Presentation is loading. Please wait.

Presentation is loading. Please wait.

References 1.Schnider TW et al, Anesthesiology 1998;88:1170-82. 2.Minto CF et al, Anesthesiology 2003;99:324-33. 3.Smith WD et al, Stat Med 1996;15:1199-215.

Similar presentations


Presentation on theme: "References 1.Schnider TW et al, Anesthesiology 1998;88:1170-82. 2.Minto CF et al, Anesthesiology 2003;99:324-33. 3.Smith WD et al, Stat Med 1996;15:1199-215."— Presentation transcript:

1 References 1.Schnider TW et al, Anesthesiology 1998;88:1170-82. 2.Minto CF et al, Anesthesiology 2003;99:324-33. 3.Smith WD et al, Stat Med 1996;15:1199-215. Aim of the study This study compares two monitors of hypnotic drug effect (Index of Consciousness (IOC) and Bispectral Index (BIS)) in their ability to detect effect-site concentrations of propofol during recovery of anesthesia (Pharmacological validation). An optimal measure of hypnotic drug effect for detecting deep levels of anesthesia must have a monotonous correlation between the measure and the Burst Suppression Ratio (BSR), which is a classic EEG finding during excessive anesthesia. Methods Ethical committee approval. 15 ASA I and II patients were included (Written informed consent). BIS XP monitor (Aspect Medical Systems) and IOC (version 1.2)(Aircraft Medical) monitor simultaneously attached to patient. BIS XP sensor (Aspect Medical) and three IOC, Blue Sensors N (Ambu, Ballerup, Denmark) were attached according to manufacturers guidelines. Propofol 1% (AstraZeneca) was administered at 300ml/h with RUGLOOPII (Demed) until maximal burst suppression ratio (BSR) was found on EEG. RUGLOOPII calculates the time-synchronized Ce PROP, using the Schnider model, with a fixed time to peak effect of 1.6 min. (1,2) Measurement started when propofol was stopped. Repeated name calling every 15 seconds, until return of consciousness. All data was extracted in 5 seconds intervals. Prediction probability (P K ) was calculated for both BIS and IOC as a measure of accuracy for detecting change in Ce PROP during recovery. (3) Statistical significance was tested by an unpaired t-test (p<0.05). We used Curve-Expert (Microsoft) to calculate the Pearson correlation coefficient (R) on a scatterplot that depicts BSR versus BIS or IOC. Discussion Recovery from anesthesia is a different process compared to induction. The accuracy of IOC to detect Ce PROP during recovery appears lower compared to BIS. This is probably due to a higher vulnerability of IOC for artefacts compared to BIS. Also, during a progressive decreasing Ce PROP the IOC has a higher inter- and intra-individual variability compared to BIS (Figure 1 and 2). We found a monotonous linear correlation of IOC with BSR, which indicates a better descriptive capacity for deep anesthesia compared to BIS. IOC might benefit from an improved artefact rejection algorithm to decrease populationvariability. Such a new algorithm is currently being implemented in a new version of IOC (v14.16) (= Aircraft Medical). Nonmem modelling for in depth exploration of the methodology for comparing different depth of anesthesia monitors is being performed. Results Demographic data Mean age years (SD) Mean height cm (SD) Mean weight kg (SD) Gender M/F 50 (15)167 (9)72 (14)5/10 P K (SD) Pearson (R) BIS0.84 (0.05)0.85 IOC0.75 (0.15)0.96 No data are excluded from analysis, missing data for IOC and BIS are extrapolated from last adequately measured datapoints. Demographic data are shown in Table 1. Individual BIS and IOC are shown in respectively Fig. 1 and 2 versus Ce PROP. The respective P K ’s for BIS and IOC are shown in Table 2. The mean P K ’s for BIS and IOC were statistically different (p=0.038)(p<0.05) BIS only has a linear correlation with BSR once BSR exceeds 40 (Fig 3), IOC correlates linearly with BSR over a wider range (Fig. 4). Pearson R is shown in Table 2. Table 1 Table 2 Fig. 1Fig. 2 Fig. 3 Fig. 4 Comparing Index of Consciousness and Bispectral Index during Propofol Recovery Preliminary results Tim Mels MD * ; Barbara Wyler * ; Jean-Pierre Kalala MD, PhD # ; Michel Struys MD,PhD *$ ; Hugo Vereecke MD,PhD *. * Department of Anesthesia, Ghent University Hospital, Belgium; # Department of Neurosurgery, Ghent University Hospital, Belgium; $ Department of Anesthesia, University Hospital Groningen, The Netherlands Conclusions: During recovery of propofol, in an artefact rich dataset, IOC predicts Ce prop poorly compared to BIS. However, IOC discriminates better at deep levels of anesthesia. IOC might benefit from an improved artefact rejection algorithm. B S R


Download ppt "References 1.Schnider TW et al, Anesthesiology 1998;88:1170-82. 2.Minto CF et al, Anesthesiology 2003;99:324-33. 3.Smith WD et al, Stat Med 1996;15:1199-215."

Similar presentations


Ads by Google