Neutron Scattering Group March, 2001 A High Performance Hybrid Spectrometer for the Single Crystal Spectroscopy at the Pulsed SNS  Scientific case and.

Slides:



Advertisements
Similar presentations
Focusing monochromators/analyzers Asymmetric diffraction geometry of the monochromator Dispersive double crystal monochromator Two wavelength sandwich.
Advertisements

Spectral Resolution and Spectrometers
Spectral Resolution and Spectrometers A Brief Guide to Understanding and Obtaining the Proper Resolution of the 785 Raman System.
Proposal of high-resolution eA collider spectrometer Seigo Kato Yamagata University.
Remote sensing in meteorology
Pair Spectrometer Design Optimization Pair Spectrometer Design Optimization A. Somov, Jefferson Lab GlueX Collaboration Meeting September
Yury CHESNOKOV Crystal Collimation workshop, March 7, 2005 CALIBRATION of CMS CALORIMETERS with LHC PROTON BEAM DEFLECTED BY CRYSTAL CALIBRATION of CMS.
Hardware Progress Doug Abernathy ARCS Instrument Scientist ARCS IDT Meeting Lujan Center, LANL September 30, 2002 SNS Instrument SystemsArgonne/Oak Ridge.
ASIC3 WorkshopLandsdowne, VA May 16-18, 2006 J. Harder Page 1 Calibration Status of the Solar Irradiance Monitor (SIM) : The Present and the Future Jerald.
Photon Source and Tagger Richard Jones, University of Connecticut GlueX Detector ReviewOctober 20-22, 2004, Newport News presented by GlueX Tagged Beam.
Sample simulation. Basic Picture Complexity 1: Geometry.
HYSPEC Hybrid Spectrometer Instrument Development Team April, 2002 A High Performance Hybrid Spectrometer for the Single Crystal Studies at the Pulsed.
4-1 Chap. 7 (Optical Instruments), Chap. 8 (Optical Atomic Spectroscopy) General design of optical instruments Sources of radiation Selection of wavelength.
Review Doppler Radar (Fig. 3.1) A simplified block diagram 10/29-11/11/2013METR
Interim progress summary: ITER Imaging X-ray crystal spectrometer design Sam Davis - UKAEA Robin Barnsley - ITER.
Polarized Beams Using He-3 at the NCNR Triple-Axis Spectrometers Ross Erwin Tom Gentile Wangchun Chen Sarah McKenney.
HPS Test Run Setup Takashi Maruyama SLAC Heavy Photon Search Collaboration Meeting Thomas Jefferson National Accelerator Facility, May 26-27,
Progress on the New High Intensity Cold Neutron Spectrometer, MACS C. Broholm 1,2, T. D. Pike 1,2, P. K. Hundertmark 1,2, P. C. Brand 2, J. W. Lynn 2,
Conceptual Design: MACS is designed to maximize the efficiency for energy resolved surveys of Q-space in the sub-thermal energy range. Two innovations.
Status of the Beamline Simulation A.Somov Jefferson Lab Collaboration Meeting, May 11, 2010.
HYSPEC HYSPEC INSTRUMENT DESIGN – OUTLINE  The two “models” considered for HYSPEC – inside & outside (Mark)  A breakdown of the components of the two.
HYSPEC Recent progress and polarization analysis capabilities ORNL: B. Winn, V. Ovidiu Garlea, M. Graves- Brook, Peter Jiang, X. (Tony) Tong BNL: L. Passell,
The system of neutron optics for the diffractometer E PSILON and SKAT K.Walther A. Bulkin A.Frischbutter V. Kudryashov Ch. Scheffzük F. Schilling.
Proposal for a High Intensity Chopper Spectrometer at LANSCE Science requiring high sensitivity neutron spectroscopy Limitations of current instrumentation.
MACS –a New High Intensity Cold Neutron Spectrometer at NIST February 17, 2003Timothy D. Pike1 Developing MACS A Third Generation Cold Neutron Spectrometer.
Simulations of the double funnel construction for LET. Comparison with a single funnel The aim was to optimise the double funnel configuration to give.
Choosing the Right Neutron Spectrometer Dan Neumann NIST Center for Neutron Research
DECam Daily Flatfield Calibration DECam calibration workshop, TAMU April 20 th, 2009 Jean-Philippe Rheault, Texas A&M University.
HYSPEC 1 Instrument design, shielding/background simulations for Hyspec Vinita J. Ghosh.
NANO 225 Micro/NanoFabrication Electron Microscopes 1.
HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.
Introduction to Neutron Scattering Jason T. Haraldsen Advanced Solid State II 2/27/2007.
The HYSPEC Polarized Beam Spectrometer Barry Winn, Mark Hagen, Mark Lumsden, Melissa Graves-Brook David Anderson, Xin Tony Tong B2.5, rm G, 3:15-3:30 PM.
1 Data Acquisition What choices need to be made?.
NANO 230 Micro/Nano Characterization
