“Ventilation of Healthcare Facilities” Impact of the New ANSI/ASHRAE/ASHE Standard 170 Standard 170 Stephen W. Nicholas, CPMM, CAFS ASHRAE Boston Chapter.

Slides:



Advertisements
Similar presentations
Sustainable School Design Creating Healthy, High Performance School Facilities Presented by Stephen M. Koontz, Energy Services Leader, Tampa Bay Trane.
Advertisements

Purpose of 2005 Guidelines Update and replace 1994 Mycobacterium tuberculosis infection control (IC) guidelines Further reduce threat to health-care workers.
HVAC Systems and Their Role in Infection Control and Prevention
BSA Health System, May 2009 Next Slide Previous Slide BSA HEALTH SYSTEM Infection Control during Construction, Renovation, Repairs, and Maintenance All.
TESTING AND BALANCING IN HEALTHCARE FACILITIES. What is Test & Balance The art of establishing air and water flows to meet design criteria. Total System.
Medication Management
Introduction Efficient intra-hospital transport of severe closed head injury and stroke patients requires maintenance of consistent ventilation and oxygenation.
The Role of Controls for Indoor Air Quality Kent W. Peterson, PE, Fellow ASHRAE P2S Engineering, Inc. Mid Columbia ASHRAE Chapter.
Innovative Air Distribution for Healthcare Facilities.
The Care and Isolation Unit (CIU) at St Patrick Hospital In 2005 the NIH issued a Request for Proposals for the construction and staffing of a patient.
Indoor Air Quality (IAQ) March 2009 UCOP Safety Meeting.
Break Out Session 3: Group A: Ventilation and Air Quality Chris Cosgrove, Cosgrove FDS, Inc.
CODE REVIEW: DOH Article 28 Compliance Establishing a Feasibility process that is focused on compliance with New York State Department of Health rules.
International Code Council (ICC) Non-profit member focused association Approximately 50,000 members Develops the I-Codes (15 codes) Established in 1994.
The House as a System 1. Air Temperature and Water Vapor.
AIA Iowa Complying with the 2014 FGI Acoustical Guidelines #A203 Jon W. Mooney PE September 26, 2014.
Unit 6.2. Mechanical and mixed mode ventilation TB Infection Control Training for Managers at National and Subnational Level.
Guidelines for Prevention of TB Centers for Disease Control & Prevention.
Precertification. 2 Precertification What is precertification? The purpose of precertification is to ensure that you and anyone else covered under your.
TB Infection Control: Engineering (Environmental) Controls Kevin P. Fennelly, MD, MPH Division of Pulmonary & Critical Care Medicine Center for Emerging.
1 Ventilation, Temps and Humidity Requirements PO Box 3187 Charleston, WV Inquisit February 6, 2014.
PART IX: EMERGENCY EXPOSURE SITUATIONS Module IX.1: Generic requirements for emergency exposure situations Lesson IX.1-2: General Requirements Lecture.
Portable High Efficiency Air Filtration (PHEAF) Device Field Testing and Validation Standard ANSI/IESO Standard
Copyright National Air Filtration Association 2006 Rev. 2 Hospital & Healthcare Facilities.
January Goals: Streamline permitting process for certain solid waste facilities and activities Expand use of 3 rd party inspectors to allow MassDEP.
Humidity in Anesthetizing Locations Where Mechanical Systems and Compliance Collide Daniel Swanson | Project Director Healthcare | McKinstry Currently.
Indoor Firing Ranges Training Education Recommended Practices.
Unit 6.4. Filtration TB Infection Control Training for Managers at National and Subnational Level.
REGULATIONS. LIMITATIONS Availability of funds Lack of scientific data Property rights of individuals.
NORTH AMERICAN SAFETY CHECKLIST – SB 158. Rhonda Anderson, RHIA President Anderson Health Information Systems, Inc. Presented By:
The Effects of Construction Activity on Indoor Air Quality for Hospitals Presented by: Tom N. Petersen, P.E. Environmental and Engineering Solutions, Inc.
Shaping Tomorrow’s Built Environments Today. Who We Are 52,000 volunteer members in over 130 countries – More than 170 chapters – More than 250 student.
