulmonary resuscitation of the compromised.
ANESTHETIC MACHINES.
Anesthesia Machine Presented by Gil Soto C.R.N.A.
AMIR SALAH MODERN ANAESTHETIC MACHINE MODERN ANAESTHETIC MACHINE 1 of 4.
Use of the Inhalant Anesthetic Machines
Oxygen Administration R/C MERT Medic Assistant Lesson V.
Check Valves and Manufacturer-Recommended Leak Test
Scavenging System  To reduce exposure to waste anesthetic gases  Can be active or passive scavenging system Active Scavenging System  Connected to a.
Nitric Oxide Set-up for Patients on Ventilator
Anesthetic Equipment.
Clinical Conference: Technology Rounds Biomedical Engineering Evelyn Fan, M.H.Sc., Clinical Engineer Biomedical Engineering November 2, 2005.
Oxygen Delivery Devices they’re not what you think.
AMIR SALAH MODERN ANAESTHETIC MACHINE MODERN ANAESTHETIC MACHINE 4 of 4.
BSAC Sports Diver Training
Requirements for Gas Exchange moist membrane surface area respiratory medium Air Water.
Clinical Conference Anesthesia Machines don ’ t fail, do they? James H. Philip M(E)E, MD Brigham and Women’s Hospital October 30, 2002 © Copyright 2002,
By Dr. Ahmed Mostafa Assist. Prof. of anesthesia and I.C.U.
PART 3: Breathing Circuit
AHP300 VENTILATOR Prepared by Caesar Rondina, EMTP, SCT, EMTP, CES
Parts of the Anesthetic Machine
The Anesthesia Gas Machine
Oxygen Use and the CNA. Signs and Symptoms to Report Unusual skin color Unusual color of lips, mucous membranes, nail beds Cool, clammy skin Slow, rapid.
A). When the carrier gas is quickly switched to 100% nitrous oxide (B). the halothane concentration decreases to 3% within 8 to 10 seconds A new steady-state.
Anesthesia Breathing Systems
Inhaled anesthetic Delivery Systems
Scavenging System A&A Pg 356  To reduce exposure to waste anesthetic gases  Can be active or passive scavenging system Active Scavenging System  Connected.
Endotracheal tubes Made of either rubber, vinyl plastic, or silicone plastic rubber tubes (red color) dry and crack over time with exposure to disinfectant.
+ Surgical Procedures 7.01 Implement techniques to prepare and monitor patients for surgery.
Anesthetic Breathing Circuits
To Menu.
Non-Rebreathing System  Used for patients weighing < 7 kg  Attach the clear, plastic hose to the fresh gas inlet (this tube comes from the vaporizer.
Breathing systems and the anaesthetic machine Zsolt Molnár SZTE, AITI.
SureVent 2 - SV2® Gas Powered Automatic Ventilation Resuscitator
AMIR SALAH MODERN ANAESTHETIC MACHINE MODERN ANAESTHETIC MACHINE 2 of 4.
Humidity Therapy and Humidifiers
Introductory Lecture Series: The Anesthesia Machine
Waste Anesthetic Gases. The anesthetic gas and vapors that leak out into the surrounding room during medical and surgical procedures are considered waste.
The Relative Exposure of the Operating Room Staff to Sevoflurane During Intracerebral Surgery Anesth Analg 2009;109:
Know your Os? How much Oxygen is the patient on? How much does the patient need? How’s this mask work? Is this thing hooked up right?
Oxygenation And Ventilation
ANAESTHESIA BREATHING CIRCUITS
Breathing systems and the anaesthetic machine Zsolt Molnár SZTE, AITI
Understanding Mapleson Circuits
PART 3: Breathing Circuit
To Menu.
Anesthetic Problems and Emergencies A&A pg Why Do Problems Arise?  Human error  Equipment error  Adverse effects  Patient factors  Anesthetic.
Introduction of low- flow anesthesia 麻醉科 R2 楊美惠 2004/11/08.
VNTE Prep Anesthetic Review.
1 Copyright © 2011, 2003, 2000, 1994 by Mosby, Inc., an affiliate of Elsevier Inc. Veterinary technicians must be familiar with the human safety considerations.
Anesthesia Machine Circuits
Ventilators Tuesday, 20 April 2004 Bill McCulloch.
Prepared by Dr. Irene Roco
Parts of the Anesthetic Machine A&A Pages
PART 3: Breathing Circuit
Intubation and Anesthetic Machines
Introductory Lecture Series: The Anesthesia Machine
AMIR SALAH MODERN ANAESTHETIC MACHINE MODERN ANAESTHETIC MACHINE 3 of 4.
Veterinary Anesthesia
PART 3: Breathing System Parts
Anesthesia Equipment Session 3
Non-Rebreathing System
Parts of the Anesthetic Machine Parts 1 & 2: A&A pages
Anesthetic Gas Machines
Non-Rebreathing System
The Anaesthesia Machine
Breathing Systems Tom Williams.
Transport Ventilator and Beyond!
The problem – The solution
Presentation transcript:

BREATHING SYSTEMS

BREATHING VS. NONREBREATHING SYSTEMS Also known as a circle system Exhaled gases are re-circulated back to the patient. After exhalation, they go through the unidirectional valve, to the CO2 canister and the reservoir bag, then back through the inhalation valve where they are combined with more fresh gas for the patient to inhale.

