Neuroimaging with MRI: combining physics and physiology to understand brain function Rhodri Cusack.

Slides:



Advertisements
Similar presentations
fMRI Methods Lecture6 – Signal & Noise
Advertisements

Richard Wise FMRI Director +44(0)
Basis of the BOLD signal
Fund BioImag : MRI contrast mechanisms 1.What is the mechanism of T 2 * weighted MRI ? BOLD fMRI 2.How are spin echoes generated ? 3.What are.
Statistical Signal Processing for fMRI
Introduction to Functional and Anatomical Brain MRI Research Dr. Henk Cremers Dr. Sarah Keedy 1.
Basics of fMRI Preprocessing Douglas N. Greve
Research course on functional magnetic resonance imaging (non-invasive brain imaging) Juha Salmitaival.
Introduction to Functional and Anatomical Brain MRI Research Dr. Henk Cremers Dr. Sarah Keedy 1.
Opportunity to Participate EEG studies of vision/hearing/decision making – takes about 2 hours Sign up at – Keep checking.
Principles of MRI. Some terms: –Nuclear Magnetic Resonance (NMR) quantum property of protons energy absorbed when precession frequency matches radio frequency.
HST 583 fMRI DATA ANALYSIS AND ACQUISITION Neural Signal Processing for Functional Neuroimaging Emery N. Brown Neuroscience Statistics Research Laboratory.
Functional Brain Signal Processing: EEG & fMRI Lesson 12 Kaushik Majumdar Indian Statistical Institute Bangalore Center M.Tech.
Magnetic Resonance Imagining (MRI) Magnetic Fields
Realigning and Unwarping MfD
Efficiency in Experimental Design Catherine Jones MfD2004.
EEG Experiment for Extra Credit Sign up on the sheet.
Principles of NMR Protons are like little magnets
fMRI introduction Michael Firbank
Opportunity to Participate
Structural and Functional Imaging Functional images tend to be lower resolution and fail to convey spatial information Pixels.
07/01/15 MfD 2014 Xin You Tai & Misun Kim
Predictive Modeling of Spatial Properties of fMRI Response Predictive Modeling of Spatial Properties of fMRI Response Melissa K. Carroll Princeton University.
The General Linear Model (GLM)
Principles of MRI Some terms: – Nuclear Magnetic Resonance (NMR) quantum property of protons energy absorbed when precession frequency.
1st level analysis: basis functions and correlated regressors
Measuring Blood Oxygenation in the Brain. Functional Imaging Functional Imaging must provide a spatial depiction of some process that is at least indirectly.
Signal and Noise in fMRI fMRI Graduate Course October 15, 2003.
Magnetic Resonance Imagining (MRI) Magnetic Fields Protons in atomic nuclei spin on axes –Axes point in random directions across atoms In externally applied.
HELSINKI UNIVERSITY OF TECHNOLOGY LABORATORY OF COMPUTER AND INFORMATION SCIENCE NEURAL NETWORKS RESEACH CENTRE Variability of Independent Components.
Co-registration and Spatial Normalisation
TSTAT_THRESHOLD (~1 secs execution) Calculates P=0.05 (corrected) threshold t for the T statistic using the minimum given by a Bonferroni correction and.
Basics of Functional Magnetic Resonance Imaging. How MRI Works Put a person inside a big magnetic field Transmit radio waves into the person –These "energize"
Analysis of fMRI data with linear models Typical fMRI processing steps Image reconstruction Slice time correction Motion correction Temporal filtering.
Signal and noise. Tiny signals in lots of noise RestPressing hands Absolute difference % signal difference.
FINSIG'05 25/8/2005 1Eini Niskanen, Dept. of Applied Physics, University of Kuopio Principal Component Regression Approach for Functional Connectivity.
FMRI Methods Lecture7 – Review: analyses & statistics.
STRATEGIES OF COGNITIVE NEUROSCIENCE The Coin of the Realm: correlations between psychological and neurophysiological events/structures Establishing two-way.
Multimodal Neuroimaging Training Program
Functional Brain Signal Processing: EEG & fMRI Lesson 14
BMI2 SS08 – Class 7 “functional MRI” Slide 1 Biomedical Imaging 2 Class 7 – Functional Magnetic Resonance Imaging (fMRI) Diffusion-Weighted Imaging (DWI)
Spatial Smoothing and Multiple Comparisons Correction for Dummies Alexa Morcom, Matthew Brett Acknowledgements.
The General Linear Model (for dummies…) Carmen Tur and Ashwani Jha 2009.
SPM Pre-Processing Oli Gearing + Jack Kelly Methods for Dummies
Methods for Dummies Second level Analysis (for fMRI) Chris Hardy, Alex Fellows Expert: Guillaume Flandin.
Statistical Analysis An Introduction to MRI Physics and Analysis Michael Jay Schillaci, PhD Monday, April 7 th, 2007.
What are we measuring in fMRI?
Our entry in the Functional Imaging Analysis contest Jonathan Taylor Stanford Keith Worsley McGill.
The General Linear Model Guillaume Flandin Wellcome Trust Centre for Neuroimaging University College London SPM fMRI Course London, May 2012.
Analysis of FMRI Data: Principles and Practice Robert W Cox, PhD Scientific and Statistical Computing Core National Institute of Mental Health Bethesda,
Aa Scripting SPM analyses using aa Rhodri Cusack.
The General Linear Model Christophe Phillips SPM Short Course London, May 2013.
The General Linear Model Guillaume Flandin Wellcome Trust Centre for Neuroimaging University College London SPM fMRI Course London, October 2012.
Biophysics of BOLD and common image artefacts Rhodri Cusack Overview Biophysics of BOLD signal -Neural > Hemodynamic > MRI Complications at each level.
BOLD functional MRI Magnetic properties of oxyhemoglobin and deoxyhemoglobin L. Pauling and C. Coryell, PNAS USA 22: (1936) BOLD effects in vivo.
functional magnetic resonance imaging (fMRI)
FMRI data acquisition.
Group Analyses Guillaume Flandin SPM Course London, October 2016
The general linear model and Statistical Parametric Mapping
The General Linear Model
MRI Physics in a Nutshell Christian Schwarzbauer
Signal fluctuations in 2D and 3D fMRI at 7 Tesla
The General Linear Model
Signal and Noise in fMRI
The General Linear Model
The General Linear Model (GLM)
The General Linear Model
The General Linear Model
The General Linear Model
Basics of fMRI and fMRI experiment design
Presentation transcript:

Neuroimaging with MRI: combining physics and physiology to understand brain function Rhodri Cusack

Nuclear magnetic resonance Nuclei are small magnets Lower energy when aligned with field –Radio frequency (RF) energy can knock them out of alignment –As they revert, emit RF Simple relationship between field strength (B 0 ) and RF frequency –Quantum mechanics -> only exact frequency will do magnetic field radio frequency (RF) energy

Magnetic resonance imaging Clever bit: working out which bit of signal came from where Different tricks for each of three dimensions All based on applying “gradients” in magnetic field gradient in magnetic field radio frequency (RF) energy

MRI: “pulse sequences” RFRecord Gradient in z Gradient in x Gradient in y Spin echo; Gradient echo

Potential dangers & annoyances Magnetic field RF Gradients

Two different MRI acquisitions Structural image (“Anatomical”, “T1”, “SPGR”) Resolution 1x1x1mm; 256x256x256 voxels T1 weighted for contrast between grey and white matter. Spin-echo. 12 minutes Functional (“T2*”, “EPI”,”BOLD”) Typically 4x4x5mm; 64x64x21 voxels T2* weighted gradient-echo for contrast between active and resting states 1.1 seconds

Detecting function Oxygen contained in oxy-haemoglobin in arteries used by spiking and other metabolic processes Veins contain deoxy-haemoglobin –Has different magnetic properties to oxy-haemoglobin, and to tissue –Introduces inhomgeneities in magnetic field which cause reduction in MRI signal –Reduction especially large for T2* weighted gradient echo sequences With Shaihan Malik