Projected performance of NPDGamma and new systematics introduced by SM polarizer Christopher Crawford University of Kentucky NPDGamma Collaboration Meeting.
Polarized Neutrons in ANSTO – From LONGPOL to Pelican, Taipan, Sika, Platypus and Quake Dehong Yu and Shane Kennedy Bragg Institute, ANSTO, Australia.
MACS Concept and Project Status Making best use of CW source MACS-imizing incident flux MACS-imizing detection efficiency From concept to reality Collin.
HYSPEC HYSPEC: A High Performance Polarized Beam Hybrid Spectrometer at the SNS Beamline 14B I.Zaliznyak 1, S. Shapiro 1, L. Passell 1, V. Ghosh 1, W.
David Winogradoff Haverford College NCNR, NIST Ivan Schroder
HYSPEC IDT Polarized Beam Operation of the Hybrid Spectrometer at the pulsed Spallation Neutron Source. Outline HYSPEC: project timeline and place in the.
The NCNR Spin-Polarized Triple-Axis Spectrometer (SPINS) The SPINS instrument is located at the heart of the cold neutron guide hall of the NIST Center.
MACS –a New High Intensity Cold Neutron Spectrometer at NIST September 24, 2002Collin L. Broholm Timothy D. Pike 1 Scientific Program and Requirements.
Parameters of the new diffractometer “ARES” Aleksey E. Sokolov PNPI NRC “KI”
1 How Can We Get More Neutrons? Upgrade Paths for the EDM Geoff Greene University of Tennessee /Oak Ridge National Laboratory Oct 2006.
ESS - SANS Instrumentation pulsed source SANS, using a wide range of wavelengths, uses more of the available flux than a continuous source. For same time.
Photon Source and Tagger Richard Jones, University of Connecticut GlueX Detector ReviewOctober 20-22, 2004, Newport News presented by GlueX Tagged Beam.
Conceptual design and performance of high throughput cold spectrometer : MACS Why MACS Layout and key elements Performance Data collection Scientific program.
Past and Future Insights from Neutron Scattering Collin Broholm * Johns Hopkins University and NIST Center for Neutron Research  Virtues and Limitations.
Neutron Scattering Group February, 2001 A High Performance Instrument for the Single Crystal Spectroscopy at the Pulsed SNS. n What is the spectrometer.
MCNSI meeting, February 2006 Contents: People –V. Ryukhtin left for part time only Multichannel focusing benders – continuation –resolution functions.
NMI3 meeting, ISIS, September 26-29, 2005 Contents: Overview of new capabilities of the RESTRAX software Numerical optimizations of TAS parameters Virtual.
A New High Intensity Cold Neutron Spectrometer at NIST J. A. Rodriguez 1,3, P. Brand 3, C. Broholm 2,3, J.C. Cook 3, Z. Huang 3, P. Hundertmark 3, J. Lynn.
1.1 What’s electromagnetic radiation
CAPABILITIES Desire to measure lattice and spin dynamics in small single crystals:  Need high flux at sample position.  Low background Science Needs:
An electron/positron energy monitor based on synchrotron radiation. I.Meshkov, T. Mamedov, E. Syresin, An electron/positron energy monitor based on synchrotron.
HYSPEC IDT Polarized Beam Mode for the Hybrid Spectrometer (HYSPEC) at the Spallation Neutron Source. Outline BNL’s HYSPEC project and its place in the.
Initial Results from the Scintillator Fast Lost Ion Probe D. Darrow NSTX Physics Meeting February 28, 2005.
HYSPEC IDT Introduction to HYSPEC: Overview of the Conceptual Design and Top Level Specifications. Outline Overview of the HYSPEC layout and principal.
HYSPEC IDT Options for polarization analysis with 3 He for the Hybrid Spectrometer (HYSPEC) L. Passell, V.J. Ghosh, I. Zaliznyak, S. Shapiro, W. Leonhardt,
HYSPEC IDT HYSPEC: Our Instrument at the Spallation Neutron Source. Outline Spallation Neutron Source (SNS) and the BNL Overview of the SNS instrument.
Moving the NPDGamma Experiment to the SNS FnPB Christopher Crawford University of Kentucky overview of NPDGamma transition to the SNS expected.
HYSPEC IDT Polarized Beam Mode for the Hybrid Spectrometer (HYSPEC) at the Spallation Neutron Source. Outline Polarization analysis and the HYSPEC place.
Werner Schweika, Nicolo Violini, Earl Babcock Michael Meissner Andreas Houben, Philipp Jacobs Gunnar Svennson, Xiaodong Zou, Niklas Hedin, Mats Johnsson,
October, 2001 Hybrid Spectrometer for Single Crystal Studies at the Pulsed SNS: an update. n Principal features of the proposed hybrid spectrometer. n.
New optics for X’Pert PRO
NANO 230 Micro/NanoFabrication
MIRACLES budget: Summary of the 3 configurations
Scope Setting Meeting MIRACLES
Computed Tomography (C.T)
Presentation transcript:

