Examination Techniques for Accuracy and Efficiency Astigmatism Detection and Management Options A VOSH-Florida Presentation.

Slides:



Advertisements
Similar presentations
Technician role in fitting lenses
Advertisements

VisTor The new Toric IOL by Hanita Lenses
Introduction to Refractive Error and Prescription Writing Walter Huang, OD Yuanpei University Department of Optometry.
Measurement of lens power by Lensometer
Theme 8: Astigmatism Concept of Astigmatism Formation of the retinal image Quantifying Astigmatism Classifying Astigmatism Retinal Image of the astigmatic.
PRESENTED BY T.Muthuramalingam
Astigmatism.
G UIDELINES FOR PRESCRIBING OPTICAL DEVICES AND TRAINING 23 February 2012.
Monovision for Presbyopia Insert name/ Practice name/ Logo here if desired.
PRACTICE OF REFRACTION
Lens and its forms Faculty Aravind School of Optometry.
OPTOMETRIC EQUIPMENTS IN REFRACTION ROOM
Physiological optics 9 th lecture Dr. Mohammad Shehadeh.
Example A 2.0 cm high object is placed 5 cm in front of a +10 cm focal length lens. Where is the object located? Is it real or virtual? Find the height.
Reflection & Mirrors.
Homework Set 5: Due Wednesday, March, 17 From Chapter 5: P2, P8, P10, P11, From Chapter 6: P1, P2, P6, PM2,
Clinical Refraction Procedure Presented by T.Muthuramalingam.
Theory of Retinoscopy.
Optics 1----by Dr.H.Huang, Department of Applied Physics
The Camera The single-lens photographic camera is an optical instrument Components Light-tight box Converging lens Produces a real image Film behind the.
Subjective refraction
Walter Huang, OD Yuanpei University Department of Optometry
Refractive Lens Exchange. 2 How the eye works Light rays enter the eye through the clear cornea, pupil and lens. These light rays are focused directly.
New Patented Free-Form Technology Surpasses All Others in Thinness and Design.
REFRACTIVE ERRORS SPS Y WHAT ARE WE GOING TO DO TODAY? Illustrate how light is brought into focus on the retina Associate refractive errors.
THE HUMAN EYE SUAAD MOHAMMAD ERIN OLSON Refraction and Converging Lenses.
CLINICAL APPROACH TO REFRACTIVE ERRORS
3-D Vision One person holds test tube at arms length Other holds pencil in arm upright Try to swing down lower arm to place pencil directly in test tube.
Retinoscopy OP1201 – Basic Clinical Techniques Part 2 - Astigmatism
Refraction and Lens. Refraction Refraction: the change in direction of a wave as it crosses the boundary b/w 2 media in which a wave travels different.
Physiological optics 12th lecture
Optical Instruments. Power of a lens Optometrists, instead of using focal length, use the reciprocal of the focal length to specify the strength of eyeglasses.
Keratometry Walter Huang, OD Yuanpei University Department of Optometry.
Optics instrumens Eye Eye Lup Lup Microscoope Microscoope Teropong Teropong.
The Human Eye Written for Physics 106 Friday, Nov. 7, 2008 A good web site for learning much about the anatomy of the human eye is :
Physics 213 General Physics Lecture Last Meeting: Diffraction Today: Optical Instruments.
Magnifiers, Projectors, CamerasPaul Avery (PHY 3400)1 Magnifiers, Projectors, Cameras Applied Optics Paul Avery University of Florida
Corrective lenses – refer ICEE ppt: L02 lens power P.S.Selvakumar Faculty Aravind School of Optometry.
Optics for Residents Astigmatic Lenses Amy Nau, OD.
Conductive Keratoplasty (CK) Insert name/ Practice name/ Logo here if desired.
Subjective refraction
Eye (Relaxed) Determine the focal length of your eye when looking at an object far away.
Subject 7: The lens-meter: Measuring Posterior Vertex Power. Description of the lens-meter Calibrating the instrument Measuring Posterior Vertex Power.
Retinoscopy OP1201 – Basic Clinical Techniques Part 1 – Spherical refractive error Dr Kirsten Hamilton-Maxwell.
Optics for Residents Astigmatic Lenses Amy Nau, OD.
Training and Certification
Emmetropia and the Ametropias Scott P. Drexler OD University of Pittsburgh School of Medicine.
Chapter 27 Lenses and Optical Instruments. Lenses Converging lens Diverging lens.
Senses Lab: Sight How do our eyes work? Why do they work this way?
REFRACTION Dr. Puneet Kumar Srivastava. Refraction Def: Method of evaluating the optical state of eye. Or The process by which the patient is guided through.
REFRACTION Dr. Puneet Kumar Srivastava. Refraction Def: Method of evaluating the optical state of eye. Or The process by which the patient is guided through.
REFRACTION Dr. Puneet Kumar Srivastava. Refraction Def: Method of evaluating the optical state of eye. Or The process by which the patient is guided through.
Visual acuity and color vision. Aims and Objectives Understand the principles behind vision testing Perform an accurate visual acuity To differentiate.
The Eye The sensory receptors in your eye detect light energy. The receptors are stimulated by light rays, which enter your eyes after bouncing off objects.
The Human Eye Focus and Vision Correction. Path of Light Cornea Cornea Pupil Pupil Lens Lens Vitreous humor Vitreous humor Retina Retina Optic Nerve (electrical.
Objective method of refraction retinoscopy
Introduction to Retinoscopy
OPTO 4101: Refraction1 Subjective verification for refraction
Examination Techniques for Accuracy and Efficiency
Review of geometrical optics
OPTO 4101: Refraction1 Subjective verification for refraction
Examination Techniques for Accuracy and Efficiency
Examination Techniques for Accuracy and Efficiency
OPTO 4101: Refraction1 Subjective verification for refraction
Examination Techniques for Accuracy and Efficiency
Examination Techniques for Accuracy and Efficiency
Astigmatism.
Examination Techniques for Accuracy and Efficiency
Examination Techniques for Accuracy and Efficiency
Examination Techniques for Accuracy and Efficiency
Presentation transcript:

Examination Techniques for Accuracy and Efficiency Astigmatism Detection and Management Options A VOSH-Florida Presentation

Brief review of Astigmatism Measuring astigmatism using a retinoscope and lens (skioscopy) rack Measuring astigmatism using trial lenses Measuring astigmatism using a hand- held Jackson Cross Cylinder (JCC) Refracting to spherical equivalence Prescribing Concerns

Astigmatism: – generally defined as a non-spherical or toric anterior corneal curvature, resulting in incident rays of light having multiple points of focus: –Regular – Maximum and minimum refractive angles are separated by 90 degrees. –Irregular - Maximum and minimum refractive angles are separated by other than 90 degrees (pterygia, keratoconus, corneal scars). –Lenticular – astigmatism induced by a tilting of the crystalline lens (minimal, insignificant).

Uncorrected Regular Astigmatism: –Results in a Circle of Least Confusion, or the dioptric midpoint between the major lines of focus.

Uncorrected Astigmatism – Associated Clinical Symptoms : –Headaches/fatigue (squinting) –Distance blur –Near blur –Photophobia/glare –Night vision problems (blur/glare) –Pseudo-diplopia (ghost images)

Measuring astigmatism using a retinoscope and lens (skioscopy) rack: –Place the trial frame on the patient. –Place your working distance trial lens over each eye (+1.50D for 65cm). Do not occlude either eye. –Scope over the trial lens to determine the 2 principal meridians. –Hold up the lens rack (+ or – as needed) and scope the least minus or most plus meridian (strongest “against” motion or weakest “with” motion). –Move the lens rack to neutralize this meridian (“with motion” – add minus; “against motion” – add plus) –Add the appropriate spherical trial lens to the trial frame.

Measuring astigmatism using a retinoscope and lens (skioscopy) rack –Next, hold up the lens rack (+ or – as needed) and scope the most minus or least plus meridian. –Move the lens rack to neutralize this meridian, which will show “with” motion. –Add the appropriate (-) cylinder trial lens to the trial frame at the determined axis.

Measuring astigmatism using a retinoscope and lens (skioscopy) rack –Repeat this procedure with the other eye. –When both eyes have been refracted, remove the working distance lens from each eye. –Proceed with the subjective refraction.

Measuring astigmatism using trial lenses –After obtaining the objective refraction using either a retinoscope or autorefractor (minus cylinder approach): Place the spherical correcting lens in the trial frame for each eye. Place the (-) cylinder correcting lens in the trial frame for each eye. Occlude the eye not being tested. Increase or decrease the sphere power for sharpest focus, bringing the Circle of Least Confusion onto the retina.

Measuring astigmatism using trial lenses Add a fogging lens of ~ diopters. Slowly rotate the cylinder lens in the trial frame until the patient states that the acuity chart or meridian line on the astigmatic dial appears sharpest. Increase or decrease the cylinder power to achieve sharpest focus, bringing the two principle meridians into focus in front of the retina. Slowly reduce fog by decreasing (+) or increasing (-) sphere power to achieve sharpest focus. Both principle meridians will be focused on the retinal plane at this point.

