Presentation is loading. Please wait.

Presentation is loading. Please wait.

LAWCA for Air Shower Detection at High Altitude IHEP, Beijing Zhiguo Yao VCI, 11-15/02/2013.

Similar presentations


Presentation on theme: "LAWCA for Air Shower Detection at High Altitude IHEP, Beijing Zhiguo Yao VCI, 11-15/02/2013."— Presentation transcript:

1 LAWCA for Air Shower Detection at High Altitude IHEP, Beijing Zhiguo Yao VCI, 11-15/02/2013

2 LAWCA - Large Area Water Cherenkov Array

3 Physics Goals  VHE gamma sky survey (100 GeV-30 TeV): Extragalactic sources & flares; VHE emission from Gamma Ray Bursts; Galactic sources; Diffused Gamma rays.  Cosmic Ray physics (1 TeV-10 PeV): Anisotropy of VHE cosmic rays; Cosmic electrons / positrons; Cosmic ray spectrum; Hadronic interaction models.  Miscellaneous: Gamma rays from dark matter; Sun storm & IMF.

4 VHE  -astronomy: Two Techniques  IACTs: H.E.S.S., VERITAS, MAGIC, … good angular resolution (~0.1  ); fair background rejection power; short duty cycle (~10%); narrow FOV (<5  ); Low energy threshold (~100 GeV);  Mainly focused on deep observation.  Ground particle array: AS , ARGO-YBJ, Milagro, …  not-so-good angular resolution (~0.5  );  poor background rejection power (but much elaborated in water Cherenkov);  full duty cycle (>95% , ~10  IACT);  Wide FOV ( >2/3  , ~150  IACT);  High energy threshold  improved by construction at high altitude (~1 TeV);  Good at sky survey, extended sources and flares.

5 Instrumentation History 2007 1980Whipple 0.2 Crab Crab detected! VERITAS 0.008 Crab ARGO-YBJ 0.6 Crab Tibet-AS  1.5 Crab Milagro 0.9 Crab 2012 2015 HAWC 0.06 Crab LAWCA 0.06 Crab 2004 H.E.S.S. 0.008 Crab MAGIC 0.02 Crab 2009 2001 1989 CTA 0.001 Crab LHAASO-WCDA 0.01 Crab Usually IACT is 10  better in sensitivity. 143 Sources observed 6 Sources 2017? HEGRA, CANGAROO, CAT … 0.04 Crab 10 years delay!

6 Water Cherenkov for Air Showers  Developed by Milagro, Auger, IceTop, etc.  to detect shower secondary particles: electrons/positions; muons; gammas: ~10x more, a benefit of water Cherenkov.  What are actually measured: energy flux in the water.  VHE: Two kinds of layouts: pool / tank.

7 “Sub-core” of Hadronic Showers Proton Gamma  Brightest “sub-core”: signal of the brightest PMT outside the shower core region (e.g., 45 m); mainly caused by muon (mean PE = 20, fluctuating with a long tail).  “Compactness” ( invented by Milagro):  nPMT/cxPE; proton: small; gamma: big.  “Compactness” can be employed to reject cosmic ray background efficiently

8 Detector Layout of LAWCA  An L-shape water pool: 4300 m a.s.l. North-East of ARGO-YBJ hall; 23,000 m 2 ; 4.5 m depth; 916 cells, with an 8” PMT in each cell; Cells are partitioned with black curtains. Original idea is credited to Milagro/HAWC.

9 Angular Resolution & Background Rejection  Good angular resolution: Optimized bin size: 0.85  @ 1 TeV; 0.45  @ 5 TeV.  Fair background rejection power: Q-factor: 3 @ 1 TeV; 14 @ 5 TeV.

10 Effective Area & Sensitivity  Effective area: 500 m 2 @ 100 GeV; 30,000 m 2 @ 1 TeV; 60,000 m 2 @ 5 TeV.  Sensitivity per year: 0.1 CRAB @ 1 TeV; 0.06 CRAB @ 5 TeV 。 ~10x better than ARGO-YBJ. 4 个 ¼ 阵列

11 Sensitivity to Flares  Minimum requirements: 30 events; 5 s.d.  Mainly limited by statistics. DurationSensitivity (Crab) 1 year0.06 30 days0.2 10 days0.4 3 days1 1 day2 3 hours4 2 hours5 1 hour10 3 days’ flare

12  Requirements: water-proof: loss <1/1000 volume/day; light-proof: luminous flux (300-650 nm) <100k photons/m 2 /s; tolerance to snow, rain, wind, dust, earth-quake; anti-icing; clean water compatible; light roof and top materials. Engineering of Water Pool

13 Water Purifying & Circulation  Purifying: Absorption length >30 m @ 400 nm;  Water in pool: Absorption length >20 m @ 400 nm; Uniformity: >85%.  Circulation speed: 30 days per pool volume.