Neutron Scattering Group March, 2001 A High Performance Hybrid Spectrometer for the Single Crystal Spectroscopy at the Pulsed SNS  Scientific case and design objectives for the proposed hybrid spectrometer for the SNS  General layout of the proposed spectrometer and its place in the SNS instrument suite  Comparison of different spectrometer concepts and evolution of our thinking  Preliminary analysis of the instrument performance Igor Zaliznyak Laurence Passell Outline

Neutron Scattering Group Scientific case for a proposed instrument for the SNS  Coherent collective excitations in single crystals: lattice dynamics (phonons) spin dynamics (magnons, critical scattering)  Structure and dynamics of partially ordered and glassy states spin glasses charge glasses correlated amorphous phases  Study of the microscopic physical properties of samples in a variety of extreme environments: magnetic field pressure temperature  Characterization of spin-dependent cross-sections by means of polarization analysis Neutron spectrometer for studies of the coherent low-energy states in single crystals.

Neutron Scattering Group What are the typical samples we want to study? CuGeO 3 sample used by M. Arai group for detailed measurement of the excitation dispersion on MAPS in 2000 CuGeO 3 sample used by L.-P. Regnault for the original measurement in 1993

Neutron Scattering Group Benchmark requirements for a single crystal neutron spectrometer Transmission of both primary (monochromator) and secondary (analyzer) spectrometers should be close to 1 within the resolution acceptance range, and vary smoothly over a substantial energy interval, typically from 2.5 meV to 60 meV.  Transmission of both primary (monochromator) and secondary (analyzer) spectrometers should be close to 1 within the resolution acceptance range, and vary smoothly over a substantial energy interval, typically from 2.5 meV to 60 meV.  Both spectral (energy resolution) and angular (~ wavevector resolution) acceptances of the monochromator and analyzer should be flexible and easily adjustable, typical resolutions are 1% to 5%.  Scattering volume seen by a detector should be well defined and easily adjustable depending on the sample size to minimize the background.  Efficient use of the large incident neutron beam by focusing it on the sample is very important, and should be previewed.

