Better Safety, Better Effectiveness Well suited for digestion by acids Proposal New idea for pretreatment of sample analysis ECOPRE-SYSTEM.

Slides:



Advertisements
Similar presentations
Lab Safety, Variables and Graphing
Advertisements

Lab Equipment. (Lab Coat or Lab Apron ) Beaker Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter if.
Lab Equipment. Beaker Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated.
Lab Equipment. Beaker Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated.
Scientific Lab Equipment graduated cylinder (graduate) To measure volume of liquids accurately.
 The beaker is used to measure and pour “non-exact”, or approximate amounts of liquids. Liquids may also be heated in a beaker. The most common unit is.
TEKS 2(E) plan and implement (carry out) investigative procedures, including asking questions, formulating testable hypotheses, and selecting equipment.
427 PHC. Direct-Current Plasma  A direct-current plasma (DCP) is created by an electrical discharge between two electrodes. A plasma support gas is necessary,
Lab Equipment. Gloves Safety First Fume Hood Beakers Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter.
Lab Equipment Pre-AP Chemistry.
Determination of the Molar Volume of Hydrogen Gas.
Laboratory Techniques I: Dilution Go to browse and set to full screen.
Experimental Procedure Lab 402. A. Preparing the Sample.
LAB SAFETY! WHAT DO YOU DO? HOW SHOULD YOU DO IT? WHAT HAPPENS IF YOU DO IT WRONG?
SURVEY OF CHEMISTRY LABORATORY I
Organization of an Organic Chemistry Laboratory. Organic chemistry laboratories are mainly specified to conduct organic chemistry research studies, in.
A Few Safety Rules Think through each step before beginning an experiment Identify possible hazards and take appropriate measures to contain or minimize.
Lead Content in Toys Katrina Nowak Chemistry 4101 Fall 2008.
A Few Safety Rules  Think through each step before beginning an experiment  Identify possible hazards and take appropriate measures to contain or minimize.
A Few Safety Rules ä Think through each step before beginning an experiment ä Identify possible hazards and take appropriate measures to contain or minimize.
Lab Equipment.
Culinary Arts I Food Safety andSanitation. FOOD SAFETY Reducing the risk of making yourself and others sick through food production FOOD SAFETY Reducing.
Lab Equipment.
Lab Equipment.
Potentially Hazardous Foods Foods of animal origin that is raw or heat treated. Food of plant origin that has been heat treated (rice, beans, pasta, potatoes)
1 © Copyright DWT GROUP 1 DWT reserve the right to make modifications without prior notice.
Lab Experiment 2: Copper Cycle September 7, 2011.
Lab Equipment. Beaker Holding liquids may be graduated (sometimes in two directions) has a white spot for labeling various sizes including 50, 150, 250,
Lab Equipment. ThermometersThermometers A thermometer is a device that measures temperature.
Common Chemistry Lab Equipment. A. Well Plate  Used as a “small scale” reaction vessel, where you are only using drops of solutions.
Less Manganese lost over C Manganese in Sea Water Excessive Background signal from NaCL Large loss of analyte.
Experimental Procedure Lab 406. Overview A known mass of starting material is used to synthesize the potassium alum. The synthesis requires the careful.
Distillation Lab. How Distillation Works Distillation separates liquids based on their different boiling points. Liquids are boiled and then recondensed.
Lab Equipment. Beaker Holding liquids may be graduated (sometimes in two directions) has a white spot for labeling various sizes including 50, 150, 250,
Laboratory Equipment and its Usage
Environmental Express Webinar HotBlock Systems – Precision Heat with Various Uses 12/08/15.
Pre-Lab 10A: Pure Substance or Mixture
Lab Equipment Subtitle. Beakers and Graduated Cylinders Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter.
Make up Labs 4.1 and 4.3.
Lab Activity 4 A. Extraction & Determination of Crude Fat from Plant or Animal Tissues B. Determination of Dry Matter and Moisture Content In Plant Materials.
Distillation Lab.
Lab Equipment & Procedures. Goggles Protect eyes.
Quantitative determination of nickel in a compound Go to browse and set to full screen.
Lab Equipment. Safety Goggles Protect eyes from chemical exposure. Must ALWAYS be worn while working in the lab.
 In this lab experiment you are going to play the role of a chemical detective to decide which chemicals are present in common food substances.  Certain.
Determining The freezing Point Of Acetic Acid ! Chemistry 1105.
ODLAB The Graphite Block Acid Digestion System (ECO-PRE)
Lab Equipment.
By Maryum Atique M.Phill chemistry University of Agriculture.
Preparation of Chemical Compound in Laboratory Scale
Copper Labs 5 labs, several days, 100 pts..
1. Features of Preparation Equipment
Lab Equipment.
Kjeltec Instrument Title slide with Total Nutrition.
Lab Equipment.
Gooooood Morning!!! 1.) According to the dress code, what should you wear in the laboratory? 2.) In what cases might you be asked to leave the laboratory?
Sediment Sample Digestion Method
What is Desuperheater Water heater and its Applications?
Heavy metals concentration of Fecal Solids of Recirculating Aquaculture System for Renewal Feed Resource for Sea Cucumber Anisuzzaman Md, Feng Jin, Ga-Hyun.
Laboratory Glassware and Apparatus
Zhifeng Zhang Division of Marine Environmental Chemistry
Lab Equipment.
Lab Safety.
Pollution & Toxins Pollutant
بر اساس جدول تناوبی از یک جایی به بعد فلزات سنگین قرار دارند
Experiment 7.
Lesson 27: Electrons on the Move
Sediment Sample Digestion Method
Suggested Technology for Remediation of Contaminated Soil
pH: Hands on strategies to tackle misconceptions
Presentation transcript:

Better Safety, Better Effectiveness Well suited for digestion by acids Proposal New idea for pretreatment of sample analysis ECOPRE-SYSTEM

① No need to add acid during digestion ② Able to analyze sample weight enough (up to solid 5g) ③ Easy handling system from start to end ④ Emits low harmful gas ⑤ Homogenous digestion up to 45 samples ⑥ Provides safety environment ⑦ Able to other work during digestion (safety, save time) ECOPRE-SYSTEM

Acid Inert Heating Plates & Semi-opening vessel ・The world’s first Semi-Opening Vessel of air condensing ・No need to add hazardous acid during digestion ・Diminish damage of high cost Hood ・Fluoroplastic vessel (high durability) ・Acid inert heating plates coated with Teflon ・Available for analyzing trace samples ・Provide safe environment ・Analyze multiple samples at once Propose new Graphite Digestion System

Process 1. Put vessel on the electronic scale then measure of weight 2. Drop reagent into a digestion vessel3. Drop HNO3(5%) into a collection tube 4. Arrange the vessels on the graphite block then start heating 5. Digesting with brown gas6. End of digestion

220℃220℃ 160 ℃ 120 ℃ ① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ Best example of digestion process ⑩ ① ② ③ ④⑤ ⑥ ⑦ ⑧ ⑨ Applying as circulating program(heating∙condensing) above, digest samples safely End 170℃ 140℃

Beaker∙Block Heater Microwave High Pressure Digestion Digestion System depends on detection level ppm >> ppb >> ppt

The World’s First Circulating Digestion Method 300 ml 100 ml 60 ml Peak point of evaporation Reagent backflow Repeatedly circulate the process to digest completely Reagent evaporate Heating the vessel up to 245℃ Circulating digestion continually Able to Digest high oily, organic contents Especially, provide safety environment for working Secondary Reagent evaporate Start Heating Hood Damage, Decline use time (protected by patent)

* Put sample and reagent on digestion vessel then arrange the vessel on the graphite block simply * No need to add acid, No need to observe for all processes * Without waste time, work other operation at once You are able to arrange a day effectively with ECO-PRE !! Key Point for recommending ECO-PRE

Comparison Table of digestion time depends on equipment 1. ECO-PRE Digestion System (24samples) Start Digestion → Vessel cooling → Modify location → Vessel cooling → Modify location → Vessel cooling → Modify location → Vessel cooling →end preparing ↑30min↑10min↑30min↑10mln↑30min↑10mln↑20min digestion about 4~6hour+observing time + handling Start Digestion → Pick out vessel and cooling → Mass up Wash vessel → Pick out vessel and cooling, waste water → Preparing samples, digestion → Pick out vessel and cooling →end preparing 1H ↑30min↑40min +wash 1H ↑40min +digestion1H ↑30min 24 samples digestion about 2hour + washing, cooling, preparing next samples etc. = about 6hour totally Start Digestion →→→→→→→→→ Vessel cooling →end preparingNo additional conditionsAbout 4~6HNo additional conditions↑20min digestion about 4~6hour+cooling 20min Sample : rice, meat, processed food, crop, soil etc. 3. Microwave (24samples) ※available up to 12samples with Rotor 2. Hotplate with Beaker (24samples)

* ODLAB controller is separable to connect with hood outside and decline damage from heat, acid * The wiring jacketed with fluoroplastic tube to prevent damage from acid Separable Controller Fluoroplastics Tube Connected to Controller Separable Touch Screen Controller

* Easy handling with screen manual * Able to save your digestion method then import from saved List * Show present temperature/time, proceeding temperature/time on the Windows CE, 7 inch screen * Smart alarm to announce wrong applied temperature, error etc. Touch Screen Controller Apply a programImport from saved user program list

Major Sample Application SamplesWeightReagentCollection liquidUp to (℃) Digestion Time Rice 0.5g (dry) HNO3 14ml5% HNO3 6ml210℃4H Fish0.5gHNO3 15ml + H2O2 3ml5% HNO3 6ml210℃4H Cake, milk0.5gHNO3 14ml5% HNO3 6ml220℃4H Half Natural seasoning1gHNO3 14ml5% HNO3 6ml200℃5H Concentrated orange juice 5gHNO3 17ml + H2O2 3ml5% HNO3 6ml210℃7H Canned fruits0.5HNO3 10ml + H2O2 2ml5% HNO3 6ml210℃1H Half Plant Oil0.5gHNO3 15ml + H2O2 5ml5% HNO3 5ml220℃4H~ Spinach3gHNO3 15ml5% HNO3 6ml200℃4H~ Soil(ISO11466)3gHNO3 7ml + HCl 21ml5% HNO3 6ml130℃4H~ PE (chip) 0.2gHNO312ml + H2SO4 2ml5% HNO3 6ml220℃10H PS (chip) 0.2gHNO3 20ml + H2SO4 2ml5% HNO3 6ml220℃10H~

* In August, 2008 ODLAB began and developed ECO-PRE digestion system and opened to sales * About 500 customers in the world use ECO-PRE * Provides a wide variety of custom services in the environment, grocery, agriculture, technical, semiconductor industry About ODLAB