Getting Started or so you are the new Infection Preventionist – what now? Karen Hoover Russ Olmsted Ruth Anne Rye.
Ontario Ministry of Labour Health Care Sector Proactive Inspection Program Acute and Long Term Care Facilities Leon Genesove MD FRCPC March
The Physical Environment Tracers How Should I Prepare for the Physical Environment Tracers? Healthcare Engineering Consultants  Will limit.
Ohio MOLST Initiative Jeff Kaufhold, MD FACP Chair, Grandview Bioethics Advisory Committee Aug 2012.
SARS: Protecting Workers. OSHA Guidance for Employers on Severe Acute Respiratory Syndrome (SARS) Potentially deadly respiratory disease Potentially deadly.
SARS: Protecting Workers. OSHA Guidance for Employers on Severe Acute Respiratory Syndrome (SARS) Potentially deadly respiratory disease Potentially deadly.
Improving Tuberculosis Infection Control
AIA Guidelines for Design and Construction of Hospital and Healthcare Facilities Presented By: Michael A. Rogers, PE
EXPENSE REDUCTION PROPOSAL FISCAL YEAR END MARCH 31, 2011 JAMIE LOFTON BELLEVUE UNIVERSITY Metropolis Health System.
Getting Started or so you are the new Infection Preventionist – what now? Karen Hoover Russ Olmsted Ruth Anne Rye.
Standard and Transmission-Based Precautions
Chapter 5 Infection Control.
Hamot Women’s Hospital Erie, PA Michael Galleher Mechanical Option l AE-Senior Thesis l April 12, 2011 l Advisor Dr. Jelena Srebric.
Marketing Member Benefits, Publications, Discounts.
Prepared for: NSHE Winter Telehealth Conference February ASHRAE STANDARD LEGIONELLOSIS: RISK MANAGEMENT FOR BUILDING WATER SYSTEMS &
© 2015 HDR, Inc., all rights reserved.. OPERATING ROOM DESIGN & OPERATION Andy Yosten September 15, 2015.
Laboratories and Hospitals Which Way is the Air Blowing? Presented by: Douglas Wrenn – CCM, QCxP, CXCP, LEED ap.
HEALTHCARE SYSTEM Infection Control during Construction, Renovation, Repairs, and Maintenance All workers engaged in the construction, renovation, repair,
Infection Control Risk Assessment Guidelines and Standards Richard Vogel - Infection Control Specialist.
VENTILATION AND AIR CONDITIONING Under the Subject Industrial Safety and Environment || ||
Mintie Technologies, Inc. ECU Product Introduction and Demo/Training Virginia Presentation.
PRESENTED BY ENG. PRISCILLA NAKIBONEKA SANITARY ENGINEER, MINISTRY OF HEALTH, UGANDA.
Prevention and Control of Influenza A (H1N1) in the Workplace Engr. Nelia G. Granadillos Chief, Environment Control Division Occupational Safety and Health.
HEALTHCARE VENTILATION Opportunities for Change
CODE REVIEW: DOH Article 28 Compliance
Infection Control Risk Assessment
Changes and Challenges of 52.2 and ISO Update
ASHRAE’s 62.2 Residential Ventilation Standard Proposed Changes
Filtration & Hardware Performance for Healthcare Facilities
What Has the New MERV Table Done to My Products?
Critical Environment Control Solutions
ANSI/ASHRAE 52.2 A destructive test to measure minimum efficiency reporting value (MERV) Efficiency test aerosol is Potassium Chloride (KCl) particles,
MarketsandMarkets Presents Cleanroom Technology Market worth $3,761.9 Million by
GES SYSTEM THE IMPORTANCE OF GES SYSTEM IN BUILDING
Pre Construction Risk Analysis
Biocontainment Patient Care Unit--Consensus Standards
NERD CORNER Get Your CIC On.
Chapter 3B: INDOOR AIR QUALITY
Presentation transcript:

“Ventilation of Healthcare Facilities” Impact of the New ANSI/ASHRAE/ASHE Standard 170 Standard 170 Stephen W. Nicholas, CPMM, CAFS ASHRAE Boston Chapter Vice President May 5, 2011

S-170 Project Title Title –“Ventilation of Healthcare Facilities”

S-180 Project Purpose Purpose The purpose of this standard is to define ventilation system design requirements that provide environmental control for comfort, asepsis and odor in health care facilities. The purpose of this standard is to define ventilation system design requirements that provide environmental control for comfort, asepsis and odor in health care facilities.

