Status of GaAs Photoemission Guns at JLab M. Poelker, P. Adderley, M. Baylac, J. Brittian, D. Charles, J. Clark, J. Grames, J. Hansknecht, M. Stutzman,

Slides:



Advertisements
Similar presentations
Source Outlook High polarization strained-layer photocathodes were activated in both electron guns during the summer shutdown, with usual QE (0.2% at 850.
Advertisements

CEBAF Photoinjector: What’s new, what’s the same since HAPPEx 2004? What needs to be done? M. Poelker, HAPPEx collaboration meeting, Feb. 18, 2005.
Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. of Energy M. Poelker,
Chris Tennant Jefferson Laboratory March 15, 2013 “Workshop to Explore Physics Opportunities with Intense, Polarized Electron Beams up to 300 MeV”
Polarized Electron Source R&D at CEBAF/JLab P. Adderley, J. Brittian, J.Clark, J. Grames, J. Hansknecht, M.Poelker, M. Stutzman, R. Suleiman Students:
GaAs and CsKSb Photocathodes for DC Gun
ILC Polarized Electron Source Annual DOE HEP Program Review June 5 – 8 International Linear Collider at Stanford Linear Accelerator Center A. Brachmann,
CEBAF Polarized Electron Source: Outlook & Horizon Operations Group Meeting May 13 th & 20 th, 2009 Joe Grames M. Poelker, P. Adderley, J. Clark, J. Grames,
PST05 Workshop, Nov 14-17, 2005 M. Farkhondeh 1 Polarized Electron Sources for Future Electron Ion Colliders M. Farkhondeh, Bill Franklin and E. Tsentalovich.
Ops Review, Jan , 2002, 1 Operated by the Southeastern Universities Research Association for the U.S. Depart. Of Energy Thomas Jefferson National.
Hall A Parity Workshop (May 10, 2002), 1 Operated by the Southeastern Universities Research Association for the U.S. Depart. Of Energy Thomas Jefferson.
1) Source Issues 2) SLAC’s ITF Jym Clendenin SLAC.
/SC-PAC Operated by the Southeastern Universities Research Association for the U.S. Depart. Of Energy Joe Grames CEBAF Operations
High Current Electron Source for Cooling Jefferson Lab Internal MEIC Accelerator Design Review January 17, 2014 Riad Suleiman.
Operated by the Southeastern Universities Research Association for the U.S. Depart. Of Energy Thomas Jefferson National Accelerator Facility Strained Superlattice.
Compton polarimetry for EIC Jefferson Lab Compton Polarimeters.
Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. of Energy M. Poelker,
Operated by Jefferson Science Associates, LLC for the U.S. Department of Energy Thomas Jefferson National Accelerator Facility Polarized Electron Beam.
ExperimentEnergy (GeV) Pol (%) I (µA) TargetA pv (ppb) Maximum Charge Asym (ppb) Maximum Position Diff (nm) Maximum Angle Diff (nrad) Maximum Size Diff.
Measurements of Photocathode Operational Lifetime
Operated by the Southeastern Universities Research Association for the U.S. Department Of Energy Thomas Jefferson National Accelerator Facility M. Poelker,
Probing Hadron Structure at CEBAF Using Polarized Electron Scattering M. Poelker, Jefferson Lab APS Meeting, Dallas, TX, April 2006 Structure Functions,
CLIC meeting, October 16-18, 2007 High Polarization DC High Voltage GaAs Photoguns P. Adderley, J. Brittian, J.Clark, J. Grames, J. Hansknecht, M.Poelker,
9/24-26/07 e- KOM Slide 1/20 ILC Polarized e- source RDR Overview A. Brachmann.
Thomas Jefferson National Accelerator Facility G0 Collaboration Meeting, June 18-19, 2003 Updates G0 Tiger Laser High Polarization Photocathodes Mott polarimeter.
The CEBAF 200kV Inverted Gun P. Adderley, M. BastaniNejad, J. Clark, J. Grames, J. Hansknecht, J. McCarter, M. Poelker, M. Stutzman, R. Suleiman, K. Surles-Law.
Recent Polarized Cathodes R&D at SLAC and Future Plans Feng Zhou Axel Brachmann, Jym Clendenin (ret.), Takashi Maruyama, and John Sheppard SLAC Workshop.
LDRD: Magnetized Source JLEIC Meeting November 20, 2015 Riad Suleiman and Matt Poelker.
