1 Update: TF Outer Ring and Clevis Design TF Outer Ring – Implemented recommendations from P. Rogoff. Modified Bolted Joint. Modified weldment to reduce moments. Clevis Redesigned – Remove/Replace Existing Clevis. – Attach New Clevis to VV via welded studs. – Reduce Clevis offset from VV. Springs removed/replaced with solid rods.

2 Dimension Increased Joint configuration modified. VV-Clevis Attachment Plate New Clevis Studs Rods Spherical Rods Ends Joint Subassembly: Prefabricated, oversized, field fit and welded. Joint Subassembly

3 Distance to vessel surface 1.70 inch Distance to vessel surface tangent 1.43 inch Tabs angled to accommodate rod end connection. Clearance for stud weld.

4 Weldment Angles modified to reduce moments about the TF Outer Leg centerline.

5 Update: Upper Lid Design Upper Lid to SS Bolt Plate: – Friction joint carries shear. SS Bolt Plate to G10 Crown: – Shoulder bolts carry shear. Lid to Umbrella Attachment Design is ongoing.

6 Upper Lid Generous clearance hole through lid for bolts. Bolt Plate G10 Crown High Tolerance Fit for Shoulder Bolts Upper Lid/Bolt Plate Interface: Friction joint carries the shear. Bolt Plate/Crown Interface: Shoulder bolts carry shear. SS insert for shoulder bolt attachment. Submodeling with Ansys Workbench (AWB)

7 Update: VV midsection Stress Ansys Workbench Submodel created. – Scenario 79, No Disruption Load. – Various reinforcements applied. Able to reduce stress by 15 ksi. Believe < 2/3 yield is achievable. Pending final disruption load from T. Willard. Pending new global model/ submodel FEA with reinforcement to confirm acceptable stress.

8 Submodeling with Ansys Workbench (AWB)

9 Submodel for VV midsection: Scenario 79, No disruption load. Units: psi

10 Update: Umbrella Leg Reinforcements Various reinforcements analyzed. Achieved acceptable stress results. Weld distortion is a concern, must minimize it. Need to analyze configuration more suitable for installation. Weld testing to quantify weld distortion is planned.

11 Baseline reinforcement configuration from global model. Single sided reinforcement: 1 x 3 inch Units: psi

12 Design with Acceptable Stress. Double sided reinforcement at 1.5 inch thick. Units: psi

13 Design for plug welding. Needs to be analyzed.


Download ppt "Update: TF Outer Ring and Clevis Design TF Outer Ring – Implemented recommendations from P. Rogoff. Modified Bolted Joint. Modified weldment to reduce."