S-170 Project Scope Scope The requirements in this standard apply to patient care areas and related support areas within health care facilities, including hospitals, nursing facilities, and out patient facilities. The requirements in this standard apply to patient care areas and related support areas within health care facilities, including hospitals, nursing facilities, and out patient facilities.

S-170 Project Scope Scope This standard applies to new buildings, additions to existing buildings, and those alterations to existing buildings that are identified within this standard. This standard applies to new buildings, additions to existing buildings, and those alterations to existing buildings that are identified within this standard.

S-170 Project Scope Scope This standard considers chemical, physical, and biological contaminants that can affect the delivery of medical care to patients, the convalescence of patients, and the safety of patients, health care workers and visitors. This standard considers chemical, physical, and biological contaminants that can affect the delivery of medical care to patients, the convalescence of patients, and the safety of patients, health care workers and visitors.

S-170 Project Standard falls under TC 9.6 Standard falls under TC 9.6 Standard will be placed under continuous maintenance Standard will be placed under continuous maintenance Addenda will be added to Standard and published on periodic scheduling Addenda will be added to Standard and published on periodic scheduling Appendix is not part of the mandatory requirements of the Standard Appendix is not part of the mandatory requirements of the Standard

S-170 Project Table 7.1 “Design Parameters” Table 7.1 “Design Parameters” Addendum (a) Clarifies four (4) items related to Table No. 1 Addendum (a) Clarifies four (4) items related to Table No. 1 Most notably Relative Humidity (RH) changed from 30-60% to 20-60% Most notably Relative Humidity (RH) changed from 30-60% to 20-60%

S-170 Project Table 7.1 “Design Parameters” Table 7.1 “Design Parameters” –Addendum (b) covers ten (10) issues –HEPA Filters on 0.3 micrometers are now specified eliminating the MERV-17 designation

S-170 Project “Design Parameters” “Design Parameters” Pressure Relationships Pressure Relationships For Critical Care For Critical Care For Wound Intensive Care For Wound Intensive Care –No Requirement (N/R)

S-170 Project The Rationale is Twofold The Rationale is Twofold 1. Prior FGI Guidelines had N/R for these types of rooms 2. Literature review determined no increased benefit from either a positive or negative pressurized rooms * Since HAI primarily are H2o/Moisture related microbes not airborne

S-170 Project “Design Parameters” “Design Parameters” OR Suites are required to have individual Temperature Controls OR Suites are required to have individual Temperature Controls Morgue & Autopsy Rooms require ” w.g or Pascals Morgue & Autopsy Rooms require ” w.g or Pascals Endoscopy Room – Classified as a Gastrointestinal Procedure Room now require a Total of 6 Air Changes per Hour (ACH) Endoscopy Room – Classified as a Gastrointestinal Procedure Room now require a Total of 6 Air Changes per Hour (ACH)

S-170 Project “Design Parameters” “Design Parameters” MERV – 7 filters are now required for re-circulating room HVAC units MERV – 7 filters are now required for re-circulating room HVAC units Subsequently revised in Addendum (h) Subsequently revised in Addendum (h)

S-170 Project Design Parameters” Design Parameters” Filter Blank-Off Panels & Seals are now required to minimize unfiltered air from by-passing filters Filter Blank-Off Panels & Seals are now required to minimize unfiltered air from by-passing filters