BREATHING VS. NON-REBREATHING SYSTEMS Choose a re-breathing system for your patient if the patient is >15lb (7kg) Because re-breathing systems recycle exhaled gases, the O2 flow rates are relatively low. When we recycle, we don’t have to use as much oxygen or anesthetic gas.

Re-breathing Systems Depending on the position of the pop-off valve, we can call a re-breathing system CLOSED OR SEMI-CLOSED CLOSED- the pop-of valve is totally closed. All gases exhaled by the patient remain in the circuit and are re-circulated after the CO2 is absorbed SEMI-CLOSED- the pop-off valve is open or semi-closed. Some gases exhaled by the patient remain in the circuit, some exit through the pop off and into the scavenger

CLOSED Total re-breathing Low oxygen flow rate! Pop off valve is closed SEMI-CLOSED aka partial re-breathing Higher oxygen flow rate than closed system Pop off valve is open letting excess gases be scavenged (in some cases, valve may not be open ALL the way)

RE-BREATHING VS. NON-REBREATHING SYSTEMS In a non-rebreathing system, oxygen flows from the tank to the flowmeter and vaporizer, however the unidirectional inhalation valve is bypassed. Fresh gas enters a hose after the vaporizer and is inhaled by the patient. Exhaled gases exit through a separate hose and into a reservoir bag. There is no entry into the CO2 canister. The gases pass through the pop off valve and into a scavenging system. Most anesthetic machines can be converted back and forth from re-breathing to non-rebreathing systems

BREATHING VS. NONREBREATHING SYSTEMS Choose a non-rebreathing system for your patient if it weighs less than 15lb (7kg). Little to no gas is recycled back to the patient, so O2 flow rate are very high! Since we are being wasteful and NOT recycling, we have to use more oxygen and anesthetic gas The pop-off valve should be all the way open or partially open with a non-rebreathing system.

NON-REBREATHING SYSTEM ADVANTAGES: Great for small patients (< 7 kg) as it offers very little resistance to breathing. Lighter weight than conventional tubing; creates less drag on tube DISADVANTAGES: More expensive as more gas is used. Patients are more susceptible to heat loss without the benefit of the tube within a tube.

NON-REBREATHING Commonly used Bain Co-axial system Tube within a tube Inner tube delivers fresh gas to the patient. Outer tubing conducts gas away from the patient and into a reservoir bag. Since most of the gas is scavenged and does not re-enter the patient, the bag is used to visualize respirations and facilitate manual ventilation. Incoming gases are warmed by exhaled gases

CO2 absorption Not necessary Must have Quickly Slowly Flow rates High Parameters Nonrebreathing Rebreathing CO2 absorption Not necessary Must have Anesthetic depth change Quickly Slowly Flow rates High Low Cost Waste gas Minimal Pop off valve Fully open Open, Closed or partially open Heat and moisture conservation Poor Good Animal size < 7 kg >7 kg, unless pediatric hoses are available

O2 FLOW RATES Depends on the period of anesthesia and the type of system being used Generally, flow rates during induction and recovery are higher because we are trying to achieve a rapid change in anesthetic depth. Chamber induction: 5 L/min Mask induction: animals <10kg = 1-3 L/min animals > 10kg = 3-5 L/min

O2 FLOW RATES MAINTENANCE FLOW RATES NONREBREATHING: REBREATHING 150-200ml/kg/min (ex: Bain Coaxial system) 400-600mL/kg/min (ex: Jackson-Rees) WE COMMONLY USE 250 mL/kg/min at VTI (and we will round up to at least 0.8 L/min) REBREATHING CLOSED: 5-10 mL/kg/min, SEMICLOSED: 20-40 mL/kg/min WE COMMONLY USE 40 mL/kg/min at VTI (and will round up)

LEAK TEST TO BE PERFORMED BEFORE EVERY ANESTHETIC PROCEDURE! Close pop-off valve and cover the patient end of the anesthetic tube Push O2 flush button or turn on flow meter until bag is distended and the pressure on the manometer reads 30cm H20. Turn O2 off and watch the manometer. If the reading drops rapidly, bag deflates rapidly, or a hissing sound is heard, leak is present. If there were no leaks, the pressure would remain constant for at least 30 seconds, despite the O2 being turned off.

LEAK TEST CONT’D Check the hoses, bag, attachments of machine to be sure everything is properly placed When test is over, reopen pop off valve and squeeze the reservoir bag.

RESERVOIR BAGS WEIGHT BAG SIZE 0-3 kgs ½ L 4-7 kgs 1 L 8-15 kgs 2 L