Validation of the AOAC 2007.01 method for pesticides residues analysis in oranges and mandarins in LATU Marina Torres (1) 1, Lucía Alcarraz 1 (2) 1 Laboratorio.

Slides:



Advertisements
Similar presentations
Dr. Birgit Schmauser, BfArM, Bonn
Advertisements

Validation of screening methods (2002/657/EC)
Analytical Method Development and Validation
Instrumental Analysis
LC-ESI-MS/MS analysis of nine basic pharmaceuticals in influent, effluent and surface water Jet C. Van De Steene and Willy E. Lambert Laboratory of Toxicology,
Mentoring Session Technical Assistance Committee Method Modifications.
CHEMISTRY ANALYTICAL CHEMISTRY Fall
Dynamics of difenoconazole and propiconazole residues on pomegranate over a period of two years under field conditions Dr Soudamini Mohapatra Principal.
DETERMINATION OF PHYTOESTROGENS IN BEER BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY WITH DIODE ARRAY DETECTION J. Bernal 1. C. Martínez García-Mauriño 1,
Selectivity, Sensitivity, Signal to Noise, Detection Limit
PHARM 462 PART / /31 Good Manufacturing Practices (GMP) VALIDATION of ANALYTICAL TEST METHODS.
World Health Organization
Nitrosamine Detection in Meat By Beryl Ombaso, Chemistry 4101, Fall
1 Bisphenol-A Detection in Human Urine Megan Babcock Fall 2008.
11 Determination of the Levels of Fungicides on Citrus Fruits By Miseung Borgers Chem 4101, Fall 2008.
Validation of Analytical Methods
ASEAN GUIDELINES FOR VALIDATION OF ANALYTICAL PROCEDURES
QUALITY CONTROL OF PHYSICO-Chemical METHODS Introduction :Validation توثيق المصدوقية.
Validation of Analytical Method
The following minimum specified ranges should be considered: Drug substance or a finished (drug) product 80 to 120 % of the test concentration Content.
Analytical considerations
Quality WHAT IS QUALITY
How to Select a Test Method Marlene Moore Advanced Systems, Inc. June 15, 2010.
Bias and Errors. Some Terms Used to Describe Analytical Methods Accuracy Precision LOD RDL LOQ Selectivity Sensitivity Linearity Ruggedness.
Utilization of Accuracy Profiles as a Tool for the Validation of Analytical Methods A. Ceccato, P. Jacobs, A. Flament, M. Gibella and W. Dewé Lilly Development.
DEVELOPMENT OF A RP-HPLC METHOD FOR THE DETERMINATION OF METFORMIN IN HUMAN PLASMA.
Chem. 231 – 2/18 Lecture. Announcements Set 2 Homework – Due Wednesday Quiz 2 – Next Monday Set 1 Labs –should be switching instruments today (or after.
Quality Assurance How do you know your results are correct? How confident are you?
5. Quality Assurance and Calibration Quality assurance is We do to get the right answer for our purpose. Have Sufficient accuracy and precision to support.
1 Exercise 7: Accuracy and precision. 2 Origin of the error : Accuracy and precision Systematic (not random) –bias –impossible to be corrected  accuracy.
HPLC – High Performance Liquid Chromatography
1 International Federation for Consulting GmbH IFC Method Validation and QC for Pesticide Residue Analysis SANCO/2007/3131 by Dr. Michael Scheutwinkel.
Instrumental Methods: Intro
Introduction The importance of method validation
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Validation data and their meaning Ivo Leito Materials:
Midwest AOAC, St. Paul, MN, June 10, 2003
Industrial Technology Institute Test Method Validation & Verification H.P.P.S.Somasiri Principal Research Scientist / SDD-QAD /QM Industrial Technology.
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
Lecture 10 ANALYTICAL METHOD DEVELOPMENT AND VALIDATION IN HPLC AND GC. Lecture 10 – Chromatography, Dr. Rasha Hanafi 1© Dr. Rasha Hanafi, GUC.
Determination of metformin in urine (by Liquid Chromatography LC)
SEMINAR ON PRESENTED BY BRAHMABHATT BANSARI K. M. PHARM PART DEPARTMENT OF PHARMACEUTICS AND PHARMACEUTICAL TECHNOLGY L. M. COLLEGE OF PHARMACY.
Chapter 5 Quality Assurance and
EQUIPMENT and METHOD VALIDATION
Evolution GC-MS/MS: Pesticide analysis in canola oil Evolution GC-MS/MS: Pesticide analysis in canola oil Vivian Watts 1, Ingo Christ 1, Mark Misunis 2.
means to “TO CHECK OR PROVE THE VALIDITY OF” According to FDA – “ The goal of validation is to establish a documented evidence which provides a high degree.
