Secondary Ion Mass Spectrometry A look at SIMS and Surface Analysis.

Similar presentations


Presentation on theme: "Secondary Ion Mass Spectrometry A look at SIMS and Surface Analysis."— Presentation transcript:

1 Secondary Ion Mass Spectrometry A look at SIMS and Surface Analysis

2 Secondary Ion Mass Spectrometry What are Secondary Ions? Ions created from the interaction between a surface and an ion beam (the primary ions) Require high vacuum (≤10 -6 torr) in order to minimize ion-ion interactions Analyzed using a mass spectrometer Studies are used to gather information about the surface being analyzed and can fall in to two categories o Dynamic SIMS – used for bulk analysis using a DC ion beam and a QMS o Static SIMS – used for atomic monolayer analysis using a pulsed laser and a TOF

3 Target of SIMS Studies Typically flat surfaces or rods – CuBe – Al Rapidly growing interest in studying 3D – Organometallics and films from metal or semiconductor surfaces These trends demand that the Mass Spectrometer have – Better Resolution – Higher Sensitivity – Mass Range Options

4 MAX-CS Probes are the Proven Solution Powerful research grade instruments. o Best performance of flange mounted systems o Heart of Extrel’s VeraSpec Mass Spectrometer Systems o Widest array of options of any of our systems Mass Ranges – 50, 120, 500, 1000, 4000, 16000 maximum masses – Based off of quad size + RF frequency Two Quadrupole Sizes MS/MS option Multiple ionization sources Conical aperture on the Ionizer can be located close to the substrate to ionize the desorbed neutral compounds o Energy Filter Ionizer to differentiate between secondary ions and ionized neutrals in the chamber o Has fine control of the ionizer to perform “soft” ionization to retain the molecular ion without fragmentation SIMS Analysis Features of MAX Probe Systems

5 MAX-LT Probes Provide a Quality solution at an Affordable Cost Research grade performance at an affordable price. – 500 and 1000 amu mass ranges – Positive and negative ion detection Typical applications – Thermal Programmed Desorption (TPD) – Plasma and Chemical Vapor Deposition (CVD) Analysis – UHV Residual Gas Analysis.

6 SIMS Analysis: Energy Filter Ionizer High Energy ions (1 keV – 100 keV) – Not easily analyzed by QMS – Should be blocked from entering the analyzer Center stop of the energy filter – Keeps neutrals from entering the analyzer Blocks line-of-sight. Excellent Energy Filtering – Cylindrical lens of energy filter – Bandpass lenses above and below the cylinder – Center stop Cone aperture – Allows close placement to the target surface Greater sensitivity to the sputtered plume On-axis energy filter – Fine energy scan – < 0.6 eV FWHM (full width at half maximum) resolution

7 SimION Modeling of the Energy Filter Ionizer

8 CuBe Experiment The SIMS spectra for the CuBe alloy were collected using: MAX-120 with a tandem ionizer/energy analyzer o 19 mm Quadrupole & 2.1 MHz QC Base pressure: 1.6x10 -9 Torr Primary ions: 2 keV Ar + ions Incident angle (angle between the sample surface normal and the axis of the ion gun): ~ 80° Collection angle (the angle between the sample surface normal and the axis of the SIMS probe): ~ 10° All of the SIMS spectra were acquired after the sample had been sputtered with a much higher current of the Ar + ions. o SIMS spectra are characteristic of the unoxidized sample surface Ions of different kinetic energy were selected by the energy analyzer Ions coming out of the energy analyzer were then mass analyzed by the quadrupole mass filter o The pass energy of the energy analyzer is set by the voltage applied to the main cylindrical lens of the energy analyzer and the kinetic energy of the selected secondary ions is close to the pass energy

9 SIMS Spectra: 4.8 eV Pass Energy Copper Beryllium surface analysis

10 SIMS Spectra: 13.5 eV Pass Energy Copper Beryllium surface analysis

11 SIMS Spectra: 20.2 eV Pass Energy Copper Beryllium surface analysis

12 SIMS Spectra: 30.0 eV Pass Energy Copper Beryllium surface analysis

13 SIMS Data Summary The Be+ and Cu+ ion intensities measured at different pass energies allowing for precise measurement of each compound Pass Energy (eV)Beryllium Intensity (m/z 9; kCPS) Copper Intensity (m/z 63; kCPS) 4.8360<2 13.512054 20.210067 30.09236

14 Solutions to SIMS Analysis Characteristics of the secondary ions: o Absolute ion intensities depend on the pass energy o The Be-to-Cu ion intensity ratio changes with the pass energy The Be + and Cu + ions from the bombarded CuBe alloy surface have very different ion energy distributions Cu + ion intensity peaks around 20 eV Be + ions achieves its maximum intensity at a much lower kinetic energy

15 For More Information: Please visit us at Booth XXX Or on our website at Extrel.com