Neutron Scattering Group What are our main design goals? qUse most of the monochromatic neutron intensity produced by the source, while providing the highest possible signal-to- background ratio in the detector at a good to moderate energy and wavevector resolution  Use the pulsed time structure of the neutron beam at the SNS  Avoid the direct view of the moderator and the source by the sample  Make solid angle accepted by the secondary spectrometer as large as necessary  Make range of the scattering angles accessible to the secondary spectrometer as large as possible  Preview an easy setup of the polarized beam option  Trade-off of the resolution for intensity should not degrade the instrument performance

Neutron Scattering Group How does the instrument we propose fit SNS inelastic instruments suite? High resolution and low energy transfer  eV Multichopper Spectrometer E = meV E = meV Q = Q = Å -1 High energy transfer meV Fermi Chopper Spectrometer E = meV E = meV Q = 0.1 – 22 Q = 0.1 – 22 Å -1 High intensity at moderate resolution and medium energy transfer + polarized beam Crystal Monochromator Hybrid Spectrometer E = meV E = meV Q = 0.1 – 8 Q = 0.1 – 8 Å -1

Neutron Scattering Group Schematic layout of the proposed Rotating Crystal Time-of-Flight Spectrometer

Neutron Scattering Group How does the instrument we propose fit SNS floor layout? Needs rather short, 15 to 25 m primary flight path, but large, ~7-8 m radius floor area for the moving analyser bank and the sample table.  Use the space following a shorter instrument?  Occupy a “tangential” position with no other instruments on one side? ?

Neutron Scattering Group Evolution of our concept: from multi-chopper TOF to chopper-less hybrid spectrometer Optimized layout of the direct geometry hybrid spectrometer with vertically focused crystal monochromator: expected gain from vertically focusing the beam >~ 2 Optimized layout of the direct geometry disc chopper spectrometer: curved guide loss ~6%, tapered section gain <1.4 We choose to optimize the instrument performance at E i = 14.7 meV

Neutron Scattering Group Pro’s and Con’s of a Fermi Chopper 1 Advantages of a Fermi chopper short burst times can be achieved with wide beams works for very energetic neutrons beam height is not limited 1 Disadvantages of a Fermi chopper is a rotating collimator with curved slots: limits the beam horizontal divergence, does not take full advantage of the guide short burst times require tight collimation, i.e. reduced transmission and angular acceptance is optimized for a fixed set of incident energies, changing energy or resolution requires changing the rotor finite transmission away from the nominal angular position (especially at 180°) may lead to background and non-trivial beam contamination does not focus neutron beam on the sample

Neutron Scattering Group Pro’s and Con’s of a Disk Chopper 1 Advantages of a disc chopper rotation rate is not correlated with neutron energy, resolution can be semi-continuously varied energy can be changed without impacting on transmission 1 Disadvantages of a disc chopper small burst width cannot be achieved with wide beams because tensile strength limits maximum rotation rate transmission reduces when time for neutrons to traverse the disk becomes comparable with the slot open time (at lower neutron energies) order contamination may occur when multiple slot discs are used beam height is limited does not focus neutron beam on the sample

Neutron Scattering Group Pro’s and Con’s of a Crystal Monochromator 1 Advantages of a crystal monochromator beam may be compressed on the sample using focusing Bragg optics, beam height is not limited sample and its environment are exposed only to a reflected monochromatic beam: reduced background works for wide beams resolution is easily adjusted by putting the collimators (Heusler) may provide a polarized beam for energies up to ~60 meV 1 Disadvantages of a crystal monochromator lower than one and energy-dependent reflectivity of the crystal, is not well-suited for providing high-energy incident neutrons energy and wavevector resolutions are coupled and depend on the instrument position sample table and secondary spectrometer need to be moved when beam energy is changed

Neutron Scattering Group What’s Good About Rotating Crystal? 1 Advantages of a rotating crystal monochromator short burst times can be achieved with wide beams without impacting on either transmission or collimation burst time decrease with decreasing neutron wavelength rotation rates are well below the tensile strength limit takes full advantage of the horizontal divergence introduced by the supermirror-coated guide no impact on vertical focusing possibility of time focusing (or defocusing) by changing the sense of rotation 1 Disadvantages of a rotating crystal monochromator introduces some Doppler broadening (but it decreases as the neutron wavelength increases) ? Defines the time structure of the neutron pulse at the sample: no chopper is necessary