이 장 우. 1. Introduction  HPLC-MS/MS methodology achieved its preferred status -Highly selective and effectively eliminated interference -Without.
Plasma Free Metanephrines Analysis using LC-MS/MS with Porous Graphitic Carbon Column Xiang He (Kevin) and Marta Kozak Thermo Fisher Scientific.
Introduction Sulfonylureas are an important group of systemic herbicides mainly used for the control of annual and perennial weeds in cereals or root crops.
Multi-Analyte LC-MS/MS Methods – Best Practice.
Quality is a Lousy Idea-
James Byrd, Marta Kozak 28 Apr 2011
ISTITUTO ZOOPROFILATTICO SPERIMENTALE
Introduction Results Aim of the study Methods Conclusion References
QuEChERS LRC Cartridge
World Health Organization
LC-MS/MS Analysis of Tetracycline antibiotics in Honey using Advance UHPLC-EVOQ™ SIMA LAB PVT LTD.
A sensitive and repeatable method for characterization of sulfonamides and trimethoprim in honey using QuEChERS extracts with Liquid-Chromatography-Tandem.
Dr. Birgit Schmauser, BfArM, Bonn
Instrumental Methods: Intro
Determination of carbamate residues in high-fat cheeses by ultra-high performance liquid chromatography–tandem mass spectrometry using zirconia-based QuEChERS.
Quality is a Lousy Idea-
Analytical Method Validation
Chapter 5 Quality Assurance and Calibration Methods
Calculating Uncertainties Using Data from precision & bias experiments
ANALYTICAL METHOD VALIDATION
World Health Organization
Chromatography Daheeya Alenazi.
Darrell Clinton and H. Dorota Inerowicz Purdue University
Damiana Gentili Qualified Person/QU Director 09/05/2019
Presentation transcript:

Validation of the AOAC method for pesticides residues analysis in oranges and mandarins in LATU Marina Torres (1) 1, Lucía Alcarraz 1 (2) 1 Laboratorio Tecnológico del Uruguay (LA.T.U) (1) (2) All over the world pesticides are used to control plagues on excessively worked lands. However, although they could be necessary, these can have negative effects on population. Clearly, this is the situation in citrus production, so fruit growers and exporters need a laboratory available with validated and accredited methods for the corresponding analyses. In Uruguay, the European Union is one of the most important buyers for citrus fruits. Consequently, as an answer to maximum residues limits demanded by UE legislation, we present in this work an analytical method developed in order to satisfy these requirements. Based on the AOAC official method [1], we validated a methodology using GC-μECD and HPLC-FLD with GC-MS confirmation for Malathion, Chlorpyriphos, Captan, Folpet, Prochloraz, Imazalil, Thiabendazole (TBZ) and o-Phenylphenol (OPP) EQUIPMENT: HPLC Agilent 1100 with: Fluorescence Detector G1321A Automatic Injector Agilent 1313A Column: C18 15 cm x 4.6 mm x 5 µm and C18 15 cm x 4.6 mm x 3 µm HRGC Agilent 6890 with: µECD Agilent Automatic Injector Agilent 7683B Column: DB-XLB 30 m x 250 µm x 0.25 µm Electronic Pressure control HRGC Agilent 7890A with: LRMS Agilent 5975C Inert Automatic Injector Agilent 7683B Column: DB-XLB 30 m x 250 µm x 0.25 µm Electronic Pressure control EXPERIMENTAL: Sample is trated as in [1] and injected in GC-uECD for Malathion, Chlorpyriphos,Captan, Folpet, Prochloraz and Imazalil and in HPLC-FLD for Thiabendazole and o-Phenylphenol. The final extract with no change of solvent is used. Due to matrix effects the calibration curves are prepared in blank matrix except for o-Phenylphenol. HPLC-FLD analysis Injection volume: 15 µl mobile phase: H 2 O pH=2,5:ACN (50:50) for OPP H 2 O 1.5% NH 3 :ACN (80:20) for TBZ flow: 1.5 ml/min for OPP and 0.8 ml/min for TBZ oven temperature: 25 ºC FLD operating at nm HRGC-uECD analysis Injection volume: 2 µl (splitless) constant flow: 1.2 ml/min oven temperature: from 40ºC to 180 ºC (50 ºC/min) from 180 ºC (10`) to 230 ºC (10 ºC/min) from 230 ºC to 280 ºC (35 ºC) µECD temperature: 300ºC HRGC-LRMS analysis Injection volume: 1.2 µl (splitless) constant flow: 0.7 ml/min oven temperature: the same used in HRGC-uECD analysis Ionization source: EI 70 eV 250 ºC Quadrupole temperature: 150 ºC Interface temperature: 250 ºC 3-DETECTION LIMIT (LOD): To measure LOD we spike a minimum or 5 replicates of blank samples. Acceptance criteria signal to noise ratio >3 Malathion: 20 ug/Kg Clorpiriphos: 20 ug/Kg Captan: 20 ug/Kg Folpet: 20 ug/Kg Imazalil: 50 ug/Kg Prochloraz: 50 ug/Kg o-Phenylphenol: 10 ug/Kg Thiabendazole: 40 ug/Kg 4-QUANTITATION LIMIT (LOQ) : To measure LOQ we spike a minimum or 5 replicates of blank samples. Acceptance criteria: mean of recovery % with RSD% ≤ 20% [2] and signal to noise ratio >10. Malathion: 60 ug/Kg Clorpiriphos: 50 ug/Kg Captan: 50 ug/Kg Folpet: 50 ug/Kg Imazalil: 100 ug/Kg Prochloraz: 100 ug/Kg o-Phenylphenol: 25ug/Kg Thiabendazole: 100 ug/Kg 5-SPECIFICITY: Blank samples analyzed in the batches show no interferences 6-UNCERTAINTY: Expanded uncertainty, calculated using sum of squares of type A and B components of uncertainty with a probability of 95% k=2 : 20% CONCLUSIONS: The results show that FLD for HPLC and uECD for GC could be used with good results for routine application of QuEChERS method. *The analysis presented here is sensitive, accurate and useful for routine analysis. *We continued working in TBZ recovery in order to improve the results BIBLIOGRAPHY: [1]-Pesticide Residues in Foods by Acetonitrile Extraction and Partitioning with Magnesium Sulfate. AOAC Official Method , 2007 [2]- SANCO/10684/2009. Method Validation and Quality Control Procedures for Pesticides Residues Analysis in Food and Feed. VALIDATION DATA: 1-ACCURACY: Note: We measure trueness and precision of Isodrine in order to use it as an internal standard to control the process a- Trueness: we use as a measure of trueness the recovery from spiked blank samples (samples of oranges and mandarins that we confirmed they do not have detected levels of the pesticides of interest) For recovery we spiked the blank sample at different levels with each pesticide solution prepared in acetonitrile with 1% acetic acid. One level of spike is the MRL, and the others are above and below it. Acceptance criteria for recovery: % [2] Malathion : 88.3 – 111.3% ( µg/Kg ) Chlorpyriphos: 72.4 – 90.7% ( µg/Kg) Captan: 72.2 – 95.0% ( µg/Kg) Folpet: 71.4 – 97.6% ( µg/Kg) Imazalil: 76.0 – 105% ( µg/Kg) Prochloraz: 84.2 – 93.7% ( µg/Kg) O-Phenylphenol: 73.0 – 110.8% ( µg/Kg) Thiabendazole: 65.8 – 130.9% (60–10000 µg/Kg) Isodrine: 74.1 – 98.7% ( µg/Kg) b- Precision: For repeatability we analyzed in the same day a minimum or 5 replicates with the same analyst. For intermediate reproducibility we repeated the analysis during different days. Acceptance criteria RSD< 20 for levels above and equal the LOQ [2]. Repeatability: Malathion: RSDr= % Chlorpyriphos : RSDr= % Captan : RSDr= % Folpet : RSDr= % Imazalil : RSDr= % Prochloraz : RSDr= % O-Phenylphenol : RSDr= % Thiabendazole : RSDr= % Isodrine : RSDr= % Intermediate reproducibility : Malathion:100 µg/Kg iRSD R = 18.4% n=3 Chlorpyriphos : 100 µg/Kg iRSD R = 16.9% n=4 Captan : 100 µg/Kg iRSD R = 16.7% n=3 Folpet : 100 µg/Kg iRSD R = 2.4% n=2 Imazalil : 10000µg/Kg iRSD R =14.5% n=2 Prochloraz : 10000µg/Kg iRSD R = 18.8% n=2 O-Phenylphenol : 100 µg/Kg iRSD R = 12.9% n=4 Thiabendazole : 5000 µg/Kg iRSD R = 3,3% n= 2 Isodrine : 100 µg/Kg iRSD R = 7.8% n=5 2-CALIBRATION CURVE/LINEARITY: Note: the amount specified is expressed in ug/Kg in sample. For GC quantitation we used Mirex as internal standard. Malathion: µg/Kg r 2 =0.999 Chlorpyriphos : µg/Kg r 2 =0.999 Captan: µg/Kg r 2 = Folpet: µg/Kg r 2 = Prochloraz: µg/Kg r 2 = Imazalil: µg/Kg r 2 = Thiabendazole: µg/Kg r 2 =0.998 O-Phenylphenol: µg/Kg r 2 = Isodrine: µg/Kg r 2 = ACKNOWLEDGMENTS: Departamento de Desarrollo de Métodos Analíticos-LATU, for their contributions to this work. This work is part of the final experimental work of L. Alcarraz to get the Quimica Farmacéutica degree from Facultad de Quimica UdelaR