BIOMECHANICAL PROPERTIES OF THE CORNEA IN PSEUDO-EXFOLIATION SYNDROME Aylin Kılıç Ertan, MD Özgür Bilen, MD Kudret Eye Hospital, Ankara, Turkey There is.

Slides:



Advertisements
Similar presentations
Biomechanical Properties of the Cornea in Normal- Tension Glaucoma Authors: Leonidas Traipe Ines Cayuqueo Fabiola Cerfogli Claudia Goya Allister Gibbons.
Advertisements

Statement of Commercial Interest: RDJ: None DRH: honoraria from Reichert for educational lectures on corneal biomechanics Multiple studies have shown ex.
Corneal biomechanical properties and their association with intraocular pressure (IOP) and central corneal thickness (CCT) Dimitrios P. Bessinis 1, Pandelis.
Live tissue imaging (cornea) Optical imaging of tissue  cells Histology and Electron Microscopy can image ECM. Requires sectioning and staining. Stroma.
A Prospective Trial Evaluating Scleral Rebound Tonometry Sara Duke, MD, Andrew Logeman, Shuchi Patel, MD Loyola University Chicago, Department of Ophthalmology,
Recent Advances in IOP measurements
Comparison between Dynamic contour tonometry, Goldmann applanation tonometry and Ehlers-corrected Goldmann applanation tonometry in eyes after Laser In.
Katsuya Yamazoe, MD, Takefumi Yamaguchi, MD, Kazuki Hotta, MD, Yoshiyuki Satake, MD, Kenji Konomi, MD, Seika Den, MD, Jun Shimazaki, MD Presented by: Abdulrahman.
Influence of Keratoplasty Technique on Corneal Biomechanical Properties in Keratoconus Hans R Vellara, Noor Q Ali, Charles NJ McGhee, Dipika V Patel Department.
Biomechanical Properties of Healthy and Keratoconic Corneas Evaluated Using an Ultra-High-Speed Scheimpflug Camera nznec Department of Ophthalmology University.
Corneal Biomechanics, Pachymetric Progression Profile and Corneal Volume: Indices for Detecting Ectasia and Screening Refractive Candidates Renato Ambrósio.
E-Poster ALC Canedo, MD 2010 Rio de Janeiro CornealTomograhyandBiomechanics Study Group Study Group Comparative Study of Corneal Biomechanical Properties.
Aqueous Humor and Plasma Levels of Vascular Endothelial Growth Factor and Nitric Oxide in Patients with Pseudoexfoliation Syndrome and Pseudoexfoliation.
LASIK What are the Limits ?
CR The Glaucoma Tonometer. What sets it apart? Reichert’s 7CR Auto Tonometer + Corneal Response Technology takes corneal biomechanical properties into.
Understand the Cornea Understand the Pressure
Outcome of refractive surgery in keratoconus suspect eyes
University of Verona Eye Clinic Department of Neurological and Motor Science Head: Prof. Giorgio Marchini Prevalence of Corneal Ectasia in Patients With.
Variations in corneal biomechanical parameters and central corneal thickness during the menstrual cycle. David Zadok, MD, Yakov Goldich, MD, Yaniv Barkana,
A Prospective Trial Comparing Scleral Pneumotonometry to Goldmann Applanation Tonometry Sara Duke, MD, Usiwoma Abugo, BS, Shuchi Patel MD Loyola University.
ICT – Intraoperative Corneal Topography for image registration purposes S.Schründer.
TRANSPALPEBRAL TONOMETER APPLICATION DURING INTRAOCULAR PRESSURE EVALUATION IN THE PATIENTS WITH REFRACTION ANOMALY BEFORE AND AFTER KERATOPHOTOREFRACTIVE.
Correlation Between Corneal Biomechanics and Wavefront Aberrations Alejandro Rivera, MD Private Practice Mexico City The author has no financial interest.
TARIQ ALASBALI WHICH PATIENTS ARE AT RISK FOR THE PROGRESSION?
Retinal nerve fiber layer thickness change in patients with wet AMD treated with ranibizumab, short term results Advantages: To determine the effect of.
Glaucoma Screening With a New Non-Contact Air Impulse Tonometer Pandelis A. Papadopoulos,1,2, Dimitrios P. Bessinis 3, Alexandros A. Papadopoulos 1, Konstantinos.
Relationship between Pachymetry and Ocular Response Analyzer Measurements Alejandro Rivera MD.
Tear-film Stability in Patients with Obstructive Sleep Apnea Syndrome Masaki Sato, MD Tetsuro Oshika, MD Department of Ophthalmology University of Tsukuba.
Pachymetric changes during corneal collagen cross-linking and effect of hydroxipropylmethylcellulose on corneal thickness Faik Oruçoğlu (Orucov) Kudret.
Assessment of wave propagation in mice cornea and lens using phase stabilized swept source optical coherence tomography Ravi K. Manapuram, Floredes M.
Oliver Findl 1,2, Nino Hirnschall 1,2, Alja Crnej 2 1 VIROS Vienna Institute for Research in Ocular Surgery, Hanusch Hospital, Vienna, Austria 2 Moorfields.
Photorefractive Keratectomy in Posterior Polymorphous Dystrophy [CONTROL ID: ] Edward W. Trudo 1, Kraig S. Bower 2, Charles D. Coe 2, Denise A. Sediq.
Effect of Corneal Thickness on Selective Laser Trabeculoplasty to Decrease Intraocular Pressure as Primary or Secondary Treatment of Glaucoma ASCRS 2010.
Variations in corneal biomechanical parameters and central corneal thickness during the menstrual cycle. Yakov Goldich, MD, David Zadok MD, Yaniv Barkana,
Confocal scan study of corneal grafts following Descemet-on versus Descemet-off deep anterior lamellar keratoplasty Zare M, Feizi S, Rezaie M, Hoseini.
Biomechanical and Optical Behavior of Human Corneas Before and After Photorefractive Keratectomy Anna Pandolfi, Politecnico di Milano, Italy Paolo Sanchez,
Combined cataract surgery and endoscopic cyclophotocoagulation in patients with glaucoma without prior incisional glaucoma surgery Matthew P. Traynor,
Naomi R. Goldberg, MD PhD Kenneth J. Wolf, MD Eric J. Wolf, MD FACS The authors have no financial interest in the subject matter of this poster. Comparison.
A Prospective Trial Comparing Pneumotonometry of Cornea and Sclera Usiwoma Abugo BS 1, Sara Duke MD 2, Shuchi Patel, MD 2 1 Loyola University Chicago,
Urrets-Zavalia Syndrome After Lamellar Corneal Transplant: Two Case Reports Timothy Y. Chou, MD, Sujata P. Prabhu, MD, Justin Dexter, MD Department of.
*Kagithane State Hospital,Department of Ophthalmology,Istanbul, Turkey DR.GÖKHAN KAYA *Kagithane State Hospital,Department of Ophthalmology, No author.
E-Poster Rio de Janeiro Corneal Tomography and Biomechanics Study Group The study of the correlations of the optic disc size with Cornal Geometry and Biomechanical.
E-Poster Rio de Janeiro Corneal Tomography and Biomechanics Study Group e-Poster Rio de Janeiro Corneal Tomography and Biomechanics Study Group Clinical.
The effect of corneal edema on intraocular pressure measurements after phacoemulsification surgery Ilker Eser M.D. 1 Arzu Taskiran-Comez M.D. 1 Baris Komur.
Ahmed El-Massry, M.D. Professor of Ophthalmology - Faculty of Medicine University of Alexandria Egypt long-Term Results of Corneal Biomechanical Changes.
Ocular Response Analyzer Waveform Analysis in the Ectatic Corneas: Correlation of the New Corneal Biomechanics Parameters and Severity of Keratoconus Kristin.
Faik Orucov*, MD, Joseph Frucht-Pery, MD, David Landau, MD, Eyal Strassman, MD, Abraham Solomon, MD Clinical outcome of thin corneas after laser in situ.
Comparative biomechanical analysis of combined treatments for keratoconus M. A. del Buey 1, E. Lanchares 2, J. A. Cristóbal 1, B. Calvo 2, M. Doblaré 2.
Corneal Hysteresis Role of Corneal Biomechanics in Refractive Surgery Luis Rodriguez, MD Anny Villegas, MD Clínica de Córnea Centro Médico Docente La Trinidad.
Mathematical Description of the Ocular Response Analyzer Applanation Signal in Post-LASIK Ectasia Mujtaba A. Qazi, M.D. 1,2 David A. Luce, Ph.D. 3 Jay.
Corneal Biomechanical Changes Following Surface Keratorefractive Surgery Teeravee Hongyok, MD, Christopher J. Rapuano, MD, Ajoy Virdi, MBBS, Elisabeth.
Instituto para Preservación de la Visión
Pseudoexfoliation syndrom and cataract: results and complication frequency in immature and mature cataract surgery Marijana Bilen Babić Department of.
CRF variations ( initial CRF – final CRF )
Intraocular pressure & tonometry
55th ASMR National Scientific Conference
JP Deva COMPARISON OF PRELIMINARY RESULTS FROM CROSSLINKED KERATOCONUS AND NORMAL CORNEAE USING ORA JP Deva
Influence of UVA-Riboflavin corneal collagen cross-linking on biomechanical properties of keratoconic eyes David Zadok MD, Yakov Goldich MD, Yaniv Barkana.
Effects of corneal collagen crosslinking on Ocular Response Analyzer waveform-derived variables in keratoconus and post-LASIK ectasia Spatial treatment.
Wylegala Edward, Nowinska Anna
Keratometric Changes in Noninflammatory Corneal Ectasic Diseases After Intraocular Pressure Reduction Authors has no financial interest. Renata T Kashiwabuchi,
Associate Professor of Ophthalmology
Federal University of São Paulo, Brazil
Elena Albé MD Paolo Vinciguerra MD, Silvia Trazza, MD
Bruno Valbon, Ana Caiado, Ricardo Louzada, Renato Ambrosio Jr *.
Corneal Biomechanical Assessment using Dynamic Ultra High-Speed (UHS)
Yakov Goldich MD,Yaniv Barkana MD, Isaac Avni MD, David Zadok MD,
Corneal Biomechanics after Penetrating Keratoplasty and Descemet’s Stripping Automated Endothelial Keratoplasty Samer Hamada MRCOphth FRCS(Ed)1,3 Louai.
Hyuck Jin Choi, Joo Youn Oh, Won Ryang Wee, Mee Kum Kim,
Jun Her MD. PhD, Sung-wook Kim MD, Jae-hwan Ahn MD
Presentation transcript:

BIOMECHANICAL PROPERTIES OF THE CORNEA IN PSEUDO-EXFOLIATION SYNDROME Aylin Kılıç Ertan, MD Özgür Bilen, MD Kudret Eye Hospital, Ankara, Turkey There is no financial interest

 IOP measurement depends on:  Corneal thickness  Corneal curvature  Corneal rigidity ?

 Low CH is a risk factor for a tendency toward IOP underestimation  Falsely low IOP readings create the risk for misdiagnosis of potential glaucoma patients with PSX, resulting in missed or delayed glaucoma detection.

Corneal Hysteresis (CH) visco-elastic corneal tissue response to a dynamic deformation difference between inward and outward applanation pressures Corneal resistance factor (CRF) Linear combination of inward and outward applanation pressures, designed for maximal correlation with central corneal thickness CH and CRF : between 8 and 15 mmHg. Figure courtesy of Reichert

Low Hysteresis  Keratoconus  Fuchs  After corneal laser ablation  Pseudoexfoliation syndrome ??

Purpose  To compare corneal biomechanic properties between eyes with pseudo- exfoliation syndrome (PSX) and normal eyes

Method  Prospective study  76 eyes of 76 patients  Group 1: PSX (+), 41 eyes  Group 2: control, 35 eyes  CH, CRF and IOPcc were compared according to groups

Including criterias in Group 1: 1. eyes with manifest PSX material in precapsular layer and with or without PSX on pupil edge 2.eyes without glaucoma diagnosis

Gr 1Gr 2 p value PSX(+)PSX(-) IOPcc (mmHg)18,717,60.05  CH (mmHg)8,49,50.05  CRF (mmHg)8,910,  Results T-test

Conclusion  There is low hysteresis in eyes with PSX without glaucoma  This may cause misdiagnosis of potential glaucoma patients  Special attention is necessary during IOP monitoring in eyes with PSX