Final Presentation April 20, 2010. Team Members Read Caver Hardware Design Microcontrollers Wireless Communication Technical Documentation Steven Price.

Similar presentations


Presentation on theme: "Final Presentation April 20, 2010. Team Members Read Caver Hardware Design Microcontrollers Wireless Communication Technical Documentation Steven Price."— Presentation transcript:

1 Final Presentation April 20, 2010

2 Team Members Read Caver Hardware Design Microcontrollers Wireless Communication Technical Documentation Steven Price Software Development LCD Interfacing Energy Metering Hardware Implementation James Evans Software Design Hardware Implementation LCD Interfacing Website Maintenance Albert Shannon Hardware Implementation Energy Metering Microcontrollers GUI Design Technical Documentation

3 Overview  Introduction Problems Statement Solution  Constraints Technical Practical  Prototype Design  Subsystem Testing  System Testing  Design II Goals

4 Introduction  SmartStat is a wireless thermostat with energy computation abilities  Used in both residential and commercial settings  Sets temperature for heat/AC to run, provides power monitoring capabilities  Thermostat module communicates wirelessly with 2 power consumption modules

5 NASA Sponsorship  Team SmartStat is sponsored by NASA. The team investigated the application of wireless technologies for sensor communication. Specifically, the IEEE 802.15.4 Standard for wireless communication was implemented. ○ Emphasis on low power, low speed wireless communications. The network can also be monitored via Ethernet.

6 Problem  Currently, there is no practical way to monitor the power consumption of specific high powered systems such as AC/heating units

7 Solution  Use low power wireless technology  Send power consumption information to control unit (thermostat)  Send information to RJ45 port

8 Technical Design Constraints ConstraintDescription Temperature Reading Range and Accuracy SmartStat must be able to read temperatures in the range of 50°F to 100°F, with an accuracy of 98% in the comfort range of 65°F to 75°F Energy Reading Range and Accuracy The energy monitoring modules must measure a voltage of 240Vac, maximum current of 60A, with an accuracy of 98%. Supply VoltageThe control unit must use 24Vac for supply voltage. Energy monitoring modules must use 120Vac for supply voltage. Ethernet InterfacingA RJ45 module must be used to allow for energy monitoring via an Ethernet connection. Transmission Distance The wireless modules must have a range equal to or greater than 500ft (unobstructed line-of-sight).

9 Practical Constraints  SmartStat must be compatible with the different types of HVAC systems. [1] Conventional [2] Water and ground source heat exchangers [3] Air source heat exchanger

10 Health and Safety  The control module must not allow the user to come into contact with hazardous voltages; energy monitoring modules must be sealed. [5] [4]

11 Prototyping Design Thermostat Power Monitor (air handler) Power Monitor (compressor) Ethernet (RJ45)

12 Thermostat – Main Unit

13 Energy Monitoring Modules

14 RJ45 Module

15 Subsystem Testing  Main unit Basic thermostat controls Synapse wireless module communication ○ Energy data (covered in system test) ○ Number of wireless nodes connected (covered in system test)  Energy Monitoring Modules Energy metering Synapse wireless communication  RJ-45 Module Lantronix module and GUI Synapse wireless communication  Synapse Wireless Modules  Power Supplies

16 Main Unit Basic Thermostat Controls Four LEDs to the right of breadboard represent the EM heat, Valve, Compressor, and blower controls of the HVAC system, respectively

17 Design Constraint – Satisfied Range of 50°F to 100°F, with an accuracy of 98% in the comfort range of 65°F to 75°F

18 Energy Monitoring Modules 100W Bulb Measured (ms)Calculated (ms) % Error 4545.31 -0.68889 4645.31 1.5 40W Bulb Measured (ms)Calculated (ms) % Error 116114.65 1.19469 113114.65 -1.42241 % Error Calculations Design Constraint – Satisfied Energy Metering with 98% Accuracy Output Pulses from ADE5577 Energy Metering IC (prior to calibration)

19 Lantronix Module and GUI Serial communication from a TCP/IP socket to serial pin of Lantronix module Graphical User Interface used to communicate with Lantronix XPort module via TCP/IP socket

20 Wireless to Ethernet Design Constrain – Satisfied A RJ45 module must be used to allow for energy monitoring via an Ethernet connection Synapse Module to XPort communication

21 Synapse Modules Design Constraint – Satisfied The wireless modules must have a range equal to or greater than 500ft (unobstructed line-of-sight).

22 Power Supplies Voltage in (AC)Voltage out (DC)5V rail3.3V rail Module 1113.711.414.973.28 Module 2113.811.294.963.28 Each of the energy monitoring modules must operate from 120Vac, and require two voltage rails, 3.3Vdc and 5Vdc. Design Constrain – Satisfied

23 System Testing

24 Wireless energy data received and displayed Wireless node count (if !=2), some nodes are missing

25 Fulfilled Design Constraints ConstraintSatisfied Temperature Reading Range and AccuracyYes Energy Reading Range and Accuracy Yes Supply VoltageYes Ethernet InterfacingYes Transmission DistanceYes

26 Design II Goals  PCB Design  Enclosures Wall-mountable main unit Sealed energy monitoring modules  Increase the amount of displayed energy information Decimal representation of consumed energy Cost of used energy

27 References [1] “Why Choose Us,” Broward Factor Service. [Online] Available: http://www.browardfactory.com/why-choose-us.htm [Accessed: Feb. 22, 2010].http://www.browardfactory.com/why-choose-us.htm [2] “You Can Save 80% per month on Your Electric Bill,” Energy Trio. [Online] Available: http://energytrio.com/energytrio.html [Accessed: Feb. 22, 2010].http://energytrio.com/energytrio.html [3] “Air Handlers,” Amana. [Online] Available: http://www.amana-hac.com/Home/Products/AirHandlers/tabid/292/Default.aspx [Accessed: Feb. 22, 2010].http://www.amana-hac.com/Home/Products/AirHandlers/tabid/292/Default.aspx [4] “Danger High Voltage,” Speedysigns. [Online] Available: http://www.speedysigns.com/images/osha/large/DANGER50.gif[Accessed: Feb. 22, 2010]. http://www.speedysigns.com/images/osha/large/DANGER50.gif [5] “Sign High Voltage clip art,” Clker.com. [Online] Available: http://www.clker.com/clipart-9328.html [Accessed: Feb. 22, 2010].http://www.clker.com/clipart-9328.html

28 Questions?