Neutron Scattering Group Technical case for the rotating crystal monochromator A PG(002) crystal array 23 cm wide is needed to reflect a 4 cm wide beam of 60 meV neutrons  We assume a composite crystal monochromator, mounted on a 24 cm wide segmented vertically focusing device (GMI type), made of a high tensile strength Al alloy  At a rotation rate of 240 Hz the peripheral velocity of the frame is 181 m/sec, well below the maximum peripheral velocity (500 m/s) for high tensile strength Al alloys  At a rotation rate of 240 Hz the crystal velocity at the periphery of the spot illuminated by a 4 cm wide guide is about 5.1% of the velocity of a reflected neutron. For E i > 14.7 meV this corresponds to a Doppler broadening of the incident energy distribution of less than 3.6%.  Narrowing the beam reduces the Doppler broadening, a phased disc chopper upstream could be used for Doppler focusing

Neutron Scattering Group Performance of the rotating crystal monochromator Crystal rotation rate (Hz)Burst FWHM (  s)  t/t  E/E Ei=5.0 meV (  0 = 2.4°) % % % % Ei=14.7 meV (  0 = 1.4°) % % % % Ei=60.0 meV (  0 = 0.69°) % % % % PG(002) rotating crystal viewing the m=3 supermirror guide PG(002) rotating crystal viewing the m=3 supermirror guide Crystal mosaic 1.2°, downstream angular acceptance  1 = 0.66° Crystal mosaic 1.2°, downstream angular acceptance  1 = 0.66° Secondary flight path 4.0 m Secondary flight path 4.0 m

Neutron Scattering Group Secondary flight path and analyzer performance L SD  t/t  E/E E f =5.0 meV 4 m % 5 m % E f =14.7 meV 4 m % 5 m % Ef=60.0 meV 4 m % 5 m % Analyzer resolution for the length of the secondary flight path L SD =4 m and 5 m and for the t=40  s burst width at the sample (FWHM) Uncertainty of the flight time in the analyzer gives largest contribution to the energy resolution. k f /k i =0.5 k f /k i =1.0 60° - 90° coverage of the scattering angle by the detector array gives simultaneous access to large enough interval in Q for 0.5<k i /k f <1 Moving the analyzer is cost-effective!

Neutron Scattering Group Choice of the moderator “Benchmark” the instrument performance at E i = 15 meV E i = 10 meVE i = 20 meV coupled H 2 decoupled H 2 coupled H 2 decoupled H 2 tt Intensity Figure of merit is the integral flux within  s time window, defined by the length of the secondary flight-path Coupled supercritical H 2 moderator

Neutron Scattering Group Performance of the guide. Impact of the guide curvature (relative to the similar straight guide) Impact of the guide coating (relative to 3  c supermirror guide)  L = 20 m curved 3  c supermirror guide at a reasonable offset of 8 cm ~ 2 times the width of the guide provides ~75% transmission at 60 meV  Shorter (L = 15 m?) but narrower (3 cm?) guide may still be O.K.

Neutron Scattering Group Punchline: technical features of a proposed direct geometry hybrid instrument for the SNS  Spectrometer is optimized for energy resolution dE/E~ wavevector resolution dQ/Q~  High flexibility continuous variation of the incident energy from 2.5 to 60 meV with no higher-order contamination full range of energy transfers available at each Q easily and broadly variable energy and Q resolution possibility of time focusing/defocusing easily adaptable for polarization analysis  Very low background sample is 1.8 m away from the direct beam scattering volume is well defined by collimators  High sensitivity to small scattering cross-sections (signal to BG ratio)  Can be operated at small scattering angles (near the forward direction)  User friendly: allows for easy on-line data monitoring and analysis and experiment planning Efficient vertical focusing provides reasonable data collection rates even for very small samples !