Detecting function When a brain region is active: –Blood flow increases –Veins increase in size –Extra blood supply is greater than use, so amount of deoxy- hemoglobin actually reduces Net effect is a reduction in field inhomogeneity, and an increase in MR signal “BOLD” effect – not simple

FMRI: experimental design Acquire one image every 1.1s Typical experiment –30 mins long – around 1600 images –blocks of around 30 secs AA ABB time hemodynamic response “block design”

O’Craven & Kanwisher (2000)

Hemodynamic response function

Event-related design Events Predicted HDR time (s) Advantages Psychological disadvantages of blocking trials. Essential for some designs (e.g., oddball) Post hoc/ subjective classification Other models Add temporal derivative; dispersion Fourier basis sets FIR

Henson et al (1999)

Factors affecting efficiency of design Temporal autocorrelation –Noise in MRI is autocorrelated: datapoints close in time have more similar noise values Haemodynamic response –This smoothes higher frequency components in design Adaptation Low frequency drift

Efficiency of design Most efficient design depends on contrast Block design more efficient than event related –Two conditions:12 seconds on/ 12 seconds off –Mechelli, Price, Henson, Friston (2003)

FMRI analysis: “preprocessing” stages Slice timing –different slices in the head are acquired at different times –can correct for this by interpolating across time Motion correction –subjects usually move a little over the course of the session –this introduces a strong artefact unless corrected for Undistortion

Artefacts in EPI: Fields should be flat Different materials act to strengthen or weaken magnetic fields Ideally, field should be homogeneous –Easy to arrange when it is empty, but ruined as soon as a head is put in

Field strength relative to 3 Tesla (parts per million)

Field inhomogeneity artefacts: dropout

Field inhomogeneity artefacts: distortion

FMRI analysis – further preprocessing Normalisation –heads are different shapes and sizes –we wish to compare similar brain regions across subjects –non-linear warping to common space Smoothing –makes data normal through time

FMRI analysis: statistical model Multiple regression model to partition components –predicted HDR for each e.g., visual stimulus; motor response; novelty detection –sometimes also “movement parameters” t-test or F-test –Within a subject (“fixed effects, FFX”) –Across subjects (“random effects, RFX”)

Multiple comparisons problem Separate statistical test is being performed for each voxel –“mass univariate” Lots and lots of these –By chance, very likely that some of them will come out significant Bonferroni correction excessively conservative Gaussian Field Theory –Independently developed by some Russian submarine scientists, and Worsley & Friston –Activation tends to be clustered together can allow lower threshold if lots of voxels in one region have a shift –“corrected” p-values

O’Craven & Kanwisher (2000)

Common software SPM from FIL, London –Most common tool worldwide –Default at CBU; most people script with “aa” –Current version SPM 5 FSL (“fossil”) from FMRIB, Oxford –Latest version 4 –Fast, useful extra tools (e.g., MELODIC ICA analysis) BrainVoyager – commercial –Often used for flat mapping AFNI – Robert Cox –More widespread in US

Further imaging techniques Adaptation –Reduction in response for repeated stimuli –Can test whether two tasks (A, B) both recruit the same neuronal population within a voxel AA vs. AB or BA MVPA: correlation in spatial patterns DTI

Haxby et al (2001)

Being critical Imaging experiments are expensive to run –Around £ per study Brain imaging is hard –Hard to design the right task Our knowledge of the brain is often crude –Scanners are hard to set up and frequently fail in complex ways –Analysis is complicated, and takes a long time Scientists are reluctant to throw away data –Temptation to reanalyze until something works –Re-interpret original hypotheses –Not as alert as should be to potential artefacts Be sceptical –Watch p-values; group studies, random effects most reliable –Look for confirmation across studies

Running an imaging study at the CBU Consult the guide on the wiki Academic review –Present to your group –Present at the Imaging Interest Group meeting –Apply to Imaging Management Committee for slots Leave time for practicalities –LREC –Insurance –Setting up your experiment –Running a behavioural pilot