S- 170 Project The Title of the humidity column in Table 7-1, “Design Parameters” has been changed to “Design Relative Humidity” The Title of the humidity column in Table 7-1, “Design Parameters” has been changed to “Design Relative Humidity” It was discovered that certain regulatory agencies were interpreting the humidity ranges in this column as absolute; meaning no excursions above or below these ranges was acceptable It was discovered that certain regulatory agencies were interpreting the humidity ranges in this column as absolute; meaning no excursions above or below these ranges was acceptable

S-170 Project “Design Parameters” “Design Parameters” Note: Note: However the actual RH in a space may be outside these ranges when outside conditions exceed design conditions However the actual RH in a space may be outside these ranges when outside conditions exceed design conditions

S-170 Project “Design Parameters” “Design Parameters” Addendum (d) was published in July 2010 Addendum (d) was published in July 2010 Revised RH range for (8) short stay rooms Revised RH range for (8) short stay rooms to 20-60% … these rooms are listed in Table No. 1 to 20-60% … these rooms are listed in Table No. 1

S-170 Project-Surgery Critical Care Class B & C OR Rooms (m) (n) (o) pos. Class B & C OR Rooms (m) (n) (o) pos. Surgical OR-Cystoscopic (m) (n) (o) pos. Surgical OR-Cystoscopic (m) (n) (o) pos. Delivery (caesarean) (p) pos. Delivery (caesarean) (p) pos. Treatment Room (p) N/R Treatment Room (p) N/R Class A OR Procedure Room (o) (d) pos. Class A OR Procedure Room (o) (d) pos. Trauma Room Crisis or Shock (c) pos. Trauma Room Crisis or Shock (c) pos. Gastrointestinal-Endoscopy Procedure pos. Gastrointestinal-Endoscopy Procedure pos. Laser Eye Room pos. Laser Eye Room pos.

S-170 Project Addendum (e) published March 2011 Addendum (e) published March 2011 –Clarifies ventilation provisions for Airborne Infection Isolation (AII) rooms “Exhaust Discharges” –All exhaust ductwork from rooms such as AII, bronchocopy, emergency, department waiting rooms, etc. must be maintained at a negative pressure as it passes from these rooms to the exhaust fan. –If the exhaust fan is located in a mechanical room vs. the roof, the interior ductwork on the discharge of the exhaust needs to be sealed to SMACNA Seal Class A

S-170 Project Addendum (f) Addendum (f) Published March 2011 clarifies: Published March 2011 clarifies: “Combination Airborne Isolation/Protective Environment Room” “Combination Airborne Isolation/Protective Environment Room” Added to the Guidelines to address cases of an immunocompromised patient who also has an airborne infectious disease Added to the Guidelines to address cases of an immunocompromised patient who also has an airborne infectious disease

S-170 Project Addendum (f) To reduce energy use in Hospitals To reduce energy use in Hospitals - The minimum total ACH for an AII room may be reduced to (6) when the room is not being used for an infectious patient - The minimum total ACH for an AII room may be reduced to (6) when the room is not being used for an infectious patient –However the pressure relationship must remain negative –The addendum reaffirms that switching a room from negative to positive or positive to negative is strictly prohibited

S-170 Project Addendum (g) published March 2011 Addendum (g) published March 2011 Allows Type D diffusers for single patient rooms Allows Type D diffusers for single patient rooms Addendum (g) is based upon recent research* Addendum (g) is based upon recent research* * Healthcare Ventilation Research Collaborative 2009 Displacement Ventilation Research – Phase II Summary Report

ASGRAE/ASHE Standard 170 Summary Standard 170 remains under continuous maintenance. Standard 170 remains under continuous maintenance. The addenda are a result of committee member initiatives, proposed changes, and requests for interpretations The addenda are a result of committee member initiatives, proposed changes, and requests for interpretations This allows for the FGI Guidelines to be updated between the four-year revision cycle This allows for the FGI Guidelines to be updated between the four-year revision cycle

ASHRAE/ASHE Standard 170 Any ?

For Further Information Stephen W. Nicholas, CAFS, NCT II Stephen W. Nicholas, CAFS, NCT II 200 Sutton Street Suite Sutton Street Suite 230 North Andover, MA North Andover, MA