DC photogun vacuum characterization through photocathode lifetime studies Marcy L. Stutzman, Philip Adderley, Joseph Grames, Matthew Poelker, Ken Surles-Law.
PSTP 2007, Brookhaven National Lab, September 10-14, 2007 High Intensity Polarized Electron Sources M.Poelker, P. Adderley, J. Brittian, J.Clark, J. Grames,
Operated by the Southeastern Universities Research Association for the U.S. Depart. Of Energy Thomas Jefferson National Accelerator Facility Lifetime Measurements.
Electron Sources for ERLs – Requirements and First Ideas Andrew Burrill FLS 2012 “The workshop is intended to discuss technologies appropriate for a next.
4 th Electron-Ion Collider Workshop, Hampton University, Monday May 19 th, 2008 CEBAF Load-Lock Polarized Electron Photogun Joe Grames & Matt Poelker (Jefferson.
Source Systematics PITA - type effects The importance of controlling the analyzer-axis –Two Pockels cells –Half-wave plate Position asymmetries –Lensing.
MeRHIC Internal Cost Review October, Dmitry Kayran for injector group MeRHIC Internal Cost Review October 7-8, 2009 MeRHIC: Injection System Gun.
Injector Status & Commissioning QWeak Collaboration Meeting May 24, 2010 P. Adderley, J. Clark, S. Covert, J. Grames, J. Hansknecht, M. Poelker, M. Stutzman,
CEBAF Polarized Electron Guns Marcy L. Stutzman for the Jefferson Lab Polarized Source Group.
김 귀년 CHEP, KNU Accelerator Activities in Korea for ILC.
Page 1 Polarized Electron Sources for Linear Colliders October, 2010 A. Brachmann, J. C. Sheppard, F. Zhou SLAC SLAC October 18-22, 2010.
Development of High Current Bunched Magnetized Electron DC Photogun MEIC Collaboration Meeting Fall 2015 October 5 – 7, 2015 Riad Suleiman and Matt Poelker.
Parity Experiments and JLab Injector Riad Suleiman February 5, 2016.
TILC Electron Source Update A. Brachmann, J. Sheppard, F. Zhou -SLAC – M. Poelker - Jlab - TILC, Tsukuba, April 2009.
CEBAF Source and Injector Status PREx-II Collaboration Mtg Feb. 26, 2016 Matt Poelker and Joe Grames Center for Injectors and Sources.
G 0 Project Coordinator Report Joe Grames “Big Picture” Schedule Preparations Polarized Source Injector Accelerator Hall C Accelerator Plans for 687 MeV.
Operated by Jefferson Science Associates, LLC for the U.S. Department of Energy Thomas Jefferson National Accelerator Facility Polarized Electron Beams.
Operated by the Southeastern Universities Research Association for the U.S. Depart. Of Energy Thomas Jefferson National Accelerator Facility M. Baylac,
November 17, 2008 A. Brachmann Slide 1 ILC polarized Electron Source R&D Update LCWS 2008 A. Brachmann, J. Sheppard, F. Zhou - SLAC National Accelerator.
Parity Quality Beam (PQB) B-Team Meeting September 10, 2008.
Polarized Injector & Upgrade Schedule QWeak Collaboration Meeting November 06, 2009 P. Adderley, J. Clark, J. Grames, J. Hansknecht, M. Poelker, M. Stutzman,
A bit of CEBAF polarized source history…
An Electron source for PERLE
Polarized Injector Update
Polarized Electron Source for eRHIC (the ring-ring option)
A Mini-Primer for Parity Quality Beam (as seen from the Accelerator)
G0 Backward Angle Accelerator Preparations
G0 Accelerator Planning Meeting (11/1/05)
Further Measurements of Photocathode
Thoughts on why G0 needed position feedback and HAPPEX didn't
QWeak Collaboration Meeting
Magnetized Electron Beam for Ion Cooling at JLEIC
Atomic hydrogen exposure of strained layer GaAs photocathodes
ELIC Injector Working Group High-P, high-I source issues (DC)
GaAs Photocathode Performance
Strained Superlattice GaAs
Center for Injectors and Sources
R. Suleiman and M. Poelker October 12, 2018
High Current Prospects for Polarized Electron Sources
Shukui Zhang, Matt Poelker, Marcy Stutzman
MEIC Polarized Electron Source
Optimization of JLEIC Integrated Luminosity Without On-Energy Cooling*
Presentation transcript:

Status of GaAs Photoemission Guns at JLab M. Poelker, P. Adderley, M. Baylac, J. Brittian, D. Charles, J. Clark, J. Grames, J. Hansknecht, M. Stutzman, K. Surles-Law CEBAF: Gun lifetime Parity violation experiments Commercial Ti-sapphire lasers Superlattice Photocathodes Atomic H/D exposure Ion Pump supply with nA current monitoring JLab IRFEL: 10 kW output power 350 kV DC GaAs gun 9 mA CW ave current New Photoinjectors: 10’s of mA ave current at high polarization. Obstacles? Operated by the Southeastern Universities Research Association for the U.S. Depart. Of Energy Thomas Jefferson National Accelerator Facility M. Poelker, PESP2004, Oct.7-9, Mainz, Germany

CEBAF 2-Gun Photoinjector New cleanroom for lasers

Gun Charge Lifetime Measured over Gun Charge Lifetime Steadily Decreasing NEG pump replacement Summer 2003 improves lifetime M. Baylac 10 NEG pumps surround cathode/anode gap

Parity Violation Experiments at CEBAF Experiment Physics Asymmetry Max run-average helicity correlated Position Asym. Max run-average helicity correlated Current Asym. HAPPEX-I 13 ppm10 nm1.0 ppm HAPPEX-II1.3 ppm2 nm0.6 ppm HAPPEX-He8 ppm3 nm0.6 ppm G02 to 50 ppm20 nm1.0 ppm Qweak0.3 ppm20 nm0.1 ppm P-REx1 nm0.1 ppm completepartially completeapproved

G0 Forward Angle was a Difficult Experiment Very long experiment!  “commissioning” run: August 2002 – January 2003  “engineering” run: October 2003 – February 2004  “production” run: March 2004 – May MHz time structure caused problems;  Homemade lasers could not generate 70 ps pulses  Homemade lasers were not long-term stable  High bunch charge caused beam handling problems Managing helicity correlated position asymmetry was painful, at least initially.

Injector acceptance 111 ps 1 uA 2 uA 8 uA 20 uA 40 uA 70 uA Significant bunchlength growth Beam profile distortion when laser spot tightly focused at photocathode Lots of beamloss at apertures Current from gun Current delivered to Hall Aperture loss 8 times Higher Bunchcharge; ~ 2 pC/pulse

G0 Exp used active feedback to control asymmetries - Pockel cell aligned using spinning linear polarizer -Rotating halfwaveplate sets asymmetries close to zero before turning feedback ON. - IA cell (waveplate+pockel cell+linear polarizer) used to correct charge asymmetry. - PZT mirror used to correct position asymmetries. - Helicity correlated charge and position asymmetry seen to converge to zero over the course of a few hours. Helicity correlated differences integrated over a few hours. Correlations: - Position differences induce charge asymmetry through scraping. - Charge asymmetry induces energy and position differences through rf cavity loading. - Position differences “appear” as energy differences at the dispersive point.

Helicity Correlated Beam Specs for g0 Forward Total of 744 hours (103 Coulombs) of parity quality beam with a 4  cut on parity quality. All parity quality specs have been achieved!! Beam Parameter Achieved (IN-OUT) “Specs” Charge asymmetry ± 0.28 ppm 1 ppm x position differences 6 ± 4 nm20 nm y position differences 8 ± 4 nm20 nm x angle differences 2 ± 0.3 nrad2 nrad y angle differences 3 ± 0.5 nrad2 nrad Energy differences 58 ± 4 eV75 eV

Commercial Laser was critical to success of experiment. Cavity length ~ 5 m Tunable over ~ 20 nm at 780 nm and 850 nm. Etalons provide range of pulsewidths from 10 p to 70 ps. More than 250 mW power

499 MHz modelocked Ti- sapphire lasers for high current polarized beam experiments (~ 100 uA ave.) 300 to 500 mW output power 770 nm or 850 nm operation Stable phase-locked pulse train Maintenance required

HAPPEx Approach In the Laboratory;  Compare pockels cells from different vendors  Choose cell with smallest birefringence gradient In the Tunnel;  Without cell, verify good optics and laser polarization.  Align insertable halfwaveplate for 90 degree rotation.  Align pockel cell  Minimize optical beam steering by positioning laser on geometric center of cell. With Beam;  Verify laser table measurements; plot e-beam HC position and intensity asymmetry vs rotating halfwave plate orientation for “ideal” cell voltages. Asymmetries should be small.  Adjust rotating waveplate orientation and cell voltages to minimize beam asymmetries. Use IA cell to apply charge asymmetry feedback. Minimize asymmetries at outset via careful choice and alignment of pockel cell. No position feedback.

Gun2 strained layer GaAsGun3 superlattice GaAs From HAPPEx-H 14 mm Gun3 lifetime was poor Frequent laser spot moves were necessary QE holes caused HC asymmetry variations Final beam quality numbers pending but preliminary results indicate HC specifications were met;

Superlattice Photocathode from SVT The highest polarization yet measured at CEBAF; ~ 85% QE 0.8% versus 0.15% Analyzing power 4 % versus 12% Preliminary photon electron From Hall A Compton Polarimeter Polarization QE (%) Analyzing Power Wavelength (nm) here

SVT Superlattice Summary Highest polarization ever measured at JLab: P = 85% Measurements of many samples at test stand indicates this is no fluke. 5 times higher QE than strained layer GaAs material (not yet demonstrated at tunnel). Smaller analyzing power should provide smaller inherent charge and position asymmetry. (Recent HAPPEx results do not support this claim.) We suffered surface charge limit. QE drops with increasing laser power. A concern for high current experiments like Qweak. QE not constant

QE vs hydrogen cleaning Hydrogen exposure time (min) QE (%) Drawback: Superlattice material is delicate Can’t clean with atomic hydrogen Makes it tough to anodize edge of photocathode Typical H-dose to clean anodized samples From M. Baylac et al., in press

Ion Pump Locations Pumps detect bad orbit and beamloss Gun chamber pump Y-chamber Laser chamber Wien filter Ion Pump Power Supplies with nanoA Current Monitoring Designed and constructed by J. Hansknecht “Free” pressure monitoring at 10^-11 Torr

Ave. Power (kW) 10 kW for 1 sec. (2.5 kW ave power at ¼ DF) Courtesy C. H. Garcia and JLab FEL team

Operated by the Southeastern Universities Research Association for the U.S. Depart. Of Energy Thomas Jefferson National Accelerator Facility FEL The JLAB FEL Injector is driven by a 350 kV DC GaAs Photocathode Gun 40 cm PHOTOCATHODE PERFORMANCE Photocathode QE~6% after initial activation at 532 nm Photocathode delivers ~200 C between re-cesiations Typical day of operations draws ~35 Coulombs About 96% of previous QE is recovered with each re-cesiation 12 activated cathodes and close to 40 re-cesiations performed on a single GaAs wafer in one year Photocathode Ball cathode Drive Laser Courtesy C. H. Garcia and JLab FEL team

Demonstrated DC Photocathode Gun performance at JLab IR-FEL Macropulse operation at 8 mA, 16 ms-long pulses at 2 Hz repetition rate. RF microstructure within macropulse. CW operation at 9.1 mA with 75 MHz microstructure and 122 pC/bunch. Gun routinely delivers 5 mA in pulsed and CW modes with 135 pC/microbunch. Vacuum environment: 4.0E-11 Torr, 99.9% H 2 Operated by the Southeastern Universities Research Association for the U.S. Depart. Of Energy Thomas Jefferson National Accelerator Facility FEL Courtesy C. H. Garcia and JLab FEL team

Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. of Energy M. Poelker, EIC Workshop, March 15-17, 2004 Continuing Trend Towards Higher Average Beam Current ELIC with circulator ring JLab FEL program with unpolarized beam Year Ave. Beam Current (mA) First polarized beam from GaAs photogun First low polarization, then high polarization at CEBAF Source requirements for ELIC less demanding with circulator ring. Big difference compared to past talks. Few mA’s versus >> 100 mA of highly polarized beam.

One accelerating & one decelerating pass through CEBAF ELIC Layout Ion Linac and pre - booster IR Beam Dump Snake CEBAF with Energy Recovery 3-7 GeVelectrons GeV light ions Solenoid Ion Linac and pre - booster IR Beam Dump Snake CEBAF with Energy Recovery 3-7 GeVelectrons GeV light ions Solenoid Ion Linac and pre - booster IR Beam Dump Snake CEBAF with Energy Recovery 3 -7 GeVelectrons GeV (light) ions Solenoid Electron Injector Electron Cooling (A=1-40) Operated by the Southeastern Universities Research Association for the U.S. Department Of Energy Thomas Jefferson National Accelerator Facility Electron circulator ring

Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. of Energy ELIC e-Beam Specifications Typical parameters; Ave injector gun current 2.5 mA (and then 25 mA) Micropulse bunch charge 1.6 nC Micropulse rep rate 150 MHz (and then 1.5 GHz) Macropulse rep rate ~ 2 kHz, 5 usec duration.

Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. of Energy M. Poelker, EIC Workshop, March 15-17, 2004 Need 80% polarized e-beam. Use SVT superlattice photocathode. 1% QE at 780 nm; 6.3 mA/W/%QE ~ 1 W provides 1/e operation at 2.5 mA Commercial Ti-Sapp lasers with CW rep rates to 500 MHz provide 0.5 W. Homemade lasers provide ~ 2W. Injector micropulse/macropulse time structure demands laser R&D. 25 mA operation requires more laser power and/or QE. Charge Limit? Yes, at 1.6 nC/bunch and low QE wafers. Lifetime? Probably wise to improve vacuum (more later) Gun HV ~ 500 kV to mitigate emittance growth. Must limit field emission. Gun Issues for ELIC

Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. of Energy M. Poelker, EIC Workshop, March 15-17, 2004 Gun Lifetime CEBAF enjoys good gun lifetime;  ~ 200 C charge lifetime (until QE reaches 1/e of initial value)  ~ 100,000 C/cm2 charge density lifetime (we operate with a ~ 0.5 mm dia. laser spot) Gun lifetime dominated by ion backbombardment. So it’s reasonable to assume lifetime proportional to current density. Use a large laser spot to drive ELIC gun. This keeps charge density small. Expect to enjoy the same charge density lifetime, despite higher ave. current operation, with existing vacuum technology.

Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Dept. of Energy M. Poelker, EIC Workshop, March 15-17, 2004 Use 1 cm diameter laser spot at photocathode. At 2.5 mA gun current, we deliver 9 C/hour, 216 C/week. Charge delivered until QE falls to 1/e of initial value; Need to test the scalability of charge lifetime with laser spot diameter. Measure charge lifetime versus laser spot diameter in lab. (J. Grames presentation this workshop) Gun Lifetime cont. 100,000 C/cm2 *1 Wk/216 C * 3.14(0.5 cm)^2 = 360 Wks! 36 Weeks lifetime at 25 mA. Lifetime Estimate;