Date of download: 6/3/2016 Copyright © The American College of Cardiology. All rights reserved. From: A Novel Contrast Removal System From the Coronary Sinus Using an Adsorbing Column During Coronary Angiography in a Porcine Model J Am Coll Cardiol. 2006;47(9): doi: /j.jacc The 8-F blood-suction catheter. Figure Legend:
Date of download: 6/3/2016 Copyright © The American College of Cardiology. All rights reserved. From: A Novel Contrast Removal System From the Coronary Sinus Using an Adsorbing Column During Coronary Angiography in a Porcine Model J Am Coll Cardiol. 2006;47(9): doi: /j.jacc Effects of column use on iodine concentration. Iodine concentrations were measured in the flow at the inlet and the outlet of the column during circulation. Values are presented as mean ± SEM (n = 5). *p < 0.001; †p < 0.05; inlet vs. outlet, respectively. Figure Legend:
Date of download: 6/3/2016 Copyright © The American College of Cardiology. All rights reserved. From: A Novel Contrast Removal System From the Coronary Sinus Using an Adsorbing Column During Coronary Angiography in a Porcine Model J Am Coll Cardiol. 2006;47(9): doi: /j.jacc Removal of contrast medium using the column. Values are presented as mean ± SEM (n = 5). The solid lines show the individual values. Figure Legend:
Date of download: 6/3/2016 Copyright © The American College of Cardiology. All rights reserved. From: A Novel Contrast Removal System From the Coronary Sinus Using an Adsorbing Column During Coronary Angiography in a Porcine Model J Am Coll Cardiol. 2006;47(9): doi: /j.jacc Changes of iodine concentrations in peripheral blood resulting from the use of the column. Values are presented as mean ± SEM (n = 5 or 3). *p < ; †p < Figure Legend:
Date of download: 6/3/2016 Copyright © The American College of Cardiology. All rights reserved. From: A Novel Contrast Removal System From the Coronary Sinus Using an Adsorbing Column During Coronary Angiography in a Porcine Model J Am Coll Cardiol. 2006;47(9): doi: /j.jacc Area under the curve in femoral venous blood treated with or without the column. Values are presented as mean ± SEM (n = 5 or 3); p = AUC0-90 = area under the curve of iodine concentrations in the femoral vein from 0 to 90 min of the extracorporeal circulation time. Figure Legend: