Siena 2002 Siena, 24/10/2002 G. Passaleva New results from an extensive aging test on bakelite RPC G. Passaleva INFN Firenze.

Slides:



Advertisements
Similar presentations
RPC2010- Darmstadt- 9/12-Feb p.1 M. Abbrescia – University and INFN Bari New gas mixtures for Resistive Plate Chambers operated in avalanche mode.
Advertisements

Development of high rate RPCs Lei Xia Argonne National Laboratory.
Aging, High Rate and Shielding L. Lopes Lip-Coimbra.
C.Gustavino, XPC and VETO, LNGS OPERA meeting, may VETO AND XPC: Preliminary ideas Outline: Mechanical structure Gas mixture study Aging tests Glass.
Status of the LHCb RPC detector Giovanni Carboni - Roma 2 Introduction Detector requirements Ageing tests Oil vs. No-Oil Conclusions Report to LHCC - March.
Status of the LHCb RPC detector Changes with respect to Note cm strips instead of 3 cm (cost optimization) All gaps same size (standardization)
G. Carboni - Open LHCC - July 2001 Technical Design Report for the LHCb Muon System Giovanni Carboni on behalf of the Muon Group Part II: RPC Detectors,
HCAL with Resistive Plate Chambers José Repond Argonne National Laboratory Presented at the Chicago Linear Collider Workshop January 7-9, 2002.
1 May 6, 2009 C. Lu Continuously Monitoring the RPC Gas Mixture with a Gas Chromatograph C. Lu Princeton University.
RPC Update José Repond Argonne National Laboratory American Working Group On Linear Collider Calorimetry 16 September 2003 What’s new since Cornell…
1 March 27, 2007 IHEP RPC Bakelite Resistivity in-Situ Test Results and Strip Plane Considerations W. Sands, C. Lu and K. McDonald Princeton University.
New MRPC prototypes developed in Tsinghua Unversity Huangshan Chen (Tsinghua Unversity)
ATLAS RPC: Cosmic Ray Teststand at INFN Lecce G. Chiodini, M. Bianco, E. Brambilla, G. Cataldi, R. Coluccia, P. Creti, G. Fiore, R. Gerardi, E. Gorini,
CMS - PAVIA1 Engineering Design Review RPC - BAKELITE.
RPC (Resistive Plate Chamber)
2011 HV scan SF6 flow-meter accident 2011 Results comparison RPC HV efficiency scan Pigi Paolucci on behalf of RPC collaboration.
WP2: Detector development Summary G. Pugliese INFN - Politecnico of Bari.
Results from development of Glass RPCs for INO detector
Development and study of Glass Resistive Plate Chambers Satyanarayana Bheesette Roll number: Supervisors Prof Raghava Varma, IIT Bombay Prof Naba.
November 5, 2004V.Ammosov ITEP-Moscow, Russian CBM meeting 1 IHEP possible participation in CBM TOF system Vladimir Ammosov Institute for High Energy Physics.
M.Alfonsi 1, G. Bencivenni 1, W. Bonivento 2,A.Cardini 2,C. Deplano 2, P. de Simone 1, F.Murtas 1, D.Pinci 3, M. Poli-Lener 1, D. Raspino 2 and B.Saitta.
PHENIX RPC in China Li Ye Shouyang Hu Xiaomei LI China Institute of Atomic Energy
First results of an aging test of a full scale MWPC prototype for the LHCb muon system Workshop on “Aging Phenomena in Gaseous Detectors”, October 2-5.
RPC Development in Beijing and Potential for NO A Tianchi Zhao University of Washington May 16, 2005.
1 A.Di Ciaccio LHC upgrade Working Group November 2005 The ATLAS RPC trigger system  The entire stand-alone muon system has been designed to handle background.
VCI 2004Gaia Lanfranchi-LNF/INFN1 Time resolution performances and aging properties of the MWPC and RPC for the LHCb muon system Gaia Lanfranchi – INFN/LNF.
The dynamic behaviour of Resistive Plate Chambers
Tests of a Digital Hadron Calorimeter José Repond Argonne National Laboratory CALICE Collaboration Meeting March 10 – 12, 2010 University of Texas at Arlington.
Optimization of the Resistive Plate Chamber operation with a closed loop gas system at the Large Hadron Collider experiments M. Capeans, I. Glushkov, R.
RPC detection rate capability ≈ 1/ρ Float-Glass ( Ω-cm) RPC rate capability < Bakelite( Ω-cm) one. New kind of doped glass was developed.
TOF Gas System Project Overview. Content Prototype for Aging tests done for RPC’s TOF Gas System: parameters and module layouts. Special Technology: channel.
Prototypes of high rate MRPC for CBM TOF Jingbo Wang Department of Engineering Physics, Tsinghua University, Beijing, China RPC-2010-Darmstadt, Germany.
(Santiago de Compostela-Spain)
Study of UV absorption and photoelectron emission in RPC (Resistive Plate Counters) detector with an UV source Carlo Gustavino (INFN-LNGS) RPC and their.
RPCs of BESIII Muon Identifier  BESIII and muon identifier  R&D  Mass production  Installation Zhang Qingmin Advisor: Zhang Jiawen.
G. Pugliese RPC requests for GIF++ G.Pugliese, N. Zaganidis and I. Pedraza on behalf of the RPC group 1.
Gap Production for Upscope of the Endcap RPCs Sung Keun Park Korea Detector Laboratory Korea University February 5, 2010 Workshop on the Forward CMS RPC.
Andrea Di Simone Andrea Di Simone – INFN Roma2 Andrea Di Simone CERN PH/ATC and INFN-CNAF On behalf of ATLAS RPC groups: Lecce, Napoli, Protvino, Roma2.
Control of the RPC ageing effects in the ATLAS chambers at the GIF - X5 CERN irradiation facility Siena 2004 Siena, 24/05/2004 By G. Aielli on behalf of.
Report on beam test results of high-rate MRPCs Jingbo Wang Department of Engineering Physics, Tsinghua University, Beijing, China.
July 8, 2003V.Ammosov GSI, CBM meeting1 RPC TOF system for HARP experiment (Applicability for CBM) Vladimir Ammosov Institute for High Energy Physics Protvino.
Tests of RPCs (Resistive Plate Chambers) for the ARGO experiment at YBJ G. Aielli¹, P.Camarri¹, R. Cardarelli¹, M. Civardi², L. Di Stante¹, B. Liberti¹,
Slide 1Crispin Williams INFN BolognaALICE TOF The ALICE-TOF system 1. Quick overview of the TOF system that we are building 2. The Multigap Resistive Plate.
STATUS REPORT WP7 Facilities and Component Analysis for Detector R&D Activities and Status Resources and Expenditures Work plan Mar CAPEANS 3/11/08 M.C.
Results from the CMS-RPC tests at CERN Gamma Irradiation Facility Roberto Guida CMS-RPC (Bari, Beijing, Napoli, Pavia, Sofia) Seoul, October 2005.
Marcello Abbrescia RPCs for CMS during Phase II RPC rate capability M. Abbrescia, The dynamic behaviour of Resistive Plate Chambers, NIM A 533 (2004) 7–10.
Test on installed RPCs with the gas mixture. Preliminary results. Alessandro Paoloni on behalf of the OPERA RPC Group (Bologna, LNF, LNGS, Napoli, Padova,
Study of gas mixture containing SF6 for the OPERA RPCs A.Paoloni, A. Mengucci (LNF)
1 Analysis of Small RPC DHCAL Prototype Data (noise and cosmic ray) LCWA09, Albuquerque, New Mexico Friday, October 02, 2009 Qingmin Zhang HEP Division,
For 2016 RPCWorkshop 1 Charge Distribution dependency on gap thickness of CMS endcap RPC Sung Park, KODEL, Korea Univ On behalf of the CMS RPC group 1.
S. Colafranceschi - Ischia CMS RPC Italia1 CMS RPC studies at ISR Stefano Colafranceschi Laboratori Nazionali Frascati Università di Roma – La Sapienza.
Performance and Aging Studies of BaBar RPC’s Henry R. Band University of Wisconsin for the BaBar IFR-RPC group RPC 2005 VIII Workshop.
Final results from an extensive aging test on bakelite Resistive Plate Chambers Stefano de Capua University of Rome II “Tor Vergata” and INFN.
SiO x coated fiber optic sensor for gas monitoring in RPC S. Grassini 1, M. Parvis 2, M. Ishaiwi 2 1 Dip. di Scienza Applicata e Tecnologia 2 Dip. di Elettronica.
14/02/2008 Michele Bianco 1 G.Chiodini & E.Gorini ATLAS RPC certification with cosmic rays Università del Salento Facoltà di Scienze MM.FF.NN.
RPCs with Ar-CO2 mix G. Aielli; R.Cardarelli; A. Zerbini For the ATLAS ROMA2 group.
Long-term environmental effects on the ARGO-YBJ RPC array studied with the Detector Control System P. CAMARRI 1, R. CARDARELLI 1, L. PALUMMO 1, C. VIGORITO.
The 6th ACFA Workshop on Physics and Detector at Linear Collider, TIFR, Mumbai, December 15-17, Development of RPCs for INO B.Satyanarayana TIFR,
CMS – RPC GIF++ G. Pugliese on behalf of the RPC Collaboration 1.
Extreme Energy Events M. Abbrescia Marcello Abbrescia Dipartmento Interateneo di Fisica University of Bari Improving rate capability of Resistive Plate.
Dipartimento di Fisica, Università del Salento
Results achieved so far to improve the RPC rate capability
An extensive aging study of bakelite RPC
Performance of timing-RPC prototypes with relativistic heavy ions
IEEE Symposium 2003, Portland
RPC working gas (C2H2F4/i-C4H10/SF6): Simulation and measurement
CMS muon detectors and muon system performance
Performance of a Multigap RPC prototype for the LHCb Muon System
University of Rome II “Tor Vergata”
Study of timing properties of single gap high-resistive bakelite RPC
Presentation transcript:

Siena 2002 Siena, 24/10/2002 G. Passaleva New results from an extensive aging test on bakelite RPC G. Passaleva INFN Firenze

Siena 2002 Siena, 24/10/2002 G. Passaleva Extensive aging test of RPCs at GIF 1.2 RPC prototypes under study since RPC A irradiated at GIF during 2001 – Q int  0.4 C/cm 2 RPC B not irradiated,used as a reference. GIF test setup  High flux position  Low flux position

Siena 2002 Siena, 24/10/2002 G. Passaleva RPC area 50x50 cm 2 1 meter  = 9x10 9  cm Gas mixture: 95% C 2 H 2 F 4 4% I-C 4 H 10 1% SF 6 source I, HV, T, P, gas, continuously monitored and recorded during the whole test. Particle rate: 1  3 kHz/cm 2 Test setup at GIF

Siena 2002 Siena, 24/10/2002 G. Passaleva RPC under high irradiation RPCs under high-irradiation flux show peculiar characteristics 1.An almost perfect linear dependence of the current on applied voltage 2.The current saturates when the particle flux is increased 3.A strong (exponential) dependence of the current on the temperature for a fixed value of the HV

Siena 2002 Siena, 24/10/2002 G. Passaleva Principle of RPC operation qiqi q=Gq i V0V0 gas Electrodes d,S,  particle G~ ; G  1 for V 0 < V T Due to space-charge effects (especially with SF 6 ): q  V gap -V T V gap =V 0 -IR I =  q(V gap ) (  = particle flux) If  low  I small  V gap  V 0

Siena 2002 Siena, 24/10/2002 G. Passaleva High flux conditions If    we must have q  0, i.e. V gap  V T and I max =(V 0 – V T )/R Linear dependence on HV Exponential temperature dependence of I via R: More generally: Saturation with flux

Siena 2002 Siena, 24/10/2002 G. Passaleva Current saturation X obtained fitting I at different  At GIF   1/Abs 0.7 where Abs is the filter setting (Abs=1,2,5, ) (1)

Siena 2002 Siena, 24/10/2002 G. Passaleva Measurement of R  R can be measured in a non-destructive way from the slope of I-V 0 curve  Its changes can be easily monitored  Precise knowledge of X is unimportant if X is large (an estimate is sufficient) We can obtain R by fitting I vs. V 0 curve

Siena 2002 Siena, 24/10/2002 G. Passaleva Cross check: R temperature dependence Temperature dependence is easily described in our model. Exponential fit to R measurements:  =0.126  Nice agreement with measurements on the bakelite slabs:  slab  =0.12  0.01

Siena 2002 Siena, 24/10/2002 G. Passaleva Cross check: temperature corrections on RPC current Daily temperature oscillation are corrected out using the proper temperature coefficient I 20 =I exp[-0.126(  -20°)]

Siena 2002 Siena, 24/10/2002 G. Passaleva Aging tests: irradiation Q int =0.4 C/cm 2 I  by a factor of 6 Interpretation: R  by a factor of 6 because of radiation effect Measurements of R with our model: Before irr.: R=10.9 M  After irr.: R=60.1 M 

Siena 2002 Siena, 24/10/2002 G. Passaleva New R measurements: RPC A RPC A - R 20 (1999) = 2.6 M  -  20 (1999) = 1.6x10 10  cm irradiation chamber in the lab Jan 01 Chamber again at GIF for tests. Q int  0 R  exponentially ! Oct 02:   =1.6x10 12  cm Did we reach the top ? May 02

Siena 2002 Siena, 24/10/2002 G. Passaleva New R measurements: RPC B Chamber at GIF for tests. Q int  0 R  exponentially ! RPC B - R 20 (1999) = 5.2 M  -  20 (1999) = 3.2x10 10  cm May 02 Oct 02:   =1.7x10 12  cm RPC B never irradiated ! Did we reach the top ?

Siena 2002 Siena, 24/10/2002 G. Passaleva Summary 1.As expected, R increases because of irradiation 2.Surprisingly, R increases spontaneously, much more than because of irradiation 3.We also see a saturation effect in the growing of R (to be confirmed) What are the effects on the RPC rate capability ?

Siena 2002 Siena, 24/10/2002 G. Passaleva Definition of rate capability The rate capability is defined by:  >95% (trigger) HV<11000 (streamers !) plateau  400V

Siena 2002 Siena, 24/10/2002 G. Passaleva GIF test October 1999 RPC A RPC B GIF Rate  3 kHz/cm 2 R A =1.8 M  R B =3.6 M  T=23.0 °C R  2  =2.6 M  R  2  =5.2 M  R A =1.8 M  R B =3.6 M  T=23.0 °C R  2  =2.6 M  R  2  =5.2 M  Rate max > 3 kHz/cm 2

Siena 2002 Siena, 24/10/2002 G. Passaleva GIF test August 2001 Rate max  1.15 kHz/cm  600 Hz/cm 2 After 6 months of irradiation (Qint  0.4C /cm 2) R A =31.6 M  T=25.1 °C R 2  =58.3 M  R A =31.6 M  T=25.1 °C R 2  =58.3 M  RPC A

Siena 2002 Siena, 24/10/2002 G. Passaleva Latest results: GIF test July 2002 Rate max  350 Hz/cm  200 Hz/cm 2 R=102.4 M  T=24.5 °C R 2  =175.7 M  R=102.4 M  T=24.5 °C R 2  =175.7 M 

Siena 2002 Siena, 24/10/2002 G. Passaleva Conclusions 1.We have developed and applied a method to measure RPC electrode resistivity, on-line, during chamber operations, in an easy and non destructive way. 2.This method allows to monitor the resistivity as well as to correct other physical quantities (e.g. the current) for temperature effects. 3.Using this method we have studied extensively the aging effects on bakelite RPCs: R increased by 2 orders of magnitude in 3 years. Rate capability dropped from a few kHz/cm 2 to less than 150 Hz/cm 2 (  no RPC in LHCb !!!) Pure spontaneous aging is the dominant effect