14 LAWCA PMT8”/9” Input polarityPositive Single rate50 kHz Charge dynamic range 1-4000 p.e. Charge resolution 50% @ 1 p.e. 5% @ 4000 p.e. Discriminator threshold 0.25 p.e. Time range0-2000 ns Time resolution 0.5 ns Multi-hit separation 100 ns Channels3600 Cable length30 m PMT / Electronics Specifications  Single counting rate is very high: robust DAQ system;  Single PE, large dynamic range: low noise, dynodes readout;  Time resolution: essential for shower direction measurement.

15 Trigger Scheme  Cluster-based;  Neighboring clusters are half-overlapped;  Pattern: Multiplicity during 250 ns of any cluster  12; Noise trigger <1 kHz.  Besides a hardware solution, a software-based trigger mechanism is also proposed. Noise trigger

16 Trigger Rate & Data Volume  Trigger rate: ~17 kHz.  Data volume after trigger: 240 Mbps = 1 PB/year.  DAQ data volume (input, soft trigger): 4.6 Gbps = 18 PB/year. Huge amount of data: an online- reconstruction solution is under investigation. Trigger rate Data volume

17 PMT Readout  Tapered voltage divider circuit;  A specialized decoupling circuit to reduce the effect of charge piled-up;  Two dynode outputs set for SPE resolution and dynamic range;  Dynamic range 1-4000 PE can be achieved with a linearity level 5%.

18 Electronics DY10 DY8  Charge: analog shaping, digital peak detecting;  Timing: pulse front discrimination;  9 PMTs share 1 FEE board;  FEEs are synchronized with central station via White Rabbit protocol;  Hit signals are transferred to the central DAQ system via TCP/IP network, shared with WR;  DAQ: based on Atlas TDAQ software framework (soft trigger compatible).

19 Charge Calibration: Low Range  Method: single rate ~50 kHz; SPE signal dominated; Including PMT Gain + cable + pre-amp + electronics low range;  Precision: 2% per 30 seconds; Real time (hardware trigger): 2% per 30 minutes. Temperature effect: PMT + cable Variation over a month Fitted with a convolution of power law  Poisson  Gaussian + SPE noise

20 Charge Calibration: High Range  Method: muon peak ~10 Hz; muons hitting the photo-cathode; PMT gain + QE + CE + cable + pre-amp + electronics high range.  Precision: 2% per 30 minutes; Real time (hardware trigger): 2% per day. Gaussian fitting after a power law of charge is multiplied. Variation over a month Temperature effect: PMT + cable

21 Time Calibration  Cluster-based, cross- calibrated: 2 fibers per PMT (naming: short & long); 2 LEDs per cluster, lightened in turn; 2-4 fibers are crossed among neighboring clusters; Frequency of LED pulsing: 5-10 Hz.  Requirements: Time offset measurement: ~0.1 ns.

22 Time Calibration: Test Results Two fibers on a PMT Two fibers on 2 PMTs Short fibers of 2 PMTs:  = 0.07 ns. Long fibers of 2 PMTs:  = 0.12 ns. Distribution of mean offset, 3 months. Mean value: 10 minutes @ 5 Hz. Distribution of mean offset, 3 months. Mean value: 10 minutes @ 5 Hz. unit: 1/5.6 ns Distribution of single measurements, 5 minutes @ 1 kHz, different thresholds.

23 Prototype Detector (2009-2010) Single rate: 16 kHz  30-50 kHz (4300 m a.s.l.) Single rate: 16 kHz  30-50 kHz (4300 m a.s.l.)  -peak is first observed. 2 layers of 1 m  1 m Scintillators 1 layer of 1 m  1 m Scintillator 5 m 7 m

24 Engineering Array (2010-now) 9 cells, effective area 225 m 2, 1% scale of LAWCA.

25 Installation 2011/03: dry run 2011/07: wet run >10 TB test and physics data obtained so far. 2011/03: dry run 2011/07: wet run >10 TB test and physics data obtained so far.

26 Event Reconstruction and Coincidence with ARGO-YBJ

27 Support & Schedule  Provisional support from IHEP-Beijing is available: ~2 M$; Land preparation is going to start in 04/2013; Preparation for production has started, including PMTs, electronics, detector installation facilities, DAQ, data storage, …  Full support from NSFC is to be decided in 06/2013: ~10 M$; Pool construction will then start soon and is to be completed in 10/2013; Detector installation is to be completed in 07/2014; Physics run may start in 10/2014.

28 Summary  A new VHE air shower detection instrument “LAWCA” is proposed to be built at YBJ in 2 years.  Similar to HAWC, it employs water Cherenkov techniques, aimed mainly at a full sky survey for new gamma ray sources;  The detector has been designed and partially tested with the prototype and the engineering array.


Download ppt "LAWCA for Air Shower Detection at High Altitude IHEP, Beijing Zhiguo Yao VCI, 11-15/02/2013."