Measuring astigmatism using a hand-held Jackson Cross Cylinder (JCC) –After obtaining the objective refraction using either a retinoscope or autorefractor (minus cylinder approach): Place the spherical correcting lens in the trial frame for each eye. Place the (-) cylinder correcting lens in the trial frame for each eye. Occlude the eye not being tested. Increase or decrease the sphere power for sharpest focus, bringing the Circle of Least Confusion onto the retina.

Measuring astigmatism using a hand-held Jackson Cross Cylinder (JCC) Add a fogging lens of ~+0.50 diopters. Hold the JCC with the axis mark aligned with the axis of cylinder trial lens. Flip the JCC. On the side giving the sharper image, rotate the trial lens axis towards the Red mark on the JCC (“Chase the red”). When image appears equally blurred on flipping the JCC, the axis has been located.

Measuring astigmatism using a hand-held Jackson Cross Cylinder (JCC) Rotate the JCC, placing the power dot on the axis. Flip the JCC. If red dot is sharper, add minus cyl. If white dot is sharper, reduce minus cyl. For every increase of cyl, add to the sphere. For every decrease of cyl, add to the sphere. When image appears equally blurred on flipping the JCC, the power has been determined.

Measuring astigmatism using a hand-held Jackson Cross Cylinder (JCC) Remove the JCC Slowly reduce fog by decreasing (+) or increasing (-) sphere power to achieve sharpest focus. Both principle meridians will be focused on the retinal plane at this point. Adjust for spherical equivalent if necessary.

Refracting to Spherical Equivalence –Uncorrected Regular Astigmatism: Results in a Circle of Least Confusion, or the dioptric midpoint between the major lines of focus.

Refracting to Spherical Equivalence –The circle of least confusion is the point of least blur between the two principle meridians of an eye with regular astigmatism. –The closer the focal plane of each principle meridian to the other, the sharper the focus at the circle of least confusion. –When both principle meridians are focused at the same plane, circle of least confusion is at its sharpest focus.

Refracting to Spherical Equivalence –The goal is to bring the circle of least confusion to sharpest focus and at the plane of the retina. –Refracting an astigmatic eye using sphere only correction will result in a less sharp image than a sphero-cylinder correction. –Sphere-only correction may be faster, cheaper, and provide adequate vision without adaptation problems.

Refracting to Spherical Equivalence –Pros of sphere-only correction: Faster Less skill required Less expensive lenses Possibly less adaptation problems

Refracting to Spherical Equivalence –Cons of sphere-only correction: Possible symptoms: –Asthenopia –Accommodative spasms –Less sharp vision at distance and near

Refracting to Spherical Equivalence –Refracting Methods: Spherical trial lenses: –Find least minus or most plus sphere that provides sharpest image. Retinoscope and trial lenses: –Scope principle meridians to determine sphero-cylinder correction. –Calculate spherical equivalent and place sphere lenses in trial frame. –Sphere + ½ Cylinder = Spherical Equivalent

Refracting to Spherical Equivalence –Modified Spherical Equivalent Method: Determine sphero-cylindrical correction. Cut powers to maintain Circle of Least Confusion on retina. Choose least cylinder that gives sharpest vision and comfort. –Reduce cylinder power by -0.50D, reduce sphere power by –Example: – 1.00 x 180(sharpest image) – 0.50 x 180(moderately sharp image) sph(least sharp image)

Refracting to Spherical Equivalence –Modified Spherical Equivalent Method: By reducing the cylinder power, while maintaining the Circle of Least Confusion on the retina: –provides an acceptably sharp image. –reduces adaptation problems, while introducing cylinder. –eliminates asthenopia and accommodative spasms.

Correcting Astigmatic Errors: –Adaptation/Prescribing Tips: Small changes in cylinder power or axis can produce perceptual problems. It may be necessary to introduce the cylinder correction gradually. Prescribing reduced cylinder while maintaining the circle of least confusion on the fovea may improve adaptation.

Correcting Astigmatic Errors: –Adaptation/Prescribing Tips: Adults with chronic, uncorrected high astigmatism may not respond to cylinder correction due to the development of meridional amblyopia. Prescribing increasing amounts of cylinder over time may aid in breaking down meridional amblyopia. Younger patients will typically show with-the-rule astigmatism. Older patients will develop against-the-rule astigmatism due to aging changes in the crystalline lens.